1.Nipple swab culture profile as a potential predictor of postoperative complications in autologous breast reconstruction: a retrospective study
Sun-Hyeok KIM ; Yi-Jun MOON ; Seung-Pil JUNG ; Hyung-Chul LEE ; Jae-Ho CHUNG ; Eul-Sik YOON
Archives of Aesthetic Plastic Surgery 2025;31(2):35-40
Background:
The nipple is a potential source of pathogens because its lactiferous ducts act as direct conduits from the nipple–areolar complex to the breast parenchyma. Our previous studies identified breast microbiota as a factor in postoperative complications following immediate breast reconstruction using silicone implants and acellular dermal matrix. This study aimed to investigate the correlation between preoperative nipple swab microbiota and the incidence of surgical site infections (SSIs) after autologous breast reconstruction.
Methods:
We conducted a retrospective chart review of patients who underwent autologous breast reconstruction following total mastectomy. Preoperative nipple swab cultures were obtained. Patient demographics, surgical characteristics, and complication rates were compared between culture-positive and culture-negative groups. Microbiological data, including antibiotic‑resistance profiles, were collected.
Results:
Among 39 reconstructed breasts, 18 (46.9%) had positive preoperative nipple cultures. The mean duration of drain placement was significantly longer in the culture‑positive group (14.39±3.96 days) than in the culture‑negative group (12.14±2.76 days, P=0.045). Methicillin‑susceptible Staphylococcus epidermidis accounted for 55.0% of isolates. Of the four SSIs observed, three occurred in patients with positive preoperative cultures.
Conclusions
Although pathogen strains differed between preoperative and postoperative settings, obtaining preoperative nipple microflora cultures and determining antibiotic‑resistance profiles can guide immediate antibiotic selection for SSIs and enhance postoperative management.
2.Nipple swab culture profile as a potential predictor of postoperative complications in autologous breast reconstruction: a retrospective study
Sun-Hyeok KIM ; Yi-Jun MOON ; Seung-Pil JUNG ; Hyung-Chul LEE ; Jae-Ho CHUNG ; Eul-Sik YOON
Archives of Aesthetic Plastic Surgery 2025;31(2):35-40
Background:
The nipple is a potential source of pathogens because its lactiferous ducts act as direct conduits from the nipple–areolar complex to the breast parenchyma. Our previous studies identified breast microbiota as a factor in postoperative complications following immediate breast reconstruction using silicone implants and acellular dermal matrix. This study aimed to investigate the correlation between preoperative nipple swab microbiota and the incidence of surgical site infections (SSIs) after autologous breast reconstruction.
Methods:
We conducted a retrospective chart review of patients who underwent autologous breast reconstruction following total mastectomy. Preoperative nipple swab cultures were obtained. Patient demographics, surgical characteristics, and complication rates were compared between culture-positive and culture-negative groups. Microbiological data, including antibiotic‑resistance profiles, were collected.
Results:
Among 39 reconstructed breasts, 18 (46.9%) had positive preoperative nipple cultures. The mean duration of drain placement was significantly longer in the culture‑positive group (14.39±3.96 days) than in the culture‑negative group (12.14±2.76 days, P=0.045). Methicillin‑susceptible Staphylococcus epidermidis accounted for 55.0% of isolates. Of the four SSIs observed, three occurred in patients with positive preoperative cultures.
Conclusions
Although pathogen strains differed between preoperative and postoperative settings, obtaining preoperative nipple microflora cultures and determining antibiotic‑resistance profiles can guide immediate antibiotic selection for SSIs and enhance postoperative management.
3.Nipple swab culture profile as a potential predictor of postoperative complications in autologous breast reconstruction: a retrospective study
Sun-Hyeok KIM ; Yi-Jun MOON ; Seung-Pil JUNG ; Hyung-Chul LEE ; Jae-Ho CHUNG ; Eul-Sik YOON
Archives of Aesthetic Plastic Surgery 2025;31(2):35-40
Background:
The nipple is a potential source of pathogens because its lactiferous ducts act as direct conduits from the nipple–areolar complex to the breast parenchyma. Our previous studies identified breast microbiota as a factor in postoperative complications following immediate breast reconstruction using silicone implants and acellular dermal matrix. This study aimed to investigate the correlation between preoperative nipple swab microbiota and the incidence of surgical site infections (SSIs) after autologous breast reconstruction.
