1.Diagnostic Accuracy of Serological Tests for Mycoplasma pneumoniae Infections in Children with Pneumonia, Based on Symptom Onset
Gahee KIM ; Ki Wook YUN ; Dayun KANG ; Taek Jin LEE ; Byung Wook EUN ; Hyunju LEE ; Yae-Jean KIM ; Doo Ri KIM ; Areum SHIN ; Hyun Mi KANG ; Ye Ji KIM ; Byung Ok KWAK ; Younghee LEE ; Ye Kyung KIM ; Young June CHOE ; Woosuck SUH ; Kyo Jin JO ; Kyung-Ran KIM ; Eun Young CHO ; Kyung Min KIM ; Joon Kee LEE ; Su Eun PARK
Annals of Laboratory Medicine 2026;46(2):162-170
Background:
Mycoplasma pneumoniae is a major cause of community-acquired pneumonia (CAP) in children, with a rising incidence of macrolide resistance. Early diagnosis is crucial for reducing the disease burden; however, current diagnostic tools have limitations.We evaluated the diagnostic accuracy of serological assays and their performance based on symptom onset in children with CAP.
Methods:
From September 2023 to September 2024, we prospectively enrolled children with CAP, classified as M. pneumoniae pneumonia (MPP) or non-MPP, from 16 hospitals in Korea. Serological testing included chemiluminescence immunoassay (CLIA) and ELISA for detecting IgM and IgG, along with particle agglutination (PA) for total antibody measurements. Serological responses were analyzed at different times after symptom onset (0–4, 5–9, and 10–21 days).
Results:
Among 472 children with CAP (362 MPP, 110 non-MPP), 138 (29.2%) underwent PA testing, and 334 (70.8%) underwent IgM testing. PA at a 1:640 cutoff showed 48.0% sensitivity and 100% specificity. CLIA and ELISA showed comparable sensitivities (69.1% vs. 69.2%) and specificities (76.9% vs. 66.7%) for IgM testing. Seropositivity increased significantly with time since symptom onset (P for trend < 0.001), reaching 97.9% for IgM, 62.5% for IgG, and 94.7% for PA at 10–21 days.
Conclusions
The time post-symptom onset significantly influenced the diagnostic utility of serological tests for pediatric MPP, which showed limited value during the early stage of illness. These findings emphasize the importance of symptom onset-based interpretation of serological test results and their utility in complementing PCR when optimizing MPP diagnosis in children.
2.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
3.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
6.Artificial Intelligence-Guided Mobile Telerehabilitation for Individuals With Cognitive Impairment: A Feasibility Study
Suebeen KIM ; Doo Young KIM ; Si-Woon PARK ; Namo JEON ; Taeksoo JEONG ; Min-Soo KANG ; Sangwook PARK
Annals of Rehabilitation Medicine 2025;49(6):371-380
Objective:
To test the feasibility and usability of an artificial intelligence (AI)-guided mobile cognitive telerehabilitation program for patients with stroke or older adults with mild cognitive impairment (MCI).
Methods:
Thirteen participants with cognitive impairment (Mini-Mental State Examination [MMSE] score≤26; nine with stroke and four with MCI) were enrolled in the study. Each participant was provided with an AI-guided mobile cognitive rehabilitation program (Zenicog®). Participants were instructed to complete 24 sessions within 6 weeks, and those with sufficient adherence (≥70%, 17 sessions) were included in the analysis. Cognitive assessments included the MMSE, digit span, and Trail Making Tests A & B. The usability questionnaire investigated equitable use and flexibility in use, simple and intuitive use, perceptible information, tolerance for error, low physical effort, size and space for use, overall product quality, overall satisfaction.
Results:
Eleven participants completed the study, and 10 participants met adherence criteria. The MMSE score increased significantly from 24.00 [21.00, 25.75] at baseline to 27.50 [26.00, 28.75] after intervention. The overall product quality (Likert scale: 1–5) score was 4.00±0.87. The lowest score in the usability questionnaire was for tolerance for error. Female participants and participants with <12 years’ education gave lower scores for tolerance for error and equitable/ flexibility in use, respectively.
Conclusion
The AI-guided mobile cognitive telerehabilitation program is feasible and potentially beneficial for improving cognitive function in patients with stroke or older adults with MCI. Individuals who are less familiar with electronic devices require special consideration to improve their usability.
