1.Structured Integration of an Artificial Intelligence-Based System for the Optical Diagnosis of Colorectal Polyps
Hae Yeon KANG ; Soonwhan KANG ; Goh Eun CHUNG ; Dong Hoon BAEK ; Hong Sub LEE ; Jinbae PARK ; Sun Young YANG ; Seon Hee LIM ; Ji Min CHOI ; Jung KIM ; Jung Ho BAE
Gut and Liver 2026;20(1):86-96
Background/Aims:
Recent advances in computer-aided diagnosis (CADx) systems have demonstrated expert-level accuracy in the optical diagnosis of colorectal polyps. High-confidence (HC) diagnoses have been defined as those made within 3 seconds without hesitation, and these systems have been shown to improve diagnostic accuracy. We aimed to evaluate the performance of endoscopists with varying levels of experience in diagnosing colorectal polyps with the assistance of a new CADx system applying the 3-second rule and without artificial intelligence assistance.
Methods:
In this multicenter ex vivo study, 35 endoscopists assessed 100 polyps (51 adenomas, 39 hyperplastic polyps, 10 sessile serrated lesions) using narrow-band imaging video clips on an online platform. Assessments consisted of individual endoscopist diagnosis and CADx-assisted diagnosis. HC assignments followed the 3-second rule in both phases. Performance metrics included HC accuracy, HC rate, and adherence to the Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) and Simple Optical Diagnosis Accuracy (SODA) thresholds.
Results:
HC diagnostic accuracy improved from 78.3% (95% confidence interval [CI], 76.6% to 80.0%) to 89.8% (95% CI, 88.6% to 90.9%) with CADx assistance (p<0.001). The proportion of HC predictions increased from 64.2% to 75.4% (p<0.001). Novice endoscopists showed marked improvement with CADx (74.1% vs 88.8%; p<0.001). CADx-assisted diagnoses nearly met SODA and PIVI thresholds under the 3-second rule. Additional analysis demonstrated that CADx assistance significantly improved interobserver agreement and ground truth, particularly for novices (κ=0.37 to κ=0.65; p<0.001).
Conclusions
Integrating CADx with the 3-second rule significantly enhances the performance of endoscopists in the optical diagnosis of colorectal polyps, with the greatest benefit observed among novice endoscopists.
2.2025 Seoul Consensus on Clinical Practice Guidelines for Irritable Bowel Syndrome
Yonghoon CHOI ; Young Hoon YOUN ; Seung Joo KANG ; Jeong Eun SHIN ; Young Sin CHO ; Yoon Suk JUNG ; Seung Yong SHIN ; Cheal Wung HUH ; Yoo Jin LEE ; Hoon Sup KOO ; Kwangwoo NAM ; Hong Sub LEE ; Dong Hyun KIM ; Ye Hyun PARK ; Min Cheol KIM ; Hyo Yeop SONG ; Sung-Hoon YOON ; Sang Yeol LEE ; Miyoung CHOI ; Moo-In PARK ; In-Kyung SUNG ;
Journal of Neurogastroenterology and Motility 2025;31(2):133-169
Irritable bowel syndrome (IBS) is a chronic, disabling, and functional bowel disorder that significantly affects social functioning and reduces quality of life and increases social costs. The Korean Society of Neurogastroenterology and Motility published clinical practice guidelines on the management of IBS based on a systematic review of the literature in 2017, and planned to revise these guidelines in light of new evidence on the pathophysiology, diagnosis, and management of IBS. The current revised version of the guidelines is consistent with the previous version and targets adults diagnosed with or suspected of having IBS. These guidelines were developed using a combination of de novo and adaptation methods, with analyses of existing guidelines and discussions within the committee, leading to the identification of key clinical questions. Finally, the guidelines consisted of 22 recommendations, including 3 concerning the definition and risk factors of IBS, 4 regarding diagnostic modalities and strategies, 2 regarding general management, and 13 regarding medical treatment. For each statement, the advantages, disadvantages, and precautions were thoroughly detailed. The modified Delphi method was used to achieve expert consensus to adopt the core recommendations of the guidelines. These guidelines serve as a reference for clinicians (including primary care physicians, general healthcare providers, medical students, residents, and other healthcare professionals) and patients, helping them to make informed decisions regarding IBS management.
