1.Subxiphoid uniportal approach using double sternum retractors versus subxiphoid and subcostal arch three-portal approach of video-assisted thoracoscopic surgery thymectomy for thymoma treatment: A retrospective cohort study
Jinlan ZHAO ; Weiyang CHEN ; Lin LIN ; Lei WANG ; Jie LI ; Lin MA ; Longqi CHEN ; Hong CHEN ; Dong TIAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(04):482-487
Objective To compare the efficacy and safety of video-assisted thoracoscopic surgery (VATS) thymectomy for the treatment of thymoma through subxiphoid uniportal approach using double sternum retractors, and subxiphoid and subcostal arch approach. Methods We retrospectively analyzed the clinical data of the patients diagnosed with thymoma who underwent VATS thymectomy from June 2023 to June 2024 in West China Hospital. Patients were categorized based on the surgical approach into two groups: a subxiphoid uniportal VATS thymectomy (SUVT) group and a subxiphoid and subcostal arch VATS thymectomy (SASAT) group. Comparisons were made between the two groups regarding surgical duration, intraoperative blood loss, postoperative drainage, thymoma size and location, and postoperative pain assessed using the visual analogue scale (VAS). Results The SUVT group consisted of 20 patients, including 11 males and 9 females, with an average age of (51.5±14.3) years. The SASAT group comprised 40 patients, including 26 males and 14 females, with an average age of (50.0±13.0) years. Compared to the SASAT group, the SUVT group had significantly larger thymomas [ (5.9±2.7) cm vs. (4.2±2.1) cm, P=0.010] and a higher proportion of neoplasms located in the superior mediastinum (30.0% vs. 2.5%, P=0.007). Additionally, the VAS pain scores on postoperative days 3, 7, and 30 were significantly lower in the SUVT group compared to the SASAT group (P<0.05). There were no statistical differences between the two groups in demographic characteristics, operative time, intraoperative blood loss, duration and volume of postoperative drainage, length of postoperative hospital stay, or the VAS pain score on the first postoperative day. Conclusion SUVT using double sternum retractors significantly reduces postoperative pain and provides superior efficacy in the resection of larger thymomas or those situated in the superior mediastinum.
3.Clinical trial of Morinda officinalis oligosaccharides in the continuation treatment of adults with mild and moderate depression
Shu-Zhe ZHOU ; Zu-Cheng HAN ; Xiu-Zhen WANG ; Yan-Qing CHEN ; Ya-Ling HU ; Xue-Qin YU ; Bin-Hong WANG ; Guo-Zhen FAN ; Hong SANG ; Ying HAI ; Zhi-Jie JIA ; Zhan-Min WANG ; Yan WEI ; Jian-Guo ZHU ; Xue-Qin SONG ; Zhi-Dong LIU ; Li KUANG ; Hong-Ming WANG ; Feng TIAN ; Yu-Xin LI ; Ling ZHANG ; Hai LIN ; Bin WU ; Chao-Ying WANG ; Chang LIU ; Jia-Fan SUN ; Shao-Xiao YAN ; Jun LIU ; Shou-Fu XIE ; Mao-Sheng FANG ; Wei-Feng MI ; Hong-Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(6):815-819
Objective To observe the efficacy and safety of Morinda officinalis oligosaccharides in the continuation treatment of mild and moderate depression.Methods An open,single-arm,multi-center design was adopted in our study.Adult patients with mild and moderate depression who had received acute treatment of Morinda officinalis oligosaccharides were enrolled and continue to receive Morinda officinalis oligosaccharides capsules for 24 weeks,the dose remained unchanged during continuation treatment.The remission rate,recurrence rate,recurrence time,and the change from baseline to endpoint of Hamilton Depression Scale(HAMD),Hamilton Anxiety Scale(HAMA),Clinical Global Impression-Severity(CGI-S)and Arizona Sexual Experience Scale(ASEX)were evaluated.The incidence of treatment-related adverse events was reported.Results The scores of HAMD-17 at baseline and after treatment were 6.60±1.87 and 5.85±4.18,scores of HAMA were 6.36±3.02 and 4.93±3.09,scores of CGI-S were 1.49±0.56 and 1.29±0.81,scores of ASEX were 15.92±4.72 and 15.57±5.26,with significant difference(P<0.05).After continuation treatment,the remission rate was 54.59%(202 cases/370 cases),and the recurrence rate was 6.49%(24 cases/370 cases),the recurrence time was(64.67±42.47)days.The incidence of treatment-related adverse events was 15.35%(64 cases/417 cases).Conclusion Morinda officinalis oligosaccharides capsules can be effectively used for the continuation treatment of mild and moderate depression,and are well tolerated and safe.
