1.Protective effect of graphene heating film far-infrared hyperthermia against frostbite in mice.
Jinshui ZHANG ; Shuo LI ; Dongdong WEI ; Xin CHENG ; Yun DENG ; Youzhi ZHANG
Journal of Southern Medical University 2025;45(3):522-530
OBJECTIVES:
To investigate the protective effects of graphene heating film far-infrared (FIR) hyperthermia therapy against frostbite in mice and its impacts on microcirculation and coagulation function.
METHODS:
Seventy-six C57BL/6J mice were randomized into control, model, graphene-FIR, and carbon fiber-FIR groups. After 7-day FIR intervention (4 h/day), the mice were subjected to acute (4 ℃, 4 h) and intermittent (4 ℃, 4 h/day for 3 days) cold exposure and the changes in rectal temperature were monitored. In liquid nitrogen frostbite experiment, 24 ICR mice were divided into model, graphene-FIR, and carbon fiber-FIR groups, and after a 7-day FIR pretreatment (4 h/day), the liquid nitrogen frostbite models were established and apparent scores of the wounds were assessed on days 3 and 6 after modeling. In carrageenan-induced thrombosis experiment, 40 ICR mice were allocated to control, model, graphene-FIR, carbon fiber-FIR, and prazosin groups to test the effect of a 7-day FIR intervention on thrombosis induced by intraperitoneal carrageenan injection (2.5 mg/kg) by measuring thrombus length, blood perfusion, and serum biomarkers (6-keto-PGF1α, TXB2, t-PA, IL-6, IL-1β, TNF‑α) 24 h after the injection.
RESULTS:
The mice in graphene-FIR group showed significantly elevated rectal temperature in cold exposure tests. In mice with liquid nitrogen-induced frostbite, graphene-FIR treatment significantly reduced the wound scores and reduced frostbite area, producing better effects than carbon fiber. In mice with carrageenan-induced thrombosis, graphene-FIR treatment significantly decreased tail thrombosis length and thrombosis area, increased blood perfusion, lowered serum levels of TXB2, TNF-α and IL-6, and increased the levels of 6-keto-PGF1α and t-PA.
CONCLUSIONS
Graphene heating film FIR therapy can alleviate frostbite injury in mice by improving microcirculation, suppressing thrombosis and inflammatory responses, and reducing coagulation dysfunction.
Animals
;
Frostbite/therapy*
;
Graphite
;
Mice, Inbred C57BL
;
Mice
;
Infrared Rays
;
Mice, Inbred ICR
;
Hyperthermia, Induced/methods*
;
Male
;
Microcirculation
2.Suprachiasmatic Nucleus Vasoactive Intestinal Peptide Neurons Mediate Light-induced Transient Forgetting.
Xiaoya SU ; Yikai TANG ; Yi ZHONG ; Yunlong LIU
Neuroscience Bulletin 2025;41(11):2025-2035
Our research reveals the critical role of the suprachiasmatic nucleus (SCN) vasoactive intestinal peptide (VIP) neurons in mediating light-induced transient forgetting. Acute exposure to bright light selectively impairs trace fear memory by activating VIP neurons in the SCN, as demonstrated by increased c-Fos expression and Ca2+ recording. This effect can be replicated and reversed through optogenetic and chemogenetic manipulations of SCN VIP neurons. Furthermore, we identify the SCN → PVT (paraventricular nucleus of the thalamus) VIP neuronal circuitry as essential in this process. These findings establish a novel role for SCN VIP neurons in modulating memory accessibility in response to environmental light cues, extending their known function beyond circadian regulation and revealing a mechanism for transient forgetting.
Animals
;
Vasoactive Intestinal Peptide/metabolism*
;
Male
;
Mice
;
Neurons/metabolism*
;
Suprachiasmatic Nucleus/physiology*
;
Light
;
Mice, Inbred C57BL
;
Memory/physiology*
;
Fear/physiology*
;
Suprachiasmatic Nucleus Neurons/metabolism*
;
Optogenetics
;
Proto-Oncogene Proteins c-fos/metabolism*
3.Single-cell and spatial transcriptomics reveals an anti-tumor neutrophil subgroup in microwave thermochemotherapy-treated lip cancer.
