1.Coexisting Macular Hole and Uveal Melanoma: A Case Series and Literature Review
Yeji KIM ; So Hyun YU ; Yong Joon KIM ; Eun Young CHOI ; Sung Chul LEE ; Christopher Seungkyu LEE
Korean Journal of Ophthalmology 2025;39(2):170-180
Purpose:
To report five cases of macular hole (MH) coexisting with uveal melanoma (UM) and review the literature.
Methods:
Seventeen patients (5 new and 12 from previous reports) with coexisting MH and UM were reviewed. The patients were divided into two groups based on whether the MH was diagnosed before or after tumor treatment. The clinical features, pathogenesis, management options, and clinical outcomes were reviewed.
Results:
Of 505 patients with UM in our institution, 5 (1.0%) had a concurrent MH in the ipsilateral eye. The 17 patients reviewed had a mean age of 63.9 years at the time of MH diagnosis. Of 16 patients with available data on sex, 11 (64.7%) were female. There were no major differences in the demographic or clinical data of the groups. Of the 15 known tumor locations, 6 (35.3%) were juxtapapillary or macular. In patients who developed MH after UM treatment, the durations from tumor treatment (radiotherapy or transpupillary thermotherapy) to MH diagnosis were 3 to 56 months (median, 8.5 months). MH surgery was performed in nine eyes, and hole closure was achieved in seven eyes with postoperative data. The mean visual acuity showed a tendency of improvement after surgery. No intraocular or extraocular tumor dissemination associated with surgery was observed.
Conclusions
MH is observed in approximately 1% of patients with UM, either before or after tumor treatment. Of patients with coexisting MH and UM, MH surgery appears to be safe and effective in those with stable tumors and visual potential.
2.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
3.18F‑FDG PET/CT in Inflammation and Infection: Procedural Guidelineby the Korean Society of Nuclear Medicine
Joon Ho CHOI ; Yong‑Jin PARK ; Hyunjong LEE ; Hye Ryeong KWON ; Jinkyoung OH ; Chae Hong LIM ; Eun Ji HAN ; Joon Young CHOI ;
Nuclear Medicine and Molecular Imaging 2025;59(1):27-40
This guideline outlines the use of 18F-fluoro-2-deoxyglucose positron emission tomography / computed tomography for the diagnosis and management of infectious and inflammatory diseases. It provides detailed recommendations for healthcare providers on patient preparation, imaging procedures, and the interpretation of results. Adapted from international standards and tailored to local clinical practices, the guideline emphasizes safety, quality control, and effective use of the technology in various conditions, including spinal infections, diabetic foot, osteomyelitis, vasculitis, and cardiac inflammation. The aim is to assist nuclear medicine professionals in delivering accurate diagnoses and improving patient outcomes while allowing flexibility to adapt to individual patient needs, technological advancements, and evolving medical knowledge. This document is a comprehensive resource for enhancing the quality and safety of 18F-fluoro-2-deoxyglucose positron emission tomography / computed tomography for the evaluation of infectious and inflammatory diseases.Preamble The Korean Society of Nuclear Medicine (KSNM) was established in 1961 to promote the clinical and technological advancement of nuclear medicine in South Korea, with members that include nuclear medicine physicians and associated scientists. The KSNM regularly formulates and revises procedural guidelines for nuclear medicine examinations to enhance the field and improve the quality of patient care. These guidelines are designed to support healthcare professionals in providing appropriate medical care to patients. However, they are not immutable rules or mandatory requirements for conducting examinations.Therefore, KSNM states that these guidelines should not be used in legal actions challenging a healthcare professional’s medical decisions. The ultimate judgment regarding specific procedures or appropriate measures should be made by nuclear medicine physicians, considering the unique circumstances of each case. Deviation from these guidelines does not imply substandard medical practice. Rather, reasonable judgments differing from the guidelines can be made based on the patient’s condition, available resources, and advancements in knowledge or technology. Due to the diversity and complexity of patients, it is often challenging to predict the most appropriate diagnostic and accurate therapeutic responses. Thus, adherence to these guidelines does not always guarantee an exact diagnosis or successful outcomes.The purpose of this guideline is to assist healthcare providers in making reasonable decisions and conducting effective and safe examinations based on current medical knowledge, available resources, and patient needs when performing 18F-fluoro-2-deoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) examinations for infectious/ inflammatory diseases.
4.The Korean Organ Transplant Registry (KOTRY): Third Official Adult Heart Transplant Report
Hyo-In CHOI ; Sang Eun LEE ; Junho HYUN ; Darae KIM ; Dong-Ju CHOI ; Eun-Seok JEON ; Hae-Young LEE ; Hyun-Jai CHO ; Hyungseop KIM ; In-Cheol KIM ; Jaewon OH ; Minjae YOON ; Jin Joo PARK ; Jin-Oh CHOI ; Min Ho JU ; Seok-Min KANG ; Soo Yong LEE ; Sung-Ho JUNG ; Jae-Joong KIM
Korean Circulation Journal 2025;55(2):79-96
Background and Objectives:
The Korean Organ Transplant Registry (KOTRY) provided data for this third official report on adult heart transplantation (HT), including information from 709 recipients.
Methods:
Data from HTs performed at seven major centers in Korea between March 2014 and December 2020 were analyzed, focusing on immunosuppression, acute rejection, cardiac allograft vasculopathy (CAV), post-transplant survival, and mechanical circulatory support (MCS) usage.
