1.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
2.Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults (version 2025)
Bobin MI ; Faqi CAO ; Weixian HU ; Wu ZHOU ; Chenchen YAN ; Hui LI ; Yun SUN ; Yuan XIONG ; Jinmi ZHAO ; Qikai HUA ; Xinbao WU ; Xieyuan JIANG ; Dianying ZHANG ; Zhongguo FU ; Dankai WU ; Guangyao LIU ; Guodong LIU ; Tengbo YU ; Jinhai TAN ; Xi CHEN ; Fengfei LIN ; Zhangyuan LIN ; Dongfa LIAO ; Aiguo WANG ; Shiwu DONG ; Gaoxing LUO ; Zhao XIE ; Dong SUN ; Dehao FU ; Yunfeng CHEN ; Changqing ZHANG ; Kun LIU ; Deye SONG ; Yongjun RUI ; Fei WU ; Ximing LIU ; Junwen WANG ; Meng ZHAO ; Biao CHE ; Bing HU ; Chengjian HE ; Guanglin WANG ; Xiao CHEN ; Guandong DAI ; Shiyuan FANG ; Wenchao SONG ; Ming CHEN ; Guanghua GUO ; Yongqing XU ; Lei YANG ; Wenqian ZHANG ; Kun ZHANG ; Xin TANG ; Hua CHEN ; Weiguo XU ; Shuquan GUO ; Yong LIU ; Xiaodong GUO ; Zhewei YE ; Liming XIONG ; Tian XIA ; Hongbin WU ; Qisheng ZHOU ; Mengfei LIU ; Yiqiang HU ; Yanjiu HAN ; Hang XUE ; Kangkang ZHA ; Wei CHEN ; Zhiyong HOU ; Bin YU ; Jiacan SU ; Peifu TANG ; Baoguo JIANG ; Guohui LIU
Chinese Journal of Trauma 2025;41(5):421-432
Postoperative infection of internal fixation of closed fractures the lower limbs in adults represents a devastating complication, characterized by diagnostic challenges, prolonged treatment duration and high disability rates. Current management of these infections faces multiple challenges, such as difficulties in early accurate diagnosis, and various controversies about the treatment plan, leading to poor overall diagnosis and treatment results. To address these issues, based on evidence-based medicine and principles with emphasis on scientific rigor, clinical applicability and innovation, the Trauma Branch of the Chinese Medical Association, Orthopedic Branch of the Chinese Medical Doctor Association, Orthopedics Branch of the Chinese Medical Association, and Trauma Orthopedics and Polytrauma Group of the Resuscitation and Emergency Committee of the Chinese Medical Doctor Association have collaboratively organized a panel of relevant experts to develop the Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults ( version 2025). The guideline proposed 10 recommendations, aiming to provide a foundation for standardized diagnosis and treatment of postoperative infection in adults with closed lower limb fractures.
3.NAD+ metabolism in cardiovascular diseases.
Zhao-Zhi WEN ; Yi-Hang YANG ; Dong LIU ; Chong-Xu SHI
Acta Physiologica Sinica 2025;77(2):345-360
Cardiovascular diseases (CVDs) are the leading cause of death worldwide. Nicotinamide adenine dinucleotide (NAD+) is a central and pleiotropic metabolite involved in multiple cellular energy metabolism, such as cell signaling, DNA repair, protein modifications, and so on. Evidence suggests that NAD+ levels decline with age, obesity, and hypertension, which are all significant CVD risk factors. In addition, the therapeutic elevation of NAD+ levels reduces chronic low-grade inflammation, reactivates autophagy and mitochondrial biogenesis, and enhances antioxidation and metabolism in vascular cells of humans with vascular disorders. In preclinical animal models, NAD+ boosting also extends the health span, prevents metabolic syndrome, and decreases blood pressure. Moreover, NAD+ storage by genetic, pharmacological, or natural dietary NAD+-increasing strategies has recently been shown to be effective in improving the pathophysiology of cardiac and vascular health in different animal models and humans. Here, we discuss NAD+-related mechanisms pivotal for vascular health and summarize recent research on NAD+ and its association with vascular health and disease, including hypertension, atherosclerosis, and coronary artery disease. This review also assesses various NAD+ precursors for their clinical efficacy and the efficiency of NAD+ elevation in the prevention or treatment of major CVDs, potentially guiding new therapeutic strategies.