Methods:
We conducted a retrospective chart review of patients who underwent autologous breast reconstruction following total mastectomy. Preoperative nipple swab cultures were obtained. Patient demographics, surgical characteristics, and complication rates were compared between culture-positive and culture-negative groups. Microbiological data, including antibiotic‑resistance profiles, were collected.
Results:
Among 39 reconstructed breasts, 18 (46.9%) had positive preoperative nipple cultures. The mean duration of drain placement was significantly longer in the culture‑positive group (14.39±3.96 days) than in the culture‑negative group (12.14±2.76 days, P=0.045). Methicillin‑susceptible Staphylococcus epidermidis accounted for 55.0% of isolates. Of the four SSIs observed, three occurred in patients with positive preoperative cultures.
Conclusions
Although pathogen strains differed between preoperative and postoperative settings, obtaining preoperative nipple microflora cultures and determining antibiotic‑resistance profiles can guide immediate antibiotic selection for SSIs and enhance postoperative management.
4.Secondary nipple reconstruction using two surgical techniques
Jae-Ho CHUNG ; Da-Som KIM ; Hyun-Dong YEO ; Seung-Pil JUNG ; Seung-Ha PARK ; Eul-Sik YOON
Archives of Plastic Surgery 2021;48(6):590-598
Background:
Although the initial projection after primary nipple reconstruction is excellent, nipple projection gradually flattens in most cases due to multiple causes. Although various methods have been reported to rebuild the nipple after nipple flattening, the most effective method of secondary nipple reconstruction remains unknown. The aim of this study was to review our institution’s experiences with secondary nipple reconstruction.
Methods:
We conducted a retrospective review from March 2012 to January 2019. We performed secondary nipple reconstruction if the primary reconstructed nipple height differed by more than 6 mm from the normal nipple height. We chose the method of nipple revision according to the degree of tissue scarring and the remaining nipple projection.
Results:
We performed secondary nipple reconstruction on a total of 27 nipples, using pursestring sutures for 19 nipples and star flaps in eight nipples. The median follow-up period was 8 months (range, 6–19 months) after the final nipple reconstruction. Among the 19 nipples reconstructed using purse-string sutures, 10 (53%) demonstrated acceptable projection of more than 5 mm. Among the eight nipples reconstructed using star flaps, six (75%) showed acceptable projection of more than 5 mm. Most of the patients (73%) were satisfied (scores of 4 or 5) with the nipple reconstruction overall.
Conclusions
Few studies have presented favorable outcomes of secondary nipple reconstruction. When the star flap and purse-string suture methods were used depending on the remaining nipple height and scarring, appropriate projection could be achieved.
5.Immediate Reconstruction of Large Ptotic Breasts following Vertical Reduction Pattern Nipple-Sparing Mastectomy
Jae-Ho CHUNG ; Yong-Jae HWANG ; Seung Pil JUNG ; Seung-Ha PARK ; Eul-Sik YOON
Journal of Breast Cancer 2021;24(3):283-300
Purpose:
Women with large and/or ptotic breasts are generally not considered candidates for nipple-sparing mastectomy because of concerns regarding the high incidence of postoperative complications including ischemic complications. Therefore, we adopted a vertical skin resection technique for nipple-sparing mastectomy, and obtained satisfactory results following immediate autologous breast reconstruction. In this study, we aimed to describe our operative technique and review its outcomes.
Methods:
Between January 2010 and March 2017, immediate autologous breast reconstructions were performed in 28 patients with moderate or large ptotic breasts after nipple-sparing mastectomy using the vertical reduction pattern. Grade II ptosis was observed in 12 patients, and 16 patients were classified as having grade III ptosis.
