1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Optimization of drug dispensing and pickup process in traditional Chinese medicine pharmacy based on data-intelligence-driven
Qi WANG ; Panke ZENG ; Haoxin SONG ; Yonggang FENG ; Lili SUN ; Jingting FENG ; Weiqing NIU ; Haiyan DONG ; Feng WANG
China Pharmacy 2026;37(5):660-664
OBJECTIVE To explore the transformation of the dispensing and drug pickup process in traditional Chinese medicine pharmacy (TCM Pharmacy) in our hospital based on data-intelligence-driven, aiming to improve pharmacists’ work efficiency and patients’ drug pickup experience. METHODS Value stream mapping and journey mapping were used to systematically identify non-value-added links in pharmacists’ dispensing process and key pain points in patients’ drug pickup under the traditional process. An intelligent dispensing and drug pickup system for the TCM Pharmacy was developed based on the C# and Android television platforms, and a machine-learning model was adopted to predict patients’ drug pickup waiting time. A comprehensive evaluation was performed from three perspectives: system performance, prediction accuracy, and satisfaction of pharmacists and patients. RESULTS The system successfully streamlined non-value-added links such as “waiting for writing on the board” and “searching for drugs”, and realized multimodal dynamic prompts of dispensing status through auditory (number calling) and visual (television terminal) channels. The constructed model for predicting drug pickup waiting time exhibited good fitting degree and generalization ability (mean absolute error=4.28 min, R 2 =0.882). The comprehensive satisfaction scores of pharmacists and patients in the traditional mode were significantly increased from (70.99±1.74) and (73.58±1.98) to (90.02±1.30) and (88.61±2.08) in the new system, respectively ( P <0.01). CONCLUSIONS The transformation of the intelligent drug dispensing and pickup system for TCM pharmacy based on data-intelligence-driven effectively improves the efficiency of pharmacists’ dispensing work, realizes process transparency and waiting time predictability, and significantly enhances patients’ drug pickup experience.
3.Ethical dilemmas and governance strategies of the integrated medical and elderly care model
Buke SUN ; Xinyi DONG ; Xuelan ZENG
Chinese Medical Ethics 2026;39(1):113-120
The integrated medical and elderly care model is a new type of elderly care model designed to address the demands of the elderly in terms of physical health, daily care, and spiritual comfort. It has significant practical significance for actively responding to the problems of population aging. However, this model still faces a series of ethical dilemmas in practical. By analyzing the ethical issues that may arise during the integration of medical and elderly care services, including conflicts between medical care and elderly autonomy, the challenges faced by informed consent, conflicts of interest between medical and elderly care services, and blurred boundaries between family care and social care, this paper proposed corresponding strategies, such as improving the construction of personalized care mechanisms, optimizing multi-level protection systems for informed consent, establishing a unified interest coordination mechanism and resource sharing platform, and strengthening the synergy between family support and social care. These strategies aimed to promote the healthy development of the integrated medical and elderly care model, ensure the protection of the basic rights and interests and well-being of the elderly to the greatest extent, and ultimately achieve a fairer and more sustainable aging social governance system.
4.A study on the application of predictive extracorporeal membrane oxygenation intraoperative support in high-risk liver transplant recipients
Zhiying LEI ; Xuyong SUN ; Yuanyuan MO ; Jianhui DONG ; Ning WEN ; Rong PENG ; Juhua ZENG ; Silin LI
Organ Transplantation 2026;17(4):618-624
Objective To investigate the clinical safety and efficacy of predictive extracorporeal membrane oxygenation (ECMO) support during liver transplantation in high-risk recipients. Methods A single-center retrospective study was conducted. A total of 35 liver transplant recipients who underwent predictive ECMO assistance during surgery at the Second Affiliated Hospital of Guangxi Medical University from January 2021 to April 2025 were included. Baseline characteristics, ECMO application, ECMO operating parameters and hemodynamic conditions during ECMO operation were analyzed. The cumulative survival rate was calculated using the Kaplan-Meier method and survival curves were plotted. Results Veno-arterial ECMO in 35 recipients was established after induction of general anesthesia. The median ECMO operation time was 8.5 h, and the success rate of weaning from ECMO was 97%. The cardiac index (CI) during the non-liver period and the new liver period was higher than that before cannulation, and CI increased during the non-liver period and before weaning (all P<0.001). The mean invasive arterial pressure and central venous pressure remained stable. No ECMO-related complications occurred in the recipients. The average survival time was (25 ± 3) months. The main causes of death were severe pulmonary infection and multiple organ failure. Conclusions For liver transplant recipients with severe cardiopulmonary dysfunction, hemodynamic disorders, or multiple organ failure risk factors, implementing predictive ECMO support during liver transplantation through active risk prediction is a safe and effective circulatory guarantee strategy.
