1.Combined anterior and posterior miniscrews increase apical root resorption of maxillary incisors in protrusion and premolar extraction cases
Zhizun WANG ; Li MEI ; Zhenxing TANG ; Dong WU ; Yue ZHOU ; Ehab A. ABDULGHANI ; Yuan LI ; Wei ZHENG ; Yu LI
The Korean Journal of Orthodontics 2025;55(1):26-36
Objective:
Miniscrews are commonly utilized as temporary anchorage devices (TADs) in cases of maxillary protrusion and premolar extraction. This study aimed to investigate the effects and potential side effects of two conventional miniscrew configurations on the maxillary incisors.
Methods:
Eighty-two adult patients with maxillary dentoalveolar protrusion who had undergone bilateral first premolar extraction were retrospectively divided into three groups: non-TAD, two posterior miniscrews only (P-TADs), and two anterior and two posterior miniscrews combined (AP-TADs). Cone-beam computed tomography was used to evaluate the maxillary central incisors (U1).
Results:
The APTADs group had significantly greater U1 intrusion (1.99 ± 2.37 mm, n = 50) and less retroclination (1.70° ± 8.80°) compared to the P-TADs (–0.07 ± 1.65 mm and 9.45° ± 10.68°, n = 60) and non-TAD group (0.30 ± 1.61 mm and 1.91° ± 9.39°, n = 54).However, the AP-TADs group suffered from significantly greater apical root resorption (ARR) of U1 (2.69 ± 1.38 mm) than the P-TADs (1.63 ± 1.46 mm) and non-TAD group (0.89 ± 0.97 mm). Notably, the incidence of grade IV ARR was 16.6% in the AP-TADs group, significantly higher than the rates observed in the P-TADs (6.7%) and non-TAD (1.9%) groups. Multiple regression analysis revealed that after excluding tooth movement factors, the AP-TADs configuration resulted in an additional 0.5 mm of ARR compared with the P-TADs group.
Conclusions
In cases of maxillary protrusion and premolar extraction, the use of combined anterior and posterior miniscrews enhances incisor intrusion and minimizes torque loss of the maxillary incisors. However, this approach results in more severe ARR, likely due to the increased apical movement and composite force exerted.
2.Combined anterior and posterior miniscrews increase apical root resorption of maxillary incisors in protrusion and premolar extraction cases
Zhizun WANG ; Li MEI ; Zhenxing TANG ; Dong WU ; Yue ZHOU ; Ehab A. ABDULGHANI ; Yuan LI ; Wei ZHENG ; Yu LI
The Korean Journal of Orthodontics 2025;55(1):26-36
Objective:
Miniscrews are commonly utilized as temporary anchorage devices (TADs) in cases of maxillary protrusion and premolar extraction. This study aimed to investigate the effects and potential side effects of two conventional miniscrew configurations on the maxillary incisors.
Methods:
Eighty-two adult patients with maxillary dentoalveolar protrusion who had undergone bilateral first premolar extraction were retrospectively divided into three groups: non-TAD, two posterior miniscrews only (P-TADs), and two anterior and two posterior miniscrews combined (AP-TADs). Cone-beam computed tomography was used to evaluate the maxillary central incisors (U1).
Results:
The APTADs group had significantly greater U1 intrusion (1.99 ± 2.37 mm, n = 50) and less retroclination (1.70° ± 8.80°) compared to the P-TADs (–0.07 ± 1.65 mm and 9.45° ± 10.68°, n = 60) and non-TAD group (0.30 ± 1.61 mm and 1.91° ± 9.39°, n = 54).However, the AP-TADs group suffered from significantly greater apical root resorption (ARR) of U1 (2.69 ± 1.38 mm) than the P-TADs (1.63 ± 1.46 mm) and non-TAD group (0.89 ± 0.97 mm). Notably, the incidence of grade IV ARR was 16.6% in the AP-TADs group, significantly higher than the rates observed in the P-TADs (6.7%) and non-TAD (1.9%) groups. Multiple regression analysis revealed that after excluding tooth movement factors, the AP-TADs configuration resulted in an additional 0.5 mm of ARR compared with the P-TADs group.
