1.Reproducibility of Plasma Biomarker Measurements Across Laboratories:Insights Into ptau217, GFAP, and NfL
Heekyoung KANG ; Sook-Young WOO ; Daeun SHIN ; Sohyun YIM ; Eun Hye LEE ; Hyunchul RYU ; Bora CHU ; Henrik ZETTERBERG ; Kaj BLENNOW ; Jihwan YUN ; Duk L NA ; Hee Jin KIM ; Hyemin JANG ; Jun Pyo KIM ;
Dementia and Neurocognitive Disorders 2025;24(2):91-101
Background:
and Purpose: Plasma biomarkers, including phosphorylated tau (ptau217), glial fibrillary acidic protein (GFAP), and neurofilament light chain (NfL), are promising tools for detecting Alzheimer’s disease (AD) pathology. However, cross-laboratory reproducibility remains a challenge, even when using identical analytical platforms such as single-molecule array (Simoa). This study aimed to compare plasma biomarker measurements (ptau217, GFAP, and NfL) between 2 laboratories, the University of Gothenburg (UGOT) and DNAlink, and evaluate their associations with amyloid positron emission tomography (PET) imaging.
Methods:
Plasma biomarkers were measured using Simoa platforms at both laboratories:the UGOT and DNAlink Incorporation. Diagnostic performance for predicting amyloid PET positivity, cross-laboratory agreement, and the impact of normalization techniques were assessed. Bland-Altman plots and correlation analyses were employed to evaluate agreement and variability.
Results:
Plasma ptau217 concentrations exhibited strong correlations with amyloid PET global centiloid values, with comparable diagnostic performance between laboratories (area under the curve=0.94 for UGOT and 0.95 for DNAlink). Cross-laboratory agreement for ptau217 was excellent (r=0.96), improving further after natural log transformation. GFAP and NfL also demonstrated moderate to strong correlations (r=0.86 for GFAP and r=0.99 for NfL), with normalization reducing variability.
Conclusions
Plasma biomarker measurements were consistent across laboratories using identical Simoa platforms, with strong diagnostic performance and improved agreement after normalization. These findings support the scalability of plasma biomarkers for multicenter studies and underscore their potential for standardized applications in AD research and clinical practice.
2.Synthetic data production for biomedical research
Yun Gyeong LEE ; Mi-Sook KWAK ; Jeong Eun KIM ; Min Sun KIM ; Dong Un NO ; Hee Youl CHAI
Osong Public Health and Research Perspectives 2025;16(2):94-99
Synthetic data, generated using advanced artificial intelligence (AI) techniques, replicates the statistical properties of real-world datasets while excluding identifiable information.Although synthetic data does not consist of actual data points, it is derived from original datasets, thereby enabling analyses that yield results comparable to those obtained with real data. Synthetic datasets are evaluated based on their utility—a measure of how effectively they mirror real data for analytical purposes. This paper presents the generation of synthetic datasets through the Healthcare Big Data Showcase Project (2019–2023). The original dataset comprises comprehensive multi-omics data from 400 individuals, including cancer survivors, chronic disease patients, and healthy participants. Synthetic data facilitates efficient access and robust analyses, serving as a practical tool for research and education. It addresses privacy concerns, supports AI research, and provides a foundation for innovative applications across diverse fields, such as public health and precision medicine.
3.Novel non-invasive and quantitative assessment of the renal function of transplanted kidneys using Doppler ultrasonography with the vascular index of superb microvascular imaging
Sung Hwan BAE ; Eun Ji LEE ; Jiyoung HWANG ; Seong Sook HONG ; Yun-Woo CHANG ; Boda NAM
Ultrasonography 2025;44(2):160-169
Purpose:
This study assessed the reproducibility and clinical value of the vascular index (VI), derived from superb microvascular imaging (SMI) using Doppler ultrasonography, for evaluating renal function in transplanted kidneys.
Methods:
This retrospective study included 63 renal transplant patients who underwent grayscale and Doppler ultrasonography with SMI from January 2022 to February 2023. The VI of the transplanted kidneys was measured using three methods (VIbox, VIF1, VIF2). The VI was compared across chronic kidney disease (CKD) groups categorized by estimated glomerular filtration rate (eGFR) and Kidney Disease: Improving Global Outcomes (KDIGO) CKD risk groups based on eGFR and albuminuria. The correlation between VI and renal function was evaluated. Univariate and multivariate linear regression analyses were used to identify predictors of eGFR.
