1.Effects of resistance combined with aerobic chrono-exercise on common carotid artery elasticity and hemodynamics in young men.
Miao-Xin JIAO ; Bing-Yi SHEN ; Hai-Bin LIU ; Li-Hong CHEN ; Guang-Rui YANG
Acta Physiologica Sinica 2025;77(4):741-751
The purpose of the present study was to investigate the effects of resistance combined with aerobic chrono-exercise on the common carotid artery elasticity and hemodynamics. 24 healthy young men (21.96±0.43 years old) underwent a single acute resistance combined with aerobic exercise intervention at eight time periods (6, 8, 10, 12, 14, 16, 18, and 20 o'clock). The axial flow velocity and diameter waveforms of the common carotid artery were measured, and the hemodynamics were calculated using the classical hemodynamic theory before exercise, immediately after exercise, 10 min and 20 min after exercise. The results showed that during exercise recovery, systolic and mean pressures decreased more markedly after exercise at 8 o'clock (P < 0.05); At 20 min post-exercise, arterial stiffness index and pressure-strain elastic modulus after exercise at 6 o'clock were reduced compared with the resting state, but were significantly elevated after exercise at 20 o'clock (P < 0.05). Immediately after exercise, the pressure rise was higher after exercise at 6 o'clock and the mean wall shear stress was higher after exercise at 20 o'clock (P < 0.05). These results suggest that resistance combined with aerobic chrono-exercise produces different effects on common carotid artery hemodynamics in young men. A single acute session of resistance combined with aerobic exercise at 8 o'clock is more effective in lowering blood pressure. Exercise at 6 o'clock is beneficial to improve arterial elasticity but is not recommended for young male individuals with cardiovascular disease risks because of the excessive increase in blood pressure immediately after exercise. Exercise at 20 o'clock is more effective in improving wall shear stress but is accompanied by elevated arterial stiffness indices and pressure-strain elastic modulus. These results provide a scientific basis for healthy young men in choosing the time of exercise by exploring the common carotid artery elasticity and hemodynamic-related indices.
Humans
;
Male
;
Young Adult
;
Exercise/physiology*
;
Carotid Artery, Common/physiology*
;
Hemodynamics/physiology*
;
Vascular Stiffness/physiology*
;
Elasticity
;
Resistance Training
;
Adult
2.Assessing appropriateness of a developed cephalous analogue for simulation training in performing a Z-plasty by medical practitioners in the Philippines.
Philippine Journal of Surgical Specialties 2025;80(2):57-57
RATIONALE/OBJECTIVE
Simulation-based training allows surgeons to practice technical skills in low-stakes environments. This study aimed to evaluate the appropriateness of a locally developed cephalous tissue analogue model for Z-plasty technique training, addressing the lack of standardized simulation training tools in the Philippines.
METHODSFifteen board-certified plastic surgeons participated, performing the Z-plasty on the cephalous tissue analogue simulator, which was developed using a gelatin, sorbitol, and glycerin mixture reinforced by a mesh base. The participants watched a standardized Zplasty technique video and practiced on the simulator before providing feedback. Face validity was assessed through a Likert-scale questionnaire, with a passing score of 40/50.
RESULTSOf the participants, 93.3% agreed that the model replicated the visual appearance and anatomical orientation necessary for Z-plasty, while 86.6% affirmed its utility in preprocedural planning. However, only 46.7% found the simulator's tissue elasticity adequate, and 20% agreed that it effectively mimicked the interaction between surgical instruments and tissue. The model was unable to consistently retain sutures, particularly for flap corners.
CONCLUSIONThe cephalous tissue analogue model successfully simulated incision and visual orientation but requires refinements in tissue elasticity and suture retention to fully meet training needs for Z-plasty. Future efforts will focus on prototype improvements and content validation to better support simulation-based surgical training.
Human ; Surgeons ; Tissues ; Elasticity ; Glycerol ; Gelatin ; Sorbitol ; Retention (psychology)
3.Factors associated with medication compliance among hypertensive patients in Barangay Sambag II, Cebu City.
