1.Assessment of Long-Term Stability of External Quality Control Materials: Defibrinated Pooled Plasma for Examination of Hepatitis Viral Markers
Hyunhye KANG ; Dong Wook JEKARL ; Seung Hyo YOO ; Ae-Ran CHOI ; Eun-Jee OH
Journal of Laboratory Medicine and Quality Assurance 2024;46(1):66-71
Since 2016, the external quality assessment program of The Korean Association of External Quality Assessment Service for hepatitis serology has employed pooled serum specimens. Ten test items include hepatitis B virus surface antigen (HbsAg), hepatitis B virus surface antibody (anti-HBs), hepatitis B virus core antibody (anti-HBc) total, anti-HBc immunoglobulin M (IgM), hepatitis B virus envelope antigen (HBeAg), hepatitis B virus envelope antibody (anti-HBe), hepatitis C virus antibody (anti-HCV), hepatitis A virus antibody (anti-HAV) total, anti-HAV immunoglobulin G (IgG), and anti-HAV IgM. We aimed to evaluate the long-term stability of pooled serum specimens using fresh frozen plasma stored at different temperatures. In the first trial conducted in 2019, an additional 432 samples were prepared and tested for long-term stability at room temperature for 2 weeks, refrigerated for 1 month, and frozen (-20℃ and -80℃) for 6 months to 1 year. Furthermore, the stability of the samples was evaluated based on the number of repeated refrigeration and freezing cycles. The prepared pooled sera specimens for hepatitis serology were stable for up to 10 days at 2–8℃, 2–3 months at -20℃ and -80℃, and four freeze-thaw cycles, with the quantitative indices of all tests deviating within 10%. The results of this study are expected to contribute to the stable implementation and quality improvement of the hepatitis virus antigen-antibody test reliability survey project.
2.Transfusion support in hematopoietic stem cell transplantation
Dong Wook JEKARL ; Jae Kwon KIM ; Jay Ho HAN ; Howon LEE ; Jaeeun YOO ; Jihyang LIM ; Yonggoo KIM
Blood Research 2023;58(S1):1-7
Transfusion support for hematopoietic stem cell transplantation (HSCT) is an essential part of supportive care, and compatible blood should be transfused into recipients. As leukocyte antigen (HLA) matching is considered first and as the blood group does not impede HSCT, major, minor, bidirectional, and RhD incompatibilities occur that might hinder transfusion and cause adverse events. Leukocyte reduction in blood products is frequently used, and irradiation should be performed for blood products, except for plasma. To mitigate incompatibility and adverse events, local transfusion guidelines, hospital transfusion committees, and patient management should be considered.
3.Thrombocytopenia Experienced by Healthy Peripheral Blood Stem Cell Donors at a Tertiary Hospital in Korea
Soo Jung LEE ; Seungwan CHAE ; Jung Sil HWANG ; Seung Hyo YOO ; Jayho HAN ; Howon LEE ; Dong Wook JEKARL ; Yonggoo KIM
Korean Journal of Blood Transfusion 2023;34(2):108-117
In healthy peripheral blood stem cell (PBSC) donors, rare cases of transient thrombocytopenia have been reported due to the administration of granulocyte colony-stimulating factor (G-CSF) or the apheresis itself. Meanwhile, differentiating pseudothrombocytopenia induced by anticoagulants is crucial, as it can result in false low platelet counts. This study aimed to investigate the causes of thrombocytopenia in healthy PBSC donors. We investigated PBSC donors who experienced thrombocytopenia during transplantation at St. Mary’s Hospital, Seoul. Three donors were identified and donor workup studies were within the normal limits. After G-CSF administration prior to transplantation, the donors experienced a significant reduction in platelet counts. Apheresis resulted in lower levels, yet platelet counts returned to normal levels approximately two weeks later. In donor 3, thrombocytopenia was seen during the donor workup and ethylenediaminetetraacetic acid (EDTA)-induced pseudothrombocytopenia was identified after the supplementation of amikacin. For donor 3, we investigated whether his recipient’s sample showed EDTA-induced pseudothrombocytopenia through a review of any platelet clumping in the apheresis product and the presence of immunoglobulin M (IgM) or IgG antiplatelet antibodies in the recipient’s peripheral blood. In conclusion, the risk of severe thrombocytopenia with G-CSF administration in PBSC donors should be considered and accurate differentiation of pseudothrombocytopenia is imperative.
