1.Identifying COVID-19 confirmed patients at elevated risk for mortality and need of mechanical ventilation using a novel criteria for Hyperinflammatory Syndrome: A retrospective cohort, single-center, validation study
Jayvee Rho-an D. Descalsota ; Abdul Walli R. Cana ; Inofel I. Chin ; Jessie F. Orcasitas
Acta Medica Philippina 2025;59(3):104-115
BACKGROUND AND OBJECTIVES
A mounting evidence links dysregulated immune response to cases of fatal pneumonia seen in COVID-19 infection. We aimed to validate the COVID-19-associated Hyperinflammatory Syndrome (cHIS) score, a novel clinical tool devised to identify those at risk for adverse outcomes, in a local population and investigate the relationship of cHIS score taken at admission and the risk of mortality and the need of mechanical ventilation.
METHODSThis retrospective cohort study analyzed the sociodemographic, clinical, and laboratory data of 1,881 COVID-19 patients admitted at a tertiary hospital in Davao City, Philippines from January to December 2021. We calculated the cHIS score, composed of six clinical and laboratory criteria from admission, and used multivariate logistic regression to determine the risk of mortality and need of mechanical ventilation.
RESULTSThe cHIS score taken at admission, regardless of cut-off value, was a significant predictor of mortality (OR 0.979 [99% CI 0.894-1.064]) and need of mechanical ventilation (OR 0.586 [99% CI 0.4975-0.6745]). Using the Youden Index, a cut-off cHIS score of 3 or more was a better predictor of mortality (sensitivity, 88.59%; specificity, 71.72%), and a cut-off score of 2 or more was a better predictor of need of mechanical ventilation (sensitivity, 84.02%; specificity, 70.82%) than other cutoff cHIS scores.
CONCLUSIONAmong COVID-19 patients, the cHIS score at admission correlated with the risk of mortality and the need of mechanical ventilation. Cutoff scores of 3 and 2 had the optimal sensitivities and specificities to predict the risk of mortality and the need of mechanical ventilation, respectively.
Human ; Covid-19 ; Inflammation ; Mortality ; Mechanical Ventilation ; Respiration, Artificial ; Cytokine Storm ; Cytokine Release Syndrome
2.A profile of out-of-hospital cardiac arrest in Amang Rodriguez Memorial Medical Center: A prospective cohort study
Donna Erika E. De Jesus ; Ken P. Manongas
Philippine Journal of Internal Medicine 2025;63(1):45-50
INTRODUCTION
Cardiac arrest occurs when abrupt cessation of cardiac function results in loss of effective circulation and complete cardiovascular collapse. For every minute of cardiac arrest without early intervention (cardiopulmonary resuscitation [CPR], defibrillation), chances of survival drop by 7 – 10%. It is crucial that CPR be initiated within 4 – 6 minutes to avoid brain death. Most out-of-hospital cardiac arrests (OHCA) occur in a residential setting where access to trained personnel and equipment is not readily available, resulting in poor victim outcomes.
METHODSThis descriptive study was done from August to November 2021 using a prospective cohort design. Participants of the study include adult patients aged 18 years and above brought to the emergency room who suffered from out-ofhospital cardiac arrest. Out of the total 102 cases of OHCA, 63 participants were included in the study. Descriptive statistics was used to summarize the demographic and clinical characteristics of the patients.
RESULTSForty-three subjects were male patients, comprising the majority at 73.02%. Hypertension was identified as the top comorbidity, followed by diabetes mellitus, heart failure, and chronic kidney disease (CKD). Medical causes of arrest were identified in 96.83% of the cases. 90.48% of cardiac arrests occurred at home. Only 26 patients (41.27%) received prehospital intervention before ER arrival, comprising only hands-on CPR. Twenty-three of these were performed by individuals with background knowledge of CPR. 60.32% were brought via self-conduction, the remainder by ambulances, which were noted to have no available equipment necessary to provide proper resuscitation. The average travel time from dispatch to
ER arrival is 20 minutes.
