1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Occupational disease monitoring by the Korea Occupational Disease Surveillance Center: a narrative review
Dong-Wook LEE ; Inah KIM ; Jungho HWANG ; Sunhaeng CHOI ; Tae-Won JANG ; Insung CHUNG ; Hwan-Cheol KIM ; Jaebum PARK ; Jungwon KIM ; Kyoung Sook JEONG ; Youngki KIM ; Eun-Soo LEE ; Yangwoo KIM ; Inchul JEONG ; Hyunjeong OH ; Hyeoncheol OH ; Jea Chul HA ; Jeehee MIN ; Chul Gab LEE ; Heon KIM ; Jaechul SONG
The Ewha Medical Journal 2025;48(1):e9-
This review examines the challenges associated with occupational disease surveillance in Korea, particularly emphasizing the limitations of current data sources such as the Industrial Accident Compensation Insurance (IACI) statistics and special health examinations. The IACI system undercounts cases due to its emphasis on severe diseases and restrictions on approvals. Special health examinations, although they cover a broad workforce, are constrained by their annual scheduling, which leads to missed acute illnesses and subclinical conditions. The paper also explores the history of occupational disease surveillance in Korea, highlighting the fragmented and disease-specific approach of earlier systems. The authors introduce the newly established Korea Occupational Disease Surveillance Center (KODSC), a comprehensive nationwide system designed to gather, analyze, and interpret data on occupational diseases through a network of regional centers. By incorporating hospital-based surveillance and focusing on acute poisonings and other sentinel events, the KODSC aims to overcome the limitations of previous systems and promote collaboration with various agencies. Although it is still in the early stages of implementation, the KODSC demonstrates potential for improving data accuracy and contributing valuable insights for public health policy.
4.Occupational disease monitoring by the Korea Occupational Disease Surveillance Center: a narrative review
Dong-Wook LEE ; Inah KIM ; Jungho HWANG ; Sunhaeng CHOI ; Tae-Won JANG ; Insung CHUNG ; Hwan-Cheol KIM ; Jaebum PARK ; Jungwon KIM ; Kyoung Sook JEONG ; Youngki KIM ; Eun-Soo LEE ; Yangwoo KIM ; Inchul JEONG ; Hyunjeong OH ; Hyeoncheol OH ; Jea Chul HA ; Jeehee MIN ; Chul Gab LEE ; Heon KIM ; Jaechul SONG
The Ewha Medical Journal 2025;48(1):e9-
This review examines the challenges associated with occupational disease surveillance in Korea, particularly emphasizing the limitations of current data sources such as the Industrial Accident Compensation Insurance (IACI) statistics and special health examinations. The IACI system undercounts cases due to its emphasis on severe diseases and restrictions on approvals. Special health examinations, although they cover a broad workforce, are constrained by their annual scheduling, which leads to missed acute illnesses and subclinical conditions. The paper also explores the history of occupational disease surveillance in Korea, highlighting the fragmented and disease-specific approach of earlier systems. The authors introduce the newly established Korea Occupational Disease Surveillance Center (KODSC), a comprehensive nationwide system designed to gather, analyze, and interpret data on occupational diseases through a network of regional centers. By incorporating hospital-based surveillance and focusing on acute poisonings and other sentinel events, the KODSC aims to overcome the limitations of previous systems and promote collaboration with various agencies. Although it is still in the early stages of implementation, the KODSC demonstrates potential for improving data accuracy and contributing valuable insights for public health policy.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