5.Reconstructing The Testicular Niche: Mechanisms and Translational Perspectives of Stem Cell-derived Testicular Organoids
Xia DONG ; Tai-Zeng ZHOU ; Lin-Yuan SHEN ; Li ZHU ; Mai-Lin GAN
Progress in Biochemistry and Biophysics 2026;53(8):2242-2246
Mammalian male germline development depends on a specialized gonadal somatic microenvironment. However, itsin vitro reconstruction remains challenging. Major barriers include the generation of appropriate supporting-cell lineages, organized tissue architecture, and culture conditions that sustain germ-cell maturation. Yoshino et al. established a mouse pluripotent stem cell-derived testicular organoid model. This model reconstitutes the sex-determining region Y (Sry)-SRY-box transcription factor 9 (Sox9)‑mediated sex-determination program and generates testicular somatic cell-like cells (TesLCs). When assembled with primordial germ cell-like cells (PGCLCs), TesLCs formed seminiferous tubule-like structures and supported male germline progression toward prospermatogonia and germline stem cell-like cells (GSCLCs). After transplantation into infertile recipient testes, organoid-derived GSCLCs produced fertilization-competent sperm and generated fertile offspring. The major significance of this work extends beyond sperm production. It integrates sex determination, germ-cell fate transition, and testicular niche self-organization into an experimentally tractable organoid system. This commentary discusses the technical strategy, sex-determination mechanism, value of testicular niche reconstruction, and translational limitations of this study. It also highlights its implications for in vitro gametogenesis, male infertility modeling, and reproductive medicine.
6.Potential confusion risk screening and display-name optimization for Chinese drug names based on a multimodal similarity model
Feng WANG ; Qi WANG ; Yuanyuan FAN ; Panke ZENG ; Haiyan DONG
China Pharmacy 2026;37(19):2570-2576
OBJECTIVE To construct a multimodal similarity model for Chinese drug names and design optimized display names,compare the potential confusion risk of display names of the same drug catalogue in different scenarios,so as to provide a quantitative basis for the management of drug display names.METHODS A total of 1 221 drug entries were extracted from the drug dictionary of a tertiary grade A hospital,forming 744 810 drug pairs. “Five rules” were summarized based on the confusion characteristics of candidate confusable drug pairs under the currently used in-hospital display names (Scenario 1) and standard display names (Scenario 2),to generate optimized display names (Scenario 3). A multimodal similarity model integrating Pinyin,glyph,character sequence and rendered visual features was constructed. The same threshold (total similarity S total ≥0.70) was adopted to screen candidate confusable drug pairs. Confusion risk grading and transition,confusion characteristic labeling,confusion network clustering and residual cluster analysis were carried out. The naming mechanism of optimized display names was investigated through display morphology indicators and rule ablation,and the robustness of the comparison results among the three scenarios was evaluated through similarity threshold and fusion weight sensitivity analysis.RESULTS The numbers of candidate confusable drug pairs in the three scenarios were 156,269 and 83 respectively,among which the number of pairs at high risk and above was 109, 215 and 64 respectively. Compared with Scenario 1,Scenario 3 reduced the number of candidate confusable drug pairs by 46.8%,and the number of those at high risk or above decreased by 41.3%. Display morphology analysis showed that Scenario 3 had the lowest average ink density (0.057 3) and the largest average number of structural slots (2.99). Rule ablation analysis showed that after disabling the rule of manufacturer characteristic abbreviation prompts,the number of candidate confusable drug pairs increased the most (+74 pairs),while disabling structured naming alone resulted in a net decrease of 9 pairs. The residual clusters mainly involved drugs with the same active ingredient but different specifications or subtypes,as well as series products from the same manufacturer with similar main name stems. Under the threshold setting of 0.60 to 0.80 with a step size of 0.025 and 11 different weight configurations (including the baseline value),the number of candidate confusable drug pairs always maintained the ranking of Scenario 3<Scenario 1<Scenario 2.CONCLUSIONS The multimodal similarity model can be used for quantitative screening of potential confusion of Chinese drug display names,and the ranking of the number of candidate confusable drug pairs among scenarios remains stable within the set parameter range. The optimized display names based on the “five rules” can reduce the number of candidate confusable drug pairs, and the number of those at high risk or above in the hospital’s drug catalogue,but their impact on actual identification behavior and clinical medication safety still needs further verification.
