1.Comparison of effectiveness between two surgical methods for humeral lateral condyle fractures in children.
Hailong MA ; Qingjie WU ; Fang LIU ; Zhongtuo HUA ; Sicheng ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):64-69
OBJECTIVE:
To compare the effectiveness of ultrasound-guided closed reduction with Kirschner wire fixation and open reduction with Kirschner wire fixation in the treatment of humeral lateral condyle fracture (HLCF) in children.
METHODS:
A clinical data of 53 children with HLCF admitted between May 2020 and April 2023 and met selective criteria was retrospectively analyzed. Of these, 25 cases were managed with closed reduction and Kirschner wire fixation under ultrasound guidance (closed group), while 28 cases underwent open reduction and Kirschner wire fixation (open group). There was no significant difference between the two groups in terms of gender, age, cause of injury, fracture side, fracture classification, and time from injury to operation ( P>0.05). The following variables were recorded and compared between the two groups: operation time, intraoperative fluoroscopy frequency, fracture healing time, incidence of complications, and the Flynn elbow function score at last follow-up.
RESULTS:
In the closed group, the fractures were successfully reduced under ultrasound guidance, with no nerve damage reported in either group. The operation time and intraoperative fluoroscopy frequency were significantly less in the closed group than in the open group ( P<0.05). One case of infection (Kirschner wire irritation) was observed in the closed group, while 3 cases in the open group (2 of Kirschner wire irritation and 1 of incision infection). However, the difference in the incidence of infection between the two groups was not significant ( P>0.05). All patients in both groups were followed up 6-18 months (mean, 10.2 months). X-ray examinations confirmed that fractures had healed in both groups, with no significant difference in healing time ( P>0.05). During follow-up, 5 cases of lateral humeral process formation were observed in the closed group, compared to 12 cases in the open group, although this difference was not significant ( P>0.05). At last follow-up, the excellent and good rate of elbow joint function was evaluated as 96.0% (24/25) in the closed group and 92.9% (26/28) in the open group according to the Flynn scoring criteria, with no significant difference between the two groups ( P>0.05). Both groups showed no occurrence of ossifying myositis or elbow internal/external rotation.
CONCLUSION
The effectiveness of ultrasound-guided closed reduction and Kirschner wire fixation in the treatment of HLCF in children is comparable to open reduction and Kirschner wire fixation, but the former can reduce operation time and intraoperative fluoroscopy frequency, and obtain lower the incidence of complications.
Humans
;
Humeral Fractures/diagnostic imaging*
;
Bone Wires
;
Male
;
Female
;
Child
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Child, Preschool
;
Open Fracture Reduction/methods*
;
Fracture Healing
;
Elbow Joint/surgery*
;
Adolescent
;
Closed Fracture Reduction/methods*
;
Fluoroscopy
;
Operative Time
2.Application of elbow skin fold extension line in extreme elbow flexion in ulnar Kirschner wire insertion of extended supracondylar humeral fractures in children.
Xu LIU ; Wei WU ; Yuzhou SHAN ; Guanghui YANG ; Ming CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):70-74
OBJECTIVE:
To discuss the elbow skin fold extension line in Kirschner wire internal fixation of extended supracondylar humeral fractures in children.
METHODS:
The clinical data of 58 children with extended supracondylar fractures of the humerus who met the selection criteria between August 2021 and July 2024 were retrospectively analyzed. In 28 cases, needle placement of medial epicondyle of humerus was performed with the assistance of the elbow skin fold extension line (study group), and 30 cases were assisted by routine touch of the medial epicondyle of the humerus (control group). There was no significant difference in baseline data such as gender, age, side, cause of injury, Gartland type, Kirschner wire configuration, and time from injury to operation between the two groups ( P>0.05). The closed reduction rate, total operation time, time of medial humeral condyle pin placement, fluoroscopy times during medial pin placement, rate of one-time determination of medial entry point, ulnar nerve injury incidence, and fracture healing time were recorded and compared between the two groups. At the same time, the closed reduction rate of patients with the time from injury to operation ≤24 hours and >24 hours was compared. The elbow function was evaluated by Mayo elbow function score.
