1.Quality of care among patients with acute heart failure at the emergency room and adherence of physicians at the University of the Philippines – Philippine General Hospital to the division of cardiovascular medicine – heart failure pathway:A retrospective cohort study.
Mark John D. Sabando ; Felix Eduardo R. Punzalan ; Frances Dominique V. Ho ; Tam Adrian P. Aya-ay ; Kevin Paul Da. Enriquez ; Marie Kirk A. Maramara ; Ronald Allan B. Roderos ; Lauren Kay M. Evangelista
Acta Medica Philippina 2026;60(2):22-32
OBJECTIVES
Clinical pathways (CPs) ensure adherence to heart failure (HF) management guidelines. To optimize quality care in a low resource setting, an evidence-based care pathway for the management of acute HF was implemented at the emergency department (ED) of the Philippine General Hospital (PGH), the designated national tertiary hospital and referral center. This study aimed to describe the characteristics of adults with acute HF admitted at the ED and evaluate the quality of care they received, measured using physician adherence to the hospital’s acute heart failure CP.
METHODSThis was a retrospective, descriptive cohort study. We reviewed the inpatient charts of all adult patients with acute HF admitted to the ED of the PGH and referred to the Division of Cardiovascular Medicine between December 1, 2022 and May 31, 2023. Quality of care was assessed based on adherence to quality indicators adapted from routine and conditional order sets detailed in the pathway. Descriptive statistics was utilized to describe patient characteristics, quality of care, and outcomes.
RESULTSTwo hundred thirty-six (236) patients were included, with a mean age of 51.8 years. Majority were male (53.4%); hypertension (61.4%) and ischemic heart disease (53.8%) were the most common comorbidities, and infection the most common precipitant of decompensation (60.6%). There were optimal adherence rates to routine orders, which included referrals to Internal Medicine and Cardiology, baseline vital signs monitoring, fluid intake and output monitoring, chest radiograph, complete blood count, blood urea nitrogen, sodium, potassium, prothrombin time, partial thromboplastin time, arterial blood gas, urinalysis, and N-terminal pro b-type natriuretic peptide. Conditional orders, such as oxygen support, focused echocardiography, thyroid - stimulating hormone, and the use of vasopressors, diuretics, and venous thromboembolism prophylactic agents, were optimally performed when warranted. However, we noted suboptimal adherence to certain resource-intensive conditional orders, such as hourly monitoring of urine output (61.4%), hooking to cardiac monitor (53.8%), and performance of 12-lead ECG within 10 minutes (56.8%). Further, only 43.9% of patients were referred to the intensive care unit. Troponin I, calcium, magnesium, and albumin were ordered in excess.
CONCLUSIONOverall adherence rate of physicians to the hospital’s Acute Heart Failure Pathway was satisfactory. Work is needed to improve adherence to hourly urine output monitoring, consistent hooking to cardiac monitor, and timely performance of 12-lead ECG – an effort that begins with expanding in-hospital diagnostic equipment and human resource supply. We recommend continuous pathway implementation with periodic evaluation and stakeholder feedback to further improve quality of care.
Human ; Male ; Female ; Middle Aged: 45-64 Yrs Old ; Adult ; Albumins ; Blood ; Blood Urea Nitrogen ; Calcium ; Cardiology ; Chart ; Charts ; Cohort Studies ; Critical Care ; Critical Pathways ; Diagnostic Equipment ; Disease ; Diuretics ; Echocardiography ; Electrocardiography ; Emergencies ; Emergency Service, Hospital ; Equipment And Supplies ; Evaluation Studies As Topic ; Feedback ; Heart ; Heart Diseases ; Heart Failure ; Hormones ; Hospitals ; Hospitals, General ; Humans ; Hypertension ; Indicators And Reagents ; Infection ; Infections ; Inpatients ; Intensive Care Units ; Internal Medicine ; Lead ; Magnesium ; Male ; Medicine ; Myocardial Ischemia ; Natriuretic Peptide, Brain ; Natriuretic Peptides ; Nitrogen ; Overall ; Oxygen ; Partial Thromboplastin Time ; Patients ; Peptides ; Philippines ; Physicians ; Potassium ; Prothrombin ; Prothrombin Time ; Quality Of Health Care ; Referral And Consultation ; Sodium ; Statistics ; Tertiary Care Centers ; Thorax ; Thromboembolism ; Thromboplastin ; Thyroid Gland ; Time ; Troponin ; Troponin I ; Universities ; Urea ; Urinalysis ; Urine ; Venous Thromboembolism ; Vital Signs ; Work ; Workforce
2.Biomechanical effects of medial and lateral translation deviations of femoral components in unicompartmental knee arthroplasty on tibial prosthesis fixation.