Katrina Isabel A. Abesta ; Stacy Gayle N. Auza ; Avinash Suram ; Francis Keith A. Oludin ; Jonathan P. Abrenilla ; Joy Ochoyafie Oche ; Maria Dawn F. Amante ; Millicent C. Abayan ; Pamela Kaye B. Pandili ; Rex Moller Q. Palmes ; Yanilen A. Noynay ; Anacleto Clent L. Banaay jr. ; Marvin C. Masalunga
Acta Medica Philippina 2025;59(Early Access 2025):1-7
BACKGROUND
Medication compliance contributes to preventing significant morbidities, such as stroke, among hypertensive patients.
OBJECTIVEThis study aimed to examine the factors affecting hypertensive patients' medication compliance in Sambag II, Cebu City.
METHODSThis study is an observational cross-sectional study. The study was conducted in Barangay Sambag II of Cebu City and involved 170 random, voluntary, self-reporting hypertensive patients. The Tao Yamane formula was used to determine the sample size. An interviewer-guided survey questionnaire was utilized to collect the data for the pilot study. The data were analyzed using Cronbach’s Alpha Test for internal consistency and reliability.
RESULTSThree factors were shown to influence compliance with antihypertensive medications. These are the source of medication, access to medication, and symptoms experienced before intake of anti-hypertensive medications. A factor that significantly affects compliance is the source of medication, wherein hypertensive patients prefer medications from retail pharmacies compared to the free medications supplied by the local health center.
CONCLUSIONResidents of Sambag II, Cebu City preferred medications from retail pharmacies over the free medications provided by the local health center. Local health units may use this information to implement information drugs regarding the efficacy of medications provided by government agencies. Further studies are recommended to use subgroup analysis on factors influencing compliance and non-compliance to anti-hypertensive medicines.
Human ; Medication Compliance ; Medication Adherence ; Hypertension ; Stroke
4.Correlation analysis between mechanical power normalized to dynamic lung compliance and weaning outcomes and prognosis in mechanically ventilated patients: a prospective, observational cohort study.
Yao YAN ; Yongpeng XIE ; Zhiqiang DU ; Xiaojuan WANG ; Lu LIU ; Meng LI ; Xiaomin LI
Chinese Critical Care Medicine 2025;37(1):36-42
OBJECTIVE:
To explore the correlation between mechanical power normalized to dynamic lung compliance (Cdyn-MP) and weaning outcomes and prognosis in mechanically ventilated patients.
METHODS:
A prospective, observational cohort study was conducted. Patients who underwent invasive mechanical ventilation (IMV) for more than 24 hours and used a T-tube ventilation strategy for extubation in the intensive care unit (ICU) of Lianyungang First People's Hospital and Lianyungang Second People's Hospital between January 2022 and December 2023 were enrolled. The collected data encompassed patients' baseline characteristics, primary causes of ICU admission, vital signs and laboratory indicators during the initial spontaneous breathing trial (SBT), respiratory mechanics parameters within the 4-hour period prior to the SBT, weaning outcomes and prognostic indicators. Mechanical power (MP) and Cdyn-MP were calculated using a simplified MP equation. Univariate and multivariate Logistic regression analyses were utilized to determine the independent risk factors associated with weaning failure in patients undergoing mechanical ventilation. Restricted cubic spline (RCS) analysis and Spearman rank-sum test were employed to investigate the correlation between Cdyn-MP and weaning outcomes as well as prognosis. Receiver operator characteristic curve (ROC curve) was constructed, and the area under the ROC curve (AUC) was computed to evaluate the predictive accuracy of Cdyn-MP for weaning outcomes in mechanically ventilated patients.