4.Indirect Method for Estimation of Reference Intervals of Inflammatory Markers
Taewon KANG ; Jeaeun YOO ; Dong Wook JEKARL ; Hyojin CHAE ; Myungshin KIM ; Yeon-Joon PARK ; Eun-Jee OH ; Yonggoo KIM
Annals of Laboratory Medicine 2023;43(1):55-63
Background:
The direct method for reference interval (RI) estimating is limited due to the requirement of resources, difficulties in defining a non-diseased population, or ethical problems in obtaining samples. We estimated the RI for inflammatory biomarkers using an indirect method (RII).
Methods:
C-reactive protein (CRP), erythrocyte sedimentation rate (ESR) and presepsin (PSEP) data of patients visiting a single hospital were retrieved from April 2009 to April 2021. Right-skewed data were transformed using the Box-Cox transformation method. A mixed population of non-diseased and diseased distributions was assumed, followed by latent profile analysis for the two classes. The intersection point of the distribution curve was estimated as the RI. The influence of measurement size was evaluated as the ratio of abnormal values and adjustment (n×bandwidth) of the distribution curve.
Results:
The RIs estimated by the proposed RII method (existing method) were as follows: CRP, 0–4.1 (0–4.7) mg/L; ESR, 0–10.2 (0–15) mm/hr and PSEP, 0–411 (0–300) pg/mL. Measurement sizes ≥2,500 showed stable results. An abnormal-to-normal value ratio of 0.5 showed the most accurate result for CRP. Adjustment values ≤5 or >5 were applicable for a measurement size <25,000 or ≥25,000, respectively.
Conclusions
The proposed RII method could provide additional information for RI verification or estimation with some limitations.
5.Three Cases of Anti-LW Antibody Identification at a Tertiary Hospital in Korea
Seungwan CHAE ; Kyoung Bo KIM ; Haein YU ; Hwa Jin CHOI ; Dong Wook JEKARL ; Jihyang LIM ; Yonggoo KIM
Korean Journal of Blood Transfusion 2022;33(1):39-45
The Landsteiner–Wiener (LW) antigen is a type of red blood cell antigen. Anti-LW appears in various situations, including alloantibodies, autoantibodies, and even transiently occurring antibodies. Anti-LW has similar characteristics to anti-D, so it can interfere with interpreting pre-transfusion tests and finding compatible blood. This paper introduces three cases in whom anti-LW was detected through antibody identification tests. All three cases were examined using the column agglutination technique with ID-DiaPanel (Bio-Rad, Hercules, CA, USA) on a LISS/Coombs card, ID-DiaPanel p (Bio-Rad) on a NaCl/Enzyme card, and ID-DiaPanel (Bio-Rad) on a LISS/Coombs card using red blood cells treated with dithiothreitol. The auto-control test, direct antiglobulin test, and umbilical cord blood test were also performed. In all three cases, the reaction with D-positive panel cells was stronger than that with the D-negative panel cells, and two of them showed a pan-agglutinated reaction in ID-DiaPanel p (Bio-Rad) with NaCl/Enzyme card. They were reported as anti-LW, and as in these cases, anti-LW can occur under a range of conditions and interfere with proper transfusion. Therefore, it is important to identify anti-LW accurately, and if anti-LW is present, the transfusion of D-negative ABO matched blood should be recommended because of the low expression of the LW-antigen. On the other hand, D-positive blood is not a contraindication when an urgent transfusion is needed.
6.Performance Evaluation of a Point of Care SelexOnTM B-Type Natriuretic Peptide Immunoassay
Dong Wook JEKARL ; Seungok LEE ; Hyunyu CHOI ; Se Woon CHO ; Hae-il PARK
Laboratory Medicine Online 2020;10(3):207-213
Background:
This study was conducted to evaluate the analytical performance of the SelexOnTM B-type natriuretic peptide (BNP) assay (Osang Healthcare Inc., Korea), a new rapid lateral flow immunoassay for point of care (POC) testing using whole blood.
Methods:
The imprecision, linearity, and method comparison of SelexOnTM BNP assay were evaluated. Two commercial BNP assays, the ADVIA Centaur® BNP (Siemens Health Care diagnostics Inc., USA) and the Triage® BNP assays (Alere, USA), were included for method comparison using 100 whole blood samples from patients. The reference interval was verified using 120 residual samples from health examination participants.