Humans
;
Cardiovascular Diseases/physiopathology*
;
NAD/metabolism*
;
Animals
;
Hypertension/metabolism*
4.Exploration of Milestone Evaluation System for Core Competencies in Knowledge and Skills of Neurology Residents
Liling DONG ; Dan XU ; Yuze CAO ; Siyuan FAN ; Hang LI ; Yicheng ZHU ; Lixin ZHOU ; Jun NI
Medical Journal of Peking Union Medical College Hospital 2025;16(6):1619-1628
To develop a milestone-based evaluation system for the core "knowledge and skills" competency of neurology residents that is tailored to China's medical context, so as to provide precise guidance for their training and assessment. Using the Delphi method, the study first constructed an initial framework through literature review, on-site investigation and expert-group discussion. Two rounds of expert consultation were then conducted among specialists in neurology education across China. Indicators were screened and optimized according to the mean score, agreement rate and coefficient of variation (CV), ultimately finalizing the system. The expert response rates in both rounds were 100%. The group authority coefficients were 0.97 and 0.98, with Cronbach's α of 0.90 and 0.88, respectively. The mean scores of all indicators ranged from 3.88 to 5.00, agreement rates from 62.50 % to 100 %, and CVs from 0 to 0.21. The finalized framework comprises one first-level indicator, three second-level indicators and 17 third-level indicators. The milestone evaluation system for core competencies in "knowledge and skills" of neurology residents developed in this study is scientific and reasonable, providing a standardized and scientific assessment tool for the standardized training of neurology residents.
5.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
6.Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults (version 2025)
Bobin MI ; Faqi CAO ; Weixian HU ; Wu ZHOU ; Chenchen YAN ; Hui LI ; Yun SUN ; Yuan XIONG ; Jinmi ZHAO ; Qikai HUA ; Xinbao WU ; Xieyuan JIANG ; Dianying ZHANG ; Zhongguo FU ; Dankai WU ; Guangyao LIU ; Guodong LIU ; Tengbo YU ; Jinhai TAN ; Xi CHEN ; Fengfei LIN ; Zhangyuan LIN ; Dongfa LIAO ; Aiguo WANG ; Shiwu DONG ; Gaoxing LUO ; Zhao XIE ; Dong SUN ; Dehao FU ; Yunfeng CHEN ; Changqing ZHANG ; Kun LIU ; Deye SONG ; Yongjun RUI ; Fei WU ; Ximing LIU ; Junwen WANG ; Meng ZHAO ; Biao CHE ; Bing HU ; Chengjian HE ; Guanglin WANG ; Xiao CHEN ; Guandong DAI ; Shiyuan FANG ; Wenchao SONG ; Ming CHEN ; Guanghua GUO ; Yongqing XU ; Lei YANG ; Wenqian ZHANG ; Kun ZHANG ; Xin TANG ; Hua CHEN ; Weiguo XU ; Shuquan GUO ; Yong LIU ; Xiaodong GUO ; Zhewei YE ; Liming XIONG ; Tian XIA ; Hongbin WU ; Qisheng ZHOU ; Mengfei LIU ; Yiqiang HU ; Yanjiu HAN ; Hang XUE ; Kangkang ZHA ; Wei CHEN ; Zhiyong HOU ; Bin YU ; Jiacan SU ; Peifu TANG ; Baoguo JIANG ; Guohui LIU
Chinese Journal of Trauma 2025;41(5):421-432
Postoperative infection of internal fixation of closed fractures the lower limbs in adults represents a devastating complication, characterized by diagnostic challenges, prolonged treatment duration and high disability rates. Current management of these infections faces multiple challenges, such as difficulties in early accurate diagnosis, and various controversies about the treatment plan, leading to poor overall diagnosis and treatment results. To address these issues, based on evidence-based medicine and principles with emphasis on scientific rigor, clinical applicability and innovation, the Trauma Branch of the Chinese Medical Association, Orthopedic Branch of the Chinese Medical Doctor Association, Orthopedics Branch of the Chinese Medical Association, and Trauma Orthopedics and Polytrauma Group of the Resuscitation and Emergency Committee of the Chinese Medical Doctor Association have collaboratively organized a panel of relevant experts to develop the Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults ( version 2025). The guideline proposed 10 recommendations, aiming to provide a foundation for standardized diagnosis and treatment of postoperative infection in adults with closed lower limb fractures.
