1.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
2.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
6.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
7.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
8.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
9.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
10.Serum Cocaine- and Amphetamine-Regulated Transcript Levels and Cooperativeness in Adolescents With Internet Gaming Disorder
Hyunho LEE ; Dong Huey CHEON ; Heejin LEE ; Arom PYEON ; Ji-Won CHUN ; Ji Hyun BACK ; Yae Eun PARK ; Hong CHOI ; Dai-Jin KIM ; Ji Eun LEE ; Jung-Seok CHOI
Psychiatry Investigation 2025;22(12):1416-1421
Objective:
Internet gaming disorder (IGD) is a growing problem, particularly among adolescents. Although cocaine- and amphetamine- regulated transcript (CART) has been explored as a potential biomarker for addictive disorders, its relationship with IGD remains poorly understood. This study investigated the differences in serum CART levels between adolescents with IGD and healthy controls (HCs) in order to find potential biomarkers as a therapeutic target in IGD. Additionally, we investigated correlations of serum CART levels with personality traits within the IGD group.
Methods:
A total of 114 adolescents participated in this study (43 in the IGD group and 71 in the HC group). Blood samples (10 mL) were collected and serum CART concentrations were determined using an enzyme-linked immunosorbent assay. Participants also completed the Junior Temperament and Character Inventory.
Results:
Serum CART levels in the IGD group were significantly lower than those in the HC group (p<0.05). IGD participants had higher novelty-seeking and harm-avoidance traits, accompanied by reduced persistence, self-directedness, and cooperativeness. Notably, a significant correlation emerged between serum CART levels and cooperativeness within the IGD group. Lower cooperativeness trait scores could indicate reduced social interaction.
Conclusion
The present findings suggest serum CART levels might serve as a neurobiological marker for cooperativeness function in adolescents with IGD.

Result Analysis
Print
Save
E-mail