1.Clinical Outcomes and Use of Implantable Cardioverter-Defibrillator in Ischemic Heart Failure Patients with Reduced Ejection Fraction:A Retrospective Observational Study
Kyung Hoon CHO ; Ki Hong LEE ; Yong-Kyu LEE ; Seok OH ; Yongwhan LIM ; Joon Ho AHN ; Seung Hun LEE ; Dae Young HYUN ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Jang Hoon LEE ; Joo-Yong HAHN ; Yu-Ri KIM ; Nam Sik YOON ; Hyung Wook PARK ; Weon KIM ; Myung Ho JEONG ;
Chonnam Medical Journal 2026;62(2):55-63
Limited data exist regarding the real-world practices and clinical outcomes in patients with ischemic heart failure with reduced left ventricular ejection fractions (LVEFs).Using nationwide registry data from South Korea, we aimed to investigate long-term outcomes and clinical practices, especially implantable cardioverter defibrillators (ICDs) implantation, in patients with reduced LVEFs at least 40 days after acute myocardial infarction (AMI). Of 13,056 patients with AMI between 2011 and 2015, we analyzed 350 (median age, 66 years [interquartile range, 56-75]) who had LVEFs <40% on follow-up transthoracic echocardiogram 40 days after the index event. The primary outcome was cardiac-cause mortality at 3 years. Secondary outcomes comprised major cardiovascular events as well as outcomes defined by the use of ICDs, cardiac resynchronization therapy defibrillators (CRT-Ds), and electrophysiology studies. Among 350 patients, 39 (11.1%) died from cardiac causes during 3 years of follow-up. Eleven (3.1%) were hospitalized for ventricular tachycardia. The rate of ICD or CRT-D implantation up to 3 years was 5.7% (20/350). Cox time-to-event analysis revealed older age, LVEF <30%, diabetes mellitus, and previous MI or revascularization as positively associated with cardiac death, whereas the use of statins and body weight <67 kg were negatively associated. This nationwide Korean registry demonstrated that only 5.7% of patients who had reduced LVEFs after 40 days of AMI underwent ICD implantations over 3 years. Considering the high mortality, concerted efforts are needed to improve clinical outcomes for patients who may have been candidates for ICD implantation.
2.Management of Abrupt Vessel Closure During Percutaneous Coronary Intervention: A Narrative Review
Yongwhan LIM ; Seok OH ; Joon Ho AHN ; Seung Hun LEE ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN
Journal of Cardiovascular Intervention 2026;5(1):1-10
Abrupt vessel closure (AVC) is a complication of percutaneous coronary intervention (PCI) and is defined as the sudden cessation of forward coronary blood flow due to a variety of mechanisms. The incidence of AVC has markedly decreased from approximately 3.0% in the early era to about 0.3% today. Nevertheless, cardiovascular interventionists must remain prepared to manage AVC effectively, given its significant impact on clinical outcomes.AVC can arise from several mechanisms, including dissection, intramural hematoma, intracoronary thrombosis, air embolism, vasospasm, and no-reflow. The clinical impact of AVC varies depending on the extent of myocardium affected, ranging from asymptomatic events or transient ischemic chest pain to cardiogenic shock or cardiac arrest. Both a general approach for stabilizing hemodynamic consequences and an etiology-specific management strategy are essential. Hasty decision-making may worsen the situation, whereas a structured approach—focused on hemodynamic stabilization, logical diagnostic processes, and targeted interventions—can improve outcomes. In this narrative review, we describe the mechanisms underlying each etiology, outline mechanism-specific management strategies, and discuss general approaches to managing patients with AVC through logical diagnostic and treatment processes. We hope this review offers valuable insights into this uncommon but significant complication and enhances readers’ skills in managing AVC more effectively during PCI.
3.Risk Factors of Complications in Patients With Persistent or Long-Standing Persistent Atrial Fibrillation/Atrial Flutter Who Underwent Electrical Cardioversion:A Multicenter Cardioversion Registry
Ki-Hun KIM ; Junbeom PARK ; Donghwan KU ; Jino PARK ; Seunghwan KIM ; Dong-Kie KIM ; Doo-Il KIM ; Sun Gyu CHOI ; Pil-Sung YANG ; Ju Youn KIM ; Jaemin SHIM ; Jinhee AHN ; Sung Ho LEE ; Sung Il IM ; Hong Euy LIM
Journal of Korean Medical Science 2026;41(1):e19-
Background:
Identifying the risks related to the complications of electrical cardioversion (ECV) can alert the determinaton of rhythm control in patients with atrial fibrillation (AF).
Methods:
We retrospectively reviewed 1,058 patients who underwent ECV for persistent or long-standing persistent AF/atrial flutter (AFL) from multiple centers. Patients were classified into the no-complication (1,023 patients) and complication (35 patients) groups based on the following major complications: stroke and/or systemic embolism (SSE), myocardial infarction, major bleeding, implantation of cardiac implantable electronic devices, ventricular tachycardia/fibrillation, and death at 1 year follow-up after ECV.
Results:
Compared with the no-complication group, the complication group exhibited a higher proportion of female patients (37% vs. 22%), as well as a higher proportion of patients with older age (67 ± 11 vs. 61 ± 10 years), diabetes mellitus (DM) (49% vs. 24%), heart failure (HF) (49% vs. 30%), SSE (23% vs. 9%), high CHA 2 DS 2 -VASc (CV) score (3.6 ± 1.8 vs.2.2 ± 1.4), low left ventricular ejection fraction (LVEF) (50 ± 16% vs. 58 ± 21%), and high left atrial volume index (LAVI) (51 ± 26 vs. 40 ± 20 mL/m 2 ). Class I and III antiarrhythmics were less prescribed in the complication group than in the no-complication group (57% vs.76%). Univariate analysis for complications revealed age (≥ 65 years), female sex, DM, HF, SSE, LVEF (< 50%), LAVI (≥ 40 mL/m 2 ), CV score (≥ 3), bradycardia on Holter (< 60/min), and no antiarrhythmics as risk factors. Among these, multivariate analysis revealed clinical significance of female sex and SSE.
Conclusion
Female sex and a history of SSE were the most important risk factors of complications in patients with persistent or long-standing persistent AF/AFL who underwent ECV.
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.
6.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.
7.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
8.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
9.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
10.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.

Result Analysis
Print
Save
E-mail