4.Protective effect and mechanism of ganoderma lucidum polysaccharide peptide on oxidative damage in diabetic nephropathy mice
Dan-Rong JIANG ; Dong-Mei LIN ; Lian-Fu WANG ; Yu-Hong YOU
The Chinese Journal of Clinical Pharmacology 2024;40(13):1918-1922
Objective To investigate the effects of ganoderma lucidum polysaccharide peptide(GLPP)on renal function and oxidative damage in diabetic nephropathy mice and its mechanism.Methods C57 mice were randomly divided into normal group,model group,positive control group(10.0 mg·kg-1 losartan),experimental-L group(50 mg·kg-1 GLPP),experimental-M group(100 mg·kg-1 GLPP),experimental-H group(200 mg·kg-1 GLPP)and GLPP+Losartan group(200 mg·kg-1 GLPP+10.0 mg·kg-1 losartan).Each group had 10 mice.After 8 weeks of continuous gastric administration,blood glucose was detected;renal function and lipid metabolism related indexes were detected by biochemical analyzer;serum inflammatory factor expression was detected by enzyme linked immunosorbent assay(ELISA);protein expression was detected by Western blot;oxidative damage related indexes were detected by kit method;apoptosis was detected by Tunel method.Results The fasting blood glucose of mice in normal group,model group,positive control group,experimental-H group and GLPP+Losartan group were(4.69±0.16),(20.31±2.04),(10.22±0.98),(10.26±0.96)and(7.76±0.43)mmol·L-1;serum creatinine(Scr)level were(25.48±2.33),(68.34±4.78),(32.93±3.25),(36.37±2.36)and(28.30±1.19)μmol·L-1,respectively;malonaldehyde(MDA)content were(2.05±0.22),(6.71±0.57),(2.69±0.27),(3.21±0.32)and(2.19±0.11)nmol·L-1,respectively;Tunel positive cell rates were(3.39±0.27)%,(26.75±1.24)%,(6.81±0.71)%,(8.05±0.80)%,(5.33±0.33)%,respectively;nuclear factor kappa B(NF-κB p65)protein expression levels were 0.31±0.05,1.07±0.08,0.40±0.03,0.47±0.04 and 0.35±0.03,respectively.The model group compared with the normal group for the above indicators,the experimental-H group compared with the model group for the above indicators,and the GLPP+Losartan group was compared with the experimental-H group for the above indicators,all differences were statistically significant in statistics(all P<0.05).Conclusion Ganoderma lucidum polysaccharide peptide may regulate Toll-like receptor 4/NF-κB pathway to inhibit apoptosis and inflammatory response,and improve oxidative damage in diabetic nephropathy mice.
5.Significance and Approach of Increasing Drug Loading in Solid Preparation of Traditional Chinese Medicine
Yuxuan DONG ; Yan WANG ; Yanlong HONG ; Xiao LIN ; Jiechen XIAN ; Lijie ZHAO ; Fei WU ; Youjie WANG
Chinese Journal of Modern Applied Pharmacy 2024;41(3):420-427
Drug loading is an important index to evaluate the quality of solid preparation of traditional Chinese medicine. Drug loading is restricted by drug characteristics, dosage form, process, and drug delivery in vivo, which affects the preparation process, therapeutic effect, and drug release rate. By consulting domestic and foreign literature, this paper put forward the significance of increasing the drug loading: improving the compliance of patients, reducing the production cost, reducing the risk of the excipients. In this review, the possible approaches to increase drug loading, such as the selection of high-efficiency excipients, suitable drug preparation techniques, and modification of the physical properties of drugs are summarized. It will provide theoretical basis through this review for the development of high drug loading and high-quality formulations.