Conclusions
In cases of maxillary protrusion and premolar extraction, the use of combined anterior and posterior miniscrews enhances incisor intrusion and minimizes torque loss of the maxillary incisors. However, this approach results in more severe ARR, likely due to the increased apical movement and composite force exerted.
3.Combined anterior and posterior miniscrews increase apical root resorption of maxillary incisors in protrusion and premolar extraction cases
Zhizun WANG ; Li MEI ; Zhenxing TANG ; Dong WU ; Yue ZHOU ; Ehab A. ABDULGHANI ; Yuan LI ; Wei ZHENG ; Yu LI
The Korean Journal of Orthodontics 2025;55(1):26-36
Objective:
Miniscrews are commonly utilized as temporary anchorage devices (TADs) in cases of maxillary protrusion and premolar extraction. This study aimed to investigate the effects and potential side effects of two conventional miniscrew configurations on the maxillary incisors.
Methods:
Eighty-two adult patients with maxillary dentoalveolar protrusion who had undergone bilateral first premolar extraction were retrospectively divided into three groups: non-TAD, two posterior miniscrews only (P-TADs), and two anterior and two posterior miniscrews combined (AP-TADs). Cone-beam computed tomography was used to evaluate the maxillary central incisors (U1).
Results:
The APTADs group had significantly greater U1 intrusion (1.99 ± 2.37 mm, n = 50) and less retroclination (1.70° ± 8.80°) compared to the P-TADs (–0.07 ± 1.65 mm and 9.45° ± 10.68°, n = 60) and non-TAD group (0.30 ± 1.61 mm and 1.91° ± 9.39°, n = 54).However, the AP-TADs group suffered from significantly greater apical root resorption (ARR) of U1 (2.69 ± 1.38 mm) than the P-TADs (1.63 ± 1.46 mm) and non-TAD group (0.89 ± 0.97 mm). Notably, the incidence of grade IV ARR was 16.6% in the AP-TADs group, significantly higher than the rates observed in the P-TADs (6.7%) and non-TAD (1.9%) groups. Multiple regression analysis revealed that after excluding tooth movement factors, the AP-TADs configuration resulted in an additional 0.5 mm of ARR compared with the P-TADs group.
Conclusions
In cases of maxillary protrusion and premolar extraction, the use of combined anterior and posterior miniscrews enhances incisor intrusion and minimizes torque loss of the maxillary incisors. However, this approach results in more severe ARR, likely due to the increased apical movement and composite force exerted.
4.Combined anterior and posterior miniscrews increase apical root resorption of maxillary incisors in protrusion and premolar extraction cases
Zhizun WANG ; Li MEI ; Zhenxing TANG ; Dong WU ; Yue ZHOU ; Ehab A. ABDULGHANI ; Yuan LI ; Wei ZHENG ; Yu LI
The Korean Journal of Orthodontics 2025;55(1):26-36
Objective:
Miniscrews are commonly utilized as temporary anchorage devices (TADs) in cases of maxillary protrusion and premolar extraction. This study aimed to investigate the effects and potential side effects of two conventional miniscrew configurations on the maxillary incisors.
Methods:
Eighty-two adult patients with maxillary dentoalveolar protrusion who had undergone bilateral first premolar extraction were retrospectively divided into three groups: non-TAD, two posterior miniscrews only (P-TADs), and two anterior and two posterior miniscrews combined (AP-TADs). Cone-beam computed tomography was used to evaluate the maxillary central incisors (U1).
Results:
The APTADs group had significantly greater U1 intrusion (1.99 ± 2.37 mm, n = 50) and less retroclination (1.70° ± 8.80°) compared to the P-TADs (–0.07 ± 1.65 mm and 9.45° ± 10.68°, n = 60) and non-TAD group (0.30 ± 1.61 mm and 1.91° ± 9.39°, n = 54).However, the AP-TADs group suffered from significantly greater apical root resorption (ARR) of U1 (2.69 ± 1.38 mm) than the P-TADs (1.63 ± 1.46 mm) and non-TAD group (0.89 ± 0.97 mm). Notably, the incidence of grade IV ARR was 16.6% in the AP-TADs group, significantly higher than the rates observed in the P-TADs (6.7%) and non-TAD (1.9%) groups. Multiple regression analysis revealed that after excluding tooth movement factors, the AP-TADs configuration resulted in an additional 0.5 mm of ARR compared with the P-TADs group.