Jingting XU ; Jing ZHANG ; Bing ZHANG ; Wen CUI ; Weijie ZHANG ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(1):105-112
Prosthesis loosening is the leading cause of postoperative revision in unicompartmental knee arthroplasty (UKA). The deviation of medial and lateral translational installation of the prosthesis during surgery is a common clinical phenomenon and an important factor in increasing the risk of prosthesis loosening. This study established a UKA finite element model and a bone-prosthesis fixation interface micromotion prediction model. The predicted medial contact force and joint motion of the knee joint from a patient-specific lower extremity musculoskeletal multibody dynamics model of UKA were used as boundary conditions. The effects of 9 femoral component medial and lateral translational installation deviations on the Von Mises stress of the proximal tibia, the contact stress, and the micro-motion of the bone prosthesis fixation interface were quantitatively studied. It was found that compared with the neutral position (a/A of 0.492), the lateral translational deviation of the femoral component significantly increased the tibial Von Mises stress and the bone-prosthesis fixation interface contact stress. The maximum Von Mises stress and the maximum contact stress of the fixation interface increased by 14.08% and 143.15%, respectively, when a/A was 0.361. The medial translational deviation of the femoral component significantly increased the bone-prosthesis fixation interface micro-motion. The maximum value of micromotion under the conditions of femoral neutral and medial translation deviation was in the range of 20-50 μm, which is suitable for osseointegration. Therefore, based on considerations such as the micromotion range suitable for osseointegration reported in the literature, the risk of reducing prosthesis loosening, and factors that may induce pain, it is recommended that clinicians control the mounting position of the femoral component during surgery within the safe range of 0-4 mm medial translation deviation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Knee Prosthesis
;
Tibia/surgery*
;
Femur/surgery*
;
Stress, Mechanical
;
Prosthesis Failure
;
Knee Joint/surgery*
;
Prosthesis Design
3.Current status and challenges of development of acupuncture medical devices of TCM.
Renzhong KOU ; Gangqi FAN ; Kaipin GENG ; Qi LIN ; Lamei TAO ; Teng HOU ; Lin WANG
Chinese Acupuncture & Moxibustion 2025;45(7):1019-1026
The paper summarizes the authorized invention patents, device registration and the relevant published articles of acupuncture medical devices of TCM in recent 5 years, and analyzes the current status and challenges in this field. It is discovered that the optimization and substitution in diagnosis and treatment of acupuncture are involved in the development of acupuncture medical devices. The technology application of these devices are composed of traditional and emerging engineering technologies; and the theoretical guidance for their development requires the integration of traditional acupuncture principles with modern medical theories. The development of acupuncture medical devices highlights the characteristics of multidimensional integration, treatment for specific ailments, portability and wearability, painlessness and non-invasion, precision and personalization, as well as intelligent automation. Upon analysis, it is shown that in the development and product transformation of acupuncture medical devices in recent years, the theoretical principles of acupuncture of TCM have not been fully utilized yet, the transformation of patented product is low, the clinical evidence of product is insufficient, and the market competitiveness needs improvement. In the future, The theoretic guidance of acupuncture of TCM should be enhanced in the development of acupuncture medical devices, a production-education- research model with the combination of medicine and engineering be constructed, clinical verification of product be emphasized, and product development paradigms be advanced, so as to meet the demands of the medical market.