RESULTS:
The closed reduction rate of the study group was significantly higher than that of the control group ( P<0.05). Among all patients, the closed reduction rate of patients with the time from injury to operation ≤24 hours [73.3% (22/30)] was significantly higher than that of patients >24 hours [42.9% (12/28)] ( χ 2=5.545, P=0.019). The total operation time, medial needle placement time, and fluoroscopy times in the study group were significantly less than those in the control group, and the one-time determination rate of medial needle entry point in the study group was significantly higher than that in the control group ( P<0.05). There were 4 cases of ulnar nerve injury in the control group, and no ulnar nerve injury in the study group, but there was no significant difference in the incidence of ulnar nerve injury between the two groups ( P>0.05). All patients were followed up 6-12 months (mean, 8 months). There was no bone nonunion in both groups, and the fracture healing time of the study group was significantly shorter than that of the control group ( P<0.05). Volkmann ischemic contracture, heterotopic ossification, myositis ossificans, and premature epiphyseal closure were not observed after operation. No complications such as loosening or fracture of Kirschner wire occurred. At last follow-up, the Mayo elbow joint function score was used to evaluate function, and there was no significant difference between the two groups ( P>0.05).
CONCLUSION
In the treatment of extended supracondylar fractures of the humerus in children, the elbow skin fold extension line can help to quickly locate the medial epicondyle of the humerus, quickly insert Kirschner wire, and reduce the operation time and trauma.
Humans
;
Humeral Fractures/surgery*
;
Bone Wires
;
Male
;
Female
;
Fracture Fixation, Internal/instrumentation*
;
Retrospective Studies
;
Child
;
Elbow Joint/physiopathology*
;
Child, Preschool
;
Treatment Outcome
;
Fracture Healing
;
Ulnar Nerve/injuries*
;
Adolescent
;
Range of Motion, Articular
3.Effectiveness of arthroscopic release assisted with medial small incision in treatment of non-traumatic elbow stiffness.
Lijun LÜ ; Yanyan CHANG ; Baojun ZHOU ; Qiuming GAO ; Jieliang HU ; Liyuan CHEN ; Kongxing WEI ; Fujun GAO ; Wentao LI ; Xin YUAN ; Yibin JIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):563-568
OBJECTIVE:
To explore the effectiveness of arthroscopic release of elbow joint assisted by medial small incision ulnar nerve release in the treatment of non-traumatic elbow stiffness.
METHODS:
The clinical data of 15 patients with non-traumatic elbow stiffness treated with arthroscopic release of elbow joint assisted by medial small incision ulnar nerve release between April 2019 and September 2023 were retrospectively analyzed. There were 6 males and 9 females with an average age of 46 years ranging from 34 to 56 years. The causes included rheumatoid arthritis in 3 cases, gouty arthritis in 2 cases, loose bodies in 3 cases, and elbow osteoarthritis in 7 cases. There were 4 cases with ulnar neuritis and 3 cases with synovial osteochondromatosis. The duration of elbow stiffness ranged from 6 to 18 months, with an average of 10 months. The operation time and intraoperative blood loss were recorded. The effectiveness was evaluated by visual analogue scale (VAS) score, range of elbow motion (maximum flexion, maximum extension, and total flexion and extension), Mayo score, and Hospital for Special Surgery (HSS) elbow score.
RESULTS:
The operation time was 60-90 minutes, with an average of 65 minutes, and the intraoperative blood loss was 40-100 mL, with an average of 62 mL. All patients were followed up 13-18 months, with an average of 14 months. There was no complication such as vascular and nerve injury, poor wound healing, collateral ligament injury, elbow joint space narrowing, osteophyte proliferation, or loose body formation around the joint. At last follow-up, the elbow range of motion (maximum flexion, maximum extension, and total flexion and extension), VAS score, and Mayo score significantly improved when compared with those before operation ( P<0.05). The HSS elbow score was 85-95, with an average of 92; 12 cases were excellent, 3 cases were good, and the excellent and good rate was 100%.
CONCLUSION
Arthroscopic release of elbow joint assisted by medial small incision ulnar nerve release is an effective way to treat non-traumatic elbow stiffness, which has the advantages of small trauma, short operation time, and good effectiveness. It can carry out early elbow rehabilitation training and significantly improve elbow function.