RESULTS:
A total of 366 patients undergoing IMV were enrolled in this study, with 243 cases classified as successful weaning and 123 cases classified as failed weaning. Among them, 23 patients underwent re-intubation within 48 hours after the successful withdrawal of the first SBT, non-invasive ventilation, or died. Compared with the successful weaning group, the patients in the failed weaning group had significantly increased levels of sequential organ failure assessment (SOFA) score, body temperature and respiratory rate (RR) during SBT, and respiratory mechanical parameters within the 4-hour period prior to the SBT [ventilation frequency, positive end-expiratory pressure (PEEP), platform pressure (Pplat), peak inspiratory pressure (Ppeak), dynamic driving pressure (ΔPaw), fraction of inspired oxygen (FiO2), MP, and Cdyn-MP], dynamic lung compliance (Cdyn) was significantly reduced, and duration of IMV, ICU length of stay, and total length of hospital stay were significantly prolonged. However, there were no statistically significant differences in age, gender, body mass index (BMI), smoking history, main causes of ICU admission, other vital signs [heart rate (HR), mean arterial pressure (MAP), saturation of peripheral oxygen (SpO2)] and laboratory indicators [white blood cell count (WBC), albumin (Alb), serum creatinine (SCr)] during SBT of patients between the two groups. Univariate Logistic regression analysis was conducted, and variables with P < 0.05 and no multicollinearity with Cdyn-MP were selected for inclusion in the multivariate Logistic regression model. The results demonstrated that SOFA score [odds ratio (OR) = 1.081, 95% confidence interval (95%CI) was 1.008-1.160, P = 0.030], and PEEP (OR = 1.191, 95%CI was 1.075-1.329, P = 0.001), FiO2 (OR = 1.035, 95%CI was 1.006-1.068, P = 0.021) and Cdyn-MP (OR = 1.190, 95%CI was 1.086-1.309, P < 0.001) within the 4-hour period prior to the SBT were independent risk factors for weaning failure in patients undergoing IMV. The RCS analysis after adjusting for confounding factors showed that as Cdyn-MP within the 4-hour period prior to the SBT increased, the risk of weaning failure in patients undergoing IMV significantly increased (P < 0.001). The Spearman rank correlation test showed that Cdyn-MP within the 4-hour period prior to the SBT was positively correlated with respiratory mechanical parameters including ΔPaw and MP (r values were 0.773 and 0.865, both P < 0.01), and negatively correlated with Cdyn (r = -0.587, P < 0.01). Cdyn-MP within the 4-hour period prior to the SBT was positively correlated with prognostic indicators such as duration of IMV, length of ICU stay, and total length of hospital stay (r values were 0.295, 0.196, and 0.120, all P < 0.05). ROC curve analysis demonstrated that, within the 4-hour period preceding the SBT, Cdyn-MP, MP, Cdyn, and ΔPaw possessed predictive value for weaning failure in patients undergoing IMV. Notably, Cdyn-MP exhibited superior predictive capability, evidenced by an AUC of 0.761, with a 95%CI ranging from 0.712 to 0.810 (P < 0.001). At the optimal cut-off value of 408.5 J/min×cmH2O/mL×10-3, the sensitivity was 68.29%, and the specificity was 71.19%.
CONCLUSION
Cdyn-MP is related to weaning outcomes and prognosis in mechanically ventilated patients, and has good predictive ability in assessing the risk of weaning failure.
Humans
;
Prospective Studies
;
Ventilator Weaning
;
Prognosis
;
Respiration, Artificial
;
Intensive Care Units
;
Lung Compliance
;
Female
;
Male
;
Middle Aged
;
Aged
5.Clinical exploration and practice of a 16-step new model of comfortable supragingival scaling.
Yue CHEN ; Jinyang LI ; Yazheng WANG ; Jing LI ; Jin LIU ; Yumeng ZHOU ; Ang LI
West China Journal of Stomatology 2025;43(5):628-635
Comfortable supragingival scaling uses ultrasonic cleaning with sedation and minimally invasive techniques to minimize the negative emotions of patients and improve patient compliance. At present, there is still much room for optimization of the environment, equipment, and operation steps for the development of comfortable supragingival scaling. On this basis, the Department of Periodontology, College of Stomatology, Xi'an Jiaotong University proposed a 16-step new model of comfortable supragingival scaling. The new model incorporates adjustments to the previous model concerning the environment, equipment, operational procedures, process links and services, comprising 16 steps for optimization and innovation. Clinical practice has confirmed that the 16-step new model of comfortable supra-gingival scaling can significantly improve patient satisfaction and adherence to medical treatment, and it has good promotional value.