Overall survival of OHCA in our local setting remains dismal, as the return of spontaneous circulation was not achieved in any of the patients. The small number of patients having pre-hospital CPR indicates the need for emphasis on training and community education.
Human ; Out-of-hospital Cardiac Arrest ; Cardiopulmonary Resuscitation ; Survival
3.Accuracy of the Brighton Pediatric Early Warning Score in detecting clinical deterioration events among pediatric patients: Retrospective cohort study
Giselle Godin ; Mae Anne Cansino-Valeroso ; Diana M. Dadia
Southern Philippines Medical Center Journal of Health Care Services 2025;11(1):8-8
BACKGROUND
Pediatric Early Warning Scores (PEWS) help identify children at risk of clinical deterioration, but their accuracy across diverse settings, populations, interventions, and outcomes remains unexplored.
OBJECTIVETo determine the accuracy of PEWS in detecting clinical deterioration events (CDE) among pediatric patients seen at the emergency department (ED).
DESIGNRetrospective cohort study.
PARTICIPANTSPediatric patients aged 1 month to 18 years seen at the ED.
SETTINGSouthern Philippines Medical Center Emergency Department, Davao City, Philippines from January 2021 to December 2022.
MAIN OUTCOME MEASURESArea under the curve (AUC) of PEWS in detecting CDE; Brighton PEWS optimal cut-off and its sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (+LR), and negative likelihood ratio (-LR).
MAIN RESULTSAmong the 345 patients, 56 experienced CDE and 289 did not. Patients with CDE had significantly lower median age (1.00 year vs 5.00 years; p < 0.001), oxygen saturation (93.00% vs 98.00%; p < 0.001), and pediatric Glasgow Coma Scale scores (8.00 vs 15.00; p < 0.0001) compared to those without CDE. Heart rate (135.00 vs 111.00 beats per minute; p < 0.001), and respiratory rate (32.50 vs 24.00 breaths per minute; p < 0.001) were significantly higher in patients with CDE. The two groups also differed significantly in terms of comorbidity distribution (p < 0.001) and diagnosis (p < 0.001). The AUC of Brighton PEWS was 0.9064 (95% CI 0.8716 to 0.9357), with an optimal cut-off score of ≥4.00. This threshold yielded 76.79% sensitivity, 88.58% specificity, 56.60% PPV, 95.20% NPV, 6.72 LR+, and 0.26 LR-.
CONCLUSIONThe Brighton PEWS demonstrates strong diagnostic accuracy in predicting CDE among pediatric patients. A cut-off score of ≥4.00 offers a balanced combination of sensitivity, specificity, and likelihood ratios for ED application.
Human ; Emergency Departments ; Emergency Service, Hospital ; Resuscitation ; Mortality
4.Development and Safety Trial of the OstreaVent2™ prototype for mechanically ventilated adult patients
Maria Esterlita T. Villanueva-Uy ; Enrique M. Ostrea, Jr. ; Alexander P. Paran ; Manuel C. Jorge ; Kriselda Karlene G. Tan ; Herbert G. Uy ; E. Vincent S. Faustino ; Robert O. Dizon
Acta Medica Philippina 2024;58(7):27-40
Background:
With the surge of COVID-19 infections, there were concerns about shortage of mechanical ventilator in several countries including the Philippines.
Objective:
To transform a locally made, low-cost, neonatal ventilator into a volume- and pressure-controlled, adult ventilator and to determine its safe use among ventilated, adult patients at the Philippine General Hospital.
Methods:
The modification of the neonatal ventilator (OstreaVent1) to the adult OstreaVent2 was based on the critical need for adult ventilators, in volume or pressure mode, in the Philippines due to the COVID-19 pandemic. The adult ventilator settings were calibrated and tested for two days to check for consistency and tolerance and then submitted to a third party for certification. Once certified, a safety trial of 10 stable adult patients on mechanical ventilator was conducted. The patients were placed on the OstreaVent2 for four hours while ventilator parameters, patient’s vital signs, and arterial blood gases were monitored at baseline, during, and after placement on the OstreaVent2. A poststudy chest radiograph was also done to rule out pulmonary complications, particularly atelectasis and pneumothorax.