Acupuncture Therapy/trends*
;
Humans
;
Medicine, Chinese Traditional/instrumentation*
;
Equipment and Supplies
4.Design of a novel, modular, mouth retractor: A concept testing study
Miguel Sandino O. Aljibe ; Airene Maria C. Apacible ; Philip B. Fullante
Acta Medica Philippina 2025;59(Early Access 2025):1-10
BACKGROUND AND OBJECTIVES
Mouth retractors are essential in ensuring efficient yet safe exposure of the oral cavity and oropharynx. However, when applied improperly or haphazardly, retractors can cause tissue injuries and compromise patient safety. In addition, there are gaps in the usability of existing designs. This study aimed to identify the issues encountered by otorhinolaryngology surgeons in the use of commercially available mouth retractors, design and fabricate an improved retractor, and explore the use of additive manufacturing (popularly known as 3D printing) for retractor prototyping.
METHODSThe study used the United States Food and Drug Administration (US FDA) Design Control as its framework. End-user requirements from otorhinolaryngologists were collected through key informant interviews. Results were organized into a Design Input template which was used to guide the design and development process. Prototype designs were iteratively created using computer-aided design software and 3D printing. Once design specifications were satisfied, a beta prototype was fabricated and given to another cohort of otorhinolaryngologists. The participants assessed the usability of the beta prototype. System Usability Scale (SUS) was used to quantify participant's feedback.
RESULTSFive designs were created in the course of the study. The final prototype was fabricated using a Stereolithography (SLA) 3D printer. Several features were developed to address user requirements. The primary modification was to make the retractor modular to facilitate easier and shorter mounting and assembly. Gingival injury was addressed with the replacement of the maxillary alveolus hook with support bars. Five participants evaluated the beta prototype which received a mean SUS score of 75, well above the 50th percentile threshold.
CONCLUSIONThis study demonstrates the applicability of the US FDA Design Control Process in the local setting to improve the mouth retractor design. Clinical and ergonomic issues were identified and design solutions were proposed and some have been implemented in a low-fidelity prototype. Results of the small-scale usability test suggest that the present form factor can be the basis for further iterations. Future studies can implement the proposed features to address other clinical and ergonomic needs.
Human ; 3d Printing ; Printing, Three-dimensional ; Devices, Medical ; Equipment And Supplies
5.Clinical analysis of mandibular tumor resection with free fibula transplantation and implant implantation via the intraoral approach.
Jiancheng LI ; Mingming YAN ; Zhenghao MA ; Ruixue TIAN ; Xuji WANG ; Kai HU ; Lina JIANG
West China Journal of Stomatology 2025;43(2):212-219
OBJECTIVES:
To investigate the clinical application of the digital-assisted reconstruction of the mandible and tumors with free fibula transplantation and immediate implantation via the intraoral approach.
METHODS:
Twelve patients with benign mandibular tumors were collected. Three-dimensional mandibular reconstruction was performed digitally before surgery to simulate mandibular tumor resection, fibula resection and reconstruction, and implant implantation. The intraoperative resection of the mandibular tumor was conducted through the intraoral approach under the guidance of a guide plate, and fibula resection, molding, reconstruction, and oral fixation were immediately performed. Implant implantation was performed during the second phase of implant surgery and denture restoration was performed 1-2 months after surgery.
RESULTS:
The types of mandibular defects were BrownⅠ (one case), Ⅰc (four cases), Ⅱ (one case), Ⅱc(three cases), and Ⅲ (three cases). The length of the fibular bone was 12-22 cm. The number of fibular molding amputations was as follows: two cases in two segments, six cases in three segments, three cases in four segments, and one case in five segments. All of these cases underwent folding fibular reconstruction of mandibular and alveolar bone defects. A total of 44 implants were implanted, and none failed after operation.