7.Dosimetric effect of calculation grid size on stereotactic body radiation therapy of lung cancer in helical tomotherapy planning system
Xia-Yu HANG ; Wan-Rong JIANG ; Yi-Kun LI ; Jun HU ; Yan ZHANG ; Ruo-Qi CAO ; Nan XU ; Lei WANG ; Jin-Da ZHOU ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(2):52-57
Objective To investigate the dosimetric effects of different calculation grid size(CGS)in helical tomotherapy(HT)planning system on stereotactic body radiation therapy(SBRT)for non-small cell lung cancer(NSCLC).Methods Nine NSCLC patients receiving radiation therapy for the first time at some hospital from March 2019 to December 2022 were selected as the subjects.SBRT planning was carried out through the HT system with three different CGS plans(Fine,Normal,and Coarse)and the same pitch,modulation factor(MF)and optimization conditions,and the target area indexes of the three CGS plans were compared including conformity index(CI),homogeneity index(HI),dosimetric parameters of the organ at risk(OAR),point dose verification pass rate,treatment time,number of monitor units and Sinograms.SPSS 22.0 was used for statistical analysis.Results For target area HI,there weres significant differences between CGS Fine plan and Coarse plan and between CGS Normal plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan(P>0.05).For target area CI,there were significant differences between CGS Fine plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan and between CGS Normal plan and Coarse plan(P>0.05).For OAR dosimetric parameters,CGS Fine plan and Coarse plan had significant differences in heart Dmax and Dmean,esophageal Dmax and Dmean,V5,V20,V30 and Dmean of the whole lung and affected lung,V5 and Dmax of the affected lung and heart V10 and V30(P<0.05),CGS Normal plan and Coarse plan had obvious differences in esophageal Dmax(P<0.05),and the remained dosimetric parameters were not statistically significant(P>0.05).Fine,Normal and Coarse plans had the point dose verifica-tion pass rates being 0.96%,1.50%and 1.77%,respectively.In terms of treatment time and number of monitor units,there were significant differences between Fine plan and Coarse plan(P<0.05)while no statistical differences were found between Fine and Normal plans and between Normal and Coarse plans(P>0.05).Sinograms analyses showed Fine plan had evenly distributed segment color gradient,Coarse plan had areas of very dark and very light color gradients and Normal plan was somewhere in between.Conclusion Low CGS has to be used as much as possible to obtain accurate dose distribution during SBRT planning for NSCLC patients,which contributes to the execution of the radiation therapy plan and the prevention of ad-verse effects.[Chinese Medical Equipment Journal,2024,45(2):52-57]
8.Dosimetric effect of jaw widths on stereotactic body radiotherapy for hepatocellular carcinoma
Xia-Yu HANG ; Yi-Kun LI ; Jun HU ; Ruo-Qi CAO ; Yan ZHANG ; Nan XU ; Xian-Qiang SONG ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(7):51-55
Objective To investigate the radiotherapy dose impacts of different jaw widths on stereotactic body radiotherapy(SBRT)for hepatocellular carcinoma(HCC)with the hilical tomotherapy(HT)planning system.Methods Totally 16 HCC patients who received radiotherapy at some hospital from March 2021 to August 2023 were selected,and the planning was carried out with the same pitch,modulation factors and optimization conditions and the jaw widths being 1.0,2.5 and 5.0 cm.The dosimetric differences due to the jaw widths in planned targets and organs at risk(OAR)were compared,and the planned treatment time,monitor unit,gantry rotations and gantry period were evaluated.SPSS 22.0 was used for statistical analysis.Results Better dosimetric parameters and lower doses to OARs could be got with lower jaw widths.The widened jaw widths resulted in reduced planned treatment time,decreased monitor units and gantry rotations,shortened gantry period while enhanced treatment efficiency.Conclusion A 2.5 cm jaw width for HT planning contributes to improving treatment efficiency during HCC SBRT under the premise of ensured target dose distribution and satisfactory dose to OAR for clinical require-ments.[Chinese Medical Equipment Journal,2024,45(7):51-55]
9.Value of low-flow rate and-contrast injection scheme for pulmonary artery computed tomography angiography of elderly patients
Yue JIANG ; Min XU ; Hang-Hang SUN ; Mei-Rong SUN ; Qiu-Ju HU ; Yan-E ZHAO ; Dong-Sheng JIN