7.Molecular and Treatment Characteristics of SMARCB1 or SMARCA4-Deficient Undifferentiated Tumor: Retrospective Case Series
Hyeon Gyu KANG ; Jiwon KOH ; Tae Min KIM ; Doo Hee HAN ; Tae-Bin WON ; Dong-Wan KIM ; Dong-Young KIM ; Bhumsuk KEAM
Cancer Research and Treatment 2024;56(3):967-971
SMARCB1 or SMARCA4-deficient sinonasal carcinoma or thoracic undifferentiated tumor has aggressive nature with a poor prognosis. Patients with this disease were diagnosed by immunohistochemistry or next-generation sequencing. Those who were able to receive a surgery tended to be cured, while the others treated with chemotherapy, radiation therapy, or immune checkpoint inhibitor were often insensitive to these therapies. However, one having CD274 (PD-L1) amplification showed the response to immune checkpoint inhibitor and a good prognosis. We believed that this report could provide promising information for determining the optimal treatment option.
8.Clinical Outcome after Everolimus-Eluting Stent Implantation for Small Vessel Coronary Artery Disease: XIENCE Asia Small Vessel Study
Doo Sun SIM ; Dae Young HYUN ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Myung Ho JEONG ; Sang Rok LEE ; Jei Keon CHAE ; Keun Ho PARK ; Young Youp KOH ; Kyeong Ho YUN ; Seok Kyu OH ; Seung Jae JOO ; Sun Ho HWANG ; Jong Pil PARK ; Jay Young RHEW ; Su Hyun KIM ; Jang Hyun CHO ; Seung Uk LEE ; Dong Goo KANG
Chonnam Medical Journal 2024;60(1):78-86
There are limited data on outcomes after implantation of everolimus-eluting stents (EES) in East Asian patients with small vessel coronary lesions. A total of 1,600 patients treated with XIENCE EES (Abbott Vascular, CA, USA) were divided into the small vessel group treated with one ≤2.5 mm stent (n=119) and the non-small vessel group treated with one ≥2.75 mm stent (n=933). The primary end point was a patient-oriented composite outcome (POCO), a composite of all-cause death, myocardial infarction (MI), and any repeat revascularization at 12 months. The key secondary end point was a device-oriented composite outcome (DOCO), a composite of cardiovascular death, target-vessel MI, and target lesion revascularization at 12 months. The small vessel group was more often female, hypertensive, less likely to present with ST-elevation MI, and more often treated for the left circumflex artery, whereas the non-small vessel group more often had type B2/C lesions, underwent intravascular ultrasound, and received unfractionated heparin. In the propensity matched cohort, the mean stent diameter was 2.5±0.0 mm and 3.1±0.4 mm in the small and non-small vessel groups, respectively. Propensity-adjusted POCO at 12 months was 6.0% in the small vessel group and 4.3% in the non-small vessel group (p=0.558). There was no significant difference in DOCO at 12 months (small vessel group: 4.3% and non-small vessel group: 1.7%, p=0.270).Outcomes of XIENCE EES for small vessel disease were comparable to those for non-small vessel disease at 12-month clinical follow-up in real-world Korean patients.
9.Efficacy and Safety of Lurasidone vs. Quetiapine XR in Acutely Psychotic Patients With Schizophrenia in Korea: A Randomized, Double-Blind, Active-Controlled Trial
Se Hyun KIM ; Do-Un JUNG ; Do Hoon KIM ; Jung Sik LEE ; Kyoung-Uk LEE ; Seunghee WON ; Bong Ju LEE ; Sung-Gon KIM ; Sungwon ROH ; Jong-Ik PARK ; Minah KIM ; Sung Won JUNG ; Hong Seok OH ; Han-yong JUNG ; Sang Hoon KIM ; Hyun Seung CHEE ; Jong-Woo PAIK ; Kyu Young LEE ; Soo In KIM ; Seung-Hwan LEE ; Eun-Jin CHEON ; Hye-Geum KIM ; Heon-Jeong LEE ; In Won CHUNG ; Joonho CHOI ; Min-Hyuk KIM ; Seong-Jin CHO ; HyunChul YOUN ; Jhin-Goo CHANG ; Hoo Rim SONG ; Euitae KIM ; Won-Hyoung KIM ; Chul Eung KIM ; Doo-Heum PARK ; Byung-Ook LEE ; Jungsun LEE ; Seung-Yup LEE ; Nuree KANG ; Hee Yeon JUNG
Psychiatry Investigation 2024;21(7):762-771
Objective:
This study was performed to evaluate the efficacy and safety of lurasidone (160 mg/day) compared to quetiapine XR (QXR; 600 mg/day) in the treatment of acutely psychotic patients with schizophrenia.