7.Application of Carbon Nanoparticle-Manganese Dioxide Injection in Gastrointestinal Staining-Based Marking and Localization in Rats and Pigs
Wanlin CHEN ; Qingrui DONG ; Mengtao LI ; Nan LIN ; Hu ZHAO ; Zaizhong ZHANG ; Lingjun ZENG ; Pei LI ; Jin YANG ; Yu WANG ; Aiwen HUANG
Laboratory Animal and Comparative Medicine 2026;46(5):727-739
ObjectiveTo develop a carbon nanoparticle-manganese dioxide (CN-MnO2) injection integrating visually identifiable staining and magnetic resonance (MR) T1/T2 dual-modal imaging, and to systematically evaluate its physicochemical properties, critical quality attributes, biocompatibility, and efficacy for gastrointestinal marking and localization. MethodsCN-MnO2 was prepared using a mild liquid-phase in situ redox deposition strategy and characterized by transmission electron microscopy (TEM), dynamic light scattering (DLS), zeta potential analysis, X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD). The pH of CN-MnO2 was directly measured using a pH meter. The osmolality pressure of CN-MnO2 was determined by the freezing point depression method. The bacterial endotoxin was detected using the gel-clot Limulus amebocyte lysate test, which did not rely on absorbance readings. The appearance of the CN-MnO2 injection solution stored at 4 ℃ under light shielding and sealed for 0, 5, and 10 days was observed, and its hydrated particle size, polydispersity index, zeta potential, and pH were also measured. With gadopentetate dimeglumine (Gd-DTPA) as the positive control, different concentration gradients were established, and T1 and T2 relaxation times were measured to construct concentration-dependent plots of the longitudinal and transverse relaxation rates (R1 and R2) and calculate the corresponding relaxivities (r1 and r2), compare relaxivity performance, and determine the working concentration for subsequent in vivo experiments. Cytocompatibility was assessed using the methyl thiazolyl tetrazolium (MTT) assay and live/dead staining. Sixteen male 6-week-old SD rats were randomly assigned to an experimental group and a control group (n=8 per group) and subcutaneously injected with CN-MnO2 injection at a total Mn concentration of 0.80 mmol/L or an equal volume of normal saline, respectively. Short-term in vivo safety was evaluated by regular body weight monitoring, hematoxylin-eosin (HE) staining of major organs, hematological and serum biochemical analyses, inflammatory cytokine detection, and inductively coupled plasma optical emission spectrometry (ICP-OES) analysis. Eight male 5–6-month-old Bama minipigs were randomly assigned to a CN-MnO2 group (n=6) and a carbon nanoparticle suspension injection (CNSI) group (n=2). CN-MnO2 injection or CNSI was injected subserosally into the stomach, small intestine, and colon. Within 5 min after each injection, the maximum staining diameter at each injection site was measured and recorded. MR T1WI/T2WI scans were performed on days 3 and 7 after injection to evaluate MR visualization at the injection sites. At the end of observation, the injection sites and major organs were collected for histopathological evaluation by hematoxylin-eosin staining. ResultsCN-MnO2 appeared as a black suspension, with no obvious aggregation or sedimentation after standing at room temperature (20-25 ℃) for 15 days. Its average hydrodynamic diameter was approximately (228.7±15.3) nm, the polydispersity index was 0.184±0.021, and the zeta potential was (-24.6±2.8) mV. XPS showed that CN-MnO2 was mainly composed of C, O, and Mn, with oxygen accounting for approximately 68.82%. The Mn 2p