Bingjun CHEN ; Huayang FAN ; Xin PANG ; Zeliang SHEN ; Rui GAO ; Haofan WANG ; Zhenwei YU ; Tianjiao LI ; Mao LI ; Yaling TANG ; Xinhua LIANG
International Journal of Oral Science 2025;17(1):40-40
Microwave thermochemotherapy (MTC) has been applied to treat lip squamous cell carcinoma (LSCC), but a deeper understanding of its therapeutic mechanisms and molecular biology is needed. To address this, we used single-cell transcriptomics (scRNA-seq) and spatial transcriptomics (ST) to highlight the pivotal role of tumor-associated neutrophils (TANs) among tumor-infiltrating immune cells and their therapeutic response to MTC. MNDA+ TANs with anti-tumor activity (N1-phenotype) are found to be abundantly infiltrated by MTC with benefit of increased blood perfusion, and these TANs are characterized by enhanced cytotoxicity, ameliorated hypoxia, and upregulated IL1B, activating T&NK cells and fibroblasts via IL1B-IL1R. In this highly anti-tumor immunogenic and hypoxia-reversed microenvironment under MTC, fibroblasts accumulated in the tumor front (TF) can recruit N1-TANs via CXCL2-CXCR2 and clear N2-TANs (pro-tumor phenotype) via CXCL12-CXCR4, which results in the aggregation of N1-TANs and extracellular matrix (ECM) deposition. In addition, we construct an N1-TANs marker, MX2, which positively correlates with better prognosis in LSCC patients, and employ deep learning techniques to predict expression of MX2 from hematoxylin-eosin (H&E)-stained images so as to conveniently guide decision making in clinical practice. Collectively, our findings demonstrate that the N1-TANs/fibroblasts defense wall formed in response to MTC effectively combat LSCC.
Humans
;
Neutrophils/metabolism*
;
Single-Cell Analysis
;
Lip Neoplasms/genetics*
;
Hyperthermia, Induced/methods*
;
Microwaves/therapeutic use*
;
Transcriptome
;
Carcinoma, Squamous Cell/immunology*
;
Tumor Microenvironment
4.Oroxylin A inhibits UVB-induced non-melanoma skin cancer by regulating XPA degradation.
Renjie DOU ; Jiarui SUN ; Hang YANG ; Yufen ZHENG ; Kang YUAN ; Lei QIANG ; Run MA ; Yunyao LIU
Chinese Journal of Natural Medicines (English Ed.) 2025;23(6):742-753
Oroxylin A (OA), a natural compound extracted from Scutellaria baicalensis, demonstrates preventive potential against ultraviolet B (UVB)-induced non-melanoma skin cancer (NMSC), the most prevalent cancer worldwide with increasing incidence. Utilizing SKH-1 hairless mice exposed to UVB, this study showed that OA delayed NMSC onset and alleviated acute skin damage. Mechanistic investigations revealed its dual action: inhibiting inflammation and enhancing nucleotide excision repair (NER) by stabilizing XPA, a crucial deoxyribonucleic acid (DNA) repair protein. This stabilization occurred through OA's interaction with glucose-regulated protein 94 (GRP94), which disrupted murine double minute 2 (MDM2)-mediated XPA ubiquitination and proteasomal degradation. By maintaining XPA levels, OA expedited photoproduct clearance and diminished genomic instability, ultimately impeding NMSC development. These findings suggest OA as a promising chemopreventive agent targeting the GRP94/MDM2-XPA axis to counteract UVB-induced carcinogenesis.
Animals
;
Ultraviolet Rays/adverse effects*
;
Skin Neoplasms/prevention & control*
;
Flavonoids/pharmacology*
;
Mice
;
Xeroderma Pigmentosum Group A Protein/genetics*
;
Humans
;
Proto-Oncogene Proteins c-mdm2/genetics*
;
DNA Repair/drug effects*
;
Scutellaria baicalensis/chemistry*
;
Mice, Hairless
;
Skin/radiation effects*
5.Clinical study on low-energy semiconductor laser treatment in the promotion of wound healing after maxillofacial fracture surgery.
Maojing XIONG ; Lu YANG ; Liyuan MA ; Lei LIU ; Bo YANG
West China Journal of Stomatology 2025;43(1):68-75
OBJECTIVES:
This study aims to evaluate the clinical effect of low-energy semiconductor laser treatment on the promotion of wound healing after maxillofacial fracture surgery.
METHODS:
A prospective randomized controlled study was conducted. Patients with maxillofacial fractures who were hospitalized in the Department of Trauma and Plastic Surgery, West China Hospital of Stomatology, Sichuan University, from August 2021 to June 2023 were selected as the study subjects and randomly divided into experimental and control groups. The experimental group was treated with a low-energy semiconductor laser once a day for six consecutive days after daily routine dressing change on the first day after surgery. The control group only underwent routine dressing change treatment and did not receive low-energy semiconductor laser treatment. Wound healing times, wound healing conditions, modified Stony Brook scar evaluation scale (mSBSES) scores, pain indices, and wound infection rates were compared between the two groups.
