2.Advances in electrochemically active biofilm of Shewanella oneidensis MR-1.
Chinese Journal of Biotechnology 2023;39(3):881-897
Facing the increasingly severe energy shortage and environmental pollution, electrocatalytic processes using electroactive microorganisms provide a new alternative for achieving environmental-friendly production. Because of its unique respiratory mode and electron transfer ability, Shewanella oneidensis MR-1 has been widely used in the fields of microbial fuel cell, bioelectrosynthesis of value-added chemicals, metal waste treatment and environmental remediation system. The electrochemically active biofilm of S. oneidensis MR-1 is an excellent carrier for transferring the electrons of the electroactive microorganisms. The formation of electrochemically active biofilm is a dynamic and complex process, which is affected by many factors, such as electrode materials, culture conditions, strains and their metabolism. The electrochemically active biofilm plays a very important role in enhancing bacterial environmental stress resistance, improving nutrient uptake and electron transfer efficiency. This paper reviewed the formation process, influencing factors and applications of S. oneidensis MR-1 biofilm in bio-energy, bioremediation and biosensing, with the aim to facilitate and expand its further application.
Bioelectric Energy Sources/microbiology*
;
Biofilms
;
Electrodes
;
Electron Transport
;
Shewanella/metabolism*
5.Chinese emergency expert consensus on bedside temporary cardiac pacing (2023).
EMERGENCY MEDICINE BRANCH OF CHINESE MEDICAL ASSOCIATION ; BEDSIDE TEMPORARY CARDIAC PACING CONSENSUS EMERGENCY EXPERT GROUP
Chinese Critical Care Medicine 2023;35(7):678-683
Temporary cardiac pacing is an essential technique in the diagnosis and treatment of arrhythmias. Due to its urgency, complexity, and uncertainty, it is necessary to develop an evidence-based emergency operation norms. Currently, there is no specific consensus guidelines at home or abroad. The Emergency Branch of Chinese Medical Association organized relevant experts to draft the Chinese emergency expert consensus on bedside temporary cardiac pacing (2023) to guide the operation and application of bedside cardiac pacing. The formulation of the consensus adopts the consensus meeting method and the evidentiary basis and recommendation grading of the Oxford Center for Evidence-based Medicine in the United States. A total of 13 recommendations were extracted from the discussion on the methods of bedside temporary cardiac pacing, the puncture site of transvenous temporary cardiac pacing, the selection of leads, the placement and placement of leads, pacemaker parameter settings, indications, complications and postoperative management. The recommended consensus includes the choice between transcutaneous and transvenous pacing, preferred venous access for temporary transvenous pacing, the target and best guidance method for implantation of bedside pacing electrodes, recommended default pacemaker settings, recommended indications for sinoatrial node dysfunction, atrioventricular block, acute myocardial infarction, cardiac arrest, ventricular and supraventricular arrhythmias. They also recommended ultrasound guidance and a shortened temporary pacing support time to reduce complications of temporary transvenous cardiac pacing, recommended bedrest, and anticoagulation after temporary transvenous pacing. Bedside temporary cardiac pacing is generally safe and effective. Accurate assessment, correct selection of the pacing mode, and timely performance of bedside temporary cardiac pacing can further improve the survival rate and prognosis of related emergency patients.
Humans
;
Cardiac Pacing, Artificial/methods*
;
Pacemaker, Artificial
;
Arrhythmias, Cardiac/therapy*
;
Myocardial Infarction/therapy*
;
Electrodes
6.Cochlear electrode array misplacement into the superior semicircular canal: a case report and literature review.
Chen SUN ; Zhenghua HUANG ; Yingxue MA ; Ye GU ; Qi LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2023;37(4):310-312
Electrode array misplacement is a rare complication of cochlear implant. This article reports an 11-year-old boy who was mistakenly implanted the cochlear electrode array into the superior semicircular canal during the initial cochlear implant. After the diagnosis was confirmed, he underwent a second cochlear implant and the electrode array were successfully implanted into the cochlea. This article conducted a systematic review of the literature on electrode array misplacement, and the causes of electrode array misplacement were analyzed from different implantation position.
Male
;
Humans
;
Child
;
Electrodes, Implanted
;
Reoperation
;
Cochlea
;
Cochlear Implantation
;
Cochlear Implants/adverse effects*
;
Semicircular Canals/surgery*
7.Application of intraoperative CT-assisted positioning in difficult cases of cochlear implantation.
Fan ZHANG ; Xing LU ; Wenjing ZHANG ; Lu LI ; Han XUAN ; Zhaobing QIN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2023;37(5):329-333
Objective:To report the experience of using CT-guided cochlear implant surgery in difficult cases such as severe inner ear deformities and anatomical abnormalities, and to discuss the application value of intraoperative CT-assisted localization in difficult cases of cochlear implant surgery. Methods:Retrospectively analyzed the clinical data of 23 cases of difficult cochlear implant surgery cases completed by our team with the assistance of intraoperative CT, and collected their medical data, including preoperative imaging manifestations, surgical conditions, and intraoperative imaging images for evaluation. Results:During the study period, 23 difficult cases(27 ears) underwent cochlear implantation under the guidance of intraoperative CT, and 4 cases were bilaterally implanted. Including 6 cases of incomplete segmentation type Ⅰ(IP-Ⅰ), 1 case of incomplete segmentation type Ⅱ(IP-Ⅱ), 10 cases of incomplete segmentation type Ⅲ(IP-Ⅲ), 3 cases of common cavity deformity(CC) and 3 cases of cochlear ossification after meningitis. Facial nerve anatomy was abnormal in 9 cases, cerebrospinal fluid "blowout" was serious in 14 cases, electrode position was abnormal in 3 cases requiring intraoperative adjustment of electrode position, anatomical difficulties required intraoperative CT to assist in finding anatomical landmarks in 2 cases, and electrodes were not fully implanted in 3 cases. Conclusion:When faced with difficult cases with challenging and complex temporal bone anatomy, intraoperative CT can accurately evaluate the electrode position and provide intraoperative anatomical details, allowing immediate adjustment of the electrode position if necessary, providing safety guarantee for difficult cases of cochlear implant surgery and ensure accurate implantation of electrodes.
