1.Treatment Modalities and Long-Term Outcomes in Unruptured Vertebrobasilar Fusiform Aneurysms: A Nationwide Observational Cohort Study
Linggen DONG ; Dachao WEI ; Xiheng CHEN ; Mingtao LI ; Yang ZHAO ; Yong SUN ; Qingbin NIE ; Jun FENG ; Guomin XIAO ; Jinghua ZHOU ; Shengli HU ; Lifei FENG ; Lifeng QI ; Hongen LIU ; Geng GUO ; Yufang LI ; Renfu TIAN ; Jianghua YU ; Dianshi JIN ; Liang HAO ; Tian TIAN ; Shizhong ZHANG ; Yang WANG ; Liping LIU ; Ming LV
Journal of Stroke 2026;28(2):250-262
Background:
and Purpose Vertebrobasilar fusiform aneurysms (VBFAs) carry substantial morbidity and mortality, but optimal management for unruptured VBFAs remains unclear. We compared the safety and efficacy of conservative management (CM), stent-assisted coiling (SAC), and flow diverters (FDs) in patients with unruptured VBFAs, focusing on long-term prognosis.
Methods:
This study included data from a nationwide Chinese cohort of patients with vertebrobasilar dissecting aneurysms. Inverse probability of treatment weighting (IPTW) balanced confounders across groups. The primary outcome was poor prognosis (modified Rankin Scale score >2). Secondary outcomes included aneurysm rupture, ischemic stroke, compression symptoms, and VBFA-related deaths. Logistic regression estimated odds ratios (ORs) and 95% confidence intervals (CIs). Subgroup and sensitivity analyses were performed.
Results:
Among 1,115 patients with unruptured VBFAs, 838 (median age, 54 years; 655 men) were included. After IPTW, baseline characteristics were balanced. Median follow-up was 54 months. FD was associated with a lower risk of poor prognosis than CM (OR, 0.48 [95% CI, 0.30 to 0.77]; p=0.002), with no difference between CM and SAC. FD also reduced aneurysm rupture (OR, 0.20 [95% CI, 0.07 to 0.60]; p=0.004) and compression symptoms (OR, 0.30 [95% CI, 0.13 to 0.68]; p=0.004) versus CM. Time-to-event analyses further revealed significant differences in vertebral artery lesions and Type I–II VBFAs, whereas no significant differences were observed in basilar or vertebrobasilar junction lesions or in Type III–IV VBFAs.
Conclusions
Compared with CM, FD was associated with improved long-term outcomes in unruptured VBFAs, particularly in vertebral artery lesions and Type I–II VBFAs, although residual confounding cannot be excluded.
2.Differences in deltamethrin resistance and kdr gene mutation in Culex tritaeniorhynchus population in and outside the Yellow Sea wetland
Xiao-er ZHANG ; Zhi-ming WU ; Ye TIAN ; Qian CUI ; Yu-qian JI ; Huan WANG ; Shu-juan YANG ; Yi-chao ZHAO ; Yu WANG ; Hua-yu YIN ; Yu DING ; Guo-jin YAN ; Min-sen ZHAO ; Shou-gang ZHANG ; Bing-dong SONG ; Hong-na CHEN ; Jian GAO ; Wei-fang YANG ; Yu-fu ZHANG ; Hui LIU ; Hong-liang CHU
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):101-107
Objective To gain insights into the biological characteristics of different populations of Culex tritaeniorhynchus within and around the Yellow Sea wetland from the perspective of the occurrence of resistance, we investigated the levels of resistance to deltamethrin and kdr gene mutation in the wetland and its peripheral areas. Methods Specimens were collected from Cx. tritaeniorhynchus populations at two monitoring sites in the Rare Bird National Nature Reserve and Tiaozi Ni Wetland Scenic Area, and also from two populations in Yancheng City and the Liuhe District of Nanjing, and the resistance of these mosquitoes to deltamethrin was determined using the CDC biotest bottle method. For each concentration of deltamethrin assessed, a random subset of exposed specimens was selected for amplification of the kdr gene fragment, followed by Sanger sequencing to identify and analyze resistance-associated mutations. Results The LC50 levels of deltamethrin among mosquitoes from the four populations in Luhe, Yancheng, the Rare Bird National Nature Reserve and the Tiaozi Ni Wetland Scenic Area were 2.048 5, 7.798 2, 3.473 3, and 17.695 5 mg/mL, respectively, with corresponding concentrations of deltamethrin ranging from 0.005 to 5.000,0.050 to 50.000,0.050 to 25.000 and 0.050 to 50.000 mg/mL, respectively. Furthermore, the ranges of the KT50 values were 11.76-107.43, 67.05-216.30,29.77-107.43 and 28.40-329.51 min; the 1-h knockdown rates were 34.58%-99.15%, 9.52%-43.80%, 55.09%-73.01%, and 10.09%-68.07%; and the 24-h mortality rates were 12.15%-67.52%,9.52%-79.56%,13.17%-82.21%, and 11.01%-78.99%, respectively. With respect to kdr gene mutation, we assayed a total of 63,70,59, and 57 mosquitoes for the four populations, for which we detected L1014F mutation frequencies of 14.29%, 35.00%, 20.34%, and 31.58%, respectively, with a majority of these mutations being heterozygous for resistance. In addition, five adult mosquitoes were identified has having synonymous mutations at site 1011[i. e. , AAT(asparagine)mutation to AAC(asparagine)]. Conclusions Our findings revealed the clear resistance of Cx. tritaeniorhynchus to deltamethrin in the Yancheng region of the Yellow Sea wetland, and the resistance phenotype and kdr frequency of Cx. tritaeniorhynchus in the wetland environment were comparable to those of Cx. tritaeniorhynchus in the wetland environment, thereby indicating that the resistance of different populations of Cx. tritaeniorhynchus was homogeneous under the pressure of different insecticide selection within and around the wetland. However, the underlying mechanisms need to be further studied.