Chinese Medical Equipment Journal 2024;45(10):66-70
Objective To explore the application value of low-flow rate and-contrast injection scheme for pulmonary artery computed tomography angiography(CTA)in the elderly patients.Methods Sixty elderly patients undergoing pulmonary artery CTA in some hospital from April 2020 to January 2023 were selected and divided into a control group(30 cases)and an experimental group(30 cases)according to the contrast agent injection schemes.A conventional contrast injection scheme was used for the control group,and an optimized contrast injection scheme with low flow rate and low contrast dose was designed for the experimental group.The two gorups were observed and subjectively scored in terms of the degree of pulmonary artery enhancement,the display of pulmonary artery trunks and branches and the sharpness of image vessel edges,and objectively evaluated for the degree of contrast sclerosis artifacts in the superior vena cava and the enhancement CT values of the pulmonary artery trunks and the left and the right pulmonary veins.The extravasation of the contrast agent was recorded for the patients in the 2 groups.SPSS 25.0 software was used for statistical analysis.Results The two groups had no significant differences in score pulmonary artery CTA image quality(P>0.05);the experimental group had the socre of contrast sclerosis artifacts in the superior vena cava statistically lower than that of the control group(P<0.05).The two groups had no obvious differences in the CT values of the pulmonary artery trunks and the left and the right pulmonary veins(P>0.05).There were no patients with the extravasation of the contrast agent found in the experimental group,while there one case with severe extravasation and 4 cases with mild or moderate extravasation in the control group.Conclusion Low-flow rate and-contrast injection scheme for pulmonary artery CTA of the elderly patients contributes to avoiding contrast agent extrava-sation while ensuring image quality,enhancing patient experience and safety.[Chinese Medical Equipment Journal,2024,45(10):66-70]
10.Simultaneous determination of gefitinib,erlotinib,nilotinib and imatinib concentrations in plasma by HPLC-MS/MS
Tian-Lun ZHENG ; Jing-Pu XU ; Zhu-Hang HAN ; Wen-Li LI ; Wei-Chong DONG ; Zhi-Qing ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(6):899-903
Objective To establish a high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)for the simultaneous determination of gefitinib,erlotinib,nillotinib and imatinib plasma concentrations and analyze the results.Methods The plasma samples were treated with acetonitrile precipitation and separated by Diamonsil C18 column(150 mm ×4.6 mm,3.5 μm)with mobile phase of 0.1%formic acid water(A)-0.1%formic acid acetonitrile(B).The flow rate of gradient elution was 0.7 mL·min-1,and the column temperature was 40 ℃ and the injection volume was 3 μL.Using arotinib as the internal standard,the scanning was carried out by using electrospray ionization source in positive ionization mode with multi-reaction monitoring.The specificity,standard curve,lower limit of quantitation,precision,accuracy,recovery rate,matrix effect and stability of the method were investigated.The concentrations of imatinib and erlotinib in 20 patients with chronic myelogenous leukemia(CML)and gefitinib and erlotinib in 3 patients with non-small cell lung cancer were measured.Results The standard curves of the four drugs were as follows,gefitinib:y=2.536 × 10-3x+9.362 × 10-3(linear range 20-2 000 ng·mL-1,R2=0.996 6);erlotinib:y=3.575× 10-3x+7.406 × 10-3(linear range 50-5 000 ng·mL-1,R2=0.994 9);nilotinib:y=1.945 x 10-3x+0.015 643(linear range 50-5 000 ng·mL-1,R2=0.990 6);imatinib:y=4.56 x 10-3x+0.010 451(linear range 100~104 ng·mL-1,R2=0.9963).RSD of intra-day and inter-day were less than 10%,and the accuracy ranged from 90%to 110%,and the recovery rates were 91.35%to 98.93%(RSD<10%);the matrix effect ranged from 91.64%to 107.50%(RSD<10%).Determination of 23 patients showed that the blood concentration of nilotinib ranged from 623.76 to 2 934.13 ng·mL-1,and the blood concentration of imatinib ranged from 757.77 to 2 637.71 ng·mL-1,and the blood concentration of gefitinib ranged from 214.76 to 387.40 ng·mL-1.The serum concentration of erlotinib was 569.57 ng·mL-1.Conclusion The method of this research is simple,fast,sensitive and dedicated,which can be monitored by the concentration of clinical blood.

Result Analysis
Print
Save
E-mail