Humans
;
Dental Scaling/instrumentation*
;
Patient Satisfaction
;
Patient Compliance
;
Gingiva
6.Factors associated with medication compliance among hypertensive patients in Barangay Sambag II, Cebu City.
Katrina Isabel A. ABESTA ; Stacy Gayle N. AUZA ; Avinash SURAM ; Francis Keith A. OLUDIN ; Jonathan P. ABRENILLA ; Joy Ochoyafie OCHE ; Maria Dawn F. AMANTE ; Millicent C. ABAYAN ; Pamela Kaye B. PANDILI ; Rex Moller Q. PALMES ; Yanilen A. NOYNAY ; Anacleto Clent L. BANAAY JR. ; Marvin C. MASALUNGA
Acta Medica Philippina 2025;59(18):9-15
BACKGROUND
Medication compliance contributes to preventing significant morbidities, such as stroke, among hypertensive patients.
OBJECTIVEThis study aimed to examine the factors affecting hypertensive patients' medication compliance in Sambag II, Cebu City.
METHODSThis study is an observational cross-sectional study. The study was conducted in Barangay Sambag II of Cebu City and involved 170 random, voluntary, self-reporting hypertensive patients. The Tao Yamane formula was used to determine the sample size. An interviewer-guided survey questionnaire was utilized to collect the data for the pilot study. The data were analyzed using Cronbach’s Alpha Test for internal consistency and reliability.
RESULTSThree factors were shown to influence compliance with antihypertensive medications. These are the source of medication, access to medication, and symptoms experienced before intake of anti-hypertensive medications. A factor that significantly affects compliance is the source of medication, wherein hypertensive patients prefer medications from retail pharmacies compared to the free medications supplied by the local health center.
CONCLUSIONResidents of Sambag II, Cebu City preferred medications from retail pharmacies over the free medications provided by the local health center. Local health units may use this information to implement information drugs regarding the efficacy of medications provided by government agencies. Further studies are recommended to use subgroup analysis on factors influencing compliance and non-compliance to anti-hypertensive medicines.
Human ; Medication Compliance ; Medication Adherence ; Hypertension ; Stroke
7.A study on the predictive model of porous hyperelastic properties of human alveolar bone based on computed tomography imaging.
Bin WU ; Mingna LI ; Fan YANG ; Le YUAN ; Yi LU ; Di JIANG ; Yang YI ; Bin YAN
Journal of Biomedical Engineering 2025;42(2):359-365
Alveolar bone reconstruction simulation is an effective means for quantifying orthodontics, but currently, it is not possible to directly obtain human alveolar bone material models for simulation. This study introduces a prediction method for the equivalent shear modulus of three-dimensional random porous materials, integrating the first-order Ogden hyperelastic model to construct a computed tomography (CT) based porous hyperelastic Ogden model (CT-PHO) for human alveolar bone. Model parameters are derived by combining results from micro-CT, nanoindentation experiments, and uniaxial compression tests. Compared to previous predictive models, the CT-PHO model shows a lower root mean square error (RMSE) under all bone density conditions. Simulation results using the CT-PHO model parameters in uniaxial compression experiments demonstrate more accurate prediction of the mechanical behavior of alveolar bone under compression. Further prediction and validation with different individual human alveolar bone samples yield accurate results, confirming the generality of the CT-PHO model. The study suggests that the CT-PHO model proposed in this paper can estimate the material properties of human alveolar bone and may eventually be used for bone reconstruction simulations to guide clinical treatment.
Humans
;
Tomography, X-Ray Computed/methods*
;
Porosity
;
Alveolar Process/physiology*
;
Bone Density
;
Computer Simulation
;
Elasticity
;
X-Ray Microtomography
;
Stress, Mechanical
;
Finite Element Analysis
;
Models, Biological
8.Effects of elastic modulus of the metal block on the condylar-constrained knee prosthesis tibial fixation stability.
