1.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
2.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
3.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
4.Corrigendum: Quality of Life in Colorectal Cancer Patients at Home 5-Fluorouracil Chemotherapy with Disposable Elastomeric Infusion Pumps
Chung Eun LEE ; Na Young KIM ; Me Hee PARK ; Yoon Jung LEE ; Jin Ra KIM ; Min Ju BAEK ; Hyo Jin KIM ; Eun Sung BYUN ; Yun Kyung KIL ; Heejung KIM
Journal of Korean Clinical Nursing Research 2023;29(1):146-147
5.Development of Entrustable Professional Activity, Core Competencies, and Guidelines in 2021 Radiology Competency Education Project
You Me KIM ; Moon Hyung CHOI ; Jei Hee LEE ; Yun-Jung LIM ; Young Jin KIM ; Jeong Seon PARK ; Su Jin HONG ; Jung Suk OH ; Ji Seon PARK ; A Leum LEE ; Seung Eun JUNG
Journal of the Korean Radiological Society 2022;83(2):284-292
To provide high-quality training to residents in a rapidly changing medical environment, it is very important to improve the annual training curriculum centered on competency and ensure that training hospitals maintain an environment suitable for training. The Korean Society of Radiology (KSR) has been steadily improving the training system and has suggested the improvement of the training system by strengthening the competency-based evaluation and faculty development. Currently, KSR was selected for the second annual training curriculum systematization construction project in July 2021, and developed entrustable professional activities, core competencies, and assessment guidelines required by the construction project. Therefore, the development process and assessment guidelines will be introduced to residents and the faculty.
6.Quality of Life in Colorectal Cancer Patients at Home 5-Fluorouracil Chemotherapy with Disposable Elastomeric Infusion Pumps
Chung Eun LEE ; Na Young KIM ; Me Hee PARK ; Yoon Jung LEE ; Jin Ra KIM ; Min Ju BAEK ; Hyo Jin KIM ; Eun Sung BYUN ; Yun Kyung KIL ; Heejung KIM
Journal of Korean Clinical Nursing Research 2022;28(1):76-87
Purpose:
The purpose of this study was to examine the psychological distress related to quality of life (QoL) of patients with colorectal cancer receiving 5-fluorouracil (5-FU) chemotherapy at home with disposable Elastomeric infusion pumps.
Methods:
In this study, 179 colorectal outpatients were recruited between September 2019 and January 2021. National Cancer Center Psychological Symptom Inventory scores, general self-efficacy, and the EORTC QLQ-C30 scores were measured. Data were analyzed using Independent t-test, One-way ANOVA with Bonferroni post hoc analysis, and hierarchical multiple linear regression with the SPSS/WIN 26.0 programs.
Results:
The overall prevalence of psychological distress was 52.0% in colorectal patients. In multiple regression, psychological distress (β=-.20, p=.005), appetite loss (β=-.20, p=.001), chemotherapy cycles (β= .19, p=.002), fatigue (β=-.16, p=.035), physical functioning (β=-.16, p=.024), and emotional functioning (β=-.15, p=.025) were significant factors of QoL, and the final model explained 45.0% of the total variance of QoL.
Conclusion
Supporting patients toward decreased psychological distress and increased physical and emotional functioning, especially in the first or second cycle of chemotherapy, could be used to improve their QoL. To consider the thresholds for clinical importance, it is necessary to increase the interpretation of psychological distress in clinical practice and further research.