Conclusions
In cases of maxillary protrusion and premolar extraction, the use of combined anterior and posterior miniscrews enhances incisor intrusion and minimizes torque loss of the maxillary incisors. However, this approach results in more severe ARR, likely due to the increased apical movement and composite force exerted.
5.Combined anterior and posterior miniscrews increase apical root resorption of maxillary incisors in protrusion and premolar extraction cases
Zhizun WANG ; Li MEI ; Zhenxing TANG ; Dong WU ; Yue ZHOU ; Ehab A. ABDULGHANI ; Yuan LI ; Wei ZHENG ; Yu LI
The Korean Journal of Orthodontics 2025;55(1):26-36
Objective:
Miniscrews are commonly utilized as temporary anchorage devices (TADs) in cases of maxillary protrusion and premolar extraction. This study aimed to investigate the effects and potential side effects of two conventional miniscrew configurations on the maxillary incisors.
Methods:
Eighty-two adult patients with maxillary dentoalveolar protrusion who had undergone bilateral first premolar extraction were retrospectively divided into three groups: non-TAD, two posterior miniscrews only (P-TADs), and two anterior and two posterior miniscrews combined (AP-TADs). Cone-beam computed tomography was used to evaluate the maxillary central incisors (U1).
Results:
The APTADs group had significantly greater U1 intrusion (1.99 ± 2.37 mm, n = 50) and less retroclination (1.70° ± 8.80°) compared to the P-TADs (–0.07 ± 1.65 mm and 9.45° ± 10.68°, n = 60) and non-TAD group (0.30 ± 1.61 mm and 1.91° ± 9.39°, n = 54).However, the AP-TADs group suffered from significantly greater apical root resorption (ARR) of U1 (2.69 ± 1.38 mm) than the P-TADs (1.63 ± 1.46 mm) and non-TAD group (0.89 ± 0.97 mm). Notably, the incidence of grade IV ARR was 16.6% in the AP-TADs group, significantly higher than the rates observed in the P-TADs (6.7%) and non-TAD (1.9%) groups. Multiple regression analysis revealed that after excluding tooth movement factors, the AP-TADs configuration resulted in an additional 0.5 mm of ARR compared with the P-TADs group.
Conclusions
In cases of maxillary protrusion and premolar extraction, the use of combined anterior and posterior miniscrews enhances incisor intrusion and minimizes torque loss of the maxillary incisors. However, this approach results in more severe ARR, likely due to the increased apical movement and composite force exerted.
6.Effect of Cinobufacini on HepG2 cells based on CXCL5/FOXD1/VEGF pathway
Xiao-Ke RAN ; Xu-Dong LIU ; Hua-Zhen PANG ; Wei-Qiang TAN ; Tie-Xiong WU ; Zhao-Quan PAN ; Yuan YUAN ; Xin-Feng LOU
Chinese Pharmacological Bulletin 2024;40(12):2361-2368
Aim To investigate the impact of Cinobu-facini on the proliferation,invasion,and apoptosis of HepG2 cells and the underlying mechanism.Methods The proliferation of HepG2 cells was assessed using the CCK-8 method following treatment with Cinobufaci-ni.The invasion capability of HepG2 cells was evalua-ted through Transwell assay after exposure to Cinobufa-cini.The apoptosis rates of HepG2 cells post Cinobufa-cini intervention were measured using flow cytometry,and the expression levels of VEGF in the culture medi-um of HepG2 cells were determined using enzyme-linked immunoassay.Furthermore,qRT-PCR and Western blot analyses were conducted to assess the im-pact of Cinobufacini on mRNA and protein expression levels related to the CXCL5/FOXD1/VEGF pathway.The interaction between CXCL5 and FOXD1 was inves-tigated via co-immunoprecipitation.Results Cinobufa-cini treatment led to a gradual decrease in HepG2 cell viability in a dose-dependent manner compared to the control group(P<0.05).Moreover,Cinobufacini sig-nificantly suppressed HepG2 cell invasion(P<0.05)while enhancing cell apoptosis(P<0.05).Notably,Cinobufacini exhibited inhibitory effects on the CX-CL5/FOXD1/VEGF pathway,as evidenced by re-duced expression of related mRNA and proteins(P<0.05).FOXD1 was identified as the binding site of CXCL5.Overexpression of CXCL5 resulted in in-creased proliferation and VEGF secretion by HepG2 cells(P<0.05),and increased expression of FOXD1 and VEGF(P<0.05).However,Cinobufacini inter-vention effectively inhibited liver cancer cell prolifera-tion and invasion(P<0.05),promoted apoptosis(P<0.05),reduced VEGF secretion by HepG2 cells(P<0.05),and downregulated the expression of CXCL5 and FOXD1 in HepG2 cells(P<0.05);but com-pared with the unexpressed group of Cinobufacini,its ability to inhibit cell activity was weakened(P<0.05),and its ability to inhibit the expression of CX-CL5,FOXD1,and VEGF was weakened(P<0.05).Conclusion Cinobufacini may inhibit HepG2 cell pro-liferation and invasion and promote HepG2 cell apopto-sis by regulating the CXCL5/FOXD1/VEGF pathway.