3.Discussion on precautions for the detection of nitrogen oxides in workplace air
Zhanhong YANG ; Weifeng RONG ; Banghua WU ; Ming DONG ; Xueji YANG ; Chuan WU
China Occupational Medicine 2025;52(4):450-454
Objective To summarize the key precautions in the determination of nitrogen oxides (nitric oxide and nitrogen dioxide) in the workplace air and to explore potential optimization items in the national standard analytical method. Methods According to GBZ/T 160.29-2004 Methods for Determination of Inorganic Nitrogen Compounds in the Air Workplace, comparative experiments were conducted to evaluate and optimize critical technical parameters of the standardized method, including the oxidation efficiency of oxidation tubes and the preparation and storage of absorption solutions. The application details of the standard method were refined. Results The concentrations of nitrogen oxides (nitric oxide and nitrogen dioxide) were expressed as nitrogen dioxide equivalents. During calibration, the flow calibrator should be connected to the upstream of the air sampler, and the sampling system should undergo an air tightness check. Each batch of oxidation tubes should be validated before use. Before sampling, both end caps should be removed and the tube should be equilibrated for one hour in a clean environment with 30.00%-70.00% relative humidity. The prepared absorption stock solution in this method can be stored at 4 ℃ for up to 96 days. Commercial porous plate absorption tubes must be batch-validated before use. The sampling flow rate during sampling should be consistent with that specified in the standard method. After sampling, collected samples should be sealed in 10.00 mL amber glass bottles with screw caps and stored at 4 ℃ for up to 120 hours. Conclusion This study summarizes precautions for the sampling, detection, and calculation of nitrogen oxides (nitric oxide and nitrogen dioxide)in workplace air to strengthen quality control. Experimental optimizations of oxidation tube conditioning, absorption stock solution preparation and preservation, and sample storage conditions and durations may provide references for diversifying and simplifying the detection process, which facilitate the practical application in actual work.
4.Typical failure treatment of large-aperture 16-slice spiral Siemens SOMATOM Sensation Open CT
Yu-kun ZHU ; Shi-dong CHENG ; Ming YANG ; Fei WENG ; Jing TIAN ; Chen LIANG
Chinese Medical Equipment Journal 2025;46(11):112-114
Three typical failures of large-aperture 16-slice spiral Siemens SOMATOM Sensation Open CT were introduced in terms of phenomenon,cause and treatment method.References were provided for medical engineers to treat similar failures.
5.Distalfemur rotational alignment in knee osteoarthritis patients by three-dimensional computed tomography
Bo YANG ; Xianghui HUANG ; Xianghui DONG ; Hui QIANG ; Shizhang LIU ; Pengzhen LEI ; Ming CHEN
Journal of Xi'an Jiaotong University(Medical Sciences) 2025;46(6):991-995
Objective To explore the gender differences and the influence of varus and valgus deformities on distal femur rotational alignment in patients with knee osteoarthritis so as to provide reference for the distal femur rotational osteotomy in total knee arthroplasty(TKA).Methods CT data of 125 knees with osteoarthritis suitable for TKA(including 56 males and 69 females;78 varus knees and 47 valgus knees)were collected and received three-dimensional imaging reconstruction with Mimics software.We measured the posterior condylar angle(PCA),the angle between the anteroposterior axis and the surgical epicondylar axis(ASA),and the angle between the anteroposterior axis and the posterior condylar axis(APA).We also compared gender differences and the influences of varus-valgus deformities on distal femur rotational alignments.Results The PCA and ASA values of distal femur rotational alignments were(3.5±1.1)° vs.(2.8±1.2)°(P=0.001)and(90.6±3.4)° vs.(91.9±3.5)°(P=0.028)for males and females,with statistically differences between the genders.There was no statistically difference in APA between males and females(P=0.482).The PCA values of distal femur rotational alignment in varus and valgus knees were(3.6±1.1)° and(2.9±1.2)°,with a statistically difference between the two groups(P=0.001).There were no statistically differences in ASA or APA between varus and valgus knees(P>0.05).Conclusion Gender and varus-valgus deformities of knee joint affect the distal femur rotational alignment.Distal femur rotational osteotomy angle should be determined according to the patient's CT imaging before TKA to reduce the errors caused by individual differences and improve the accuracy of the distal femur rotational alignment during TKA.