7.Interobserver agreement in breast ultrasound categorization in the Mammography and Ultrasonography Study for Breast Cancer Screening Effectiveness (MUST-BE) trial: results of a preliminary study
Eun Jung CHOI ; Eun Hye LEE ; You Me KIM ; Yun Woo CHANG ; Jin Hwa LEE ; Young Mi PARK ; Keum Won KIM ; Young Joong KIM ; Jae Kwan JUN ; Seri HONG
Ultrasonography 2019;38(2):172-180
PURPOSE: The purpose of this study was to record and evaluate interobserver agreement as quality control for the modified categorization of screening breast ultrasound developed by the Alliance for Breast Cancer Screening in Korea (ABCS-K) for the Mammography and Ultrasonography Study for Breast Cancer Screening Effectiveness (MUST-BE) trial. METHODS: Eight breast radiologists with 4-16 years of experience participated in 2 rounds of quality control testing for the MUST-BE trial. Two investigators randomly selected 125 and 100 cases of breast lesions with different ratios of malignant and benign lesions. Two versions of the modified categorization were tested. The initially modified classification was developed after the first quality control workshop, and the re-modified classification was developed after the second workshop. The re-modified categorization established by ABCS-K added size criteria and the anterior-posterior ratio compared with the initially modified classification. After a brief lecture on the modified categorization system prior to each quality control test, the eight radiologists independently categorized the lesions using the modified categorization. Interobserver agreement was measured using kappa statistics. RESULTS: The overall kappa values for the modified categorizations indicated moderate to substantial degrees of agreement (initially modified categorization and re-modified categorization: κ=0.52 and κ=0.63, respectively). The kappa values for the subcategories of category 4 were 0.37 (95% confidence interval [CI], 0.24 to 0.52) and 0.39 (95% CI, 0.31 to 0.49), respectively. The overall kappa values for both the initially modified categorization and the re-modified categorization indicated a substantial degree of agreement when dichotomizing the interpretation as benign or suspicious. CONCLUSION: The preliminary results demonstrated acceptable interobserver agreement for the modified categorization.
Breast Neoplasms
;
Breast
;
Classification
;
Education
;
Humans
;
Korea
;
Mammography
;
Mass Screening
;
Observer Variation
;
Quality Control
;
Research Personnel
;
Ultrasonography
8.Effect of Different Types of Mammography Equipment on Screening Outcomes: A Report by the Alliance for Breast Cancer Screening in Korea
Bo Hwa CHOI ; Eun Hye LEE ; Jae Kwan JUN ; Keum Won KIM ; Young Mi PARK ; Hye Won KIM ; You Me KIM ; Dong Rock SHIN ; Hyo Soon LIM ; Jeong Seon PARK ; Hye Jung KIM ;
Korean Journal of Radiology 2019;20(12):1638-1645
OBJECTIVE: To investigate the effects of different types of mammography equipment on screening outcomes by comparing the performance of film-screen mammography (FSM), computed radiography mammography (CRM), and digital mammography (DM).MATERIALS AND METHODS: We retrospectively enrolled 128756 sets of mammograms from 10 hospitals participating in the Alliance for Breast Cancer Screening in Korea between 2005 and 2010. We compared the diagnostic accuracy of the types of mammography equipment by analyzing the area under the receiver operating characteristic curve (AUC) with a 95% confidence interval (CI); performance indicators, including recall rate, cancer detection rate (CDR), positive predictive value₁ (PPV₁), sensitivity, specificity, and interval cancer rate (ICR); and the types of breast cancer pathology.RESULTS: The AUCs were 0.898 (95% CI, 0.878–0.919) in DM, 0.860 (0.815–0.905) in FSM, and 0.866 (0.828–0.903) in CRM (p = 0.150). DM showed better performance than FSM and CRM in terms of the recall rate (14.8 vs. 24.8 and 19.8%), CDR (3.4 vs. 2.2 and 2.1 per 1000 examinations), PPV₁ (2.3 vs. 0.9 and 1.1%), and specificity (85.5 vs. 75.3 and 80.3%) (p < 0.001) but not in terms of sensitivity (86.3 vs. 87.4 and 86.3%) and ICR (0.6 vs. 0.4 and 0.4). The proportions of carcinoma in situ (CIS) were 27.5%, 13.6%, and 11.8% for DM, CRM, and FSM, respectively (p = 0.003).CONCLUSION: In comparison to FSM and CRM, DM showed better performance in terms of the recall rate, CDR, PPV₁, and specificity, although the AUCs were similar, and more CISs were detected using DM. The application of DM may help to improve the quality of mammography screenings. However, the overdiagnosis issue of CIS using DM should be evaluated.
