1.Comparison of ZOOMit-DWI sequence and conventional DWI sequence in endometrial cancer.
Shixiong TANG ; Chun FU ; Hongliang CHEN ; Enhua XIAO ; Yicheng LONG ; Dujun BIAN
Journal of Central South University(Medical Sciences) 2023;48(1):76-83
OBJECTIVES:
Magnetic resonance diffusion-weighted imaging (DWI) has important clinical value in diagnosis and curative effect evaluation on endometrial carcinoma. How to improve the detection rate of endometrial small lesions by DWI is the research focus of MRI technology. This study aims to analyze the image quality of small field MRI ZOOMit-DWI sequence and conventional single-shot echo-planar imaging (SS-EPI) DWI sequence in the scanning of endometrial carcinoma, and to explore the clinical value of ZOOMit-DWI sequence.
METHODS:
A total of 37 patients with endometrial carcinoma diagnosed by operation and pathology in the Second Xiangya Hospital of Central South University from July 2019 to May 2021 were collected. All patients were scanned with MRI ZOOMit-DWI sequence and SS-EPI DWI sequence before operation. Two radiologists subjectively evaluated the anatomical details, artifacts, geometric deformation and focus definition of the 2 groups of DWI images. At the same time, the signal intensity were measured and the signal-to-noise ratio (SNR), contrast to noise ratio (CNR), and apparent diffusion coefficient (ADC) of the 2 DWI sequences were calculated for objective evaluation. The differences of subjective score, objective score and ADC value of the 2 DWI sequences were analyzed.
RESULTS:
The SNR of the ZOOMit-DWI group was significantly higher than that of the SS-EPI DWI group (301.96±141.85 vs 94.66±41.26), and the CNR of the ZOOMit-DWI group was significantly higher than that of the SS-EPI DWI group (185.05±105.45 vs 57.91±31.54, P<0.05). There was no significant difference in noise standard deviation between the ZOOMit-DWI group and the SS-EPI DWI group (P>0.05). The subjective score of anatomical detail and focus definition in the ZOOMit-DWI group was significantly higher than that of the SS-EPI DWI group (both P<0.05). The subjective score of artifacts and geometric deformation of ZOOMit-DWI group was significantly lower than that of the SS-EPI DWI group (both P<0.05). ADC had no significant difference between the ZOOMit-DWI group and the SS-EPI DWI group (P>0.05).
CONCLUSIONS
The image quality of ZOOMit-DWI is significantly higher than that of conventional SS-EPI DWI. In the MRI DWI examination of endometrial carcinoma, ZOOMit-DWI can effectively reduce the geometric deformation and artifacts of the image, which is more conducive to clinical diagnosis and treatment.
Female
;
Humans
;
Signal-To-Noise Ratio
;
Endometrial Neoplasms/diagnostic imaging*
;
Diffusion Magnetic Resonance Imaging/methods*
;
Endometrium
;
Echo-Planar Imaging/methods*
;
Reproducibility of Results
2.The value of T2 mapping for evaluating the pathological type, grade and depth of myometrial invasion in endometrial carcinoma.
Shu Jian LI ; Zan Xia ZHANG ; Jie LIU ; Wei Jian WANG ; Juan WANG ; Yong ZHANG ; Jing Liang CHENG
Chinese Journal of Oncology 2023;45(8):673-680
Objective: To investigate the value of T2 map and synthetic T2WI generated by T2 mapping in evaluating the histological type, pathological classification and depth of myometrial invasion of endometrial carcinoma (EC). Methods: Seventy-three patients with pathologically proven EC diagnosed at the First Affiliated Hospital of Zhengzhou University from December 2019 to December 2021 and 42 healthy volunteers were enrolled in the study. All subjects underwent conventional MRI, diffusion weighted imaging (DWI) and T2 mapping sequence for the pelvic cavity to test the T2 values and the apparent diffusion coefficient (ADC) of the focus nidus of the patients and the normal endometrium of the volunteers. The T2 and ADC values of EC vs normal endometrium, and those of different histological types and pathological grades were compared. The receiver operating characteristic (ROC) curves were constructed to evaluate the diagnostic performance of T2 and ADC values in determining the pathological type and classification of EC. In addition, two radiologists used synthetic T2WI combined with T2 map and conventional T2WI combined with DWI, respectively, to evaluate the depth of myometrial invasion, and compared the imaging results with the results of pathological diagnosis to evaluate the diagnostic efficacy of the two methods in determining the depth of myometrial invasion. Results: The T2 and ADC values of endometrial carcinoma were 85.0 (80.8, 92.5) ms and 0.71 (0.64, 0.77) ×10(-3) mm(2)/s, respectively, which were significantly lower than those of normal endometrium [147.4 (123.4, 176.7) ms and 1.46 (1.26, 