Results:
The prototype OstreaVent2 received an FDA Certification for Medical Listing after passing its thirdparty
certification. Ten patients (60% male) recruited in the study had a mean age of 39.1 ± 11.6 years. Half of the patients had a diagnosis of non-COVID-19 pneumonia. During the 4-hour study period, the patients while on the OstreaVent2, had stable ventilator settings and most of the variabilities were within the acceptable tolerances. Vital signs were stable and arterial blood gases were within normal limits. One patient developed alar flaring which was relieved by endotracheal tube suctioning. No patient was withdrawn from the study. One patient who was already transferred out of the ICU subsequently deteriorated and died three days after transfer to the stepdown unit from a non-ventilator related cause.
Conclusion
The new OstreaVent2 is safe to use among adults who need ventilator support. Variabilities in
the ventilator’s performance were within acceptable tolerances. Clinical and blood gas measurements of the patients were stable while on the ventilator.
Respiration, Artificial
5.Identifying COVID-19 confirmed patients at elevated risk for mortality and need of mechanical ventilation using a novel criteria for Hyperinflammatory Syndrome: A retrospective cohort, single-center, validation study
Jayvee Rho-An D. Descalsota ; Abdul Walli R. Cana ; Inofel I. Chin ; Jessie F. Orcasitas
Acta Medica Philippina 2024;58(Early Access 2024):1-12
Background and Objectives:
A mounting evidence links dysregulated immune response to cases of fatal pneumonia seen in COVID-19 infection. We aimed to validate the COVID-19-associated Hyperinflammatory Syndrome (cHIS) score, a novel clinical tool devised to identify those at risk for adverse outcomes, in a local population and investigate the relationship of cHIS score taken at admission and the risk of mortality and the need of mechanical ventilation
Methods:
This retrospective cohort study analyzed the sociodemographic, clinical, and laboratory data of 1,881 COVID-19 patients admitted at a tertiary hospital in Davao City, Philippines from January to December 2021. We calculated the cHIS score, composed of six clinical and laboratory criteria from admission, and used multivariate logistic regression to determine the risk of mortality and need of mechanical ventilation.
Results:
The cHIS score taken at admission, regardless of cut-off value, was a significant predictor of mortality (OR 0.979 [99% CI 0.894-1.064]) and need of mechanical ventilation (OR 0.586 [99% CI 0.4975-0.6745]). Using the Youden Index, a cut-off cHIS score of 3 or more was a better predictor of mortality (sensitivity, 88.59%; specificity, 71.72%), and a cut-off score of 2 or more was a better predictor of need of mechanical ventilation (sensitivity, 84.02%; specificity, 70.82%) than other cut-off cHIS scores.
Conclusion
Among COVID-19 patients, the cHIS score at admission correlated with the risk of mortality and the need of mechanical ventilation. Cutoff scores of 3 and 2 had the optimal sensitivities and specificities to predict the risk of mortality and the need of mechanical ventilation, respectively.
COVID-19
;
Inflammation
;
Mortality
;
Respiration, Artificial
;
Cytokine Release Syndrome
6.Etiology and incidence of infection in Mechanically Ventilated Medical Intensive Care Unit Patients in a Tertiary Care Hospital
Ashaq Parrey ; Mohd. Ashraf ; Abir Ajaz ; Mohd Ismail ; Basharat Kasana ; Manzoor Koka ; Mir Sadaqat
Philippine Journal of Internal Medicine 2024;62(1):291-294
Introduction:
Intensive care unit (ICU) patients are at the greatest risk of acquiring nosocomial infections, partly because
of their serious underlying disease, but also by exposure to life-saving invasive procedures. Hospital-acquired infections
increase patient morbidity, increase the length of hospital stay and hospital costs, and also increases mortality rate. The
basic knowledge of organisms infecting ICU patients is very important to empirically select appropriate antibiotics, so that
the most likely infecting organisms are addressed.