spectrum exhibited two characteristic peaks at 642.4 and 653.1 eV. XRD indicated that low-crystallinity δ-MnO2 was dispersed within the carbon matrix. The pH was 6.82±0.06, the osmolality was (298.4±6.7) mOsm/kg, and the bacterial endotoxin level was below the detection limit. In vitro MR imaging showed a clear concentration-dependent response, with r1 and r2 values of 9.6 L·mmol-1·s-1 and 17.2 L·mmol-1·s-1, respectively, indicating favorable T1/T2 contrast performance superior to that of Gd-DTPA. At 0.80 mmol/L, CN-MnO2 showed no obvious cytotoxicity in vitro. Short-term safety evaluation in SD rats revealed no obvious inflammatory response, impairment of liver or renal function, or abnormal manganese accumulation in major organs. In Bama minipigs, the mean staining diameters of the CN-MnO2 group in the stomach, small intestine, and colon were (0.65±0.12) cm, (0.61±0.11) cm, and (0.58±0.10) cm, respectively, with no significant difference among the three injection sites (P>0.05). The overall mean staining diameter was smaller in the CN-MnO2 group than in the CNSI group (P<0.05). MR examinations showed that the injection sites were identifiable on both day 3 and day 7, with stronger signals observed on day 3. At the end of observation, no obvious pathological abnormalities were observed at the injection sites or in major organs. ConclusionA CN-MnO2 injection with uniform particle size and stable physicochemical properties can be successfully prepared. This formulation integrates visible gastrointestinal staining with MR T1/T2 dual-modal imaging, providing a new strategy for preoperative gastrointestinal marking and localization as well as precise intraoperative resection.
8.Application of serological methods combined with flow cytometry in the detection of immune hemolytic transfusion reaction
Lei LIU ; Qunjuan ZENG ; Guoqin GONG ; Dong XIANG ; Zhongying WANG
Chinese Journal of Blood Transfusion 2025;38(1):116-121
[Objective] To explore the effects of different methods on antibody detection through investigating the causes of cross-matching incompatible in a patient with gastric malignant tumor, and to establish flow cytometry protocol for confirming hemolytic transfusion reaction (HTR). [Methods] Antibodies in the patient's serum were identified by red blood cells (RBCs) blood grouping, antibody screening and identification, acid elution test and PEG enhancement test. To confirm HTR, patient RBCs, proximal and distal ends RBCs, separated by capillary centrifugation, were tested by direct antiglobulin test (DAT) and Jka antigen single label and double label flow cytometry. [Results] Routine serological technology revealed the presence of anti-C, e (titer:2) and anti-Jka (titer >1) in the patient’s serum. After separation using capillary centrifugation technology, both the proximal and distal DAT and Jka antigen tests were negative. Both DAT and Jka antigen positive red blood cells (0.21%, 6/6 327) were found in the patient's blood samples by flow cytometry. After separation of blood samples by capillary centrifugation, there were significantly more DAT and Jka antigen double-positive RBCs in the distal end (0.43%, 33/7 707) than in the proximal end (0.09%, 15/7 225). Two blood samples were screened from over 100 donor blood samples that are compatible with the patient's cross-matching, and the transfusion effect was favorable. [Conclusion] Serological methods combined with flow cytometry could improve the sensitivity of antibody detection, provide a more accurate basis for the diagnosis of HTRs, and guarantee the safety of blood transfusion.