6.Design, synthesis, and antitumor activity of novel thioheterocyclic nucleoside derivatives by suppressing the c-MYC pathway.
Xian-Jia LI ; Ke-Xin HUANG ; Ke-Xin WANG ; Ru LIU ; Dong-Chao WANG ; Yu-Ru LIANG ; Er-Jun HAO ; Yang WANG ; Hai-Ming GUO
Acta Pharmaceutica Sinica B 2025;15(7):3685-3707
Eightly-four novel thioheterocyclic nucleoside derivatives were designed, synthesized, and evaluated for antitumor activity in vitro and in vivo. Most of the compounds inhibited the growth of HCT116 and HeLa cancer cells in vitro, among them 33a and 36b exhibited potent activity against HCT116 cells (IC50 = 0.27 and 0.49 μmol/L, respectively). Both compounds 33a and 36b inhibited cell metastasis, arrested the cell cycle in the G2/M phase, and induced apoptosis in vitro. Mechanistic studies revealed that 33a and 36b increased ROS levels, led to DNA damage, ER stress, and mitochondrial dysfunction, and inhibited autophagy in HCT116 cells. Biological information analysis, RNA-sequencing, Gene Set Enrichment Analysis (GSEA), drug affinity responsive target stability (DARTS) assay, cellular thermal shift assay (CETSA), and SPR experiments identified that compounds 33a and 36b showed antitumor activity by suppressing the c-MYC pathway. c-MYC silencing assays indicated that c-MYC proteins participated in 33a-mediated anticancer activities in HCT116 cells. More importantly, compound 33a presented favorable pharmacokinetic properties in mice (T 1/2 = 6.8 h) and showed significant antitumor efficacy in vivo without obvious toxicity, showing promising potential for further clinical development.
7.Novel Structural Features of Isoflavone Synthase from Medicago truncatula Shed Light on Its Unique Enzymatic Mechanism
Chao SHI ; Zhao-Yang YE ; Fei XU ; Xiang-Ning DU ; Zhang-Xin CHEN ; Ming-Yue GU ; Jie DENG ; Wei WANG ; Liang-Yu LIU ; Mei-Ying WANG ; Xiao-Dong SU ; He-Li LIU ; Ming-Ying SHANG ; Li-Xin HUANG ; Zhen-Zhan CHANG
Chinese Journal of Biochemistry and Molecular Biology 2025;41(8):1204-1213,中插1-中插6
Isoflavones which mainly distributed in leguminous plants have plenty of health benefits.Isoflavone synthase(IFS)is a membrane-associated cytochrome P450 enzyme(CYP450)which carries out the unique aryl-ring migration and hydroxylation.So far,few crystal structures of plant P450s have been obtained.We determined the crystal structure of IFS from Medicago truncatula at 1.9 ? by MAD method using a selenomethionine substituted crystal and conducted molecular docking and mutagenesis study.The structure of IFS complexed with imidazole exhibits the helix Ⅰa-loop-helix Ⅰβ motif which cor-responds to helix Ⅰ of other P450s.Compared with structures of common P450s,IFS/imidazole structure contains an extra domain,i.e.,the γ-domain.The structure reveals a homodimer in which the γ-domain of one molecule interacts with the β-domain of another.The plane of heme group makes an angle of ap-proximately 40° with the helix Ⅰa-loop-helix Ⅰβ motif.Molecular docking combined with mutagenesis study suggested that Trp-128 and Asp-300 might play important roles in substrate binding and recogni-tion.Phe-301,Ser-303 and Gly-305 from the helix Ⅰa-loop-helix Ⅰβ motif may play important roles in the aryl-ring migration.These novel structural features reveal insights into the unique reaction mechanism of IFS and provide a basis for engineering IFS in leguminous crops for health purpose.