1.76)×10(-3) mm(2)/s, respectively; both P<0.05]. The T2 values of endometrioid carcinoma (EA) [84.1 (79.5, 88.7) ms] were significantly lower than those of non-EA [98.8 (92.1, 102.8) ms; P<0.05]. There was no significant difference in ADC values between EA and non-EA (P=0.075). The T2 values of G1, G2 and G3 groups in EA were 89.1 (84.4, 94.4) ms, 83.6 (80.9, 86.2) ms, and 76.5 (71.4, 80.3) ms, respectively. There were significant differences in the T2 values between G1 vs G2, G1 vs G3, and G2 vs G3 groups, respectively (all P<0.017). Significant difference was also found in the ADC values between the G1 and G3 groups (P<0.017). The area under the ROC curve (AUC) of T2 values in distinguishing EA from non-EA was 0.867. The AUC of T2 values, ADC values and their combination in predicting high-grade EA was 0.888, 0.730 and 0.895, respectively. The accuracy of synthetic T2WI+ T2 map and conventional T2WI+ DWI in the diagnosis of deep myometrial invasion was 78.1% and 79.5%, respectively, with no significant difference (P>0.05). Conclusions: T2 mapping has great potential in preoperative evaluation of EC. The quantitative T2 value can be used in the diagnosis, pathological classification and grading of EC. The combination of synthetic T2WI and T2 map may be helpful to determine the depth of myometrial invasion.
Female
;
Humans
;
Neoplasm Invasiveness/pathology*
;
Endometrial Neoplasms/diagnostic imaging*
;
Diffusion Magnetic Resonance Imaging/methods*
;
Magnetic Resonance Imaging/methods*
;
ROC Curve
;
Retrospective Studies
3.The value of T2 mapping for evaluating the pathological type, grade and depth of myometrial invasion in endometrial carcinoma.
Shu Jian LI ; Zan Xia ZHANG ; Jie LIU ; Wei Jian WANG ; Juan WANG ; Yong ZHANG ; Jing Liang CHENG
Chinese Journal of Oncology 2023;45(8):673-680
Objective: To investigate the value of T2 map and synthetic T2WI generated by T2 mapping in evaluating the histological type, pathological classification and depth of myometrial invasion of endometrial carcinoma (EC). Methods: Seventy-three patients with pathologically proven EC diagnosed at the First Affiliated Hospital of Zhengzhou University from December 2019 to December 2021 and 42 healthy volunteers were enrolled in the study. All subjects underwent conventional MRI, diffusion weighted imaging (DWI) and T2 mapping sequence for the pelvic cavity to test the T2 values and the apparent diffusion coefficient (ADC) of the focus nidus of the patients and the normal endometrium of the volunteers. The T2 and ADC values of EC vs normal endometrium, and those of different histological types and pathological grades were compared. The receiver operating characteristic (ROC) curves were constructed to evaluate the diagnostic performance of T2 and ADC values in determining the pathological type and classification of EC. In addition, two radiologists used synthetic T2WI combined with T2 map and conventional T2WI combined with DWI, respectively, to evaluate the depth of myometrial invasion, and compared the imaging results with the results of pathological diagnosis to evaluate the diagnostic efficacy of the two methods in determining the depth of myometrial invasion. Results: The T2 and ADC values of endometrial carcinoma were 85.0 (80.8, 92.5) ms and 0.71 (0.64, 0.77) ×10(-3) mm(2)/s, respectively, which were significantly lower than those of normal endometrium [147.4 (123.4, 176.7) ms and 1.46 (1.26, 1.76)×10(-3) mm(2)/s, respectively; both P<0.05]. The T2 values of endometrioid carcinoma (EA) [84.1 (79.5, 88.7) ms] were significantly lower than those of non-EA [98.8 (92.1, 102.8) ms; P<0.05]. There was no significant difference in ADC values between EA and non-EA (P=0.075). The T2 values of G1, G2 and G3 groups in EA were 89.1 (84.4, 94.4) ms, 83.6 (80.9, 86.2) ms, and 76.5 (71.4, 80.3) ms, respectively. There were significant differences in the T2 values between G1 vs G2, G1 vs G3, and G2 vs G3 groups, respectively (all P<0.017). Significant difference was also found in the ADC values between the G1 and G3 groups (P<0.017). The area under the ROC curve (AUC) of T2 values in distinguishing EA from non-EA was 0.867. The AUC of T2 values, ADC values and their combination in predicting high-grade EA was 0.888, 0.730 and 0.895, respectively. The accuracy of synthetic T2WI+ T2 map and conventional T2WI+ DWI in the diagnosis of deep myometrial invasion was 78.1% and 79.5%, respectively, with no significant difference (P>0.05). Conclusions: T2 mapping has great potential in preoperative evaluation of EC. The quantitative T2 value can be used in the diagnosis, pathological classification and grading of EC. The combination of synthetic T2WI and T2 map may be helpful to determine the depth of myometrial invasion.