6.Diagnostic quality for imported malaria in Hubei Province in 2019 - 2022
Jia YI ; Xiaorong DONG ; Zhen TU ; Lingcong SUN ; Cong ZHANG ; Wen LIN ; Hong ZHU
Journal of Public Health and Preventive Medicine 2024;35(3):46-49
Objective To analyze the diagnostic quality of imported malaria in Hubei Province from 2019 to 2022, and to further improve the diagnostic level and consolidate the achievements in eliminating malaria. Methods The samples of reported malaria cases in Hubei were collected by the provincial reference laboratory (PRL) from 2019 to 2022. The microscopy and fluorescent PCR were performed to confirm the infection of plasmodium species of each case.The positive coincidence rate and species coincidence rate were analyzed and compared. Results A total of 257 imported malaria cases were reported in Hubei Province from 2019 to 2022. Among 229 malaria cases were confirmed, the overall coincidence for malaria diagnosis was 91.24% (229/251), and the overall coincidence rate for parasite species identification was 86.03% (197/229). The difference in species coincidence rate among different years was statistically significant (χ2=10.458, P<0.05). The coincidence rates of malaria diagnosis and parasite species identification in different cities (prefectures) of Hubei Province were 71.43% to 100.00% and 50.00% to 100.00%, respectively, with significant differences among different regions (χ2=29.283, P<0.05). The coincidence rates of malaria diagnosis and parasite species identification were 72.73% to 100.00% and 0.00% to 100.00% in different diagnostic institutions, and the coincidence rate of species identification in hospitals (87.61%) was higher than that in Centers for Disease Control institutions (54.55%) (χ2=81.275, P<0.05). The coincidence rates of Plasmodium falciparum, P. vivax, P. malariae, and P. ovale identification were 91.50%, 88.57%, 80.00%, and 58.06%, respectively (χ2=19.777, P<0.05). Conclusion The quality of the qualitative diagnosis of malaria cases reported online from 2019 to 2022 is generally high. However, the ability of Plasmodium typing needs to be improved. In the future, technical training and quality control should be strengthened to improve the malaria surveillance capability during the post-elimination stage.
7.Effect of printing orientation on physical and mechanical properties of 3D printing prosthodontic base resin materials
Xinxin ZHAN ; Lulu CAO ; Dong XIANG ; Hao TANG ; Dandan XIA ; Hong LIN
Journal of Peking University(Health Sciences) 2024;56(2):345-351
Objective:To analyze the influence of forming direction on the surface characteristics,elastic modulus,bending strength and fracture toughness of printed parts and the relationship between forming direction and force direction,and to provide scientific basis and guidance for the clinical applica-tion of oral denture base resin materials.Methods:The 3D printing technology was used to print denture base resin samples.The shape and size of the samples referred to the current standard for testing conven-tional denture base materials.The samples used for physical performance testing were cylindrical(with a diameter of 15 mm and a thickness of 1 mm)and printed at different angles along the Z axis(0°,45°,90°).Scanning electron microscope was used to observe the microscopic topography of the different sam-ples.The color stability of different samples was observed by color stabilizer.The surface roughness of the samples was analyzed by using surface roughness tester.The Vickers hardness was measured to ana-lyze the hardness of the samples.The samples used for mechanical performance testing were rectangular(elastic modulus and bending strength:A length of 64 mm,a width of 10 mm,and a height of 3.3 mm;fracture toughness:A length of 39 mm,a width of 8 mm,and a height of 4 mm),divided into two groups:W group and H group.The W group was printed from the bottom up along the Z axis with the length × width as the bottom surface parallel to the X,Y axis plane,while the H group printed from the bottom up along the Z axis with the length × height as the bottom surface parallel to the X,Y axis plane.The forming angles of both groups were equally divided into 0°,45°,and 90°.The elastic modulus,bending strength and fracture toughness of different samples were studied through universal mechanical testing machine.SPSS 22.0 software was used for statistical analysis.Results:The microscopic topogra-phy and roughness of different samples were closely related to the printing direction,with significant differences between the 0°,45°,and 90° specimens.The 0° specimens had the smoothest surface(roughness<1 μm).The surface of the 45 ° specimen was the roughest(roughness>3 μm).The microhardness of the 0° sample was the best[(196.13±0.20)MPa],with a significant difference com-pared with the 90° sample[(186.62±4.81)MPa,P<0.05].The mechanical properties of different samples were also closely related to the printing direction.The elastic modulus,bending strength,and fracture toughness of the 45° samples in the W group were the highest compared with the other groups.The results of elastic modulus showed that in the H group,the 45° specimens had the highest elastic mo-dulus,which was significantly different from the 0° and 90° specimens(P<0.05).The elastic modulus of 0° and 45° specimens in the W group were higher than those in 90° specimens(P<0.05).The bending strength results showed that there was no significant difference between the specimens from dif-ferent angles in the H group.The bending strength of the 90° specimens in the W group was the smallest,and there was a significant difference between 90° and the 0° and 45° specimens(P<0.05);And the bendind strength of the 0° and 45° specimens in the W group was significantly higher than that of the 0° and 45° specimens in the H group(P<0.05).The fracture toughness results showed that the fracture toughness of the H group specimens was lower than 1.9 MPa m1/2,which was specified in the denture base standard.The 45° samples in the W group were the highest,with significant differences compared with the 0° and 90° samples(P<0.05).And the 90° samples of the W group specimens were lower than 1.9 MPa m1/2.And the fracture toughness of the 45° specimen in the W group was significantly higher than that of all the specimens in the H group(P<0.05).Conclusion:The 0° samples had rela-tively better physical properties.The 45° samples had the best mechanical properties.But the fracture toughness of specimens(H group and 90° samples of W group)did not yet meet clinical requirements.That indicated that the characteristics of the 3D printing denture base resin were affected by the printing direction.Only when the performance of the printed samples in all directions met the minimum require-ments of the standard,they could be used in clinical practice.
