1.Evaluation of the performance of the artificial intelligence - enabled snail identification system for recognition of Oncomelania hupensis robertsoni and Tricula
Jihua ZHOU ; Shaowen BAI ; Liang SHI ; Jianfeng ZHANG ; Chunhong DU ; Jing SONG ; Zongya ZHANG ; Jiaqi YAN ; Andong WU ; Yi DONG ; Kun YANG
Chinese Journal of Schistosomiasis Control 2025;37(1):55-60
Objective To evaluate the performance of the artificial intelligence (AI)-enabled snail identification system for recognition of Oncomelania hupensis robertsoni and Tricula in schistosomiasis-endemic areas of Yunnan Province. Methods Fifty O. hupensis robertsoni and 50 Tricula samples were collected from Yongbei Township, Yongsheng County, Lijiang City, a schistosomiasis-endemic area in Yunnan Province in May 2024. A total of 100 snail sample images were captured with smartphones, including front-view images of 25 O. hupensis robertsoni and 25 Tricula samples (upward shell opening) and back-view images of 25 O. hupensis robertsoni and 25 Tricula samples (downward shell opening). Snail samples were identified as O. hupensis robertsoni or Tricula by schistosomiasis control experts with a deputy senior professional title and above according to image quality and morphological characteristics. A standard dataset for snail image classification was created, and served as a gold standard for recognition of snail samples. A total of 100 snail sample images were recognized with the AI-enabled intelligent snail identification system based on a WeChat mini program in smartphones. Schistosomiasis control professionals were randomly sampled from stations of schistosomisis prevention and control and centers for disease control and prevention in 18 schistosomiasis-endemic counties (districts, cities) of Yunnan Province, for artificial identification of 100 snail sample images. All professionals are assigned to two groups according the median years of snail survey experiences, and the effect of years of snail survey experiences on O. hupensis robertsoni sample image recognition was evaluated. A receiver operating characteristic (ROC) curve was plotted, and the sensitivity, specificity, accuracy, Youden’s index and the area under the curve (AUC) of the AI-enabled intelligent snail identification system and artificial identification were calculated for recognition of snail sample images. The snail sample image recognition results of AI-enabled intelligent snail identification system and artificial identification were compared with the gold standard, and the internal consistency of artificial identification results was evaluated with the Cronbach’s coefficient alpha. Results A total of 54 schistosomiasis control professionals were sampled for artificial identification of snail sample image recognition, with a response rate of 100% (54/54), and the accuracy, sensitivity, specificity, Youden’s index, and AUC of artificial identification were 90%, 86%, 94%, 0.80 and 0.90 for recognition of snail sample images, respectively. The overall Cronbach’s coefficient alpha of artificial identification was 0.768 for recognition of snail sample images, and the Cronbach’s coefficient alpha was 0.916 for recognition of O. hupensis robertsoni snail sample images and 0.925 for recognition of Tricula snail sample images. The overall accuracy of artificial identification was 90% for recognition of snail sample images, and there was no significant difference in the accuracy of artificial identification for recognition of O. hupensis robertsoni (86%) and Tricula snail sample images (94%) (χ2 = 1.778, P > 0.05). There was no significant difference in the accuracy of artificial identification for recognition of snail sample images with upward (88%) and downward shell openings (92%) (χ2 = 0.444, P > 0.05), and there was a significant difference in the accuracy of artificial identification for recognition of snail sample images between schistosomiasis control professionals with snail survey experiences of 6 years and less (75%) and more than 6 years (90%) (χ2 = 7.792, P < 0.05). The accuracy, sensitivity, specificity and AUC of the AI-enabled intelligent snail identification system were 88%, 100%, 76% and 0.88 for recognition of O. hupensis robertsoni snail sample images, and there was no significant difference in the accuracy of recognition of O. hupensis robertsoni snail sample images between the AI-enabled intelligent snail identification system and artificial identification (χ2 = 0.204, P > 0.05). In addition, there was no significant difference in the accuracy of artificial identification for recognition of snail sample images with upward (90%) and downward shell openings (86%) (χ2 = 0.379, P > 0.05), and there was a significant difference in the accuracy of artificial identification for recognition of snail sample images between schistosomiasis control professionals with snail survey experiences of 6 years and less and more than 6 years (χ2 = 5.604, Padjusted < 0.025). Conclusions The accuracy of recognition of snail sample images is comparable between the AI-enabled intelligent snail identification system and artificial identification by schistosomiasis control professionals, and the AI-enabled intelligent snail identification system is feasible for recognition of O. hupensis robertsoni and Tricula in Yunnan Province.