Female
;
Humans
;
Neoplasm Invasiveness/pathology*
;
Endometrial Neoplasms/diagnostic imaging*
;
Diffusion Magnetic Resonance Imaging/methods*
;
Magnetic Resonance Imaging/methods*
;
ROC Curve
;
Retrospective Studies
4.Long-term outcomes of magnetic resonance imaging-invisible endometrial cancer.
Hyun Jin CHOI ; Sunyoung LEE ; Byung Kwan PARK ; Tae Joong KIM ; Chan Kyo KIM ; Jung Jae PARK ; Chel Hun CHOI ; Yoo Young LEE ; Jeong Won LEE ; Duk Soo BAE ; Byoung Gie KIM
Journal of Gynecologic Oncology 2016;27(4):e38-
OBJECTIVE: Magnetic resonance imaging (MRI) is useful for staging endometrial cancer. The treatment and prognosis of MRI-invisible endometrial cancer remain unclear. The purpose of this study was to retrospectively evaluate the long-term outcomes of patients with MRI-invisible endometrial cancer. METHODS: Between February 1995 and December 2011, we reviewed the medical records of 433 patients with endometrial cancer, which was staged IA on MRI. Of these patients, 89 had MRI-invisible cancer and 344 had MRI-visible cancer. Both cancers were treated with simple hysterectomy with or without lymph node dissection according to the surgeon's decision. Both cancers were compared regarding pathologic findings, recurrence rates, and survival rates. RESULTS: The median sizes of MRI-invisible and MRI-visible cancers were 4 mm (0 to 40 mm) and 20 mm (0 to 89 mm), respectively (p<0.001). Myometrial invasion of these groups were detected in 20.2% (18/89) and 56.7% (195/344), respectively (p<0.001). Lymphadenectomy and follow-up imaging revealed no lymph node metastasis in patients with MRI-invisible cancers, while those revealed in 4.7% (16/344) of patients with MRI-visible cancers (p=0.052). The recurrence rates of MRI-invisible and MRI-visible cancers were 1.1% (1/89) and 7.8% (27/344), respectively (p=0.026). The recurrence-free survival rates of these groups were 98.9% (88/89) and 91.6% (315/344), respectively (p=0.022). CONCLUSION: MRI-invisible endometrial cancer can be treated with less invasive surgery because of its lower tumor burden and better prognosis. This cancer may not require lymphadenectomy because of no metastasis or recurrence in lymph nodes.
Adult
;
Aged
;
Aged, 80 and over
;
Endometrial Neoplasms/diagnostic imaging/*pathology
;
Female
;
Humans
;
Lymphatic Metastasis
;
*Magnetic Resonance Imaging
;
Middle Aged
;
Retrospective Studies
5.Long-term outcomes of magnetic resonance imaging-invisible endometrial cancer.