Humans
;
Male
;
Female
;
Arthroscopy/methods*
;
Adult
;
Middle Aged
;
Elbow Joint/physiopathology*
;
Retrospective Studies
;
Range of Motion, Articular
;
Treatment Outcome
;
Ulnar Nerve/surgery*
;
Operative Time
4.Biomechanical advantages of personalized Y-shaped plates in treatment of distal humeral intra-articular fractures.
Hao YU ; Jiachen PENG ; Jibin YANG ; Lidan YANG ; Zhi XU ; Chen YANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):574-583
OBJECTIVE:
To compare the biomechanical properties of personalized Y-shaped plates with horizontal plates, vertical plates, and traditional Y-shaped plates in the treatment of distal humeral intra-articular fractures through finite element analysis, and to evaluate their potential for clinical application.
METHODS:
The study selected a 38-year-old male volunteer and obtained a three-dimensional model of the humerus by scanning his upper limbs using a 64-slice spiral CT. Four types of fracture-internal fixation models were constructed using Mimics 19.0, Geomagic Wrap 2017, Creo 6.0, and other software: horizontal plates, vertical plates, traditional Y-shaped plate, and personalized Y-shaped plate. The models were then meshed using Hypermesh 14.0 software, and material properties and boundary conditions were defined in Abaqus 6.14 software. AnyBody 7.3 software was used to simulate elbow flexion and extension movements, calculate muscle strength, joint forces, and load torques, and compare the peak stress and maximum displacement of the four fixation methods at different motion angles (10°, 30°, 50°, 70°, 90°, 110°, 130°, 150°) during elbow flexion and extension.
RESULTS:
Under dynamic loading during elbow flexion and extension, the personalized Y-shaped plate exhibits significant biomechanical advantages. During elbow flexion, the peak internal fixation stress of the personalized Y-shaped plate was (28.8±0.9) MPa, which was significantly lower than that of the horizontal plates, vertical plates, and traditional Y-shaped plate ( P<0.05). During elbow extension, the peak internal fixation stress of the personalized Y-shaped plate was (18.1±1.6) MPa, which was lower than those of the other three models, with significant differences when compared with horizontal plates and vertical plates ( P<0.05). Regarding the peak humeral stress, the personalized Y-shaped plate model showed mean values of (10.9±0.8) and (13.1±1.4) MPa during elbow flexion and extension, respectively, which were significantly lower than those of the other three models ( P<0.05). Displacement analysis showed that the maximum displacement of the humerus with the personalized Y-shaped plate during elbow flexion was (2.03±0.08) mm, slightly higher than that of the horizontal plates, but significantly lower than that of the vertical plates, showing significant differences ( P<0.05). During elbow extension, the maximum displacement of the humerus with the personalized Y-shaped plate was (1.93±0.13) mm, which was lower than that of the other three models, with significant differences when compared with vertical plates and traditional Y-shaped plates ( P<0.05). Stress contour analysis showed that the stress of the personalized Y-shaped plate was primarily concentrated at the bifurcation of the Y-shaped structure. Displacement contour analysis showed that the personalized Y-shaped plate effectively controlled the displacement of the distal humerus during both flexion and extension, demonstrating excellent stability.
CONCLUSION
The personalized Y-shaped plate demonstrates excellent biomechanical performance in the treatment of distal humeral intra-articular fractures, with lower stress and displacement, providing more stable fixation effects.
Humans
;
Male
;
Adult
;
Healthy Volunteers
;
Finite Element Analysis
;
Tomography, Spiral Computed
;
Models, Anatomic
;
Biomechanical Phenomena
;
Humeral Fractures, Distal/surgery*
;
Fracture Fixation, Internal/instrumentation*
;
Bone Plates
;
Computer Simulation
;
Precision Medicine/methods*
;
Elbow Joint/surgery*
;
Elbow/surgery*
;
Humerus/surgery*
;
Torque
;
Stress, Mechanical
;
Intra-Articular Fractures/surgery*
;
Prosthesis Design/methods*
;
Imaging, Three-Dimensional
;
Range of Motion, Articular
5.Effectiveness comparison of medial-lateral approach and posteromedian approach in release of elbow stiffness after distal humeral fractures surgery.
Lingzhe XUAN ; Hongru MA ; Fengfeng LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1395-1401
OBJECTIVE:
To investigate the difference of effectiveness between medial-lateral approach and posteromedian approach in the release of elbow stiffness after distal humeral fracture surgery.