Objective:
The aim of the study was to find out the etiologic agents causing infection in medical intensive care unit patients.
Results
In our study of 289 patients, 180 (62.3%) showed a growth of organism during the stay in ICU. The most common
site of infection was the respiratory tract in 138 patients (47.8%) with 60 patients (20.8%) showing Acinetobacter baumannii.
Cross Infection
;
Intensive Care Units
;
Acinetobacter baumannii
;
Respiration, Artificial
7.Patient outcomes after neonatal tracheotomy: A retrospective case-control study.
Jie YU ; Fengzhen ZHANG ; Fei JIN ; Jingwen WENG ; Yaguang PENG ; Jingjing ZHOU ; Yan CHEN ; Jie ZHANG ; Mingyan HEI
Chinese Medical Journal 2023;136(10):1246-1248
8.Low diastolic blood pressure and adverse outcomes in inpatients with acute exacerbation of chronic obstructive pulmonary disease: A multicenter cohort study.
Chen ZHOU ; Qun YI ; Yuanming LUO ; Hailong WEI ; Huiqing GE ; Huiguo LIU ; Xianhua LI ; Jianchu ZHANG ; Pinhua PAN ; Mengqiu YI ; Lina CHENG ; Liang LIU ; Jiarui ZHANG ; Lige PENG ; Adila AILI ; Yu LIU ; Jiaqi PU ; Haixia ZHOU
Chinese Medical Journal 2023;136(8):941-950
BACKGROUND:
Although intensively studied in patients with cardiovascular diseases (CVDs), the prognostic value of diastolic blood pressure (DBP) has little been elucidated in patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD). This study aimed to reveal the prognostic value of DBP in AECOPD patients.
METHODS:
Inpatients with AECOPD were prospectively enrolled from 10 medical centers in China between September 2017 and July 2021. DBP was measured on admission. The primary outcome was all-cause in-hospital mortality; invasive mechanical ventilation and intensive care unit (ICU) admission were secondary outcomes. Least absolute shrinkage and selection operator (LASSO) and multivariable Cox regressions were used to identify independent prognostic factors and calculate the hazard ratio (HR) and 95% confidence interval (CI) for adverse outcomes.
RESULTS:
Among 13,633 included patients with AECOPD, 197 (1.45%) died during their hospital stay. Multivariable Cox regression analysis showed that low DBP on admission (<70 mmHg) was associated with increased risk of in-hospital mortality (HR = 2.16, 95% CI: 1.53-3.05, Z = 4.37, P <0.01), invasive mechanical ventilation (HR = 1.65, 95% CI: 1.32-2.05, Z = 19.67, P <0.01), and ICU admission (HR = 1.45, 95% CI: 1.24-1.69, Z = 22.08, P <0.01) in the overall cohort. Similar findings were observed in subgroups with or without CVDs, except for invasive mechanical ventilation in the subgroup with CVDs. When DBP was further categorized in 5-mmHg increments from <50 mmHg to ≥100 mmHg, and 75 to <80 mmHg was taken as reference, HRs for in-hospital mortality increased almost linearly with decreased DBP in the overall cohort and subgroups of patients with CVDs; higher DBP was not associated with the risk of in-hospital mortality.
CONCLUSION:
Low on-admission DBP, particularly <70 mmHg, was associated with an increased risk of adverse outcomes among inpatients with AECOPD, with or without CVDs, which may serve as a convenient predictor of poor prognosis in these patients.
CLINICAL TRIAL REGISTRATION
Chinese Clinical Trail Registry, No. ChiCTR2100044625.
Humans
;
Blood Pressure
;
Pulmonary Disease, Chronic Obstructive/therapy*
;
Cohort Studies
;
Respiration, Artificial
;
Inpatients
;
Hospital Mortality
9.Death-Related Factors in Patients With Acute Exacerbation of Chronic Obstructive Pulmonary Disease Treated by Sequential Mechanical Ventilation.