RESULTS:
A total of 211 patients were included in this study. A total of 104 and 107 cases comprised the experimental and control groups, respectively. A total of 128 males and 83 females were included. After low-energy semiconductor laser treatment, the facial skin wound healing time of the experimental group was found to be significantly shorter than that of the control group (P<0.05). Moreover, the wound grade A healing rate of the experimental group was higher than that of the control group on the seventh day after surgery (P<0.05). Among postoperative facial skin wound evaluation indices, the mSBSES scores of the experimental group at all observation points were higher than those of the control group (P<0.05), and the scores of the experimental group were higher than those of the control group in terms of wound width reduction, height reduction, color lightening, and incision line loss (P<0.05). In postoperative wound pain evaluation, the pain index of the experimental group after low-energy semiconductor laser treatment was significantly lower than that of the control group (P<0.05). No significant difference in wound infection rates was found between the two groups (P>0.05).
CONCLUSIONS
For facial skin wounds in maxillofacial fracture surgery, low-energy semiconductor laser treatment can effectively promote wound healing, improve wound healing quality, fade scars, and relieve wound pain.
Humans
;
Wound Healing/radiation effects*
;
Male
;
Female
;
Lasers, Semiconductor/therapeutic use*
;
Prospective Studies
;
Adult
;
Middle Aged
;
Low-Level Light Therapy
;
Maxillofacial Injuries/surgery*
;
Young Adult
6.Progress in microbial photoelectrotrophic denitrification.
Zhenjun TIAN ; Lieyu ZHANG ; Yangwei BAI ; Yimei WEI ; Yang BAI ; Zelin SHAN ; Yongkun YU
Chinese Journal of Biotechnology 2025;41(6):2324-2333
Microbial denitrification is a major pathway for nitrogen removal from water bodies. However, denitrification is often difficult to continue when there is a lack of microbially available organic matter in the water body to serve as electron donors. In recent years, studies have shown that some denitrifying bacteria can directly utilize photoelectrons generated by sunlight-excited semiconductor minerals or natural organic matter for denitrification without the need for bioavailable organic matter as electron donors. This process is defined as microbial photoelectrotrophic denitrification. The discovery of microbial photoelectrotrophic denitrification phenomenon reshapes the previous knowledge about the chemoheterotrophic mode of denitrifying bacteria and broadens the pathway of nitrogen removal by the new photoelectrotrophic metabolism, which is of great significance to our understanding and exploration of sunlight-driven nitrogen cycling process. In this paper, we comprehensively sort out the existing research reports in the field of microbial photoelectrotrophic denitrification, systematically summarize the principle and the current research progress of microbial photoelectrotrophic denitrification, deeply analyze the problems and challenges faced by this technology, and make an outlook on the future research directions and application prospects of this technology, providing a reference for the further research and application of this technology.
Denitrification/physiology*
;
Nitrogen/isolation & purification*
;
Bacteria/metabolism*
;
Sunlight
;
Phototrophic Processes
7.Research progress in the fungal bioluminescence pathway.
Lei LÜ ; Ke CHENG ; Zhitao XU ; Shijie AN ; Dang XU ; Hao DU
Chinese Journal of Biotechnology 2025;41(7):2545-2558
The fungal bioluminescence pathway (FBP) catalyzes the oxidation of endogenous caffeic acid to produce green bioluminescence through an enzymatic cascade. Genetic engineering of FBP into plants creates autoluminescent specimens that circumvent the substrate limitations of conventional reporter systems. These transgenic plants serve dual functions as aesthetic displays and versatile biosensing platforms, enabling applications in real-time gene expression monitoring, continuous environmental surveillance, and non-invasive bioimaging, offering novel opportunities for horticultural production, environmental conservation, and bioengineering applications. This review synthesizes current advances in plant FBP engineering and explores how machine learning approaches can optimize autoluminescent phenotypes, thereby accelerating innovation in agricultural biotechnology, environmental sensing, and synthetic biology applications.
Fungi/genetics*
;
Plants, Genetically Modified/metabolism*
;
Genetic Engineering
;
Biosensing Techniques
;
Luminescent Measurements
;
Caffeic Acids/metabolism*
;
Luminescence
8.Image repeat analysis in conventional radiography in mobile clinics: A retrospective observational study.
Mark M. Alpio ; Grace Meroflor A. Lantajo ; Joseph Dave M. Pregoner
Acta Medica Philippina 2025;59(Early Access 2025):1-5
BACKGROUND
Mobile clinics offer crucial healthcare services, including X-ray examinations, to underserved communities. Minimizing image repeats in this setting is vital due to radiation exposure, patient inconvenience, and cost implications.
OBJECTIVESThis study investigated the prevalence and causes of image repeat in conventional radiography performed within mobile clinics in the Philippines.