Yuhan ZHANG ; Jing ZHANG ; Tianqi DONG ; Xuan ZHANG ; Weijie ZHANG ; Lei GUO ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(4):782-789
Although metal blocks have been widely used for reconstructing uncontained tibial bone defects, the influence of their elastic modulus on the stability of tibial prosthesis fixation remains unclear. Based on this, a finite element model incorporating constrained condylar knee (CCK) prosthesis, tibia, and metal block was established. Considering the influence of the post-restraint structure of the prosthesis, the effects of variations in the elastic modulus of the block on the von Mises stress distribution in the tibia and the block, as well as on the micromotion at the bone-prosthesis fixation interface, were investigated. Results demonstrated that collision between the insert post and femoral prosthesis during tibial internal rotation increased tibial von Mises stress, significantly influencing the prediction of block elastic modulus variation. A decrease in the elastic modulus of the metal block resulted in increased von Mises stress in the proximal tibia, significantly reduced von Mises stress in the distal tibia, decreased von Mises stress of the block, and increased micromotion at the bone-prosthesis fixation interface. When the elastic modulus of the metal block fell below that of bone cement, inadequate block support substantially increased the risk of stress shielding in the distal tibia and fixation interface loosening. Therefore, this study recommends that biomechanical investigations of CCK prostheses must consider the post-constraint effect, and the elastic modulus of metal blocks for bone reconstruction should not be lower than 3 600 MPa.
Knee Prosthesis
;
Humans
;
Finite Element Analysis
;
Tibia/surgery*
;
Elastic Modulus
;
Arthroplasty, Replacement, Knee/methods*
;
Stress, Mechanical
;
Metals
;
Prosthesis Design
;
Knee Joint/surgery*
;
Biomechanical Phenomena
9.Impact of posterior cruciate ligament resection on the elasticity of the periarticular soft tissue sleeve in the knee joint.
Yun-Feng ZHANG ; De-Jin YANG ; Zhao-Lun WANG ; Yi-Xin ZHOU ; Hao TANG ; Xiang-Dong WU ; Han-Long ZHENG
China Journal of Orthopaedics and Traumatology 2025;38(10):1055-1060
OBJECTIVE:
To evaluate the effects of posterior cruciate ligament(PCL) resection on soft tissue elasticity and knee stability in total knee arthroplasty(TKA).
METHODS:
Six adult cadaveric knee specimens (involving 10 knees) were included in the study. With the assistance of the robotic system(TiRobot Recon, TINAVI, Beijing), total knee arthroplasty (TKA) was performed sequentially using cruciate retaining (CR) prostheses and posterior stabilizing (PS) prostheses. Between the two surgical procedures, the femoral and tibial osteotomy surfaces were not altered;only the posterior cruciate ligament (PCL) was resected and the intercondylar fossa was treated. After installing the femoral trial component, a soft tissue balance solver was used to apply tension ranging from 30 N to 90 N in 5 N increments at 0°, 10°, and 90° of knee flexion. Meanwhile, the medial and lateral joint gaps were measured synchronously. Based on the tension-gap coupling data, the equivalent elastic coefficients of the medial and lateral soft tissue sleeves at different knee flexion angles, as well as the range of the joint line convergence angle (JLCA) under fixed varus-valgus stress, were calculated. Additionally, the gap balance status under 80 N of tension was analyzed. Self-control comparisons of each indicator were conducted before and after PCL resection to analyze the change patterns.
RESULTS:
After PCL resection, in the fully extended position (knee flexion 0°). The medial equivalent elastic coefficient was 32.2 (25.7, 63.3) N·mm-1 for the CR prosthesis and 27.7 (22.0, 51.9) N·mm-1 for the PS prosthesis, and the statistically significant difference (P=0.013). The range of JLCA was 0.41°(0.26, 0.55)° for the CR prosthesis, which was smaller than 0.75° (0.40, 0.98)° for the PS prosthesis, and the difference was statistically significant(P=0.041). At 90° of knee flexion, the medial joint gap was 10.7(10.1, 11.7) mm for the CR prosthesis, which was smaller than 12.1(10.9, 15.1) mm for the PS prosthesis, with a statistically significant difference(P=0.011). No statistically significant differences were observed in other joint gaps.
