1.Liver Cirrhosis Progression in a Patient with Overlapping IgG4-Related Sclerosing Cholangitis and Primary Biliary Cholangitis
Dong Wook KIM ; Hee Yoon NOH ; Song-Hee HAN ; Myung Hwan NOH
Korean Journal of Pancreas and Biliary Tract 2025;30(2):87-92
We report a rare case of overlapping immunoglobulin G4-sclerosing cholangitis (IgG4-SC) and primary biliary cholangitis (PBC) in a 78-year-old woman presenting with sudden-onset jaundice, cholestatic liver enzyme elevation, and biliary strictures. Elevated alkaline phosphatase levels, positive antimitochondrial antibodies, increased serum IgG4 levels, and a high IgG4/IgG ratio, combined with endobiliary biopsy via endoscopic retrograde cholangiopancreatography biopsy showing lymphoplasmacytic infiltration and IgG4-positive cells, confirmed the diagnosis. Initial treatment with biliary drainage, ursodeoxycholic acid (UDCA), and corticosteroids provided temporary relief; however, the patient experienced recurrent episodes of cholangitis and biliary obstruction, eventually progressing to decompensated cirrhosis over 2 years. This case highlights the importance of considering IgG4-SC in patients with PBC who fail to respond adequately to UDCA and underscores the significant challenges in diagnosing and managing such overlapping syndromes. Further research is crucial to better understand the underlying pathophysiology, refine therapeutic strategies, and improve clinical outcomes of these rare, complex autoimmune conditions.
2.Biennial Mammography Performance in the Korean National Cancer Screening Program From 2009 to 2020
Dong Jun KIM ; Nan-He YOON ; Jae Kwan JUN ; Mina SUH ; Sunhwa LEE ; Seongju KIM ; Horim A. HWANG ; Seung Eun JUNG ; Hooyeon LEE
Korean Journal of Radiology 2025;26(4):313-323
Objective:
Mammography is essential for reducing breast cancer mortality; however, its performance varies globally. This study aimed to evaluate mammography screening outcomes in Korea over 12 years and investigate regional variations.
Materials and Methods:
We analyzed mammography data from 42 million Korean women, aged 40 years and older, who participated in the Korean National Cancer Screening Program (KNCSP) from 2009 to 2020. Performance metrics—including recall rate (RR), positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), cancer detection rate (CDR), interval cancer rate (ICR), and dense breast rate (DBR), were computed. Twelve-year trends in these metrics were analyzed using Joinpoint regression. Regional variations were also examined across Korea’s 237 districts, stratified by age groups.
Results:
From 2009 to 2020, 42165405 mammography screenings were conducted through the KNCSP, increasing from 2821132 screenings in 2009 to 3596204 in 2020. The RR decreased from 17.2% in 2009 to 11.2% in 2020 (average annual percent change [AAPC] = -3.7%), while the PPV increased from 0.8% to 2.8%; AAPC = 10.7%), the CDR increased from 1.5 to 3.1 per 1000; AAPC = 7.3%), and the ICR rose from 0.9 to 1.6 per 1000; (AAPC = 5.2%). Regional variations were noted; however, differences in the RR, sensitivity, specificity, and FPR decreased over time.
Conclusion
While mammography performance improved from 2009 to 2020, the PPV and sensitivity remain suboptimal, underscoring the need for continuous monitoring. Regional disparities in performance, although reduced, persist. These findings provide essential baseline data for improving mammography quality and addressing inequities in breast cancer screening.
3.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
4.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
5.Detection of Clarithromycin Resistance in Helicobacter pylori Using the AllplexTM H. pylori & ClariR Assay and the Ezplex® HP-CLA Real-Time PCR Kit
Tae-Woo KIM ; Won Seok LEE ; Dong Jin YOON ; Ilsoo KIM ; Joon Sung KIM
The Korean Journal of Helicobacter and Upper Gastrointestinal Research 2025;25(1):42-47
Objectives:
The success of Helicobacter pylori eradication using clarithromycin-based triple therapy relies on the bacteria being sensitive to clarithromycin. This study evaluated the diagnostic performance of two frequently used polymerase chain reaction (PCR) methods (AllplexTM H. pylori & ClariR Assay [Seegene] and Ezplex® HP-CLA Real-time PCR [SML Genetree]) to detect H. pylori infection and identify point mutations associated with clarithromycin resistance.
Methods:
Patients who underwent esophagogastroduodenoscopy between August 2023 and April 2024 at Incheon St. Mary’s Hospital were enrolled in this study. The diagnostic performance of the Allplex method was evaluated against the rapid urease test (RUT), culture, and Ezplex HP-CLA methods. Point mutation detection using the Allplex and Ezplex methods was compared with the results of gene sequencing. The rates of H. pylori eradication following Ezplex-based tailored therapy were also analyzed.
Results:
Eighty-seven gastric biopsy specimens were analyzed. For diagnosing H. pylori infections, Allplex demonstrated kappa values of 0.670 compared with RUT, 0.468 compared with culture, and 0.880 compared with Ezplex. Among the 87 bacterial isolates subjected to gene sequencing to detect clarithromycin resistance-associated point mutations, the Allplex and Ezplex methods demonstrated 74 and 76 concordant results, respectively. The H. pylori eradication rate using Ezplex-based tailored therapy was 90.7%.
Conclusions
This study demonstrated that both the Allplex and Ezplex methods are helpful for diagnosing H. pylori infections and detecting clarithromycin resistance. Furthermore, the Ezplex method was clinically effective for guiding tailored therapy to yield successful H. pylori eradication.