2.Influence evaluation of pharmaceutical quality control on medication therapy management services by the ECHO model
Kun LIU ; Huanhuan JIANG ; Yushuang LI ; Yan HUANG ; Qianying ZHANG ; Dong CHEN ; Xiulin GU ; Jinhui FENG ; Zijian WANG ; Yunfei CHEN ; Yajuan QI ; Yanlei GE ; Aishuang FU
China Pharmacy 2025;36(9):1123-1128
OBJECTIVE To evaluate the influence of pharmaceutical quality control on the efficiency and outcomes of standardized medication therapy management (MTM) services for patients with coronary heart disease by using Economic, Clinical and Humanistic Outcomes (ECHO) model. METHODS This study collected case data of coronary heart disease patients who received MTM services during January-March 2023 (pre-quality control implementation group, n=96) and June-August 2023 (post-quality control implementation group, n=164). Using propensity score matching analysis, 80 patients were selected from each group. The study subsequently compared the economic, clinical, and humanistic outcome indicators of pharmaceutical services between the two matched groups. RESULTS There were no statistically significant differences in baseline data between the two groups after matching (P>0.05). Compared with pre-quality control implementation group, the daily treatment cost (16.26 yuan vs. 24.40 yuan, P<0.001), cost-effectiveness ratio [23.12 yuan/quality-adjusted life year (QALY) vs. 32.32 yuan/QALY, P<0.001], and the incidence of general adverse drug reactions (2.50% vs. 10.00%, P=0.049) of post-quality control implementation group were decreased significantly; the utility value of the EuroQol Five-Dimensional Questionnaire (0.74± 0.06 vs. 0.71±0.07, P=0.003), the reduction in the number of medication related problems (1.0 vs. 0.5, P<0.001), the medication adherence score ([ 6.32±0.48) points vs. (6.10±0.37) points, P=0.001], and the satisfaction score ([ 92.56±1.52) points vs. (91.95±1.56) points, P=0.013] all showed significant improvements. Neither group experienced serious adverse drug reactions. There was no statistically significant difference in the incidence of new adverse reactions between the two groups (1.25% vs. 3.75%, P=0.310). CONCLUSIONS Pharmaceutical quality control can improve the quality of pharmaceutical care, and the ECHO model can quantitatively evaluate the effect of MTM services, making pharmaceutical care better priced and more adaptable to social needs, thus being worthy of promotion.
3.Effects of GanoExtra combined with CTX on lung metastasis and immune function in mice
Shu LIAN ; Ting-Jian WU ; Jie CHEN ; Chun-Lian ZHONG ; Yu-Sheng LU ; Ye LI ; Chang-Hui WU ; Kun ZHANG ; Li JIA ; Xiao-Dong XIE
Chinese Pharmacological Bulletin 2024;40(7):1335-1342
Aim To investigate the enhanced efficacy and reduced toxicity of GanoExtra in combination with cyclophosphamide(CTX)on inhibiting lung metastasis and immune function in mice.Methods The CCK-8 method was used to verify the cytotoxic effects of Gano-Extra on MCF-7 and 4T1 tumor cells.In vivo experi-ment,a mouse model of lung metastasis of breast canc-er was established by injecting 4T1 tumor cells into the tail vein,which was divided into four groups including 4T1 model group,CTX group,GanoExtra group and GanoExtra+CTX group.The control group was set.After 21 days,the mice were euthanized under anes-thesia,and the body weight of the mice was recorded.Average lung index and spleen index were calculated.The mouse spleen lymphocyte transformation experi-ment was used to determine the activity of spleen cells.The NK cell activity assay was used to determine the activity of NK cells.Blood cells were determined in mouse blood samples.Flow cytometry was used to de-termine the levels of CD4+and CD8+T cells in blood samples.ELISA was used to measure the levels of TNF-α and IL-6 in serum.HE staining was used to ob-serve the pathological morphological changes in tumors and various tissues;and CFSE staining was used to de-termine the proliferative effect of GanoExtra on CD8+cells.Results In vitro GanoExtra at 50 mg·L-1 sig-nificantly inhibited the activity of MCF-7 and 4T1 tumor cells.In the breast cancer pulmonary metastasis model,compared with the model group,the spleen in-dex and blood WBCs content were significantly re-duced,while the activity of NK cells,spleen cells,and the proportion of RBCs,CD 3+and CD 8+T cells in the blood were significantly increased.At the end of the treatment,compared with the CTX group,the number of lung metastases and lung index of the Gano-Extra+CTX group were significantly reduced,and the levels of HGB,CD8+cells,IL-6,and TNF-α in the blood of mice were significantly increased.GanoExtra at 10 mg·L-1 significantly promoted the proliferation of CD8+T cells in vitro.Conclusions GanoExtra can enhance the inhibitory effect of CTX on tumor metasta-sis,alleviate adverse reactions such as splenomegaly and pulmonary enlargement caused by CTX,and have a health-promoting function of promoting the prolifera-tion of CD8+T cells to enhance the immune efficacy of the body.