3.2025 Seoul Consensus on Clinical Practice Guidelines for Irritable Bowel Syndrome
Yonghoon CHOI ; Young Hoon YOUN ; Seung Joo KANG ; Jeong Eun SHIN ; Young Sin CHO ; Yoon Suk JUNG ; Seung Yong SHIN ; Cheal Wung HUH ; Yoo Jin LEE ; Hoon Sup KOO ; Kwangwoo NAM ; Hong Sub LEE ; Dong Hyun KIM ; Ye Hyun PARK ; Min Cheol KIM ; Hyo Yeop SONG ; Sung-Hoon YOON ; Sang Yeol LEE ; Miyoung CHOI ; Moo-In PARK ; In-Kyung SUNG ;
Journal of Neurogastroenterology and Motility 2025;31(2):133-169
Irritable bowel syndrome (IBS) is a chronic, disabling, and functional bowel disorder that significantly affects social functioning and reduces quality of life and increases social costs. The Korean Society of Neurogastroenterology and Motility published clinical practice guidelines on the management of IBS based on a systematic review of the literature in 2017, and planned to revise these guidelines in light of new evidence on the pathophysiology, diagnosis, and management of IBS. The current revised version of the guidelines is consistent with the previous version and targets adults diagnosed with or suspected of having IBS. These guidelines were developed using a combination of de novo and adaptation methods, with analyses of existing guidelines and discussions within the committee, leading to the identification of key clinical questions. Finally, the guidelines consisted of 22 recommendations, including 3 concerning the definition and risk factors of IBS, 4 regarding diagnostic modalities and strategies, 2 regarding general management, and 13 regarding medical treatment. For each statement, the advantages, disadvantages, and precautions were thoroughly detailed. The modified Delphi method was used to achieve expert consensus to adopt the core recommendations of the guidelines. These guidelines serve as a reference for clinicians (including primary care physicians, general healthcare providers, medical students, residents, and other healthcare professionals) and patients, helping them to make informed decisions regarding IBS management.
4.2025 Seoul Consensus on Clinical Practice Guidelines for Irritable Bowel Syndrome
Yonghoon CHOI ; Young Hoon YOUN ; Seung Joo KANG ; Jeong Eun SHIN ; Young Sin CHO ; Yoon Suk JUNG ; Seung Yong SHIN ; Cheal Wung HUH ; Yoo Jin LEE ; Hoon Sup KOO ; Kwangwoo NAM ; Hong Sub LEE ; Dong Hyun KIM ; Ye Hyun PARK ; Min Cheol KIM ; Hyo Yeop SONG ; Sung-Hoon YOON ; Sang Yeol LEE ; Miyoung CHOI ; Moo-In PARK ; In-Kyung SUNG ;
Journal of Neurogastroenterology and Motility 2025;31(2):133-169
Irritable bowel syndrome (IBS) is a chronic, disabling, and functional bowel disorder that significantly affects social functioning and reduces quality of life and increases social costs. The Korean Society of Neurogastroenterology and Motility published clinical practice guidelines on the management of IBS based on a systematic review of the literature in 2017, and planned to revise these guidelines in light of new evidence on the pathophysiology, diagnosis, and management of IBS. The current revised version of the guidelines is consistent with the previous version and targets adults diagnosed with or suspected of having IBS. These guidelines were developed using a combination of de novo and adaptation methods, with analyses of existing guidelines and discussions within the committee, leading to the identification of key clinical questions. Finally, the guidelines consisted of 22 recommendations, including 3 concerning the definition and risk factors of IBS, 4 regarding diagnostic modalities and strategies, 2 regarding general management, and 13 regarding medical treatment. For each statement, the advantages, disadvantages, and precautions were thoroughly detailed. The modified Delphi method was used to achieve expert consensus to adopt the core recommendations of the guidelines. These guidelines serve as a reference for clinicians (including primary care physicians, general healthcare providers, medical students, residents, and other healthcare professionals) and patients, helping them to make informed decisions regarding IBS management.
5.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
6.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
7.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
8.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
9.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
10.Comparison of Korean Body Image Questionnaires in Adolescent Idiopathic Scoliosis
Il-Soo EUN ; Tae Sik GOH ; Dong Suk KIM ; Minjun CHOI ; Jung Sub LEE
Asian Spine Journal 2023;17(1):47-60
Methods:
Adolescent idiopathic scoliosis (AIS) patients ages 10 to 19 years completed the Korean version of the Quality of Life Profile for Spinal Deformities (K-QLPSD), the Scoliosis Research Society-22 self-image subscale (K-SRS-22-si), Korean version of the Spinal Appearance Questionnaire (K-SAQ), Korean version of the Body Image Disturbance Questionnaire-Scoliosis (K-BIDQ-S), and Korean version of the Italian Spine Youth Quality of Life (K-ISYQOL). Four body image questionnaires were compared with K-ISYQOL and radiographic major curve magnitude, coronal balance, and sagittal balance. Spearman’s correlation was performed to compare the four body image questionnaires.
Results:
The study included 84 AIS patients, with a mean age of 12.6 years and a major Cobb angle of 29.4°. The four surveys were correlated with major curve magnitude and K-ISYQOL. K-SAQ and K-BIDQ-S were correlated better than K-QLPSD, and K-SRS-22-si was correlated with K-ISYQOL. The four surveys were moderately correlated with major curve magnitude, but there was no correlation with age, coronal balance, and sagittal balance.
Conclusions
K-SAQ and K-BIDQ-S correlate better with K-ISYQOL than K-QLPSD and K-SRS-22-si.

Result Analysis
Print
Save
E-mail