6.Characteristics and outcomes of portal vein thrombosis in patients with inflammatory bowel disease in Korea
Ki Jin KIM ; Su-Bin SONG ; Jung-Bin PARK ; June Hwa BAE ; Ji Eun BAEK ; Ga Hee KIM ; Min-Jun KIM ; Seung Wook HONG ; Sung Wook HWANG ; Dong-Hoon YANG ; Byong Duk YE ; Jeong-Sik BYEON ; Seung-Jae MYUNG ; Suk-Kyun YANG ; Chang Sik YU ; Yong-Sik YOON ; Jong-Lyul LEE ; Min Hyun KIM ; Ho-Su LEE ; Sang Hyoung PARK
The Korean Journal of Internal Medicine 2025;40(2):243-250
Background/Aims:
Portal vein thrombosis (PVT) frequently occurs in patients with inflammatory bowel disease (IBD), particularly when influenced by factors such as abdominal infections, IBD flare-ups, or surgical procedures. The implications of PVT range from immediate issues such as intestinal ischemia to long-term concerns including portal hypertension and its complications. However, there is a notable gap in comprehensive studies on PVT in IBD, especially with the increasing incidence of IBD in Asia. This research aimed to evaluate the clinical features and outcomes of PVT in patients with IBD at a leading hospital in South Korea.
Methods:
This retrospective analysis reviewed adult patients diagnosed with both IBD and PVT from 1989 to 2021 at a renowned South Korean medical center. The study focused on patient characteristics, specifics of PVT, administered treatments, and outcomes, all confirmed through enhanced CT scans.
Results:
A total of 78 patients met the study’s criteria. Notably, only 20.5% (16/78) were treated with oral anticoagulants; however, a vast majority (96.2%; 75/78) achieved complete radiographic resolution (CRR). When comparing patients receiving anticoagulants to those who did not, a significant preference for anticoagulant use was observed in cases where the main portal vein was affected, as opposed to just the left or right veins (p = 0.006). However, multivariable analysis indicated that neither anticoagulant use nor previous surgeries significantly impacted CRR.
Conclusions
Patients with IBD and PVT generally had favorable outcomes, regardless of anticoagulant use.
7.Liver Cirrhosis Progression in a Patient with Overlapping IgG4-Related Sclerosing Cholangitis and Primary Biliary Cholangitis
Dong Wook KIM ; Hee Yoon NOH ; Song-Hee HAN ; Myung Hwan NOH
Korean Journal of Pancreas and Biliary Tract 2025;30(2):87-92
We report a rare case of overlapping immunoglobulin G4-sclerosing cholangitis (IgG4-SC) and primary biliary cholangitis (PBC) in a 78-year-old woman presenting with sudden-onset jaundice, cholestatic liver enzyme elevation, and biliary strictures. Elevated alkaline phosphatase levels, positive antimitochondrial antibodies, increased serum IgG4 levels, and a high IgG4/IgG ratio, combined with endobiliary biopsy via endoscopic retrograde cholangiopancreatography biopsy showing lymphoplasmacytic infiltration and IgG4-positive cells, confirmed the diagnosis. Initial treatment with biliary drainage, ursodeoxycholic acid (UDCA), and corticosteroids provided temporary relief; however, the patient experienced recurrent episodes of cholangitis and biliary obstruction, eventually progressing to decompensated cirrhosis over 2 years. This case highlights the importance of considering IgG4-SC in patients with PBC who fail to respond adequately to UDCA and underscores the significant challenges in diagnosing and managing such overlapping syndromes. Further research is crucial to better understand the underlying pathophysiology, refine therapeutic strategies, and improve clinical outcomes of these rare, complex autoimmune conditions.
8.Biennial Mammography Performance in the Korean National Cancer Screening Program From 2009 to 2020
Dong Jun KIM ; Nan-He YOON ; Jae Kwan JUN ; Mina SUH ; Sunhwa LEE ; Seongju KIM ; Horim A. HWANG ; Seung Eun JUNG ; Hooyeon LEE
Korean Journal of Radiology 2025;26(4):313-323
Objective:
Mammography is essential for reducing breast cancer mortality; however, its performance varies globally. This study aimed to evaluate mammography screening outcomes in Korea over 12 years and investigate regional variations.
Materials and Methods:
We analyzed mammography data from 42 million Korean women, aged 40 years and older, who participated in the Korean National Cancer Screening Program (KNCSP) from 2009 to 2020. Performance metrics—including recall rate (RR), positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), cancer detection rate (CDR), interval cancer rate (ICR), and dense breast rate (DBR), were computed. Twelve-year trends in these metrics were analyzed using Joinpoint regression. Regional variations were also examined across Korea’s 237 districts, stratified by age groups.
Results:
From 2009 to 2020, 42165405 mammography screenings were conducted through the KNCSP, increasing from 2821132 screenings in 2009 to 3596204 in 2020. The RR decreased from 17.2% in 2009 to 11.2% in 2020 (average annual percent change [AAPC] = -3.7%), while the PPV increased from 0.8% to 2.8%; AAPC = 10.7%), the CDR increased from 1.5 to 3.1 per 1000; AAPC = 7.3%), and the ICR rose from 0.9 to 1.6 per 1000; (AAPC = 5.2%). Regional variations were noted; however, differences in the RR, sensitivity, specificity, and FPR decreased over time.
Conclusion
While mammography performance improved from 2009 to 2020, the PPV and sensitivity remain suboptimal, underscoring the need for continuous monitoring. Regional disparities in performance, although reduced, persist. These findings provide essential baseline data for improving mammography quality and addressing inequities in breast cancer screening.
9.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
10.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.

Result Analysis
Print
Save
E-mail