Results:
Of the 28 patients, 21 received abdominal free flap reconstruction. In the remaining 7 patients, extended latissimus dorsi flaps were used in conjunction with anatomic implants. The mean weight of the excised breast tissue in the 2 groups was 575 g and 482 g, respectively. Satisfactory esthetic outcomes without major complications were achieved in all patients. Similar vertical reductions or mastopexies in the contralateral breast allowed better postoperative adjustment for symmetry. There was only 1 case of complete nipple necrosis; however, the problem was solved with “skin banking.” No local recurrences or distant metastases were detected at follow-up (mean 18 months, range 4 months to 6 years).
Conclusion
To enhance cosmetic outcomes in patients with large and/or ptotic breasts, the vertical skin resection pattern for nipple-sparing mastectomy can be used to achieve better breast shape while preserving the nipple-areola complex. Moreover, it can improve the esthetic outcome without compromising oncologic safety.
6.Immediate Reconstruction of Large Ptotic Breasts following Vertical Reduction Pattern Nipple-Sparing Mastectomy
Jae-Ho CHUNG ; Yong-Jae HWANG ; Seung Pil JUNG ; Seung-Ha PARK ; Eul-Sik YOON
Journal of Breast Cancer 2021;24(3):283-300
Purpose:
Women with large and/or ptotic breasts are generally not considered candidates for nipple-sparing mastectomy because of concerns regarding the high incidence of postoperative complications including ischemic complications. Therefore, we adopted a vertical skin resection technique for nipple-sparing mastectomy, and obtained satisfactory results following immediate autologous breast reconstruction. In this study, we aimed to describe our operative technique and review its outcomes.
Methods:
Between January 2010 and March 2017, immediate autologous breast reconstructions were performed in 28 patients with moderate or large ptotic breasts after nipple-sparing mastectomy using the vertical reduction pattern. Grade II ptosis was observed in 12 patients, and 16 patients were classified as having grade III ptosis.
Results:
Of the 28 patients, 21 received abdominal free flap reconstruction. In the remaining 7 patients, extended latissimus dorsi flaps were used in conjunction with anatomic implants. The mean weight of the excised breast tissue in the 2 groups was 575 g and 482 g, respectively. Satisfactory esthetic outcomes without major complications were achieved in all patients. Similar vertical reductions or mastopexies in the contralateral breast allowed better postoperative adjustment for symmetry. There was only 1 case of complete nipple necrosis; however, the problem was solved with “skin banking.” No local recurrences or distant metastases were detected at follow-up (mean 18 months, range 4 months to 6 years).
Conclusion
To enhance cosmetic outcomes in patients with large and/or ptotic breasts, the vertical skin resection pattern for nipple-sparing mastectomy can be used to achieve better breast shape while preserving the nipple-areola complex. Moreover, it can improve the esthetic outcome without compromising oncologic safety.
7.Recipient vessel selection for head and neck reconstruction: A 30-year experience in a single institution
Jae-Ho CHUNG ; Ki-Jae KIM ; Kwang-Yoon JUNG ; Seung-Kuk BAEK ; Seung-Ha PARK ; Eul-Sik YOON
Archives of Craniofacial Surgery 2020;21(5):269-275
Background:
The advance in microsurgical technique has facilitated a proper approach for reconstruction of extensive head and neck defects. For the success of free tissue reconstruction, selection of the recipient vessel is one of the most important factors. However, the vascular anatomy of this region is very complex, and a clear guideline about this subject is still lacking. In this study, we present our 30 years of experiences of free tissue reconstruction for head and neck defects.
Methods:
In this retrospective study, we analyzed a total of 138 flaps in 127 patients who underwent head and neck reconstruction using free tissue transfer following tumor resection between October 1986 to August 2019. Patients who underwent facial palsy reconstruction were excluded. Medical records including patient’s demographics, detailed operation notes, follow-up records, and photographs were collected and analyzed.