CONCLUSIONS
The intraoral approach is a reliable method for the resection of mandibular benign tumors, with few postoperative complications and the ability to position and fix accurately the reconstructed folded fibula under digital design. The immediate implantation of the transplanted fibula does not affect the blood supply and has a high success rate. It is an effective and reliable method for the resection and reconstruction of mandibular benign tumors.
Humans
;
Fibula/transplantation*
;
Mandibular Neoplasms/surgery*
;
Mandibular Reconstruction/methods*
;
Bone Transplantation/methods*
;
Male
;
Middle Aged
;
Female
;
Mandible/surgery*
;
Adult
;
Free Tissue Flaps
;
Surgery, Computer-Assisted
6.New concepts, methods, and techniques for unilateral cleft lip repair.
West China Journal of Stomatology 2025;43(3):299-304
The unilateral cleft lip repair surgery has undergone over a century of development, marked by achievements and difficulties. Although the development of the methods for cleft lip repair has passed the period of rapid advancement, there remains an urgent need in clinical practice to further improve these methods in order to enhance clinical outcomes. This article aims to improve cleft lip repair methods by analyzing and elaborating on various aspects, including the attributes of cleft lip repair, the shift in concepts of cleft lip repair, innovations in surgical techniques, technical improvements, and classifications and repair methods for correcting secondary deformities. The analysis is based on the author's research and experience.
Cleft Lip/surgery*
;
Humans
;
Plastic Surgery Procedures/methods*
;
Surgical Flaps
7.Clinical analysis of changes in the position of the condyle and temporomandibular joint after repair of mandibular defects.
Shensui LI ; Xudong TIAN ; Yadong WU ; Weili WANG ; Zhenglong TANG
West China Journal of Stomatology 2025;43(3):422-430
OBJECTIVES:
This retrospective study aimed to investigate factors influencing positional changes of the condyle and temporomandibular joint (TMJ) following mandibular defect reconstruction with bone flaps, and to evaluate the biomechanical impacts of flap reconstruction on condylar positioning, thereby providing evidence for optimizing surgical protocols and TMJ functional rehabilitation.
METHODS:
A retrospective study was conducted on 90 patients undergoing mandibular segmental resection with immediate bone flap reconstruction at Guizhou Medical University Affiliated Stomatological Hospital (June 2019 to May 2024). After strict screening, 50 cases with complete data were analyzed. Clinical parameters (defect size, location, reconstruction method) and craniofacial CT scans at four timepoints [preoperative (T0), 7-10 days (T1), 3 months (T2), and 6 months (T3) postoperatively] were collected. Mimics 20 software facilitated 3D reconstruction for measuring TMJ anterior/posterior/superior joint spaces (Kamelchuk method) and calculating condylar position via the Pullinger index [Ln (posterior/anterior space)]. Vitral and Krisjane methods quantified mandibular linear parameters (ramus length, condylar pole distances to the sagittal plane, angulation) and glenoid fossa morphology. Statistical analyses were performed using SPSS 21.0.
RESULTS:
Mandibular defect size and location were significant factors influencing postoperative condylar position changes (P<0.05). Compared to preoperative measurements, postoperative condylar anterior, posterior, and superior joint spaces were significantly increased (P<0.001). The most pronounced anterior condylar displacement occurred within 7-10 days postoperatively (P<0.05). In patients with condyle resection, postoperative joint space and angle changes were significant; in patients with condyle preservation, only superior and anterior joint space changes were statistically significant (P<0.05). Additionally, from T1 to T2, the changes in condylar medial-lateral distance, superior joint space, and anterior joint space were negatively correlated with the preoperative condylar position. Compared with preoperative,in the T0-T1 period, condylar medial-lateral distance, posterior joint space, and articular tubercle angle changes were significantly negatively correlated with time (P<0.05). Notably, the angle between the condylar long axis and the coronal axis showed a sustained negative trend from T1 to T3 (P<0.05).