4.Clinical observation of different intramedullary fixation methods for the treatment of intertrochanteric fracture
Li-Kun JIN ; Ye LI ; Jie ZHANG ; Yan-Xu DONG ; Yue-Feng QI
China Journal of Orthopaedics and Traumatology 2024;37(3):293-299
Objective To explore clinical efficacy of proximal femoral nail anti-rotation(PFNA),InterTan and proximal femoral bionic intramedullary nail(PFBN)in treating femoral intertrochanteric fracture.Methods Clinical data of 120 patients with intertrochanteric fracture who were underwent closed reduction intramedullary nail-internal fixation from January 2020 to January 2021 were retrospectively analyzed.According to methods of internal fixation,patients were divided into 3 groups.There were 25 patients in PFBN group,including 16 females and 9 males,aged from 69 to 79 years old with an average of(73.67±5.16)years old.There were 55 patients in PFNA group,including 38 females and 17 males,aged from 68 to 80 years old with an average of(74.23±5.57)years old.There were 40 patients in InterTan group,including 26 females and 14 males,aged from 68 to 79 years old with an average of(73.45±5.34)years old.Operative time,intraoperative blood loss,incision length,hospital stay,weight-bearing time,fracture healing time and complications among 3 groups were compared,and clinical effect was evaluated by Harris score of hip function before operation,1,6 and 12 months after opertaion,respectively.Results Patients among 3 groups were successfully completed operation and were followed up for more than 12 months.There were no significant difference in hospital stay,operative time,intraoperative blood loss and incision length among 3 groups(P>0.05).Weight bearing time of PFBN group(7.98±1.34)d and InterTan group(8.22±0.46)d were earlier than that of PFNA group(10.27±0.66)d(P<0.01).Fracture healing time of PFBN group(10.14±2.33)weeks and InterTan group(11.87±2.48)weeks were earlier than that of PFNA group(13.68±2.36)weeks(P<0.01).One month after operation,Harris score in PFBN group(70.52±5.34)and InterTan group(69.81±6.17)was higher than that of PFNA group(51.46±5.36),and there was no signifi-cant difference between PFBN group and InterTan group(f>0.05).There were no significant difference in Harris scores among 3 groups before operation,6 and 12 months after opertaion(P>0.05).Cases of complication of InterTan group and PFNA group were lower than that of PFNA group(P<0.05).Conclusion PFBN and InterTan for the treatment of intertrochanteric fracture have advantages of faster fracture healing,earlier weight-bearing time and fewer postoperative complications than traditional PFNA,but three operations could achieve higher effective rates without significant difference in long-term results.
5.AI-HIP system for prosthesis size,global femoral offset and osteotomy in total hip arthroplasty
Guo-Yuan SUN ; Yan-Kun JIANG ; Tong LI ; Xue-Feng CONG ; Cheng HUANG ; Ran DING ; Wei-Guo WANG ; Qi-Dong ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(9):848-854
Objective To explore planning effect of AI-HIP assisted surgical planning system in primary unilateral total hip arthroplasty(THA)and its influence on clinical outcomes.Methods A retrospective analysis was conducted on clinical data of 36 patients who underwent their first unilateral THA from March 2022 to November 2022 and continuously used AI-HIP system(AI-HIP group),including 16 males and 20 females,aged from 43 to 81 years old with an average of(62.2±10.9)years old.According to the matching principle,36 patients who were planned by the traditional template method at the same period were selected as the control group,including 16 males and 20 females,aged from 40 to 80 years old with an average of(60.9±12.1)years old.The accuracy between two groups of prostheses were compared,as well as the combined eccentricity difference between preoperative planning and postoperative practice,lower limb length difference,osteotomy height from the upper edge of the lesser trochanter and top shoulder distance to evaluate planning effect.Harris score and visual analogue scale(VAS)were used to evaluate clinical efficacy.Results Both groups were followed up for 12 to 18 months with an average of(14.5±2.1)months.The complete accuracy and approximate accuracy of acetabular cup and femoral stalk prosthesis in AI-HIP group were 72.2%,100%,58.3%,88.9%,respectively,which were better than 44.4%,83.3%,33.3%,66.7%in control group(P<0.05).There was no statistical significance in planning of femoral head prosthesis size(P>0.05).The actual combined eccentricity difference and combined eccentricity