8.Development of Digital Polymerase Chain Reaction Technology and Its Progress in Disease Detection
Xu-Dong BAO ; Xiao-Lin HU ; Qi-Wu WAN ; Hong ZHANG ; Yang LUO
Chinese Journal of Analytical Chemistry 2024;52(1):13-21
Digital polymerase chain reaction(dPCR)is a PCR technology that realizes accurate quantification of single-copy nucleic acid molecules by dividing the reaction system into tens of thousands of independent PCR reaction units for single-molecule-level amplification and integrating Poisson distribution.Due to its single-copy sensitivity and accurate quantification without the need of standard curves,dPCR has been widely used in disease diagnosis.By introducing technologies such as stepped emulsification and three-dimensional imaging,dPCR has been greatly improved in terms of accuracy,multiplexability and turnaround time,significantly enhancing its performance in clinical disease diagnosis.Based on this,this paper traced the technological development history of dPCR,gave an overview of its application in detection of tumors,infections and other diseases,and further discussed the challenges and opportunities of the development of dPCR,with the aim of providing a reference for the development and utilization of dPCR in the future,and promoting the high-quality development of molecular technology in clinical testing.
9.The Application in The Development of Immunoassay Based on Upconversion Nanomaterials
Hui-Wei HUANG ; Li-Hua LI ; Lin LUO ; Yu-Dong SHEN ; Hong-Tao LEI ; Zhen-Lin XU
Progress in Biochemistry and Biophysics 2024;51(2):355-368
Immunoassays are widely used in medicine, food, environment and other fields due to having the advantages of simpleness, rapidness and accuracy. Combining immunoassays with nanomaterials can improve the performance of immunoassays. Compared with traditional nanomaterials, upconversion nanoparticles (UCNPs) have excellent optical properties such as good photostability, long luminescence lifetime and narrow and tunable emission bands, which can significantly reduce background noise and improve analytical sensitivity when combined with immunoassay. This paper briefly introduces the luminescence mechanism of UCNPs, summarizes the synthesis and surface modification methods of UCNPs. And then 5 UCNPs-based immunoassay techniques, namely, fluorescence resonance energy transfer, inner filter effect, magnetic separation technique, upconversion-linked immunosorbent assay and upconversion immunochromatography, are discussed in detail. These sensing protocols of UCNPs-based immunoassays have been successfully utilized to detect various targets, including small molecules, macromolecules, and pathogens, all of which closely related to food safety, human health, and environmental pollution. Finally, the challenges and prospects of this technique are summarized and prospected. Although the UCNPs immunoassays based on antibodies and antigens have made great progress, most of the research is still in the stage of laboratory, and there is a long way to go to realize its social applications. There is a series of challenges need to be overcome. (1) Designing excellent water soluble and dispersive upconversion nanomaterials is needed. Hydrophilic ligands are bound to smaller upconversion nanoparticles and removing hydrophobic surface ligands are the most widely used methods to improve solubility and dispersity. (2) Multi-detection technology platforms and multi-mode simultaneous detection platforms have great potential, which will improve the efficiency of point of care detection. (3) The researchers also need to focus on some important problems. For examples, the upconversion luminescence efficiency of UCNPs is difficult to maintain, the synthesis method is complex, and the surface modification degree and functionalization are difficult to control.
10.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.


Result Analysis
Print
Save
E-mail