METHODS:
A retrospective analysis was conducted on the clinical data of 41 patients with elbow stiffness following medial and lateral plate fixation for distal humeral fractures, admitted between January 2021 and June 2023 and meeting selection criteria. Patients were divided into the medial-lateral approach release group (study group, 20 cases) and the posteromedian approach release group (control group, 21 cases) based on surgical approach. Baseline data including age, gender, affected side, body mass index, disease duration, and preoperative extension angle, flexion angle, range of motion, visual analogue scale (VAS) pain score, Mayo elbow performance score, ulnar nerve symptoms, and heterotopic ossification showed no significant difference between groups ( P>0.05). The operation time, intraoperative blood loss, and complication incidence were recorded and compared between groups. Clinical effectiveness was evaluated using pre- and postoperative Mayo score, VAS score, elbow extension/flexion angles, and range of motion on the affected side. Statistical analysis focused on changes in these indicators relative to preoperative values.
RESULTS:
There was no significant difference in operation time and intraoperative blood loss between the two groups ( P>0.05). Patients in both groups were followed up 15-36 months, with a mean of 23.8 months; there was no significant difference in the follow-up time between the two groups ( t=-1.542, P=0.131). In the control group, 1 patient had obvious subcutaneous hematoma and 5 patients had poor wound healing within 2 months after operation, all of which were cured by symptomatic treatment, while no related complications occurred in the study group, there was a significant difference in poor wound healing incidence between the two groups ( P<0.05). At last follow-up, 2 patients in the study group and 3 patients in the control group had mild symptoms of ulnar nerve numbness, and there was no significant difference in the incidence of ulnar nerve symptoms ( P>0.05). All patients had no recurrence or new onset of heterotopic ossification, no skin necrosis or reoperation due to complications. At last follow-up, elbow extension angle, flexion angle, flexion-extension range of motion, VAS score, and Mayo score significantly improved in both groups when compared with the preoperative ones ( P<0.05). There was no significant difference between the change values in elbow extension angle and VAS score between the two groups ( P>0.05); the change values in flexion angle, range of motion, and Mayo score in the study group were significantly better than those in the control group ( P<0.05).
CONCLUSION
The medial-lateral approach can release the elbow stiffness and concurrently remove the medial, lateral, or posterior lateral plates. The incision minimizes disruption to rehabilitation exercises and reduces complications like inadequate wound healing, ultimately leading to improved treatment outcomes.
Humans
;
Humeral Fractures/surgery*
;
Male
;
Female
;
Retrospective Studies
;
Elbow Joint/physiopathology*
;
Middle Aged
;
Fracture Fixation, Internal/adverse effects*
;
Range of Motion, Articular
;
Adult
;
Bone Plates
;
Postoperative Complications/surgery*
;
Treatment Outcome
;
Aged
;
Humeral Fractures, Distal
6.Application of bridge combined fixation system in pediatric Bado type Ⅰ chronic Monteggia fractures.
De PAN ; Xiaoqing HE ; Ying XIONG ; Bolin YUE ; Xi YANG ; Yongqing XU ; Yongyue SU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1516-1520
OBJECTIVE:
To investigate effectiveness of the bridge combined fixation system (BCFS) for Bado typeⅠchronic Monteggia fractures (CMF) in children.
METHODS:
A clinical data of 8 children with Bado type ⅠCMF, who were treated with the BCFS between November 2023 and February 2025, was retrospectively analyzed. There were 6 boys and 2 girls, with a mean age of 7.0 years (range, 4-12 years). The time from injury to operation ranged from 29 to 370 days (median, 68.5 days). Preoperative elbow range of motion was (111.3±17.9)° in flexion, (13.1±13.9)° in extension, (71.9±14.6)° in pronation, and (75.6±13.5)° in supination. Fracture healing time and postoperative complications were observed, and clinical outcomes were evaluated using the Mayo elbow performance score.