difference(practical-planning)in Al-HIP group were 1.0(0.2,2.4)mm and 1.1(-2.1,3.2)mm,respectively;which were better than 3.0(1.4,4.9)mm and 3.5(-1.6,6.5)mm in control group(P<0.05).There was no significant difference between two groups in actual osteotomy height of the upper margin of the lesser trochanter(P>0.05).In AI-HIP group,the actual difference of lower extremity length after surgery,the difference of lower extremity length(practical-planning),osteotomy height from the upper margin of lesser trochanter(practical-planning),actual topshoulder distance after surgery,and topshoulder distance(practical-planning)were 1.5(0.2,2.8),1.1(-0.3,2.2),2.1(-2.3,4.1),(15.3±4.1),2.2(-4.8,0.3)mm,respectively;which were better than control group of 2.6(1.3,4.1),2.5(0.3,3.8),5.8(-2.4,7.7),(13.0±4.3),-5.7(-9.4,-2.2)mm(P<0.05).At final follow-up,there were no significant differences in Harris scores of pain,function,deformity,total scores and VAS between two groups(P>0.05).The range of motion score was 4.8±0.6 in AI-HIP group,which was higher than that in control group(4.4±0.8)(P<0.05).Conclusion Compared with traditional template planning,AI-HIP assisted surgical planning system has good accuracy in predicting the prosthetic size of the acetabular cup and femoral stalk,restor-ing joint eccentricity,planning lower limb length,osteotomy height and top shoulder distance on the first unilateral THA,and the clinical follow-up effect is satisfactory.
6.Navigation and quantitative evaluation strategies for tumor fluorescent surgery based on arti-ficial intelligence and medical big data
Jie TIAN ; Kun WANG ; Di DONG ; Zhenyu LIU ; Zeyu ZHANG ; Mengjie FANG
Chinese Journal of Digestive Surgery 2024;23(4):536-542
The development of molecular imaging has been going on for more than 20 years. During this period, a large number of new imaging technologies for molecular imaging have been proposed, but only a small number of them have successfully achieved clinical transformation, entered the actual clinical application and achieved significant clinical results. Among them, intraoperative navigation based on fluorescence molecular imaging and quantitative analysis technology based on medical imaging big data are being carried out in more and more clinical trials and have gradually won wide recognition. Through the in-depth integration of these two technologies with artificial intelligence, a series of research results have been achieved in multiple clinical diagnosis and treat-ment processes such as preoperative diagnosis, intraoperative navigation and postoperative prediction of digestive system tumors, providing new technical support in the field of medical imaging for the individualized diagnosis and treatment of patients with digestive system diseases.
7.Dosimetric effect of calculation grid size on stereotactic body radiation therapy of lung cancer in helical tomotherapy planning system
Xia-Yu HANG ; Wan-Rong JIANG ; Yi-Kun LI ; Jun HU ; Yan ZHANG ; Ruo-Qi CAO ; Nan XU ; Lei WANG ; Jin-Da ZHOU ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(2):52-57
Objective To investigate the dosimetric effects of different calculation grid size(CGS)in helical tomotherapy(HT)planning system on stereotactic body radiation therapy(SBRT)for non-small cell lung cancer(NSCLC).Methods Nine NSCLC patients receiving radiation therapy for the first time at some hospital from March 2019 to December 2022 were selected as the subjects.SBRT planning was carried out through the HT system with three different CGS plans(Fine,Normal,and Coarse)and the same pitch,modulation factor(MF)and optimization conditions,and the target area indexes of the three CGS plans were compared including conformity index(CI),homogeneity index(HI),dosimetric parameters of the organ at risk(OAR),point dose verification pass rate,treatment time,number of monitor units and Sinograms.SPSS 22.0 was used for statistical analysis.Results For target area HI,there weres significant differences between CGS Fine plan and Coarse plan and between CGS Normal plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan(P>0.05).For target area CI,there were significant differences between CGS Fine plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan and between CGS Normal plan and Coarse plan(P>0.05).For OAR dosimetric parameters,CGS Fine plan and Coarse plan had significant differences in heart Dmax and Dmean,esophageal Dmax and Dmean,V5,V20,V30 and Dmean of the whole lung and affected lung,V5 and Dmax of the affected lung and heart V10 and V30(P<0.05),CGS Normal plan and Coarse plan had obvious differences in esophageal