Results:
Significant differences in VI were observed among CKD groups based on eGFR (VIbox, P=0.001; VIF1, P<0.001; VIF2, P<0.001) and KDIGO CKD groups based on eGFR and albuminuria (VIbox, P=0.039; VIF1, P=0.001; VIF2, P<0.001). VIF1 and VIF2 demonstrated moderate/high correlations with eGFR (r=0.627, P<0.001 and r=0.657, P<0.001, respectively) and serum creatinine (r=-0.626, P<0.001 and r=-0.649, P<0.001, respectively). VIbox moderately correlated with eGFR (r=0.445, P<0.001). Multivariate regression identified the urine albumincreatinine ratio (ACR) (adjusted odds ratio [aOR], 1.122; 95% confidence interval [CI], -0.007 to, 0.000; P=0.030) and VIF2 (aOR, 1.114; 95% CI, 0.466 to 1.235; P<0.001) were independently associated with eGFR.
Conclusion
The VI measured by drawing a region of interest along the border of the transplanted kidney in SMI (VIF2) is highly reproducible and correlates well with eGFR. Both VIF2 and ACR independently predict eGFR.
4.Effects of Pressure Hemostasis Band Application on Bleeding, Pain, and Discomfort after Bone Marrow Examination
Jin Hee JUNG ; Bo-Eun KIM ; Ji Sook JU ; Mi RYU ; So Young CHOE ; Jong Hee CHOI ; Soo-Mee BANG ; Jeong-Ok LEE ; Ji Yun LEE ; Sang-A KIM
Asian Oncology Nursing 2025;25(1):17-27
Purpose:
The purpose of this study was to develop an approach to alleviate the discomfort caused by sandbag compression after a bone marrow examination. This research examined the effects of applying a pressure hemostasis band on bleeding, pain, and discomfort at the bone marrow examination site.
Methods:
This study was conducted with a nonequivalent control group non-synchronized design. For 74 patients under evaluation who underwent bone marrow examination, sandbag compression was applied to the examination site in the control group (n=37), and a pressure hemostasis band was applied to the intervention group (n=37). In both groups, absolute bed rest was performed for two hours, and bleeding, pain, and discomfort at the examination site were measured.
Results:
After two hours of the bone marrow examination, there was no difference in bleeding on the gauze between the two groups (F=0.59, p=.444). Bleeding occurred in three patients in the intervention group and six in the control group (χ 2 =1.14, p=.479), with no cases of hematoma detected in either group. One hour post-examination, the control group experienced significantly higher pain (F=5.45, p=.022) and discomfort (F=5.68, p=.020) than the intervention group. However, pain and discomfort levels were similar between groups after two hours.
Conclusion
Compared to the sandbag compression group, the band application group showed no difference in bleeding and experienced less pain and discomfort at the examination site. This confirms that the pressure hemostasis band is a suitable alternative to sandbag compression in post-examination care.
5.Synthetic data production for biomedical research
Yun Gyeong LEE ; Mi-Sook KWAK ; Jeong Eun KIM ; Min Sun KIM ; Dong Un NO ; Hee Youl CHAI
Osong Public Health and Research Perspectives 2025;16(2):94-99
Synthetic data, generated using advanced artificial intelligence (AI) techniques, replicates the statistical properties of real-world datasets while excluding identifiable information.Although synthetic data does not consist of actual data points, it is derived from original datasets, thereby enabling analyses that yield results comparable to those obtained with real data. Synthetic datasets are evaluated based on their utility—a measure of how effectively they mirror real data for analytical purposes. This paper presents the generation of synthetic datasets through the Healthcare Big Data Showcase Project (2019–2023). The original dataset comprises comprehensive multi-omics data from 400 individuals, including cancer survivors, chronic disease patients, and healthy participants. Synthetic data facilitates efficient access and robust analyses, serving as a practical tool for research and education. It addresses privacy concerns, supports AI research, and provides a foundation for innovative applications across diverse fields, such as public health and precision medicine.
6.Novel non-invasive and quantitative assessment of the renal function of transplanted kidneys using Doppler ultrasonography with the vascular index of superb microvascular imaging
Sung Hwan BAE ; Eun Ji LEE ; Jiyoung HWANG ; Seong Sook HONG ; Yun-Woo CHANG ; Boda NAM
Ultrasonography 2025;44(2):160-169
Purpose:
This study assessed the reproducibility and clinical value of the vascular index (VI), derived from superb microvascular imaging (SMI) using Doppler ultrasonography, for evaluating renal function in transplanted kidneys.