7.Occupational disease monitoring by the Korea Occupational Disease Surveillance Center: a narrative review
Dong-Wook LEE ; Inah KIM ; Jungho HWANG ; Sunhaeng CHOI ; Tae-Won JANG ; Insung CHUNG ; Hwan-Cheol KIM ; Jaebum PARK ; Jungwon KIM ; Kyoung Sook JEONG ; Youngki KIM ; Eun-Soo LEE ; Yangwoo KIM ; Inchul JEONG ; Hyunjeong OH ; Hyeoncheol OH ; Jea Chul HA ; Jeehee MIN ; Chul Gab LEE ; Heon KIM ; Jaechul SONG
The Ewha Medical Journal 2025;48(1):e9-
This review examines the challenges associated with occupational disease surveillance in Korea, particularly emphasizing the limitations of current data sources such as the Industrial Accident Compensation Insurance (IACI) statistics and special health examinations. The IACI system undercounts cases due to its emphasis on severe diseases and restrictions on approvals. Special health examinations, although they cover a broad workforce, are constrained by their annual scheduling, which leads to missed acute illnesses and subclinical conditions. The paper also explores the history of occupational disease surveillance in Korea, highlighting the fragmented and disease-specific approach of earlier systems. The authors introduce the newly established Korea Occupational Disease Surveillance Center (KODSC), a comprehensive nationwide system designed to gather, analyze, and interpret data on occupational diseases through a network of regional centers. By incorporating hospital-based surveillance and focusing on acute poisonings and other sentinel events, the KODSC aims to overcome the limitations of previous systems and promote collaboration with various agencies. Although it is still in the early stages of implementation, the KODSC demonstrates potential for improving data accuracy and contributing valuable insights for public health policy.
8.Occupational disease monitoring by the Korea Occupational Disease Surveillance Center: a narrative review
Dong-Wook LEE ; Inah KIM ; Jungho HWANG ; Sunhaeng CHOI ; Tae-Won JANG ; Insung CHUNG ; Hwan-Cheol KIM ; Jaebum PARK ; Jungwon KIM ; Kyoung Sook JEONG ; Youngki KIM ; Eun-Soo LEE ; Yangwoo KIM ; Inchul JEONG ; Hyunjeong OH ; Hyeoncheol OH ; Jea Chul HA ; Jeehee MIN ; Chul Gab LEE ; Heon KIM ; Jaechul SONG
The Ewha Medical Journal 2025;48(1):e9-
This review examines the challenges associated with occupational disease surveillance in Korea, particularly emphasizing the limitations of current data sources such as the Industrial Accident Compensation Insurance (IACI) statistics and special health examinations. The IACI system undercounts cases due to its emphasis on severe diseases and restrictions on approvals. Special health examinations, although they cover a broad workforce, are constrained by their annual scheduling, which leads to missed acute illnesses and subclinical conditions. The paper also explores the history of occupational disease surveillance in Korea, highlighting the fragmented and disease-specific approach of earlier systems. The authors introduce the newly established Korea Occupational Disease Surveillance Center (KODSC), a comprehensive nationwide system designed to gather, analyze, and interpret data on occupational diseases through a network of regional centers. By incorporating hospital-based surveillance and focusing on acute poisonings and other sentinel events, the KODSC aims to overcome the limitations of previous systems and promote collaboration with various agencies. Although it is still in the early stages of implementation, the KODSC demonstrates potential for improving data accuracy and contributing valuable insights for public health policy.