9.Clinical observation of acupuncture and Tuina combined with Ba Duan Jin in improving motor function in patients with Parkinson disease in the early and middle stages
Liang ZENG ; You GU ; Jiawei HU ; Hualan YANG ; Xiaowei DONG ; Guoliang PAN ; Fei ZHOU ; Ling'er LIU
Journal of Acupuncture and Tuina Science 2025;23(2):151-158
Objective:To observe the improving effect of acupuncture and Tuina(Chinese therapeutic massage)combined with Ba Duan Jin(Eight-brocade Exercise)on motor function in patients with Parkinson disease(PD)in the early and middle stages.Methods:Seventy patients with early-or middle-stage PD were randomly divided into a control group and an observation group,with 35 patients in each group.The control group was given conventional treatment such as oral levodopa hydrochloride tablets;the observation group was treated with acupuncture,Tuina,and Ba Duan Jin in addition to the control group's treatment.Acupuncture and Tuina were administered twice a week,and Ba Duan Jin was performed five times a week.Each course of treatment lasted 4 weeks,and a total of 3 courses were completed.The changes in the unified Parkinson disease rating scale Ⅲ(UPDRS Ⅲ)score,Berg balance scale(BBS)score,15-meter walking speed,and 6-minute walk distance were compared between the two groups.Results:The total effective rate in the observation group was 93.6%,which was significantly higher than 45.7%in the control group(P<0.01).After 4,8,and 12 weeks of treatment,the UPDRS Ⅲ score in the observation group was significantly lower than the previous score(P<0.05);the BBS score was significantly higher than the previous score(P<0.05),and the 6-minute walk distance also significantly increased compared to the previous result(P<0.05).After 8 and 12 weeks of treatment,the 15-meter walking speed in the observation group was significantly higher than that before treatment and the previous measurement(P<0.05).In comparison with the control group,the observation group showed significantly lower UPDRS Ⅲ scores after 8 and 12 weeks of treatment(P<0.05).Additionally,after 4,8,and 12 weeks of treatment,the observation group had significantly higher BBS scores,15-meter walking speed,and the 6-minute walk distance than the control group(P<0.05).There were no significant differences in the above indicators before and after treatment in the control group(P>0.05).Conclusion:The addition of acupuncture,Tuina,and Ba Duan Jin to Western medication treatment can effectively improve motor function,balance ability,and walking ability in patients with early-or middle-stage PD.
10.Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture-dislocation in adults (version 2025)
Qingde WANG ; Tongwei CHU ; Jian DONG ; Liangjie DU ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Yong HAI ; Da HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Fang LI ; Feng LI ; Li LI ; Weishi LI ; Fangcai LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Xuhua LU ; Keya MAO ; Xuexiao MA ; Yong QIU ; Limin RONG ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Bing WANG ; Linfeng WANG ; Yu WANG ; Qinghe WANG ; Jigong WU ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Yong YANG ; Qiang YANG ; Cao YANG ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Zezhang ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Yan ZENG ; Dingjun HAO ; Baorong HE ; Wei MEI
Chinese Journal of Trauma 2025;41(3):243-252
Cervical spinal cord injury without fracture-dislocation (CSCIWFD) is referred to as a special type of cervical spinal cord injury characterized by traumatic spinal cord dysfunction and no significant bony structural abnormalities on imagines. Duo to the high risk of missed diagnosis during the initial consultation, CSCIWFD may lead to progressive neurological deterioration or even complete paralysis, severely impacting patients′ prognosis. Currently, there are no established consensuses over the diagnosis and treatment of CSCIWFD, such as the lack of evidence-based standards for indications of non-surgical treatment and risk of secondary neurological injury, as well as debates over the optimal timing for surgical intervention and indications for different surgical approaches. To address these issues, the Spine Trauma Group of the Orthopedic Branch of the Chinese Medical Doctor Association organized experts in the relevant fields to formulate Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture- dislocation in adults ( version 2025) . Based on evidence-based medicine and the principles of scientific rigor and clinical applicability, the guidelines proposed 11 recommendations covering terminology, diagnosis, evaluation treatment, and rehabilitation, etc., aiming to standardize the management of CSCIWFD.

Result Analysis
Print
Save
E-mail