Results:
Among a total of 127 patients, 10 patients underwent a secondary operation due to cancer recurrence. The most commonly used type of flap was radial forearm flap (n= 107), followed by the anterolateral thigh flap (n= 18) and fibula flap (n= 10). With regard to recipient vessels, superior thyroid artery was most commonly used in arterial anastomosis (58.7%), and internal jugular vein (51.3%) was the first choice for venous anastomosis. The flap survival rate was 100%. Four cases of venous thrombosis were resolved with thrombectomy and re-anastomosis.
Conclusion
Superior thyroid artery and internal jugular vein were reliable choices as recipient vessels. Proper recipient vessel selection could improve the result of head and neck reconstruction.
8.Safety and Efficacy of Biodegradable Polymer-biolimus-eluting Stents (BP-BES) Compared with Durable Polymer-everolimus-eluting Stents (DP-EES) in Patients Undergoing Complex Percutaneous Coronary Intervention
Pil Sang SONG ; Kyu Tae PARK ; Min Jeong KIM ; Ki Hyun JEON ; Jin Sik PARK ; Rak Kyeong CHOI ; Young Bin SONG ; Seung Hyuk CHOI ; Jin Ho CHOI ; Sang Hoon LEE ; Hyeon Cheol GWON ; Jin Ok JEONG ; Eul Soon IM ; Sang Wook KIM ; Woo Jung CHUN ; Ju Hyeon OH ; Joo Yong HAHN
Korean Circulation Journal 2019;49(1):69-80
BACKGROUND AND OBJECTIVES: There are no data comparing clinical outcomes of complex percutaneous coronary intervention (PCI) between biodegradable polymer-biolimus-eluting stents (BP-BES) and durable polymer-everolimus-eluting stents (DP-EES). We sought to evaluate the safety and efficacy of BP-BES compared with DP-EES in patients undergoing complex PCI. METHODS: Patients enrolled in the SMART-DESK registry were stratified into 2 categories based on the complexity of PCI. Complex PCI was defined as having at least one of the following features: unprotected left main lesion, ≥2 lesions treated, total stent length >40 mm, minimal stent diameter ≤2.5 mm, or bifurcation as target lesion. The primary outcome was target lesion failure (TLF), defined as a composite of cardiac death, target vessel-related myocardial infarction (TV-MI), or target lesion revascularization (TLR) at 2 years of follow-up. RESULTS: Of 1,999 patients, 1,145 (57.3%) underwent complex PCI: 521 patients were treated with BP-BES and 624 with DP-EES. In propensity-score matching analysis (481 pairs), the risks of TLF (3.8% vs. 5.2%, adjusted hazard ratio [HR], 0.578; 95% confidence interval [CI], 0.246–1.359; p=0.209), cardiac death (2.5% vs. 2.5%, adjusted HR, 0.787; 95% CI, 0.244–2.539; p=0.689), TV-MI (0.5% vs. 0.4%, adjusted HR, 1.128; 95% CI, 0.157–8.093; p=0.905), and TLR (1.1% vs. 2.9%, adjusted HR, 0.390; 95% CI, 0.139–1.095; p=0.074) did not differ between 2 stent groups after complex PCI. CONCLUSIONS: Clinical outcomes of BP-BES were comparable to those of DP-EES at 2 years after complex PCI. Our data suggest that use of BP-BES is acceptable, even for complex PCI.