Area Under Curve
;
Breast Neoplasms
;
Breast
;
Carcinoma in Situ
;
Korea
;
Mammography
;
Mass Screening
;
Medical Overuse
;
Pathology
;
Radiography
;
Retrospective Studies
;
ROC Curve
;
Sensitivity and Specificity
9.Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography.
Sang Youn KIM ; Jeong Yeon CHO ; Joongyub LEE ; Sung Il HWANG ; Min Hoan MOON ; Eun Ju LEE ; Seong Sook HONG ; Chan Kyo KIM ; Kyeong Ah KIM ; Sung Bin PARK ; Deuk Jae SUNG ; Yongsoo KIM ; You Me KIM ; Sung Il JUNG ; Sung Eun RHA ; Dong Won KIM ; Hyun LEE ; Youngsup SHIM ; Inpyeong HWANG ; Sungmin WOO ; Hyuck Jae CHOI
Korean Journal of Radiology 2018;19(6):1119-1129
OBJECTIVE: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. MATERIALS AND METHODS: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. RESULTS: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose (5.73 ± 4.04 vs. 8.43 ± 4.38 mSv) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ≥ 3), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. CONCLUSION: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.
Commerce
;
Contrast Media*
;
Humans
;
Iodine
;
Noise
;
Prospective Studies
;
Radiation Exposure
;
Signal-To-Noise Ratio
;
Urinary Tract
;
Urography*
10.Performance of Screening Mammography: A Report of the Alliance for Breast Cancer Screening in Korea.
Eun Hye LEE ; Keum Won KIM ; Young Joong KIM ; Dong Rock SHIN ; Young Mi PARK ; Hyo Soon LIM ; Jeong Seon PARK ; Hye Won KIM ; You Me KIM ; Hye Jung KIM ; Jae Kwan JUN
Korean Journal of Radiology 2016;17(4):489-496
OBJECTIVE: To analyze the diagnostic accuracy and trend in screening mammography in Korea. MATERIALS AND METHODS: We retrospectively linked the information from hospitals participating in the Alliance of Breast Cancer Screening in Korea (ABCS-K) and the database of the National Cancer Screening Program. We calculated performance indicators, including the recall rate, cancer detection rate (CDR), positive predictive value (PPV), sensitivity, specificity, false-positive rate (FPR), and interval cancer rate (ICR). Changes in the performance indicators were calculated as the annual percent change with 95% confidence interval (CI). RESULTS: We enrolled 128756 cases from 10 hospitals from 2005 to 2010. The recall rate was 19.1% with a downward trend over time (-12.1% per year; 95% CI, -15.9 to -8.2). The CDR was 2.69 per 1000 examinations, without a significant trend. The PPV was 1.4% with an upward trend (20.8% per year; 95% CI, 15.2 to 26.7). The sensitivity was 86.5% without a significant trend, whereas the specificity was 81.1% with an upward trend (3.3% per year; 95% CI, 2.1 to 4.5). The FPR was 18.9% with a downward trend (-12.4% per year; 95% CI, -16.2 to -8.4). The ICR was 0.5 per 1000 negative examinations without a significant trend. There were institutional variations in the diagnostic accuracy and trend except for the CDR, sensitivity, and ICR. CONCLUSION: The sensitivity and CDR of screening mammography in the ABCS-K from 2005 to 2010 were compatible with those for Western women. The recall rate, PPV and specificity, however, were suboptimal, although they showed significant improvements over this period. A further analysis is required to explain institutional variations.
Breast Neoplasms*
;
Breast*
;
Early Detection of Cancer
;
Female
;
Humans
;
Korea*
;
Mammography*
;
Mass Screening*
;
Retrospective Studies
;
Sensitivity and Specificity

Result Analysis
Print
Save
E-mail