Results:
The median ages of the recipients and donors were 56.0 and 43.0 years, respectively.Cardiomyopathy and ischemic heart disease were the most common preceding conditions for HT. A significant portion of patients underwent HT at waiting list status 1 and 0. In the multivariate analysis, a predicted heart mass mismatch was associated with a higher risk of 1-year mortality. Patients over 70 years old had a significantly increased risk of 6-year mortality. The risk of CAV was higher for male donors and donors older than 45 years. Acute rejection was more likely in patients with panel reactive antibody levels above 80%, while statin use was associated with a reduced risk. The employment of left ventricular assist device as a bridge to transplantation increased from 2.17% to 22.4%. Pre-transplant extra-corporeal membrane oxygenation was associated with worse post-transplant survival.
Conclusions
In this third KOTRY report, we analyzed changes in the characteristics of adult HT recipients and donors and their impact on post-transplant outcomes. The most notable discovery was the increased use of MCS before HT and their impact on post-transplant outcomes.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Cost-effectiveness of Fractional Flow Reserve Versus Intravascular Ultrasound to Guide Percutaneous Coronary Intervention: Results From the FLAVOUR Study
Doyeon HWANG ; Hea-Lim KIM ; Jane KO ; HyunJin CHOI ; Hanna JEONG ; Sun-ae JANG ; Xinyang HU ; Jeehoon KANG ; Jinlong ZHANG ; Jun JIANG ; Joo-Yong HAHN ; Chang-Wook NAM ; Joon-Hyung DOH ; Bong-Ki LEE ; Weon KIM ; Jinyu HUANG ; Fan JIANG ; Hao ZHOU ; Peng CHEN ; Lijiang TANG ; Wenbing JIANG ; Xiaomin CHEN ; Wenming HE ; Sung Gyun AHN ; Ung KIM ; You-Jeong KI ; Eun-Seok SHIN ; Hyo-Soo KIM ; Seung-Jea TAHK ; JianAn WANG ; Tae-Jin LEE ; Bon-Kwon KOO ;
Korean Circulation Journal 2025;55(1):34-46
Background and Objectives:
The Fractional Flow Reserve and Intravascular UltrasoundGuided Intervention Strategy for Clinical Outcomes in Patients with Intermediate Stenosis (FLAVOUR) trial demonstrated non-inferiority of fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) compared with intravascular ultrasound (IVUS)-guided PCI. We sought to investigate the cost-effectiveness of FFR-guided PCI compared to IVUS-guided PCI in Korea.
Methods:
A 2-part cost-effectiveness model, composed of a short-term decision tree model and a long-term Markov model, was developed for patients who underwent PCI to treat intermediate stenosis (40% to 70% stenosis by visual estimation on coronary angiography).The lifetime healthcare costs and quality-adjusted life-years (QALYs) were estimated from the healthcare system perspective. Transition probabilities were mainly referred from the FLAVOUR trial, and healthcare costs were mainly obtained through analysis of Korean National Health Insurance claims data. Health utilities were mainly obtained from the Seattle Angina Questionnaire responses of FLAVOUR trial participants mapped to EQ-5D.
Results:
From the Korean healthcare system perspective, the base-case analysis showed that FFR-guided PCI was 2,451 U.S. dollar lower in lifetime healthcare costs and 0.178 higher in QALYs compared to IVUS-guided PCI. FFR-guided PCI remained more likely to be cost-effective over a wide range of willingness-to-pay thresholds in the probabilistic sensitivity analysis.
Conclusions
Based on the results from the FLAVOUR trial, FFR-guided PCI is projected to decrease lifetime healthcare costs and increase QALYs compared with IVUS-guided PCI in intermediate coronary lesion, and it is a dominant strategy in Korea.
7.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
8.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
9.Coexisting Macular Hole and Uveal Melanoma: A Case Series and Literature Review
Yeji KIM ; So Hyun YU ; Yong Joon KIM ; Eun Young CHOI ; Sung Chul LEE ; Christopher Seungkyu LEE
Korean Journal of Ophthalmology 2025;39(2):170-180
Purpose:
To report five cases of macular hole (MH) coexisting with uveal melanoma (UM) and review the literature.
Methods:
Seventeen patients (5 new and 12 from previous reports) with coexisting MH and UM were reviewed. The patients were divided into two groups based on whether the MH was diagnosed before or after tumor treatment. The clinical features, pathogenesis, management options, and clinical outcomes were reviewed.
Results:
Of 505 patients with UM in our institution, 5 (1.0%) had a concurrent MH in the ipsilateral eye. The 17 patients reviewed had a mean age of 63.9 years at the time of MH diagnosis. Of 16 patients with available data on sex, 11 (64.7%) were female. There were no major differences in the demographic or clinical data of the groups. Of the 15 known tumor locations, 6 (35.3%) were juxtapapillary or macular. In patients who developed MH after UM treatment, the durations from tumor treatment (radiotherapy or transpupillary thermotherapy) to MH diagnosis were 3 to 56 months (median, 8.5 months). MH surgery was performed in nine eyes, and hole closure was achieved in seven eyes with postoperative data. The mean visual acuity showed a tendency of improvement after surgery. No intraocular or extraocular tumor dissemination associated with surgery was observed.
Conclusions
MH is observed in approximately 1% of patients with UM, either before or after tumor treatment. Of patients with coexisting MH and UM, MH surgery appears to be safe and effective in those with stable tumors and visual potential.
10.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.

Result Analysis
Print