Results:
The SelexOn BNP had total CVs of 20.3%, 13.3%, and 10.3% in BNP concentrations of 89.44 pg/mL, 480.71 pg/mL, and 1,201.84 pg/mL of control materials, respectively. Linearity was observed from 56 pg/mL to 1544 pg/mL. The SelexOn BNP (y) regression equation was y=0.9706x-21.68 with Centaur BNP (x) (r=0.930) and y=0.7600x+0.0506 with Triage BNP (x) (r=0.845), respectively. The predicted mean difference (%) of the SelexOn BNP at the clinical decision levels (100 pg/mL) was up to 25% lower than the two comparative methods. The SelexOn BNP levels were below 50 pg/mL in 114 (95%) of the 120 samples.
Conclusions
The SelexOn BNP using EDTA was developed as a POC test for differential diagnosis or treatment monitoring for acute heart failure. However, clinical decision values must be improved to be compatible with other BNP methods.
7.Usefulness of Reference Change Values for Delta Check Limits in Clinical Laboratory Testing
Seungok LEE ; Jung O SON ; Hyuk KWON ; Kang Hoon PARK ; Gyong Gi YU ; Eunhee HAN ; Dong Wook JEKARL ; Yeongsic KIM
Journal of Laboratory Medicine and Quality Assurance 2020;42(3):121-129
Background:
In this study, the usefulness of within-subject biological coefficient of variation (CVI) and reference change values (RCVs) for delta check limits were investigated by comparing the population distributionbased delta check limits.
Methods:
For six tests, including aspartate aminotransferase, alanine aminotransferase, γ-glutamyl transferase, glucose, creatinine, and hemoglobin, the RCV95%, RCV99%, and RCV99.9% delta limits were obtained. The nonparametric 95% and 99% delta limits were obtained from the population distribution of the delta percentage difference of the health examination group (January 2014 to December 2018) and the outpatient and inpatient groups (January to December 2018). Delta check alerts (%) in total and all three subgroups were examined according to the five different delta check limits. Additionally, we analyzed the correlation of the median CVIF estimates with population-delta check limits for the six tests.
Results:
The delta percentage difference of the six tests showed a nonnormal distribution, and median value significantly differed among the health examination, outpatient, and inpatient groups (all, P <0.001). The overall delta check alerts of six tests decreased in the order of RCV95%, RCV99%, and RCV99.9%, population distribution -95%, and -99% delta limits; the proportion of the health examination group gradually decreased and that of inpatients increased. A good correlation was observed between median CVI (range, 2.7% to 10.1%) and population distribution delta limits (r =0.96 to 0.99).
Conclusions
The RCV delta check limits should be applied differently depending on the health and disease group. CVI can be useful for estimating the delta check limits of the population.
8.Evaluating Diagnostic Tests for Helicobacter pylori Infection Without a Reference Standard: Use of Latent Class Analysis
Dong Wook JEKARL ; Hyunyu CHOI ; Ji Yeon KIM ; Seungok LEE ; Tae Geun GWEON ; Hae Kyung LEE ; Yonggoo KIM
Annals of Laboratory Medicine 2020;40(1):68-71
Evaluation of diagnostic tests requires reference standards, which are often unavailable. Latent class analysis (LCA) can be used to evaluate diagnostic tests without reference standards, using a combination of observed and estimated results. Conditionally independent diagnostic tests for Helicobacter pylori infection are required. We used LCA to construct a reference standard and evaluate the capability of non-invasive tests (stool antigen test and serum antibody test) to diagnose H. pylori infection compared with the conventional method, where histology is the reference standard. A total of 96 healthy subjects with endoscopy histology results were enrolled from January to July 2016. Sensitivity and specificity were determined for the LCA approach (i.e., using a combination of three tests as the reference standard) and the conventional method. When LCA was used, sensitivity and specificity were 83.8% and 99.4% for histology, 80.0% and 81.9% for the stool antigen test, and 63.6% and 89.3% for the serum antibody test, respectively. When the conventional method was used, sensitivity and specificity were 75.8% and 71.1% for the stool antigen test and 77.7% and 60.7% for the serum antibody test, respectively. LCA can be applied to evaluate diagnostic tests that lack a reference standard.