Coronary Artery Disease
;
Death
;
Drug-Eluting Stents
;
Follow-Up Studies
;
Humans
;
Myocardial Infarction
;
Percutaneous Coronary Intervention
;
Stents
9.De-epithelialized dermal flap for nipple reconstruction: A modified star flap
Su Hyun LEE ; Deok Woo KIM ; Hi Jin YOU ; Jae A JUNG ; Na Hyun HWANG ; Jae Pil YOU ; Eul Sik YOON
Archives of Plastic Surgery 2019;46(4):324-329
BACKGROUND: Multiple approaches for nipple reconstruction exist, and none is considered superior to all others. The star flap is one of the most popular methods for nipple reconstruction, but gradual height loss is a major concern. We present a new modification of the star flap that incorporates a de-epithelialized dermal flap, along with the associated surgical results. METHODS: We reviewed the medical records of patients who underwent nipple reconstruction using the modified star flap method. The design was different from the conventional star flap in that the lateral wings were changed into a trapezoidal shape and de-epithelialized dermal flaps were added. The patients were followed up at 2, 4, 6, and 12 months postoperatively, and nipple height was measured. The postoperative nipple height achieved using the modified method was compared with that obtained using the traditional method. RESULTS: From February 2013 to June 2017, 32 patients received surgery using the modified star flap, and 18 patients who underwent nipple reconstruction before 2013 comprised the conventional method group. All patients had undergone breast reconstruction with an abdominal tissue-based flap. The mean follow-up period was 14.4 months in the modified method group and 17.3 months in the conventional method group. The mean maintenance of projection at 12 months postoperatively was 56.28%±18.58% in the modified method group, and 44.23%±14.15% in the conventional method group. This difference was statistically significant (P<0.05). CONCLUSIONS: The modified method using a de-epithelialized dermal flap provides reliable maintenance of projection in patients who have undergone abdominal tissue-based breast reconstruction.
Female
;
Follow-Up Studies
;
Humans
;
Mammaplasty
;
Medical Records
;
Methods
;
Nipples
;
Surgical Flaps
10.Safety and Efficacy of Biodegradable Polymer-biolimus-eluting Stents (BP-BES) Compared with Durable Polymer-everolimus-eluting Stents (DP-EES) in Patients Undergoing Complex Percutaneous Coronary Intervention
Pil Sang SONG ; Kyu Tae PARK ; Min Jeong KIM ; Ki Hyun JEON ; Jin Sik PARK ; Rak Kyeong CHOI ; Young Bin SONG ; Seung Hyuk CHOI ; Jin Ho CHOI ; Sang Hoon LEE ; Hyeon Cheol GWON ; Jin Ok JEONG ; Eul Soon IM ; Sang Wook KIM ; Woo Jung CHUN ; Ju Hyeon OH ; Joo Yong HAHN
Korean Circulation Journal 2019;49(1):69-80
BACKGROUND AND OBJECTIVES:
There are no data comparing clinical outcomes of complex percutaneous coronary intervention (PCI) between biodegradable polymer-biolimus-eluting stents (BP-BES) and durable polymer-everolimus-eluting stents (DP-EES). We sought to evaluate the safety and efficacy of BP-BES compared with DP-EES in patients undergoing complex PCI.
METHODS:
Patients enrolled in the SMART-DESK registry were stratified into 2 categories based on the complexity of PCI. Complex PCI was defined as having at least one of the following features: unprotected left main lesion, ≥2 lesions treated, total stent length >40 mm, minimal stent diameter ≤2.5 mm, or bifurcation as target lesion. The primary outcome was target lesion failure (TLF), defined as a composite of cardiac death, target vessel-related myocardial infarction (TV-MI), or target lesion revascularization (TLR) at 2 years of follow-up.
RESULTS:
Of 1,999 patients, 1,145 (57.3%) underwent complex PCI: 521 patients were treated with BP-BES and 624 with DP-EES. In propensity-score matching analysis (481 pairs), the risks of TLF (3.8% vs. 5.2%, adjusted hazard ratio [HR], 0.578; 95% confidence interval [CI], 0.246–1.359; p=0.209), cardiac death (2.5% vs. 2.5%, adjusted HR, 0.787; 95% CI, 0.244–2.539; p=0.689), TV-MI (0.5% vs. 0.4%, adjusted HR, 1.128; 95% CI, 0.157–8.093; p=0.905), and TLR (1.1% vs. 2.9%, adjusted HR, 0.390; 95% CI, 0.139–1.095; p=0.074) did not differ between 2 stent groups after complex PCI.
CONCLUSIONS
Clinical outcomes of BP-BES were comparable to those of DP-EES at 2 years after complex PCI. Our data suggest that use of BP-BES is acceptable, even for complex PCI.

Result Analysis
Print
Save
E-mail