7.Correlation between femoral offset,rotation center and leg length discrepancy after total hip arthroplasty based on digital analysis
Mao-Yong LI ; Wei CAO ; Pei-Xin SHA ; Xu-Dong SUN ; Shi-Yuan HUANG ; Kuan-Xin LI ; Heng ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(4):381-386
Objective CT scans combined with Mimics software were used to measure femoral offset(FO),rotation center height(RCH)and lower leg length discrepancy(LLD)following total hip arthroplasty(THA),and the relationship between FO,RCH and LLD after THA is discussed.Methods Retrospective analysis was performed on 40 patients with unilateral THA who met standard cases from October 2020 to June 2022.There were 21 males and 19 females,18 patients on the left side and 22 patients on the right side,aged range from 30 to 81 years old,with an average age of(58.90±14.13)years old,BMI ranged from 17.3 to 31.5 kg·m-2withan average of(25.3±3.4)kg·m-2.There were 30 cases of femoral head necrosis(Ficattype Ⅳ),2 cases of hip osteoarthritis(Tonnis type Ⅲ),2 cases of developmental hip dislocation combined with end-stage osteoarthritis(Crowe type Ⅲ),and 6 cases of femoral neck fracture(Garden type Ⅳ).Three-dimensional CT reconstruction of pelvis was taken preoperative and postoperative,and three-dimensional reconstruction model was established after processing by Mimics software.FO,RCH and LLD were measured on the model.The criteria for FO reconstruction were as follows:postoperative bi-lateral FO difference less than 5 mm;the standard for equal length of both lower limbs was as follows:postoperative LLD differ-ence less than 5 mm.Results Bilateral FO difference was positively correlated with LLD(r=0.744,P<0.00l).Chi-square test was performed between the FO reconstructed group and the non-reconstructed eccentricity group:The results showed that the i-sometric ratio of lower limbs in the FO reconstructed group was significantly higher than that in the FO reconstructed group(x2=6.320,P=0.012).The bilateral RCH difference was significantly negatively correlated with LLD(r=-0.877,P<0.001).There is a linear relationship between bilateral FO difference and bilateral RCH difference and postoperative LLD,and the lin-ear regression equation is satisfied:postoperative LLD=0.038x-0.099y+0.257(x:postoperative bilateral FO difference,y:post-operative bilateral RCH difference;Unit:cm),F=77.993,R2=0.808,P=0.009.Conclusion After THA,LLD increased with the increase of FO and decreased with the increase of RCH.The effect of lower limb isometric length can be obtained more easily by reconstruction of FO.There is a linear relationship between the bilateral FO difference and the bilateral RCH difference after THA and LLD,and the regression equation can provide a theoretical reference forjudging LLD.