Methods:
This retrospective study included 63 renal transplant patients who underwent grayscale and Doppler ultrasonography with SMI from January 2022 to February 2023. The VI of the transplanted kidneys was measured using three methods (VIbox, VIF1, VIF2). The VI was compared across chronic kidney disease (CKD) groups categorized by estimated glomerular filtration rate (eGFR) and Kidney Disease: Improving Global Outcomes (KDIGO) CKD risk groups based on eGFR and albuminuria. The correlation between VI and renal function was evaluated. Univariate and multivariate linear regression analyses were used to identify predictors of eGFR.
Results:
Significant differences in VI were observed among CKD groups based on eGFR (VIbox, P=0.001; VIF1, P<0.001; VIF2, P<0.001) and KDIGO CKD groups based on eGFR and albuminuria (VIbox, P=0.039; VIF1, P=0.001; VIF2, P<0.001). VIF1 and VIF2 demonstrated moderate/high correlations with eGFR (r=0.627, P<0.001 and r=0.657, P<0.001, respectively) and serum creatinine (r=-0.626, P<0.001 and r=-0.649, P<0.001, respectively). VIbox moderately correlated with eGFR (r=0.445, P<0.001). Multivariate regression identified the urine albumincreatinine ratio (ACR) (adjusted odds ratio [aOR], 1.122; 95% confidence interval [CI], -0.007 to, 0.000; P=0.030) and VIF2 (aOR, 1.114; 95% CI, 0.466 to 1.235; P<0.001) were independently associated with eGFR.
Conclusion
The VI measured by drawing a region of interest along the border of the transplanted kidney in SMI (VIF2) is highly reproducible and correlates well with eGFR. Both VIF2 and ACR independently predict eGFR.
7.Synthetic data production for biomedical research
Yun Gyeong LEE ; Mi-Sook KWAK ; Jeong Eun KIM ; Min Sun KIM ; Dong Un NO ; Hee Youl CHAI
Osong Public Health and Research Perspectives 2025;16(2):94-99
Synthetic data, generated using advanced artificial intelligence (AI) techniques, replicates the statistical properties of real-world datasets while excluding identifiable information.Although synthetic data does not consist of actual data points, it is derived from original datasets, thereby enabling analyses that yield results comparable to those obtained with real data. Synthetic datasets are evaluated based on their utility—a measure of how effectively they mirror real data for analytical purposes. This paper presents the generation of synthetic datasets through the Healthcare Big Data Showcase Project (2019–2023). The original dataset comprises comprehensive multi-omics data from 400 individuals, including cancer survivors, chronic disease patients, and healthy participants. Synthetic data facilitates efficient access and robust analyses, serving as a practical tool for research and education. It addresses privacy concerns, supports AI research, and provides a foundation for innovative applications across diverse fields, such as public health and precision medicine.
8.Novel non-invasive and quantitative assessment of the renal function of transplanted kidneys using Doppler ultrasonography with the vascular index of superb microvascular imaging
Sung Hwan BAE ; Eun Ji LEE ; Jiyoung HWANG ; Seong Sook HONG ; Yun-Woo CHANG ; Boda NAM
Ultrasonography 2025;44(2):160-169
Purpose:
This study assessed the reproducibility and clinical value of the vascular index (VI), derived from superb microvascular imaging (SMI) using Doppler ultrasonography, for evaluating renal function in transplanted kidneys.
Methods:
This retrospective study included 63 renal transplant patients who underwent grayscale and Doppler ultrasonography with SMI from January 2022 to February 2023. The VI of the transplanted kidneys was measured using three methods (VIbox, VIF1, VIF2). The VI was compared across chronic kidney disease (CKD) groups categorized by estimated glomerular filtration rate (eGFR) and Kidney Disease: Improving Global Outcomes (KDIGO) CKD risk groups based on eGFR and albuminuria. The correlation between VI and renal function was evaluated. Univariate and multivariate linear regression analyses were used to identify predictors of eGFR.