Dmax(P<0.05),and the remained dosimetric parameters were not statistically significant(P>0.05).Fine,Normal and Coarse plans had the point dose verifica-tion pass rates being 0.96%,1.50%and 1.77%,respectively.In terms of treatment time and number of monitor units,there were significant differences between Fine plan and Coarse plan(P<0.05)while no statistical differences were found between Fine and Normal plans and between Normal and Coarse plans(P>0.05).Sinograms analyses showed Fine plan had evenly distributed segment color gradient,Coarse plan had areas of very dark and very light color gradients and Normal plan was somewhere in between.Conclusion Low CGS has to be used as much as possible to obtain accurate dose distribution during SBRT planning for NSCLC patients,which contributes to the execution of the radiation therapy plan and the prevention of ad-verse effects.[Chinese Medical Equipment Journal,2024,45(2):52-57]
8.Dosimetric effect of jaw widths on stereotactic body radiotherapy for hepatocellular carcinoma
Xia-Yu HANG ; Yi-Kun LI ; Jun HU ; Ruo-Qi CAO ; Yan ZHANG ; Nan XU ; Xian-Qiang SONG ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(7):51-55
Objective To investigate the radiotherapy dose impacts of different jaw widths on stereotactic body radiotherapy(SBRT)for hepatocellular carcinoma(HCC)with the hilical tomotherapy(HT)planning system.Methods Totally 16 HCC patients who received radiotherapy at some hospital from March 2021 to August 2023 were selected,and the planning was carried out with the same pitch,modulation factors and optimization conditions and the jaw widths being 1.0,2.5 and 5.0 cm.The dosimetric differences due to the jaw widths in planned targets and organs at risk(OAR)were compared,and the planned treatment time,monitor unit,gantry rotations and gantry period were evaluated.SPSS 22.0 was used for statistical analysis.Results Better dosimetric parameters and lower doses to OARs could be got with lower jaw widths.The widened jaw widths resulted in reduced planned treatment time,decreased monitor units and gantry rotations,shortened gantry period while enhanced treatment efficiency.Conclusion A 2.5 cm jaw width for HT planning contributes to improving treatment efficiency during HCC SBRT under the premise of ensured target dose distribution and satisfactory dose to OAR for clinical require-ments.[Chinese Medical Equipment Journal,2024,45(7):51-55]
9.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
10.Role of reactive oxygen species/silent information regulator 1 in hyperoxia-induced bronchial epithelial cell injury
Kun YANG ; Yue WU ; Rong ZHANG ; Xiao-Ping LEI ; Lan KANG ; Wen-Bin DONG
Chinese Journal of Contemporary Pediatrics 2024;26(8):852-860
Objective To investigate the effect of reactive oxygen species(ROS)/silent information regulator 1(SIRT1)on hyperoxia-induced mitochondrial injury in BEAS-2B cells.Methods The experiment was divided into three parts.In the first part,cells were divided into H0,H6,H12,H24,and H48 groups.In the second part,cells were divided into control group,H48 group,H48 hyperoxia+SIRT1 inhibitor group(H48+EX 527 group),and H48 hyperoxia+SIRT1 agonist group(H48+SRT1720 group).In the third part,cells were divided into control group,48-hour hyperoxia+N-acetylcysteine group(H48+NAC group),and H48 group.The ROS kit was used to measure the level of ROS.Western blot and immunofluorescent staining were used to measure the expression levels of SIRT1 and mitochondria-related proteins.Transmission electron microscopy was used to observe the morphology of mitochondria.Results Compared with the H0 group,the H6,H12,H24,and H48 groups had a significantly increased fluorescence intensity of ROS(P<0.05),the H48 group had significant reductions in the expression levels of SIRT1 protein and mitochondria-related proteins(P<0.05),and the H24 and H48 groups had a significant reduction in the fluorescence intensity of mitochondria-related proteins(P<0.05).Compared with the H48 group,the H48+SRT1720 group had significant increases in the expression levels of mitochondria-related proteins and the mitochondrial aspect ratio(P<0.05),and the H48+EX 527 group had a significant reduction in the mitochondrial area(P<0.05).Compared with the H48 group,the H48+NAC group had a significantly decreased fluorescence intensity of ROS(P<0.05)and significantly increased levels of SIRT1 protein,mitochondria-related proteins,mitochondrial area,and mitochondrial aspect ratio(P<0.05).Conclusions The ROS/SIRT1 axis is involved in hyperoxia-induced mitochondrial injury in BEAS-2B cells.

Result Analysis
Print
Save
E-mail