8.3D printing navigation template assisted pedicle screw placement for the treatment of type Ⅱ old odontoid fractures
Wei-Xin DONG ; Zhen-Tao CHU ; Yong HU ; Ou-Jie LAI ; Zhen-Shan YUAN
China Journal of Orthopaedics and Traumatology 2024;37(8):779-785
Objective To compare the safety and clinical efficacy of freehand and 3D printing navigation template assisted screw placement in patients with old odontoid fractures of type Ⅱ.Methods Total of 38 patients with old odontoid fractures of type Ⅱ were treated from November 2018 to December 2022,all of which presented as chronic neck pain.According to the dif-ferent methods of screw insertion into the pedicle,the patients were divided into a navigation template group and a freehand group.In the navigation template group,there were 17 patients including 9 males and 8 females with an average age of(51.30±13.20)years old,disease duration was(22.18±7.59)months.In the freehand group,there 21 patients including 7 males and 14 females with an average age of(49.46±11.92)years old,disease duration was(19.52±9.17)months.The intraoperative blood loss,operation time,and postoperative drainage output were recorded and compared between two groups.The accuracy of screw placement was evaluated by CT scan.Before operation and 1 year after operation,cervical pain was assessed by visual analogue scale(VAS),neurological changes were evaluated by the Japanese Orthopaedic Association(JOA)score,and the de-gree of spinal cord injury was assessed by the American Spinal Injury Association(ASIA)injury scale.Results All patients were followed up for(25.31±1.21)months.The operation time of template group(112.00±20.48)min had significantly shorter than that of the freehand group(124.29±15.24)min(P<0.05),while there were no significant differences between two groups in terms of intraoperative blood loss,postoperative drainage,and hospital stay(P>0.05).At 1 year after operation,in template group and freehand group,the VAS[(2.88±0.86),(2.90±0.83)]and JOA[(14.94±1.82),(14.62±2.19)]improved with pre-operative[VAS(4.71±0.92),(4.86±0.79)and JOA(12.18±2.30),(11.95±2.31)](P<0.05),with no significant difference between two groups(P>0.05).No significant improvement was observed in ASIA grading in either group at 1 year after opera-tion(P>0.05),and there was no significant difference between two groups(P>0.05).The template group had significantly better accuracy of screw placement in the pedicle of the axis than the freehand group(P<0.05),while no significant difference was observed between two groups in the accuracy of screw placement in the pedicle of the atlas(P>0.05).Conclusion In the treat-ment of type Ⅱ old odontoid fractures with posterior pedicle screw fixation,3D printing navigation template screw placement can significantly shorten the operation time,achieve similar clinical efficacy as free-hand screw placement,and significantly im-prove the accuracy of screw placement in the pedicle of the axis.
9.AI-HIP system for prosthesis size,global femoral offset and osteotomy in total hip arthroplasty
Guo-Yuan SUN ; Yan-Kun JIANG ; Tong LI ; Xue-Feng CONG ; Cheng HUANG ; Ran DING ; Wei-Guo WANG ; Qi-Dong ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(9):848-854
Objective To explore planning effect of AI-HIP assisted surgical planning system in primary unilateral total hip arthroplasty(THA)and its influence on clinical outcomes.Methods A retrospective analysis was conducted on clinical data of 36 patients who underwent their first unilateral THA from March 2022 to November 2022 and continuously used AI-HIP system(AI-HIP group),including 16 males and 20 females,aged from 43 to 81 years old with an average of(62.2±10.9)years old.According to the matching principle,36 patients who were planned by the traditional template method at the same period were selected as the control group,including 16 males and 20 females,aged from 40 to 80 years old with an average of(60.9±12.1)years old.The accuracy between two groups of prostheses were compared,as well as the combined eccentricity difference between preoperative planning and postoperative practice,lower limb length difference,osteotomy height from the upper edge of the lesser trochanter and top shoulder distance to evaluate planning effect.Harris score and visual analogue scale(VAS)were used to evaluate clinical efficacy.Results Both groups were followed up for 12 to 18 months with an average of(14.5±2.1)months.The complete accuracy and approximate accuracy