CONCLUSION
PCL resection reduces the rigidity of the medial soft tissues in the fully extended knee and increases the medial joint gap in the flexed position, thereby affecting knee stability and balance. This finding suggests that PS and CR prostheses may require different morphological designs, and there should be differences in indications and osteotomy strategies between CR-TKA and PS-TKA. CR-TKA is more suitable for patients with preoperative medial soft tissue laxity.
Humans
;
Posterior Cruciate Ligament/physiopathology*
;
Knee Joint/physiopathology*
;
Arthroplasty, Replacement, Knee
;
Elasticity
;
Male
;
Female
;
Middle Aged
;
Aged
;
Biomechanical Phenomena
;
Adult
10.Imaging analysis of the posterior occipital muscles in cervical vertigo based on shear wave elastography.
Ying-Sen PAN ; Yi SHEN ; Fei-Peng QIN ; Hao-Yang ZHANG ; Nao LIU ; Yan-Jun XU ; Xiao-Ming YING
China Journal of Orthopaedics and Traumatology 2025;38(11):1126-1132
OBJECTIVE:
To evaluate the partial biomechanical properties of the posterior occipital muscles (rectus capitis posterior major, rectus capitis posterior minor, and obliquus capitis inferior) in patients with cervical vertigo.
METHODS:
A total of 30 patients with cervical vertigo admitted from April 2024 to September 2024 were included in the vertigo group, and 30 age-and gender-matched healthy subjects were recruited as the normal group. In the vertigo group, there were 21 females and 9 males, with an average age of (24.00±2.25) years;in the normal group, there were 22 females and 8 males, with an average age of (23.00±3.00) years. Shear wave elastography was used to measure the thickness and stiffness of the posterior occipital muscles in both groups.
RESULTS:
In the vertigo group, there were no statistically significant differences in the Young's modulus values (E) of stiffness of the posterior occipital muscles (rectus capitis posterior major, rectus capitis posterior minor, obliquus capitis inferior) between the left and right sides(P>0.05). The Young's modulus values(E) of stiffness of the right posterior occipital muscles (rectus capitis posterior major, rectus capitis posterior minor, obliquus capitis inferior) in the cervical vertigo group were (39.66±8.21) kPa, (45.61±5.85) kPa, and (43.73±5.22) kPa, respectively, which were significantly higher than those in the normal group 33.97(17.76) kPa, 41.38(8.99) kPa, 38.27(12.58) kPa, with statistically significant differences (P<0.05). In the vertigo group, the Young's modulus values(E) of stiffness of the left rectus capitis posterior major and left obliquus capitis inferior were (40.41±9.13) kPa and (42.11±6.20) kPa, respectively, which were significantly greater than those in the normal group (33.30±11.31) kPa, 38.94(14.62) kPa, with statistically significant differences(P<0.05);however, there was no statistically significant difference in the left rectus capitis posterior minor between the two groups(P>0.05). In the vertigo group, there were no statistically significant differences in the stiffness of the posterior occipital muscles (rectus capitis posterior major, rectus capitis posterior minor, obliquus capitis inferior) between the left and right sides(P>0.05). Additionally, there were no statistically significant differences in the thickness of the bilateral posterior occipital muscles between the vertigo group and the normal group (P>0.05).
CONCLUSION
The posterior occipital muscles of patients with cervical vertigo are stiffer than those of healthy individuals, while there is no significant difference in muscle thickness between the two groups.
Humans
;
Female
;
Male
;
Elasticity Imaging Techniques/methods*
;
Adult
;
Vertigo/physiopathology*
;
Neck Muscles/physiopathology*
;
Young Adult


Result Analysis
Print
Save
E-mail