1.Screening Outcomes of Supplemental Automated Breast Ultrasound in Women With Nondense Breasts Undergoing Mammography
Mi-ri KWON ; Mi Yeon LEE ; Suhyeon MOON ; Eun Sook KO ; Eun Young KO ; Boo Kyung HAN ; Inyoung YOUN ; Yoon Jung CHOI ; Shin Ho KOOK ; Jai Min RYU ; Ji Soo CHOI
Korean Journal of Radiology 2026;27(1):14-26
Objective:
To evaluate the performance of supplemental automated breast ultrasound (ABUS) added to mammography-based breast cancer screening for women with nondense breasts.
Materials and Methods:
A retrospective search of radiology databases at two tertiary institutions identified asymptomatic women with nondense breasts who underwent breast cancer screening using both digital mammography (DM) and supplemental ABUS between January 2020 and December 2023. We excluded women without sufficient follow-up data or those without an established final diagnosis, including histopathologic results. The performance measures of DM alone and ABUS combined with DM (ABUS plus DM) were compared. The primary outcome was the cancer detection rate (CDR), and the secondary outcomes were sensitivity and specificity. Subgroup analyses were performed for women with scattered fibroglandular density and almost entirely fatty breasts.
Results:
A total of 2,904 pairs of screening examinations were performed in 1,683 women (59 ± 10 years), detecting 26 cancers. In comparison with DM alone, ABUS plus DM showed higher CDR (9.0 vs. 7.9 per 1,000 examinations, P < 0.001), higher sensitivity (100% [26/26] vs. 88.5% [23/26], P < 0.001), and lower specificity (95.0% [2,735/2,878] vs. 97.9% [2,817/2,878], P < 0.001). In women with scattered fibroglandular density, ABUS increased the CDR from 7.4 to 8.5 per 1,000 examinations and improved the sensitivity from 87.0% [20/23] to 100% [23/23] (P < 0.001). In women with almost entirely fatty breasts, ABUS plus DM showed the same CDR (16.4 per 1,000 examinations) and sensitivity (100% [3/3]) as DM alone. Three cancers (11.5% [3/26]), all of which were stage T1N0, were detected only by supplemental ABUS.
Conclusion
Supplemental ABUS improved cancer detection and sensitivity in women with nondense breasts, with the benefits primarily observed in those with scattered fibroglandular density.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Current Practices and Perspectives of Pediatric Palliative Care Workers in South Korea
Eun Sook KIM ; Mikyung PARK ; Saet Byeol KIM ; Sunhee CHOI ; Nari YOON ; Sujeong KIM
Journal of Hospice and Palliative Care 2025;28(2):56-70
Purpose:
This study explored current pediatric palliative care (PPC) in South Korea and suggests future directions based on the perspectives of full-time PPC workers.
Methods:
A mixed-methods secondary analysis was conducted using survey data from nurses and social workers involved in a government PPC project. The survey assessed services provided by hospitals, nurses, and social workers, and gathered perceptions of challenging tasks, evidence needs, the significance of PPC, and future expectations through open-ended questions. Data were analyzed using frequency and conventional content analyses.
Results:
Eighteen full-time workers from nine of the ten project hospitals participated. Eight hospitals provided pain and symptom management and all offered counseling and education for patients and parents. Only one provided respite care and legacy-making services. Bereavement care was offered in all hospitals primarily through individual counseling and there were also three self-help groups. Nurses have diverse roles including in practice, education, leadership, research, and consultation. Social workers address psychosocial and economic challenges, rehabilitation and social reintegration. The workers highlighted the challenges in end-of-life care and communication, stressing the need for protocols and further training.PPC was seen as meaningful by patients and families, as well as staff.
Conclusion
Despite significant progress in PPC in South Korea, quantitative capacity remains limited. Further qualitative improvements in policies, practices, human resource development, and healthcare training are essential. This study provides insights into current PPC practices and their limitations. The development of practical evidence to enhance employment stability warrants further investigation.
7.Research Trends in Artificial Intelligence Applications in Dental Hygiene and Dentistry in Korean Academic Journals: A Scoping Review
Eun-Ha JUNG ; Bo-Ra KIM ; Soon-Jeong JEONG ; Mi-Sook YOON ; Ji-Hyun MIN ; Miyuki KIBAYASHI
Journal of Dental Hygiene Science 2025;25(4):306-324
Background:
This scoping review examined research on artificial intelligence (AI) published in Korean academic journals in thefields of dental hygiene and dentistry. The Context–Concept–Maturity framework was applied to compare research trends and identify future directions.
Methods:
Following the Arksey and O’Malley framework, with extensions by Levac et al., the review adhered to Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews guidelines. Domestic academic journals published between January 1, 2020, and September 30, 2025, were searched in KISS, RISS, ScienceON, and DBpia. Studies were screened, extracted, and coded according to population, concept, and context criteria, yielding 70 eligible articles (26 in dental hygiene and 44 in dentistry).
Results:
In dental hygiene, most research focused on education (38.5%) and community/public oral health (38.5%), while clinicalapplications were limited (7.7%). Major conceptual domains included education/training tools (42.3%), workflow/automation (38.5%), prediction (15.4%), and classification (3.8%). Dentistry studies were predominantly clinically oriented and imagingbased, emphasizing classification, automation, and segmentation. Maturity analysis indicated that dentistry primarily occupied Stage 2 (application; ∼84.1%), whereas dental hygiene showed a dual distribution across Stage 1 (exploration; 46.2%) and Stage 2 (application; 46.2%), with limited Stage 3 (integration; 7.7%) studies.