8.Current research on ankle prosthetics and joint replacement for Kashin-Beck disease
Hu ZHAO ; Ming LING ; Cuixiang XU ; Xiaoli YANG ; Xianghui DONG ; Zhankui JIN
Chinese Journal of Endemiology 2025;44(6):512-516
Kashin-Beck disease (KBD), a common joint disorder that can lead to joint deformities and restricted mobility, significantly affects patients' quality of life. Traditional conservative treatments have shown limited efficacy. With advancements in total ankle replacement prosthesis and the successive updates of mobile and fixed -bearing in ankle prosthesis, more and more clinical trial results indicate that ankle prosthesis replacement is expected to become a new approach for treating KBD. This article reviews the progress in ankle prosthesis and studies their clinical application potential in KBD management.
9.Influence of different disinfectants on ultrasound-guided internal jugular vein puncture and adhesive application
Jin-zhu MA ; Hai-yan GAO ; Hao WANG ; Ming-lan YANG ; Chun-hui HU ; Dong-liang WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(2):147-150
Objective To investigate the influence of different disinfectants on the ultrasound-guided internal jugular vein puncture and adhesive application.Methods A total of 102 emergency patients with traumatic hemorrhage who underwent ultrasound-guided internal jugular vein puncture and catheterization were selected as the study subjects and randomly divided into the iodine group(51 cases)and the chlorhexidine-alcohol group(51 cases).Iodophor(0.5%effective iodine)and 2.0%chlorhexidine gluconate+70.0%ethanol were used for disinfection before puncture,respectively.The disinfection effect of the puncture site,puncture condition,ultrasound imaging,and adhesive force of the application of patients were statistically compared between the two groups.Results There was no significant difference in the bacterial count before disinfection,the bacterial count after disinfection or the qualified rate of disinfection at the puncture site of patients between the two groups(P>0.05).There were significant differences in the success rate of one-time puncture,the number of puncture and the time of puncture and catheterization between the two groups(P<0.05).There were significant differences in the rate of clear ultrasound images,adhesive force and rate of warping or shedding of the application between the two groups(P<0.05).Conclusion For emergency patients with traumatic hemorrhage,using iodophor(0.5%effective iodine)and 2.0%chlorhexidine gluconate+70.0%ethanol disinfection before ultrasound-guided internal jugular vein puncture can achieve good disinfection effects.Iodine disinfection can obtain clearer ultrasound images and a higher success rate of one-time puncture,but the adhesive force of the application is poor,making it prone to warping or shedding.
10.Effect of miR-129-3p mimetic on bone loss in tail-suspended mice
Yi WU ; Zi-dong AN ; Yong-jie PANG ; Li-qiang WANG ; Xin-yang WANG ; Yu-hai GAO ; Xue-yan LI ; Ke-ming CHEN
Chinese Pharmacological Bulletin 2025;41(4):703-709
Aim To study whether intravenous injec-tion of miR-129-3p mimetic(agomir)can resist bone loss caused by hind limb disuse,and to provide new i-deas for preventing bone loss in microgravity environ-ment.Methods Forty-eight C57BL/6J male mice were randomly divided into the control group(CON),tail suspension model group(TS),tail suspension+miR-129-3p agomir administration group(miRNA)and tail suspension+miR-129-3p negative sequence agomir control group(NC).The miRNA group was given 4 mg·kg-1 miR-129-3p agomir by intravenous injection into the medial canthus twice a week.The NC agomir group were consistent with those in the miR-129-3p agomir group,and the CON and TS groups were given only equal volumes of normal saline.After four weeks,all mice were sacrificed and samples were collected.Micro-CT scan of femur,three-point femur bending test,serum bone metabolism index detection,oxidative stress index detection and osteogenesis-related protein expression analysis in bone tissue were per-formed.Results After four weeks,the number of tra-becular bone in the TS group was significantly re-duced,and Tb.BMD,Tb.Th,Tb.N,Tb.BS/TV and Tb.BV/TV were significantly lower than those in the CON group(P<0.01).While Tb.Sp TS group was significantly higher than the CON group(P<0.05),the maximum load and flexural strength of the femur significantly decreased(P<0.01),the content of ser-um bone formation index PINP was significantly lower than that of the CON group(P<0.01),and the con-tent of bone resorption index CTX-I was significantly higher than that of the CON group(P<0.01),the content of serum oxidative damage indexes 8-iso-PGF2α and 8-OHdG significantly increased(P<0.01),and the expression of osteogenesis-related pro-teins in bone tissue markedly decreased(P<0.01).However,the increase or decrease of all indexes in miRNA group was significantly lower than that in TS group.Conclusions miR-129-3p mimetic can signifi-cantly reduce bone loss caused by hind limb disuse.This experiment provides a new idea and method for preventing bone loss in microgravity environment.


Result Analysis
Print
Save
E-mail