of acetabular cup and femoral stalk prosthesis in AI-HIP group were 72.2%,100%,58.3%,88.9%,respectively,which were better than 44.4%,83.3%,33.3%,66.7%in control group(P<0.05).There was no statistical significance in planning of femoral head prosthesis size(P>0.05).The actual combined eccentricity difference and combined eccentricity difference(practical-planning)in Al-HIP group were 1.0(0.2,2.4)mm and 1.1(-2.1,3.2)mm,respectively;which were better than 3.0(1.4,4.9)mm and 3.5(-1.6,6.5)mm in control group(P<0.05).There was no significant difference between two groups in actual osteotomy height of the upper margin of the lesser trochanter(P>0.05).In AI-HIP group,the actual difference of lower extremity length after surgery,the difference of lower extremity length(practical-planning),osteotomy height from the upper margin of lesser trochanter(practical-planning),actual topshoulder distance after surgery,and topshoulder distance(practical-planning)were 1.5(0.2,2.8),1.1(-0.3,2.2),2.1(-2.3,4.1),(15.3±4.1),2.2(-4.8,0.3)mm,respectively;which were better than control group of 2.6(1.3,4.1),2.5(0.3,3.8),5.8(-2.4,7.7),(13.0±4.3),-5.7(-9.4,-2.2)mm(P<0.05).At final follow-up,there were no significant differences in Harris scores of pain,function,deformity,total scores and VAS between two groups(P>0.05).The range of motion score was 4.8±0.6 in AI-HIP group,which was higher than that in control group(4.4±0.8)(P<0.05).Conclusion Compared with traditional template planning,AI-HIP assisted surgical planning system has good accuracy in predicting the prosthetic size of the acetabular cup and femoral stalk,restor-ing joint eccentricity,planning lower limb length,osteotomy height and top shoulder distance on the first unilateral THA,and the clinical follow-up effect is satisfactory.
10.Predictive value of serum sFlt-1 and LTB4 for cerebral vasospasm after interventional embolization of intracranial aneurysms
Bing CAO ; Qi DING ; Yong-Da LIU ; Zhi-Wei DONG ; Yuan HOU ; Chun-Jiang LIU ; Xin-Wen XU
Journal of Regional Anatomy and Operative Surgery 2024;33(12):1062-1066
Objective To explore the predictive value of soluble fms-like tyrosine kinase-1(sFlt-1)and leukotriene B4(LTB4)in patients with intracranial aneurysms for cerebral vasospasm(CVS)after interventional embolization.Methods A total of 98 patients with intracranial aneurysms admitted to our hospital from January 2019 to September 2023 were regarded as the observation group,and were divided into the CVS group(32 cases)and the non CVS group(66 cases)according to whether CVS occurred or not within 3 to 5 days after surgery;102 healthy examinees in our hospital were selected as the control group.Enzyme-linked immunosorbent assay was used to detect serum levels of sFlt-1 and LTB4;the influencing factors for CVS after interventional embolization of intracranial aneurysms were analyzed by Logistic regression analysis;the predictive value of serum sFlt-1 and LTB4 levels for the occurrence of CVS after interventional embolization of intracranial aneurysms was analyzed by receiver operating characteristic(ROC)curve.Results The serum levels of sFlt-1 and LTB4 of patients in the observation group were obviously higher than those in the control group,and the differences were statistically significant(P<0.05).The serum levels of sFlt-1 and LTB4,and the proportions of patients with postoperative blood pressure fluctuation range≥30 mmHg and Hunt-Hess grade Ⅲ in the CVS group were obviously higher than those in the non CVS group,and the differences were statistically significant(P<0.05).SFlt-1(OR:2.985;95%CI:1.684 to 5.291)and LTB4(OR:2.868;95%CI:1.581 to 5.204)were the independent risk factors for CVS after interventional embolization of intracranial aneurysms(P<0.05).The area under the curve(AUC)of sFlt-1 and LTB4 alone and in combination for predicting the occurrence of CVS after interventional embolization of intracranial aneurysms were 0.839,0.825,and 0.915,respectively,with sensitivity of 84.44%,87.59%,and 81.36%,and specificity of 74.26%,75.87%,and 90.98%,respectively.The AUC of the combination of the two was higher than those of sFlt-1 and LTB4 alone,and the differences were statistically significant(Z=2.150,2.546,P<0.05).Conclusion The serum levels of sFlt-1 and LTB4 in patients with CVS after interventional embolization of intracranial aneurysms are increased,and the combination of the two can serve as the important indicators for predicting CVS.

Result Analysis
Print
Save
E-mail