CONCLUSIONS
Condylar position changes after mandibular defect repair with bone flap reconstruction are associated with the size and location of the defect. Additionally, adaptive remodeling of the temporomandibular joint (TMJ) joint space occurs postoperatively. The phenomenon of anterior displacement of the condyle in the early postoperative period (7-10 days) shows a trend of reduction with prolonged follow-up time, and further sample size research is needed.
Humans
;
Retrospective Studies
;
Temporomandibular Joint/surgery*
;
Mandibular Condyle/surgery*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Mandibular Reconstruction/methods*
;
Mandible/surgery*
;
Surgical Flaps
;
Tomography, X-Ray Computed
;
Young Adult
;
Biomechanical Phenomena
;
Aged
;
Adolescent
;
Imaging, Three-Dimensional
8.Effect of trapezoidal and modified triangular flaps on mucosal blood supply and osteogenesis after guided bone regeneration.
Shuangzhen CHEN ; Xianyue ZHANG ; Xiaofeng JIA ; Rong XIA ; Fan JIANG
West China Journal of Stomatology 2025;43(5):679-688
OBJECTIVES:
Color doppler flow imaging (CDFI) and cone-beam computed tomography (CBCT) were utilized to evaluate changes in mucosal vascular parameters and the osteogenic effects following guided bone regeneration (GBR) in the maxillary anterior region using trapezoidal or modified triangular flaps.
METHODS:
Patients undergoing single maxillary anterior dental implant surgery with GBR were randomly allocated into two groups: a trapezoidal flap group and a modified triangular flap group. After GBR surgery, the mucosal vascular parameters at the surgical site were assessed at various time intervals (preoperative, 2 h, 1 and 3 days, and 1, 2, and 4 weeks postoperative) using CDFI. In addition, the effects of bone augmentation were evaluated through the analysis of CBCT images obtained preoperatively, 2 h, and 6 months postoperative.
RESULTS:
The buccal mucosa in the edentulous area had a lower blood flow rate than the corresponding tooth in the same jaw, and the difference was statistically significant (P<0.001). The mucosal blood flow rate in the surgical area increased compared with that in the preoperative period. The peak flow rate was recorded at 2 weeks postoperatively and then decreased to levels comparable to those of the reference tooth. A statistically significant difference was observed between the two groups (P<0.05). The buccal alveolar ridge width of the implant platform was reduced by (1.3±0.9) mm in the trapezoidal flap group and (0.9±0.7) mm in the modified triangular flap group, respectively, at 6 months postoperatively, compared with 2 h postoperative. The buccal alveolar ridge width of the 5 mm from the implant platform was reduced by (0.9±0.6) mm and (0.3±0.6) mm, respectively. The buccal alveolar ridge width of the 10 mm from the implant platform was reduced by (0.6±0.8) mm and (0.2±0.6) mm, respectively. The height of the alveolar ridge was reduced by (1.9±1.4 ) mm and (1.4±1.3) mm. The change in graft volume was (136±78 ) mm3 and (114±85) mm3. However, the differences between the two groups were not statistically significant (P>0.05).
CONCLUSIONS
When a tooth is missing, blood flow to the buccal mucosa on the side of the missing tooth is reduced. The modified triangular flap group demonstrated superior microcirculation of blood flow in the operative area after GBR of the maxillary anterior teeth. Trapezoidal and modified triangular flaps achieved the anticipated bone augmentation during bone augmentation surgery in the maxillary anterior region, with no considerable effect on the changes in alveolar bone size parameters.
Humans
;
Surgical Flaps/blood supply*
;
Bone Regeneration
;
Mouth Mucosa/blood supply*
;
Cone-Beam Computed Tomography
;
Osteogenesis
;
Maxilla/surgery*
;
Male
;
Female
;
Guided Tissue Regeneration, Periodontal/methods*
9.Design of a novel, modular, mouth retractor: A concept testing study.