RESULTS:
All incisions healed by primary intention without infection, non-healing of the incision, or iatrogenic nerve injury. All children were followed up 4-18 months (mean, 10.3 months). At last follow-up, the elbow range of motion significantly improved to (142.5±2.7)° in flexion, (2.5±2.7)° in extension, (87.5±2.7)° in pronation, and (88.8±2.3)° in supination ( P<0.05). According to the postoperative Mayo elbow performance score, all cases were rated as excellent. Radiographic review showed no radial head dislocation, nonunion at the ulnar osteotomy site, or elbow stiffness, and no breakage of the BCFS or screw loosening. The fracture healing time ranged from 3 to 6 months, with a median of 4 months.
CONCLUSION
The BCFS was confirmed to be effective in the treatment of pediatric Bado type Ⅰ CMF, with good restoration of elbow function and the advantage of avoiding secondary implant removal surgery.
Humans
;
Child
;
Monteggia's Fracture/surgery*
;
Male
;
Female
;
Child, Preschool
;
Range of Motion, Articular
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Elbow Joint/physiopathology*
;
Bone Plates
;
Treatment Outcome
;
Fracture Healing
;
Bone Screws
;
Elbow Injuries
7.Olecranon osteotomy approach for Dubberley type Ⅲ coronal fractures of the distal humerus.
Kai LIU ; Jan-Wei HU ; Yun-Zhou CHEN ; Ru-Guo SHANG ; Yong-Xin YU
China Journal of Orthopaedics and Traumatology 2023;36(2):156-160
OBJECTIVE:
To retrospectively analyze the clinical efficacy of olecranon osteotomy approach in the treatment of Dubberley type Ⅲ coronal fractures of the distal humerus and summarize the treatment experience.
METHODS:
From January 2016 to June 2020, 17 patients (5 males and 12 females) with Dubberley type Ⅲ coronal fractures of the distal humerus were treated by olecranon osteotomy approach. The age ranged from 37 to78 years old with an average of (58.5±12.9) years old. According to Dubberley classification, there were 5 cases of type Ⅲ A and 12 cases of type Ⅲ B. The curative effect was evaluated using the Borberg-Morrey elbow function score. The flexion, extension and rotation range of motion of the elbow joint, complications and postoperative imaging evaluation were recorded.
RESULTS:
All the 17 patients got bony union. The follow-up time ranged from 12 to 33 months with an average of (15.6±5.6) months. There was 1 case of ischemic necrosis of capitulum humeri, 2 cases of traumatic arthritis and 1 case of heterotopic ossification, 1 case of malunion of fracture. The range of motion was (114.80±19.50) °. The Broberg-Morrey score was 85.3±8.2, excellent in 5 cases, good in 9 cases, fair in 3 cases and poor in 0 case.
CONCLUSION
Through olecranon osteotomy approach, the articular surface of distal humerus could be fully exposed, and the operation is convenient. Anatomical reduction and rigid fixation of the articular surface of distal humerus are the key factors for the succesful outcome.
Male
;
Female
;
Humans
;
Adult
;
Olecranon Process/surgery*
;
Elbow Joint/surgery*
;
Humeral Fractures/surgery*
;
Retrospective Studies
;
Fracture Fixation, Internal/methods*
;
Humerus/surgery*
;
Treatment Outcome
;
Range of Motion, Articular
9.PACS and Photoshop assisted isosceles triangle osteotomy and Kirschner wire tension buckle fixation in the treatment of cubitus varus in children.
Chuan-Wei ZHANG ; Xing-Po DING ; Deng-Shan CHEN ; Lei WANG
China Journal of Orthopaedics and Traumatology 2023;36(2):181-184
OBJECTIVE:
To investigate the clinical efficacy of picture archiving and communication system (PACS) and Photoshop assisted isosceles triangle osteotomy and Kirschner wire fixation with tension band in the treatment of cubitus varus in children.
METHODS:
The clinic data of 20 children with cubitus varus treated with isosceles triangle osteotomy of distal humerus and Kirschner wire fixation with tension band from October 2014 to October 2019, were retrospectively analyzed. There were 13 males and 7 females, aged from 3.2 to 13.5 years old, the median age was 6.65 years old. PACS system was applied for the osteotomy design preoperatively, simulating and measuring the side length of isosceles triangle osteotomy. Then, Photoshop system was used to simulate the preoperative and postoperative osteotomy graphics, which could guide precise osteotomy during operation.