9.Enumeration of CD34-positive Stem Cells Using the ADAMII Image-based Fluorescence Cell Counter
Haein YU ; Jaeeun YOO ; Jung Sil HWANG ; Mikyung KIM ; Kyung Hee BAE ; Dong Wook JEKARL ; Jong Hyun OH ; Ji Yeon LEE ; Sunmi HAN ; Chanil CHUNG ; Myungshin KIM ; Yonggoo KIM
Annals of Laboratory Medicine 2019;39(4):388-395
BACKGROUND: It is very important to accurately enumerate CD34-positive (CD34+) cells for successful hematopoietic stem cell transplantation (HSCT). We evaluated the ability of the newly developed image based-immunofluorescence cell counter ADAMII (NanoEntek, Seoul, Korea) to enumerate CD34+ cells, which was improved through simultaneous CD45 analysis. METHODS: We enumerated CD34+ cells with ADAMII using 19 peripheral blood (PB) and 91 leukapheresis samples from HSCT donors. Analytical performance, including precision and linearity, was analyzed, and sample stability during storage was evaluated. Viable CD34+ cell count (vCD34) and viable CD45+ cell count (vCD45) and the percentage of viable CD34+ cells among viable CD45+ cells (CD34/CD45) as measured by ADAMII were compared with the corresponding values from two flow cytometry assays, using regression analysis. RESULTS: ADAMII demonstrated acceptable precision, as CV values of vCD34 from six samples with different counts were all < 10% (range: 3.49–9.51%). CV values of the vCD45 and CD34/45 ranged from 4.03% to 9.67% and from 2.48% to 10.07%, respectively. The linearity of vCD34 showed an excellent R 2 value (0.99) when analyzed using the intended count and flow cytometry data. The ADAMII and two flow cytometry-based assays generated very similar data for the PB and leukapheresis samples. CONCLUSIONS: ADAMII demonstrated excellent performance for use as a routine clinical assay in terms of CD34+ cell enumeration from PB and leukapheresis samples. Moreover, it could be used as a point-of-care-test for determining mobilization time and predicting an adequate apheresis stem cell product.
Blood Component Removal
;
Cell Count
;
Flow Cytometry
;
Fluorescence
;
Hematopoietic Stem Cell Transplantation
;
Humans
;
Leukapheresis
;
Seoul
;
Stem Cells
;
Tissue Donors
10.Clinical Significance of Inflammatory Biomarkers in Acute Pediatric Diarrhea
Yoonseon PARK ; Minji SON ; Dong Wook JEKARL ; Hyun Yoo CHOI ; Sang Yong KIM ; Seungok LEE
Pediatric Gastroenterology, Hepatology & Nutrition 2019;22(4):369-376
PURPOSE: The aim of this study was to evaluate the clinical significance of inflammatory biomarkers in acute infectious diarrhea among children. METHODS: Clinical parameters including fever, bacterial and viral etiology based on stool culture and multiplex polymerase chain reaction, and nine biomarkers including C-reactive protein (CRP), erythrocyte sedimentation rate (ESR) and leukocytes in blood and calprotectin, lactoferrin, myeloperoxidase, polymorphonuclear elastase, leukocytes, and occult blood in feces were evaluated in children who were hospitalized due to acute diarrhea without underlying disease. RESULTS: A total of 62 patients were included. Among these patients, 33 had fever, 18 showed bacterial infections, and 40 patients were infected with 43 viruses. Of all the biomarkers, CRP was significantly correlated with fever (p<0.001). CRP, ESR, calprotectin, lactoferrin, myeloperoxidase, fecal leukocytes, and occult blood were significantly associated with infection with bacterial pathogens (p<0.001, p=0.04, p=0.03, p=0.003, p=0.02, p=0.03, p=0.002, respectively). The combination of CRP and fecal lactoferrin at their best cut-off values (13.7 mg/L and 22.8 µg/mL, respectively) yielded a sensitivity of 72.2%, and a specificity of 95.5% for bacterial etiology compared with their individual use. CONCLUSION: Blood CRP is a useful diagnostic marker for both fever and bacterial etiology in acute pediatric diarrhea. The combination of CRP and fecal lactoferrin yields better diagnostic capability for bacterial etiology than their use alone for acute diarrhea in children without underlying gastrointestinal disease.
Bacterial Infections
;
Biomarkers
;
Blood Sedimentation
;
C-Reactive Protein
;
Child
;
Diarrhea
;
Feces
;
Fever
;
Gastrointestinal Diseases
;
Humans
;
Lactoferrin
;
Leukocyte L1 Antigen Complex
;
Leukocytes
;
Multiplex Polymerase Chain Reaction
;
Occult Blood
;
Pancreatic Elastase
;
Peroxidase
;
Sensitivity and Specificity

Result Analysis
Print
Save
E-mail