Miguel Sandino O. ALJIBE ; Airene Maria C. APACIBLE ; Philip B. FULLANTE
Acta Medica Philippina 2025;59(19):43-52
BACKGROUND AND OBJECTIVES
Mouth retractors are essential in ensuring efficient yet safe exposure of the oral cavity and oropharynx. However, when applied improperly or haphazardly, retractors can cause tissue injuries and compromise patient safety. In addition, there are gaps in the usability of existing designs. This study aimed to identify the issues encountered by otorhinolaryngology surgeons in the use of commercially available mouth retractors, design and fabricate an improved retractor, and explore the use of additive manufacturing (popularly known as 3D printing) for retractor prototyping.
METHODSThe study used the United States Food and Drug Administration (US FDA) Design Control as its framework. End-user requirements from otorhinolaryngologists were collected through key informant interviews. Results were organized into a Design Input template which was used to guide the design and development process. Prototype designs were iteratively created using computer-aided design software and 3D printing. Once design specifications were satisfied, a beta prototype was fabricated and given to another cohort of otorhinolaryngologists. The participants assessed the usability of the beta prototype. System Usability Scale (SUS) was used to quantify participant's feedback.
RESULTSFive designs were created in the course of the study. The final prototype was fabricated using a Stereolithography (SLA) 3D printer. Several features were developed to address user requirements. The primary modification was to make the retractor modular to facilitate easier and shorter mounting and assembly. Gingival injury was addressed with the replacement of the maxillary alveolus hook with support bars. Five participants evaluated the beta prototype which received a mean SUS score of 75, well above the 50th percentile threshold.
CONCLUSIONThis study demonstrates the applicability of the US FDA Design Control Process in the local setting to improve the mouth retractor design. Clinical and ergonomic issues were identified and design solutions were proposed and some have been implemented in a low-fidelity prototype. Results of the small-scale usability test suggest that the present form factor can be the basis for further iterations. Future studies can implement the proposed features to address other clinical and ergonomic needs.
Human ; 3d Printing ; Printing, Three-dimensional ; Devices, Medical ; Equipment And Supplies
10.Analysis of the global competitive landscape in artificial intelligence medical device research.
Juan CHEN ; Lizi PAN ; Junyu LONG ; Nan YANG ; Fei LIU ; Yan LU ; Zhaolian OUYANG
Journal of Biomedical Engineering 2025;42(3):496-503
The objective of this study is to map the global scientific competitive landscape in the field of artificial intelligence (AI) medical devices using scientific data. A bibliometric analysis was conducted using the Web of Science Core Collection to examine global research trends in AI-based medical devices. As of the end of 2023, a total of 55 147 relevant publications were identified worldwide, with 76.6% published between 2018 and 2024. Research in this field has primarily focused on AI-assisted medical image and physiological signal analysis. At the national level, China (17 991 publications) and the United States (14 032 publications) lead in output. China has shown a rapid increase in publication volume, with its 2023 output exceeding twice that of the U.S.; however, the U.S. maintains a higher average citation per paper (China: 16.29; U.S.: 35.99). At the institutional level, seven Chinese institutions and three U.S. institutions rank among the global top ten in terms of publication volume. At the researcher level, prominent contributors include Acharya U Rajendra, Rueckert Daniel and Tian Jie, who have extensively explored AI-assisted medical imaging. Some researchers have specialized in specific imaging applications, such as Yang Xiaofeng (AI-assisted precision radiotherapy for tumors) and Shen Dinggang (brain imaging analysis). Others, including Gao Xiaorong and Ming Dong, focus on AI-assisted physiological signal analysis. The results confirm the rapid global development of AI in the medical device field, with "AI + imaging" emerging as the most mature direction. China and the U.S. maintain absolute leadership in this area-China slightly leads in publication volume, while the U.S., having started earlier, demonstrates higher research quality. Both countries host a large number of active research teams in this domain.
Artificial Intelligence
;
Bibliometrics
;
Humans
;
China
;
Equipment and Supplies
;
United States
;
Biomedical Research


Result Analysis
Print
Save
E-mail