9.Occupational disease monitoring by the Korea Occupational Disease Surveillance Center: a narrative review
Dong-Wook LEE ; Inah KIM ; Jungho HWANG ; Sunhaeng CHOI ; Tae-Won JANG ; Insung CHUNG ; Hwan-Cheol KIM ; Jaebum PARK ; Jungwon KIM ; Kyoung Sook JEONG ; Youngki KIM ; Eun-Soo LEE ; Yangwoo KIM ; Inchul JEONG ; Hyunjeong OH ; Hyeoncheol OH ; Jea Chul HA ; Jeehee MIN ; Chul Gab LEE ; Heon KIM ; Jaechul SONG
The Ewha Medical Journal 2025;48(1):e9-
This review examines the challenges associated with occupational disease surveillance in Korea, particularly emphasizing the limitations of current data sources such as the Industrial Accident Compensation Insurance (IACI) statistics and special health examinations. The IACI system undercounts cases due to its emphasis on severe diseases and restrictions on approvals. Special health examinations, although they cover a broad workforce, are constrained by their annual scheduling, which leads to missed acute illnesses and subclinical conditions. The paper also explores the history of occupational disease surveillance in Korea, highlighting the fragmented and disease-specific approach of earlier systems. The authors introduce the newly established Korea Occupational Disease Surveillance Center (KODSC), a comprehensive nationwide system designed to gather, analyze, and interpret data on occupational diseases through a network of regional centers. By incorporating hospital-based surveillance and focusing on acute poisonings and other sentinel events, the KODSC aims to overcome the limitations of previous systems and promote collaboration with various agencies. Although it is still in the early stages of implementation, the KODSC demonstrates potential for improving data accuracy and contributing valuable insights for public health policy.
10.Unenhanced Breast MRI With Diffusion-Weighted Imaging for Breast Cancer Detection: Effects of Training on Performance and Agreement of Subspecialty Radiologists
Yeon Soo KIM ; Su Hyun LEE ; Soo-Yeon KIM ; Eun Sil KIM ; Ah Reum PARK ; Jung Min CHANG ; Vivian Youngjean PARK ; Jung Hyun YOON ; Bong Joo KANG ; Bo La YUN ; Tae Hee KIM ; Eun Sook KO ; A Jung CHU ; Jin You KIM ; Inyoung YOUN ; Eun Young CHAE ; Woo Jung CHOI ; Hee Jeong KIM ; Soo Hee KANG ; Su Min HA ; Woo Kyung MOON
Korean Journal of Radiology 2024;25(1):11-23
Objective:
To investigate whether reader training improves the performance and agreement of radiologists in interpreting unenhanced breast magnetic resonance imaging (MRI) scans using diffusion-weighted imaging (DWI).
Materials and Methods:
A study of 96 breasts (35 cancers, 24 benign, and 37 negative) in 48 asymptomatic women was performed between June 2019 and October 2020. High-resolution DWI with b-values of 0, 800, and 1200 sec/mm 2 was performed using a 3.0-T system. Sixteen breast radiologists independently reviewed the DWI, apparent diffusion coefficient maps, and T1-weighted MRI scans and recorded the Breast Imaging Reporting and Data System (BI-RADS) category for each breast. After a 2-h training session and a 5-month washout period, they re-evaluated the BI-RADS categories. A BI-RADS category of 4 (lesions with at least two suspicious criteria) or 5 (more than two suspicious criteria) was considered positive.The per-breast diagnostic performance of each reader was compared between the first and second reviews. Inter-reader agreement was evaluated using a multi-rater κ analysis and intraclass correlation coefficient (ICC).
Results:
Before training, the mean sensitivity, specificity, and accuracy of the 16 readers were 70.7% (95% confidence interval [CI]: 59.4–79.9), 90.8% (95% CI: 85.6–94.2), and 83.5% (95% CI: 78.6–87.4), respectively. After training, significant improvements in specificity (95.2%; 95% CI: 90.8–97.5; P = 0.001) and accuracy (85.9%; 95% CI: 80.9–89.8; P = 0.01) were observed, but no difference in sensitivity (69.8%; 95% CI: 58.1–79.4; P = 0.58) was observed. Regarding inter-reader agreement, the κ values were 0.57 (95% CI: 0.52–0.63) before training and 0.68 (95% CI: 0.62–0.74) after training, with a difference of 0.11 (95% CI: 0.02–0.18; P = 0.01). The ICC was 0.73 (95% CI: 0.69–0.74) before training and 0.79 (95% CI: 0.76–0.80) after training (P = 0.002).
Conclusion
Brief reader training improved the performance and agreement of interpretations by breast radiologists using unenhanced MRI with DWI.

Result Analysis
Print
Save
E-mail