RESULTS:
All the 20 patients were followed up for 20 to 24 months, with a median of 22.5 months. At the last follow-up, the carrying angle of the affected limb was 5 ° to 13 °, with a median of 8.3 °. The clinical efficacy was evaluated according to the Flynn elbow function score:excellent in 16 cases, good in 2 cases, and fair in 2 cases.
CONCLUSION
The treatment of cubitus varus in children by isosceles triangle osteotomy and Kirschner wire fixation with tension band assisted by PACS and Photoshop system has shown good clinical outcome.
Male
;
Female
;
Humans
;
Child
;
Child, Preschool
;
Adolescent
;
Humeral Fractures/surgery*
;
Bone Wires
;
Retrospective Studies
;
Humerus/surgery*
;
Treatment Outcome
;
Elbow Joint/surgery*
;
Osteotomy
;
Joint Deformities, Acquired/surgery*
;
Range of Motion, Articular
10.Computer-simulated osteotomy based on health-side combined with guide plate technique in treatment of cubitus varus deformity in adolescents.
Jiaqiang WU ; Wenqiang XU ; Chaoyu LIU ; Yongfei FAN ; Xiulin MA ; Qixin LIU ; Jianqiang ZHANG ; Wei WANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1214-1219
OBJECTIVE:
To explore the feasibility and early effectiveness of computer-simulated osteotomy based on the health-side combined with guide plate technique in the treatment of cubitus varus deformity in adolescents.
METHODS:
The clinical data of 23 patients with cubitus varus deformity who met the selection criteria between June 2019 and February 2023 were retrospectively analyzed. There were 17 males and 6 females, ranging in age from 4 to 16 years with an average of 8.5 years. The time from injury to operation was 1-4 years. The angle of distal humerus rotation was defined by humeral head posterior inclination angle using low radiation dose CT to scan the patient's upper extremity data at one time, and the preoperative rotation of the distal humerus on the affected side was (33.82±4.39)°. The CT plain scan data were imported into 9yuan3D digital orthopaedic system (V3.34 software) to reconstruct three-dimensional images of both upper extremities. The simulated operation was performed with the healthy upper extremity as the reference, the best osteotomy scheme was planned, overlapped and compared, and the osteotomy guide plate was prepared. The patients were followed up regularly after operation, and the formation of callus in the osteotomy area was observed by X-ray examination. Before and after operation, the carrying angle of both upper extremities (the angle of cubitus valgus was positive, and the angle of cubitus varus was negative) and anteversion angle were measured on X-ray and CT images. At the same time, the flexion and extension range of motion of elbow joint and the external rotation range of motion of upper extremity were measured, and Mayo score was used to evaluate the function of elbow joint.
RESULTS:
The operation time ranged from 34 to 46 minutes, with an average of 39 minutes. All patients were followed up 5-26 months, with a mean of 14.9 months. All the incisions healed by first intention after the operation; 2 patients had nail path irritation symptoms after Kirschner wire fixation, which improved after dressing change; no complication such as breakage and loosening of internal fixators occurred after regular X-ray review. Continuous callus formed at the osteotomy end at 4 weeks after operation, and the osteotomy end healed at 8-12 weeks after operation. At last follow-up, the carrying angle, anteversion angle, external rotation range of motion, and extension and flexion range of motion of the elbow joint of the affected side significantly improved when compared with preoperative ones ( P<0.05). Except for the extension range of motion of the healthy elbow joint ( P<0.05), there was no significant difference in other indicators between the two sides ( P>0.05). At last follow-up, the Mayo elbow score was 85-100, with an average of 99.3; 22 cases were excellent, 1 case was good, and the excellent and good rate was 100%.
CONCLUSION
Computer-simulated osteotomy based on health-side combined with guide plate technique for treating cubitus varus deformity in adolescents can achieve precise osteotomy, which has the advantages of short operation time and easy operation, and the short-term effectiveness is satisfactory.
Male
;
Female
;
Humans
;
Adolescent
;
Child, Preschool
;
Child
;
Elbow
;
Humeral Fractures/surgery*
;
Retrospective Studies
;
Joint Deformities, Acquired/surgery*
;
Elbow Joint/surgery*
;
Limb Deformities, Congenital
;
Osteotomy/methods*
;
Humeral Head
;
Range of Motion, Articular
;
Computers
;
Treatment Outcome

Result Analysis
Print
Save
E-mail