Zhao-Yun XIE ; Bo WEI ; You-Cai WANG
Acta Academiae Medicinae Sinicae 2023;45(2):221-226
Objective To analyze the death-related factors of elderly patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD) treated by sequential mechanical ventilation,so as to provide evidence for clinical practice. Methods The clinical data of 1204 elderly patients (≥60 years old) with AECOPD treated by sequential mechanical ventilation from June 2015 to June 2021 were retrospectively analyzed.The probability and influencing factors of death were analyzed. Results Among the 1204 elderly patients with AECOPD treated by sequential mechanical ventilation,167 (13.87%) died.Multivariate analysis showed that plasma procalcitonin ≥0.5 μg/L (OR=2.762, 95%CI=1.920-3.972, P<0.001),daily invasive ventilation time ≥12 h (OR=2.202, 95%CI=1.487-3.262,P<0.001),multi-drug resistant bacterial infection (OR=1.790,95%CI=1.237-2.591,P=0.002),oxygenation index<39.90 kPa (OR=2.447,95%CI=1.625-3.685,P<0.001),glycosylated hemoglobin >6% (OR=2.288,95%CI=1.509-3.470,P<0.001),and acute physiology and chronic health evaluation Ⅱ score ≥25 points (OR=2.126,95%CI=1.432-3.156,P<0.001) were independent risk factors for death in patients with AECOPD treated by sequential mechanical ventilation.Oral care>twice/d (OR=0.676,95%CI=0.457-1.000,P=0.048) and sputum excretion>twice/d (OR=0.492, 95%CI=0.311-0.776, P=0.002) were independent protective factors for death in elderly patients with AECOPD treated by sequential mechanical ventilation. Conclusions The outcomes of sequential mechanical ventilation in the treatment of elderly patients with AECOPD are affected by a variety of factors.To reduce the mortality,we put forward the following measures:attaching great importance to severe patients,restoring oxygenation function,shortening unnecessary invasive ventilation time,controlling blood glucose,preventing multidrug resistant bacterial infection,oral care twice a day,and sputum excretion twice a day.
Humans
;
Aged
;
Middle Aged
;
Respiration, Artificial/methods*
;
Retrospective Studies
;
Pulmonary Disease, Chronic Obstructive/therapy*
;
Sputum
10.Modeling the noninvasive bi-level positive airway pressure ventilation therapy system and simulated application.
Yueyang YUAN ; Li ZHOU ; Haoxuan HUANG ; Wei LIU ; Xingshuo HU ; Lixin XIE
Journal of Biomedical Engineering 2023;40(2):343-349
Without artificial airway though oral, nasal or airway incision, the bi-level positive airway pressure (Bi-PAP) has been widely employed for respiratory patients. In an effort to investigate the therapeutic effects and measures for the respiratory patients under the noninvasive Bi-PAP ventilation, a therapy system model was designed for virtual ventilation experiments. In this system model, it includes a sub-model of noninvasive Bi-PAP respirator, a sub-model of respiratory patient, and a sub-model of the breath circuit and mask. And based on the Matlab Simulink, a simulation platform for the noninvasive Bi-PAP therapy system was developed to conduct the virtual experiments in simulated respiratory patient with no spontaneous breathing (NSB), chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). The simulated outputs such as the respiratory flows, pressures, volumes, etc, were collected and compared to the outputs which were obtained in the physical experiments with the active servo lung. By statistically analyzed with SPSS, the results demonstrated that there was no significant difference ( P > 0.1) and was in high similarity ( R > 0.7) between the data collected in simulations and physical experiments. The therapy system model of noninvasive Bi-PAP is probably applied for simulating the practical clinical experiment, and maybe conveniently applied to study the technology of noninvasive Bi-PAP for clinicians.
Humans
;
Respiration, Artificial/methods*
;
Positive-Pressure Respiration/methods*
;
Respiration
;
Ventilators, Mechanical
;
Lung


Result Analysis
Print
Save
E-mail