Hyun Jin CHOI ; Sunyoung LEE ; Byung Kwan PARK ; Tae Joong KIM ; Chan Kyo KIM ; Jung Jae PARK ; Chel Hun CHOI ; Yoo Young LEE ; Jeong Won LEE ; Duk Soo BAE ; Byoung Gie KIM
Journal of Gynecologic Oncology 2016;27(4):e38-
OBJECTIVE: Magnetic resonance imaging (MRI) is useful for staging endometrial cancer. The treatment and prognosis of MRI-invisible endometrial cancer remain unclear. The purpose of this study was to retrospectively evaluate the long-term outcomes of patients with MRI-invisible endometrial cancer. METHODS: Between February 1995 and December 2011, we reviewed the medical records of 433 patients with endometrial cancer, which was staged IA on MRI. Of these patients, 89 had MRI-invisible cancer and 344 had MRI-visible cancer. Both cancers were treated with simple hysterectomy with or without lymph node dissection according to the surgeon's decision. Both cancers were compared regarding pathologic findings, recurrence rates, and survival rates. RESULTS: The median sizes of MRI-invisible and MRI-visible cancers were 4 mm (0 to 40 mm) and 20 mm (0 to 89 mm), respectively (p<0.001). Myometrial invasion of these groups were detected in 20.2% (18/89) and 56.7% (195/344), respectively (p<0.001). Lymphadenectomy and follow-up imaging revealed no lymph node metastasis in patients with MRI-invisible cancers, while those revealed in 4.7% (16/344) of patients with MRI-visible cancers (p=0.052). The recurrence rates of MRI-invisible and MRI-visible cancers were 1.1% (1/89) and 7.8% (27/344), respectively (p=0.026). The recurrence-free survival rates of these groups were 98.9% (88/89) and 91.6% (315/344), respectively (p=0.022). CONCLUSION: MRI-invisible endometrial cancer can be treated with less invasive surgery because of its lower tumor burden and better prognosis. This cancer may not require lymphadenectomy because of no metastasis or recurrence in lymph nodes.
Adult
;
Aged
;
Aged, 80 and over
;
Endometrial Neoplasms/diagnostic imaging/*pathology
;
Female
;
Humans
;
Lymphatic Metastasis
;
*Magnetic Resonance Imaging
;
Middle Aged
;
Retrospective Studies
6.Time-lapse imaging of sentinel lymph node using indocyanine green with near-infrared fluorescence imaging in early endometrial cancer.
Hyun Jin CHOI ; Tae Joong KIM ; Yoo Young LEE ; Jeong Won LEE ; Byoung Gie KIM ; Duk Soo BAE
Journal of Gynecologic Oncology 2016;27(3):e27-
OBJECTIVE: Indocyanine green with near-infrared fluorescence imaging (NIR-ICG) is a new tracer modality in the limelight used for lymphatic mapping. The advantage of this method is to provide real-time image during surgery. To use ICG for image guided lymph node dissection, a surgeon needs to know initial appearing time and duration. METHODS: A 52-year-old woman undertook surgery diagnosed with endometrial cancer. She had no past medical history and her body mass index was 25.3 kg/m2. Preoperative magnetic resonance imaging examination revealed 2.7 cm sized cancerous mass in the endometrial cavity with superficial myometrial invasion without lymph node enlargement. Four mL (1.25 mg/mL) of ICG solution was prepared for injection. For each site, 1 mL of solution was injected superficially, 2-3 mm into the cervical submucosa and another 1 mL was injected deep, 1-2 cm into the stroma of the cervix. We recorded video with 30° 10 mm scope equipped with a specific lens and light source emitting both visible and NIR light (KARL STORZ GmbH & Co. KG, Tuttlingen, Germany). RESULTS: Pelvic lymph node was visualized from around 5 minutes. ICG was dispersed into organs after hysterectomy (53 minutes after ICG injection), yet we could clearly identify sentinel lymph node (SLN). Pathology revealed endometriod adenocarcinoma grade I, myometrial invasion with less than half of myometrium and no lymph node metastasis. CONCLUSION: Cervical injection of ICG provides good visualization of SLN from 5 minutes to over an hour. Our film gives an idea about time management to make a plan for surgery and not to miss SNLs.
Adenocarcinoma/diagnostic imaging/*pathology
;
Coloring Agents/*therapeutic use
;
Endometrial Neoplasms/diagnostic imaging/*pathology
;
Female
;
Humans
;
Indocyanine Green/*therapeutic use
;
Lymphatic Metastasis/diagnostic imaging
;
Middle Aged
;
Optical Imaging/methods
;
Sentinel Lymph Node/*diagnostic imaging
;
Time-Lapse Imaging/methods
7.Role of transvaginal contrast-enhanced ultrasound in the early diagnosis of endometrial carcinoma.
Ying LIU ; Jia-Wei TIAN ; Yi XU ; Wen CHENG
Chinese Medical Journal 2012;125(3):416-421
BACKGROUNDEndometrial carcinoma is one of the most common gynecological malignancies among women. Early diagnosis and correct preoperative evaluation of myometrial invasion are necessary to improve the prognosis. This study aimed to determine whether features and time-intensity curves (TIC) of transvaginal contrast-enhanced ultrasound (CEUS) differ from those of conventional ultrasound for endometrial carcinoma, and to further explore the clinical role of transvaginal CEUS in the early diagnosis of endometrial carcinoma.