Conclusion
AI research in Korea exhibits divergent developmental trajectories. Dental hygiene research emphasizes education,prevention, and public oral health, combining exploratory and applied approaches, while dentistry demonstrates greater clinical integration and application-level maturity. Advancing AI maturity in dental hygiene will require expansion of clinical data–driven studies, incorporation of AI and data literacy into curricula, standardized integration of unstructured and clinical data, multicenter long-term validation, and the development of ethical and performance governance frameworks.
8.Comparison of Population Attributable Fractions of Cancer Incidence and Mortality Linked to Excess Body Weight in Korea from 2015 to 2030
Youjin HONG ; Jihye AN ; Jeehi JUNG ; Hyeon Sook LEE ; Soseul SUNG ; Sungji MOON ; Inah KIM ; Jung Eun LEE ; Aesun SHIN ; Sun Ha JEE ; Sun-Seog KWEON ; Min-Ho SHIN ; Sangmin PARK ; Seung-Ho RYU ; Sun Young YANG ; Seung Ho CHOI ; Jeongseon KIM ; Sang-Wook YI ; Yoon-Jung CHOI ; Sangjun LEE ; Woojin LIM ; Kyungsik KIM ; Sohee PARK ; Jeong-Soo IM ; Hong Gwan SEO ; Kwang-Pil KO ; Sue K. PARK
Endocrinology and Metabolism 2024;39(6):921-931
Background:
The increasing rate of excess body weight (EBW) in the global population has led to growing health concerns, including cancer-related EBW. We aimed to estimate the population attributable fraction (PAF) of cancer incidence and deaths linked to EBW in Korean individuals from 2015 to 2030 and to compare its value with various body mass index cutoffs.
Methods:
Levin’s formula was used to calculate the PAF; the prevalence rates were computed using the Korean National Health and Nutrition Examination Survey data, while the relative risks of specific cancers related to EBW were estimated based on the results of Korean cohort studies. To account for the 15-year latency period when estimating the PAF in 2020, the prevalence rates from 2015 and attributable cases or deaths from 2020 were used.
Results:
The PAF attributed to EBW was similar for both cancer incidence and deaths using either the World Health Organization (WHO) Asian-Pacific region standard or a modified Asian standard, with the WHO standard yielding the lowest values. In the Korean population, the PAFs of EBW for cancer incidence were 2.96% in men and 3.61% in women, while those for cancer deaths were 0.67% in men and 3.06% in women in 2020. Additionally, PAFs showed a gradual increase in both sexes until 2030.
Conclusion
The EBW continues to have a significant impact on cancer incidence and deaths in Korea. Effective prevention strategies targeting the reduction of this modifiable risk factor can substantially decrease the cancer burden.
9.Comparison of Population Attributable Fractions of Cancer Incidence and Mortality Linked to Excess Body Weight in Korea from 2015 to 2030
Youjin HONG ; Jihye AN ; Jeehi JUNG ; Hyeon Sook LEE ; Soseul SUNG ; Sungji MOON ; Inah KIM ; Jung Eun LEE ; Aesun SHIN ; Sun Ha JEE ; Sun-Seog KWEON ; Min-Ho SHIN ; Sangmin PARK ; Seung-Ho RYU ; Sun Young YANG ; Seung Ho CHOI ; Jeongseon KIM ; Sang-Wook YI ; Yoon-Jung CHOI ; Sangjun LEE ; Woojin LIM ; Kyungsik KIM ; Sohee PARK ; Jeong-Soo IM ; Hong Gwan SEO ; Kwang-Pil KO ; Sue K. PARK
Endocrinology and Metabolism 2024;39(6):921-931
Background:
The increasing rate of excess body weight (EBW) in the global population has led to growing health concerns, including cancer-related EBW. We aimed to estimate the population attributable fraction (PAF) of cancer incidence and deaths linked to EBW in Korean individuals from 2015 to 2030 and to compare its value with various body mass index cutoffs.
Methods:
Levin’s formula was used to calculate the PAF; the prevalence rates were computed using the Korean National Health and Nutrition Examination Survey data, while the relative risks of specific cancers related to EBW were estimated based on the results of Korean cohort studies. To account for the 15-year latency period when estimating the PAF in 2020, the prevalence rates from 2015 and attributable cases or deaths from 2020 were used.
Results:
The PAF attributed to EBW was similar for both cancer incidence and deaths using either the World Health Organization (WHO) Asian-Pacific region standard or a modified Asian standard, with the WHO standard yielding the lowest values. In the Korean population, the PAFs of EBW for cancer incidence were 2.96% in men and 3.61% in women, while those for cancer deaths were 0.67% in men and 3.06% in women in 2020. Additionally, PAFs showed a gradual increase in both sexes until 2030.
Conclusion
The EBW continues to have a significant impact on cancer incidence and deaths in Korea. Effective prevention strategies targeting the reduction of this modifiable risk factor can substantially decrease the cancer burden.
10.Correction: 2023 Korean Society of Echocardiography position paper for diagnosis and management of valvular heart disease, part I: aortic valve disease
Sun Hwa LEE ; Se Jung YOON ; Byung Joo SUN ; Hyue Mee KIM ; Hyung Yoon KIM ; Sahmin LEE ; Chi Young SHIM ; Eun Kyoung KIM ; Dong Hyuk CHO ; Jun Bean PARK ; Jeong Sook SEO ; Jung Woo SON ; In Cheol KIM ; Sang Hyun LEE ; Ran HEO ; Hyun Jung LEE ; Jae Hyeong PARK ; Jong Min SONG ; Sang Chol LEE ; Hyungseop KIM ; Duk Hyun KANG ; Jong Won HA ; Kye Hun KIM ;
Journal of Cardiovascular Imaging 2024;32(1):34-

Result Analysis
Print
Save
E-mail