METHODSA retrospective review analyzed data from five mobile clinics located in two highly urbanized cities in the Philippines from July to December 2023). Radiology staff assessed image quality, with suboptimal images requiring retakes. Reasons for rejection were categorized.
RESULTSOut of 871 radiographs taken, 118 (13.55%) were repeated. Vertebrae and pelvic girdle images had the highest repeat rates (33.33%). Positioning errors were the most common cause (44.07%), followed by underexposure and overexposure.
CONCLUSIONThis study identified a concerning repeat rate (13.55%) for mobile X-rays, primarily due to improper patient positioning, particularly for specific body parts. Targeted training programs and stricter protocols for mobile clinic staff are needed. Radiography education should also emphasize these skills, potentially through collaboration with mobile clinic operators to ensure graduates are prepared for the unique challenges of this environment.
Mobile Health Units ; Patient Positioning ; Radiography ; X-rays ; X-ray Film
9.The effect of cycled light exposure on clinical outcomes of preterm infants admitted in neonatal intensive care units
Roffell D. Felisilda ; Katrina Mae G. Lee ; Christine Corina Grace L. Basilla
The PCMC Journal 2025;21(1):27-41
BACKGROUND:
Hospitalization in neonatal intensive care units (NICU) exposes preterm infants to adverse stimuli, including continuous 24-hour lighting. There is currently no standardized NICU layout advised for the best development of preterm neonates. This meta-analysis aimed to assess the impact of cycled light (CL) exposure on clinical outcomes in premature infants admitted to NICU as synthesized in previous studies.
MATERIALS AND METHODS:
This meta-analysis protocol was developed following the preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) statement. A search was performed in PubMed/MEDLINE, EMBASE, Scopus, and Cochrane databases using the MeSH/key words: ―light exposure‖ AND pre-term AND cycled AND (RCT OR trials OR ―randomized controlled trial). The pooled Mean Difference with corresponding 95% CI was computed for weight gain, duration until start of enteral feeding, and duration of ICU stay using the Mantel–Haenszel random-effect model.
RESULTS:
Nine studies were included. The pooled mean difference showed that among preterm infants who had cycled light exposure, average daily weight gain (MD=6.24 grams, 95%CI=1.36 to 11.13, p=0.01) was significantly higher than those with continuous light exposure. The average time to start enteral feeding (MD=-3.84 days, 95%CI=-7.56 to -0.13, p=0.04) and average ICU stay (MD=-8.43 days, 95%CI=-12.54 to -4.31, p<0.0001) among neonates who had cycled light exposure were significantly shorter.
CONCLUSION
Benefits were seen in preterm infants when exposed to cycled light as opposed to continuous light. CL exposed infants showed a daily weight gain that was 6.24 grams higher, on average, and began enteral feeding nearly 4 days sooner. It led to a decrease in the duration of ICU stay by around 8 to 9 days on average. Further trials to determine the impact of cycled light exposure on morbidity and mortality among preterm neonates is recommended.
Human
;
Male,Female
;
Systematic review
;
Meta-analysis
;
Infant, Premature
;
Intensive care units, Neonatal
;
Intensive care, Neonatal
;
Light
;
Lighting
;
Critical care
10.Image repeat analysis in conventional radiography in mobile clinics: A retrospective observational study.
Mark M. ALIPIO ; Grace Meroflor A. LANTAJO ; Joseph Dave M. PREGONER
Acta Medica Philippina 2025;59(18):56-60
BACKGROUND
Mobile clinics offer crucial healthcare services, including X-ray examinations, to underserved communities. Minimizing image repeats in this setting is vital due to radiation exposure, patient inconvenience, and cost implications.
OBJECTIVESThis study investigated the prevalence and causes of image repeat in conventional radiography performed within mobile clinics in the Philippines.
METHODSA retrospective review analyzed data from five mobile clinics located in two highly urbanized cities in the Philippines from July to December 2023). Radiology staff assessed image quality, with suboptimal images requiring retakes. Reasons for rejection were categorized.
RESULTSOut of 871 radiographs taken, 118 (13.55%) were repeated. Vertebrae and pelvic girdle images had the highest repeat rates (33.33%). Positioning errors were the most common cause (44.07%), followed by underexposure and overexposure.
CONCLUSIONThis study identified a concerning repeat rate (13.55%) for mobile X-rays, primarily due to improper patient positioning, particularly for specific body parts. Targeted training programs and stricter protocols for mobile clinic staff are needed. Radiography education should also emphasize these skills, potentially through collaboration with mobile clinic operators to ensure graduates are prepared for the unique challenges of this environment.
Mobile Health Units ; Patient Positioning ; Radiography ; X-rays ; X-ray Film


Result Analysis
Print
Save
E-mail