Humans
;
Cochlear Implantation/methods*
;
Retrospective Studies
;
Tomography, X-Ray Computed/methods*
;
Cochlea
;
Cochlear Implants
8.Analysis of rehabilitation effects of cochlear implantation in elderly patients with prelingual deafness.
Haijuan WU ; Tongli LI ; Guodong LI ; Jingjing HUO
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2023;37(6):478-482
Objective:The auditory and speech rehabilitation effects were assessed by the Categories of Auditory Performance(CAP) and the speech intelligibility rating scale(SIR) after cochlear implantation(CI) in prelingually elderly patients by telephone follow-up or face-to-face conversation. Methods:The clinical data of the prelingually deaf patients who underwent unilateral CI in the Department of Otorhinolaryngology and Head and Neck Surgery, Shanxi People's Hospital, from December 2016 to December 2021 were collected. Thirty-eight patients were divided into Group A(SIR 1, 17 cases), Group B(SIR 2, 10 cases) and Group C(SIR 3, 11 cases) according to the preoperative SIR Score. Nineteen patients with post-lingual hearing impairment were selected as the control group(Group D, 19 cases). The effects of hearing and speech rehabilitation were evaluated using CAP and SIR Scores before surgery, 6 months after startup, and 1 year after startup. Results:There were no significant differences in CAP scores among the three groups of patients with prelingually deaf patients at 6 months and 1 year after startup(P>0.05), but there were significant differences between group A and group D at 6 months and 1 year after startup(P<0.05); the SIR Score of group A had statistical difference before surgery and 6 months after startup(P<0.05), group B had statistical difference before surgery and 1 year after startup(P<0.05), and group C and D had no statistical difference before surgery and 6 months and 1 year after startup, respectively(P>0.05). Conclusion:For the prelingually deaf elderly patients, hearing will develop rapidly 6 months after startup, and the effect of postoperative auditory rehabilitation was positively correlated with the preoperative speech ability. In the aspect of speech, the prelingually dear elderly patients who have poor preoperative speech ability could benefit more from CI early after surgery. CI is not contraindicated in prelingually deaf elderly patients, even those with poor preoperative speech function.
Humans
;
Aged
;
Cochlear Implantation/methods*
;
Cochlear Implants
;
Speech Perception
;
Deafness/rehabilitation*
;
Hearing Tests
;
Speech Intelligibility
;
Treatment Outcome
9.Feasibility study of using bridging temporary permanent pacemaker in patients with high-degree atrioventricular block after TAVR.
San Shuai CHANG ; Xin Min LIU ; Zhi Nan LU ; Jing YAO ; Cneng Qian YIN ; Wen Hui WU ; Fei YUAN ; Tai Yang LUO ; Zheng Ming JIANG ; Guang Yuan SONG
Chinese Journal of Cardiology 2023;51(6):648-655
Objective: To determine the feasibility of using temporary permanent pacemaker (TPPM) in patients with high-degree atrioventricular block (AVB) after transcatheter aortic valve replacement (TAVR) as bridging strategy to reduce avoidable permanent pacemaker implantation. Methods: This is a prospective observational study. Consecutive patients undergoing TAVR at Beijing Anzhen Hospital and the First Affiliated Hospital of Zhengzhou University from August 2021 to February 2022 were screened. Patients with high-degree AVB and TPPM were included. Patients were followed up for 4 weeks with pacemaker interrogation at every week. The endpoint was the success rate of TPPM removal and free from permanent pacemaker at 1 month after TPPM. The criteria of removing TPPM was no indication of permanent pacing and no pacing signal in 12 lead electrocardiogram (EGG) and 24 hours dynamic EGG, meanwhile the last pacemaker interrogation indicated that ventricular pacing rate was 0. Routinely follow-up ECG was extended to 6 months after removal of TPPM. Results: Ten patients met the inclusion criteria for TPPM, aged (77.0±11.1) years, wirh 7 females. There were 7 patients with third-degree AVB, 1 patient with second-degree AVB, 2 patients with first degree AVB with PR interval>240 ms and LBBB with QRS duration>150 ms. TPPM were applied on the 10 patients for (35±7) days. Among 8 patients with high-degree AVB, 3 recovered to sinus rhythm, and 3 recovered to sinus rhythm with bundle branch block. The other 2 patients with persistent third-degree AVB received permanent pacemaker implantation. For the 2 patients with first-degree AVB and LBBB, PR interval shortened to within 200 ms. TPPM was successfully removed in 8 patients (8/10) at 1 month without permanent pacemaker implantation, of which 2 patients recovered within 24 hours after TAVR and 6 patients recovered 24 hours later after TAVR. No aggravation of conduction block or permanent pacemaker indication were observed in 8 patients during follow-up at 6 months. No procedure-related adverse events occurred in all patients. Conclusion: TPPM is reliable and safe to provide certain buffer time to distinguish whether a permanent pacemaker is necessary in patients with high-degree conduction block after TAVR.
Female
;
Humans
;
Atrioventricular Block/therapy*
;
Feasibility Studies
;
Transcatheter Aortic Valve Replacement
;
Pacemaker, Artificial
;
Bundle-Branch Block

Result Analysis
Print
Save
E-mail