Results:
Significant differences in VI were observed among CKD groups based on eGFR (VIbox, P=0.001; VIF1, P<0.001; VIF2, P<0.001) and KDIGO CKD groups based on eGFR and albuminuria (VIbox, P=0.039; VIF1, P=0.001; VIF2, P<0.001). VIF1 and VIF2 demonstrated moderate/high correlations with eGFR (r=0.627, P<0.001 and r=0.657, P<0.001, respectively) and serum creatinine (r=-0.626, P<0.001 and r=-0.649, P<0.001, respectively). VIbox moderately correlated with eGFR (r=0.445, P<0.001). Multivariate regression identified the urine albumincreatinine ratio (ACR) (adjusted odds ratio [aOR], 1.122; 95% confidence interval [CI], -0.007 to, 0.000; P=0.030) and VIF2 (aOR, 1.114; 95% CI, 0.466 to 1.235; P<0.001) were independently associated with eGFR.
Conclusion
The VI measured by drawing a region of interest along the border of the transplanted kidney in SMI (VIF2) is highly reproducible and correlates well with eGFR. Both VIF2 and ACR independently predict eGFR.
9.Anatomical Variations, Genitourinary Anomalies and Clinical Presentations in Obstructed Hemivagina and Ipsilateral Renal Anomaly Syndrome: Case Series
Hyun Jeong KIM ; Eun Ji LEE ; Yun-Woo CHANG ; Seong Sook HONG ; Jiyoung HWANG ; Boda NAM ; Sung Hwan BAE
Journal of the Korean Society of Radiology 2025;86(1):129-140
Obstructed hemivagina and ipsilateral renal anomaly (OHVIRA) syndrome is a rare Müllerian duct anomaly, commonly characterized by uterus didelphys, obstructed hemivagina, and ipsilateral renal agenesis. While these are the three most common genitourinary anomalies in OHVIRA syndrome, a spectrum of urogenital anomalies can be present. Knowledge of this spectrum is crucial for proper patient management and treatment planning. In this case series, we report on five patients with OHVIRA syndrome, each presenting with a urogenital anomaly other than the typical renal agenesis or uterus didelphys. We highlight the gynecological complications encountered, which clinicians and radiologists should be aware of.
10.Reproducibility of Plasma Biomarker Measurements Across Laboratories:Insights Into ptau217, GFAP, and NfL
Heekyoung KANG ; Sook-Young WOO ; Daeun SHIN ; Sohyun YIM ; Eun Hye LEE ; Hyunchul RYU ; Bora CHU ; Henrik ZETTERBERG ; Kaj BLENNOW ; Jihwan YUN ; Duk L NA ; Hee Jin KIM ; Hyemin JANG ; Jun Pyo KIM ;
Dementia and Neurocognitive Disorders 2025;24(2):91-101
Background:
and Purpose: Plasma biomarkers, including phosphorylated tau (ptau217), glial fibrillary acidic protein (GFAP), and neurofilament light chain (NfL), are promising tools for detecting Alzheimer’s disease (AD) pathology. However, cross-laboratory reproducibility remains a challenge, even when using identical analytical platforms such as single-molecule array (Simoa). This study aimed to compare plasma biomarker measurements (ptau217, GFAP, and NfL) between 2 laboratories, the University of Gothenburg (UGOT) and DNAlink, and evaluate their associations with amyloid positron emission tomography (PET) imaging.
Methods:
Plasma biomarkers were measured using Simoa platforms at both laboratories:the UGOT and DNAlink Incorporation. Diagnostic performance for predicting amyloid PET positivity, cross-laboratory agreement, and the impact of normalization techniques were assessed. Bland-Altman plots and correlation analyses were employed to evaluate agreement and variability.
Results:
Plasma ptau217 concentrations exhibited strong correlations with amyloid PET global centiloid values, with comparable diagnostic performance between laboratories (area under the curve=0.94 for UGOT and 0.95 for DNAlink). Cross-laboratory agreement for ptau217 was excellent (r=0.96), improving further after natural log transformation. GFAP and NfL also demonstrated moderate to strong correlations (r=0.86 for GFAP and r=0.99 for NfL), with normalization reducing variability.
Conclusions
Plasma biomarker measurements were consistent across laboratories using identical Simoa platforms, with strong diagnostic performance and improved agreement after normalization. These findings support the scalability of plasma biomarkers for multicenter studies and underscore their potential for standardized applications in AD research and clinical practice.

Result Analysis
Print
Save
E-mail