METHODSForty women with a normal uterus and seventy-nine patients with endometrial carcinoma were examinedby the transvaginal CEUS with SonoVue (Bracco, Imaging B.V, Switzerland). The enhancement patterns and TIC of lesions were analyzed. The results of CEUS were compared with those of conventional ultrasound and pathology.
RESULTSIn the early and late enhanced stages, the intensity of enhancement of the normal endometrium was always lower than that in the myometrium, and the boundary between normal endometrium and myometrium was clear. A total of 65.8% (52/79) of lesions presented with inhomogeneous enhancement, 34.2% (27/79) presented with homogeneous enhancement; 60.8% (48/79) presented with hyperechoic enhancement, 27.8% (22/79) presented with isoechoic enhancement, and 11.4% (9/79) presented with hypoechoic enhancement. The average arrival time, time to peak, rise time, half-wash out time of lesions were shorter than of normal endometrium (P < 0.05). The average peak intensity, relative rise in intensity, half-wash out intensity of lesions were higher than of normal endometrium (P < 0.05). There were 49 (must be and may be present) cases of endometrial carcinoma by ultrasound (US); 24 cases were consistent with pathology results, 16 cases were underestimated and 9 cases were overestimated. There were 72 (must be and may be present) cases of endometrial carcinoma by CEUS; 53 cases were consistent with pathology results, 12 cases were underestimated and 7 cases were overestimated. The qualitative diagnosis of endometrial carcinoma by CEUS was more accurate and definite than that by US (P < 0.01).
CONCLUSIONSBy evaluating contrast-enhanced patterns and analyzing TIC, we found that CEUS can increase the accuracy of ultrasound qualitative diagnosis of endometrial carcinoma. CEUS shows lesions more clearly than conventional ultrasound, which is an advantage in evaluating the encroachment of endometrial carcinoma.
Adult ; Aged ; Contrast Media ; Early Diagnosis ; Endometrial Neoplasms ; diagnosis ; Female ; Humans ; Middle Aged ; Myometrium ; diagnostic imaging ; pathology ; Ultrasonography
8.Value of (18)F-FDG imaging and serum tumor markers in the diagnosis of recurrent endometrial carcinoma.
Qian WANG ; Lian HONG ; Jian-liu WANG ; Ming-gang YUE ; He-bei LI ; Yuan LI
Chinese Journal of Oncology 2010;32(4):300-303
OBJECTIVEBoth (18)F-fluorodeoxyglucose (FDG) imaging and serum tumor marker measurements can be used in the post-therapy surveillance of recurrent endometrial carcinoma, but the relationship between those two methods has not been demonstrated yet. The purpose of this study was to compare the diagnostic efficiency of (18)F-FDG imaging and serum tumor marker measurements in the diagnosis of recurrent endometrial carcinoma, as well as to analyze the correlation between those two methods.
METHODSThirty-five patients with histopathologically confirmed endometrial carcinoma and suspected to have recurrent disease during post-therapy surveillance were included in this study. (18)F-FDG images from the thorax to the pelvis were obtained in all patients by using GE-Millennium VG Hawkeye system, and the abnormal FDG uptake was judged as tumor recurrence. Serum CA-125 and CP-2 were also measured for each patient by enzyme-linked immunoassay, and a cutoff value of 35 U/ml was taken as the criteria for predicting tumor recurrence. Based on the final clinical diagnosis, the efficiency of tumor markers (CA-125, CP-2) and (18)F-FDG imaging in the diagnosis of recurrent tumor was evaluated.
RESULTSAccording to the histopathological diagnosis or follow-up examinations, tumor recurrence was confirmed in 13 of the 35 patients. Elevated serum level of CA-125 was found in 7 patients, serum CP-2 was increased in 9, and (18)F-FDG imaging was positive in 15. The diagnostic sensitivity, specificity and accuracy were 53.8%, 100% and 82.9% for the serum CA-125; 38.5%, 81.0% and 65.7% for the serum CP-2, and 100%, 90.9% and 94.3% for the (18)F-FDG imaging, respectively. The diagnostic coincidence rate between the (18)F-FDG imaging and serum CA-125 was 77.1% (Kappa = 0.50, P = 0.001), but no significant correlation was found between the (18)F-FDG imaging and serum CP-2. In the patients with true positive (18)F-FDG imaging, a positive correlation between the tumor volume and the serum CA-125 value was found (r = 0.89, P < 0.001), but no correlation was found between the tumor uptake and the serum CA-125 values.