Methods:
Patients were randomly assigned to 6 weeks of double-blind treatment with lurasidone 160 mg/day (n=105) or QXR 600 mg/day (n=105). Primary efficacy measure was the change from baseline to week 6 in Positive and Negative Syndrome Scale (PANSS) total score and Clinical Global Impressions severity (CGI-S) score. Adverse events, body measurements, and laboratory parameters were assessed.
Results:
Lurasidone demonstrated non-inferiority to QXR on the PANSS total score. Adjusted mean±standard error change at week 6 on the PANSS total score was -26.42±2.02 and -27.33±2.01 in the lurasidone and QXR group, respectively. The mean difference score was -0.91 (95% confidence interval -6.35–4.53). The lurasidone group showed a greater reduction in PANSS total and negative subscale on week 1 and a greater reduction in end-point CGI-S score compared to the QXR group. Body weight, body mass index, and waist circumference in the lurasidone group were reduced, with significantly lower mean change compared to QXR. Endpoint changes in glucose, cholesterol, triglycerides, and low-density lipoprotein levels were also significantly lower. The most common adverse drug reactions with lurasidone were akathisia and nausea.
Conclusion
Lurasidone 160 mg/day was found to be non-inferior to QXR 600 mg/day in the treatment of schizophrenia with comparable efficacy and tolerability. Adverse effects of lurasidone were generally tolerable, and beneficial effects on metabolic parameters can be expected.
10.The Impact of an Antimicrobial Stewardship Program on Days of Therapy in the Pediatric Center:An Interrupted Time-Series Analysis of a 19-Year Study
Kyung-Ran KIM ; Hyo Jung PARK ; Sun-Young BAEK ; Soo-Han CHOI ; Byung-Kee LEE ; SooJin KIM ; Jong Min KIM ; Ji-Man KANG ; Sun-Ja KIM ; Sae Rom CHOI ; Dongsub KIM ; Joon-sik CHOI ; Yoonsun YOON ; Hwanhee PARK ; Doo Ri KIM ; Areum SHIN ; Seonwoo KIM ; Yae-Jean KIM
Journal of Korean Medical Science 2024;39(21):e172-
Background:
We aimed to analyze the effects of an antimicrobial stewardship program (ASP) on the proportion of antimicrobial-resistant pathogens in bacteremia, antimicrobial use, and mortality in pediatric patients.
Methods:
A retrospective single-center study was performed on pediatric inpatients under 19 years old who received systemic antimicrobial treatment from 2001 to 2019. A pediatric infectious disease attending physician started ASP in January 2008. The study period was divided into the pre-intervention (2001–2008) and the post-intervention (2009–2019) periods. The amount of antimicrobial use was defined as days of therapy per 1,000 patientdays, and the differences were compared using delta slope (= changes in slopes) between the two study periods by an interrupted time-series analysis. The proportion of resistant pathogens and the 30-day overall mortality rate were analyzed by the χ2 .
Results:
The proportion of extended-spectrum beta-lactamase (ESBL)-producing Escherichia coli and Klebsiella pneumoniae bacteremia increased from 17% (39 of 235) in the pre-intervention period to 35% (189 of 533) in the post-intervention period (P < 0.001). The total amount of antimicrobial use significantly decreased after the introduction of ASP (delta slope value = −16.5; 95% confidence interval [CI], −30.6 to −2.3; P = 0.049). The 30-day overall mortality rate in patients with bacteremia did not increase, being 10% (55 of 564) in the pre-intervention and 10% (94 of 941) in the post-intervention period (P = 0.881).
Conclusion
The introduction of ASP for pediatric patients reduced the delta slope of the total antimicrobial use without increasing the mortality rate despite an increased incidence of ESBL-producing gram-negative bacteremia.

Result Analysis
Print
Save
E-mail