CONCLUSIONFor the post-therapy surveillance of patients with endometrial carcinoma, serum CA-125 is a high specific tumor marker for diagnosing recurrent disease and better than CP-2, but (18)F-FDG imaging is better than CA-125, and there is a positive correlation between tumor volume and serum CA-125 value.
Adenocarcinoma ; blood ; diagnosis ; diagnostic imaging ; pathology ; Adult ; Aged ; Biomarkers, Tumor ; blood ; CA-125 Antigen ; blood ; Cystadenocarcinoma, Serous ; blood ; diagnosis ; diagnostic imaging ; pathology ; DNA-Binding Proteins ; blood ; Endometrial Neoplasms ; blood ; diagnosis ; diagnostic imaging ; pathology ; Female ; Fluorodeoxyglucose F18 ; Follow-Up Studies ; Humans ; Middle Aged ; Neoplasm Recurrence, Local ; blood ; diagnosis ; diagnostic imaging ; pathology ; Positron-Emission Tomography ; Radiopharmaceuticals ; Sensitivity and Specificity ; Transcription Factors ; blood
9.Detection of Recurrence by 18F-FDG PET in Patients with Endometrial Cancer Showing No Evidence of Disease.
Sang Young RYU ; Kidong KIM ; Younha KIM ; Sang Il PARK ; Beob Jong KIM ; Moon Hong KIM ; Seok Cheol CHOI ; Eui Don LEE ; Kyung Hee LEE ; Byung Il KIM
Journal of Korean Medical Science 2010;25(7):1029-1033
This study assessed the feasibility of F-18-fluorodeoxyglucose positron-emission tomography (18F-FDG PET) in the post-therapy surveillance for patients with endometrial cancer showing no evidence of disease (NED). From April 1997 to June 2007, 127 patients with endometrial cancer showing NED were performed 18F-FDG PET scan. The feasibility of 18F-FDG PET for the early detection of recurrence in patients with endometrial cancer was evaluated retrospectively. Of the 127 patients, 32 patients showed positive lesions on 18F-FDG PET scan. Nineteen (19/127 cases, 15%) of them were confirmed to have a recurrence clinically or histologically. The sensitivity, specificity and positive and negative predictive value of 18F-FDG PET for detecting recurrences in patients with endometrial cancer were 100%, 88%, 59% and 100%, respectively. In conclusion, 18F-FDG PET may be a useful method for the post-therapy surveillance in patients with endometrial cancer.
Adult
;
Aged
;
Endometrial Neoplasms/*diagnosis/pathology/*radionuclide imaging
;
Female
;
Fluorodeoxyglucose F18/*diagnostic use
;
Humans
;
Middle Aged
;
Neoplasm Recurrence, Local/*diagnosis/pathology/*radionuclide imaging
;
Positron-Emission Tomography/*methods
;
Predictive Value of Tests
;
Retrospective Studies
;
Sensitivity and Specificity
10.Establishment of a rabbit model bearing transplanted endometrial carcinoma and magnetic resonance imaging features of the metastatic lymph nodes.
Gang DUAN ; Yi-kai XU ; Ping DUAN
Journal of Southern Medical University 2008;28(9):1716-1719
OBJECTIVETo establish a rabbit model bearing endometrial carcinoma and observe the magnetic resonance imaging (MRI) features of the metastatic lymph nodes.
METHODSVX(2) tumor grafts were orthotopically embedded into the endometrium of the rabbits. Three weeks after the implantation, the tumor and the metastatic retroperitoneal lymph nodes were examined with MRI, and the signal intensities and the size of the lymph nodes were compared with those in normal rabbits.
RESULTSOrthotopic tumor growth was observed in all the rabbits. Tumor infiltration of the serosa and retroperitoneal lymph node metastasis occurred 3 weeks after tumor implantation. MRI demonstrated obviously lymph node enlargement in the tumor-bearing rabbits as compared with those of normal rabbits, while the signal intensity of the lymph nodes were comparable between them.
CONCLUSIONThe endometrial carcinoma in this rabbit model well simulate the metastatic behavior of human endometrial carcinoma, and may serve as a good model for testing the efficacy of the contrast agents for MRI of the lymph nodes.
Animals ; Cell Line, Tumor ; Disease Models, Animal ; Endometrial Neoplasms ; pathology ; Female ; Lymph Nodes ; diagnostic imaging ; Lymphatic Metastasis ; Magnetic Resonance Imaging ; Neoplasm Transplantation ; Rabbits ; Radiography

Result Analysis
Print
Save
E-mail