1.Anterior Segment Swept-Source Optical Coherence Tomography–based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative Study
Dong Hee HA ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2025;39(2):103-113
Purpose:
To analyze anterior, posterior, and total corneal refractive profiles and thickness using anterior segment (AS) sweptsource optical coherence tomography (SS-OCT) in Stevens-Johnson syndrome (SJS) or toxic epidermal necrolysis (TEN) patients.
Methods:
This retrospective study compared 23 eyes from 14 patients with SJS/TEN with 23 eyes from 14 age- and sexmatched controls. AS SS-OCT measured corneal refractive profiles and pachymetry. Parameters included anterior, posterior, and total corneal power values, posterior to anterior curvature ratio, maximal corneal power, and thickness profiles. The SJS/TEN group was subdivided based on corneal opacity presence (subgroup A) or absence (subgroup B).
Results:
The SJS/TEN group showed significantly higher corneal astigmatism and maximal corneal power values for both anterior and posterior curvatures. Steep total corneal power and total corneal astigmatism were higher in the SJS/TEN group. The thinnest corneal thickness was lower, and its distance from the corneal vertex was greater in the SJS/TEN group. Subgroup analysis revealed that these differences were primarily attributed to the presence of corneal opacity. Additionally, automated keratometry of the anterior corneal surface showed significantly higher values, including steep, flat, and average keratometry and corneal astigmatism, in the SJS/TEN group.
Conclusions
AS SS-OCT shows significant alterations in both anterior and posterior corneal curvatures in patients with SJS/TEN. These findings emphasize the importance of considering posterior corneal curvature changes in pre-cataract surgery assessments and contact lens prescriptions for patients with SJS/TEN.
2.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
3.Liver Cirrhosis Progression in a Patient with Overlapping IgG4-Related Sclerosing Cholangitis and Primary Biliary Cholangitis
Dong Wook KIM ; Hee Yoon NOH ; Song-Hee HAN ; Myung Hwan NOH
Korean Journal of Pancreas and Biliary Tract 2025;30(2):87-92
We report a rare case of overlapping immunoglobulin G4-sclerosing cholangitis (IgG4-SC) and primary biliary cholangitis (PBC) in a 78-year-old woman presenting with sudden-onset jaundice, cholestatic liver enzyme elevation, and biliary strictures. Elevated alkaline phosphatase levels, positive antimitochondrial antibodies, increased serum IgG4 levels, and a high IgG4/IgG ratio, combined with endobiliary biopsy via endoscopic retrograde cholangiopancreatography biopsy showing lymphoplasmacytic infiltration and IgG4-positive cells, confirmed the diagnosis. Initial treatment with biliary drainage, ursodeoxycholic acid (UDCA), and corticosteroids provided temporary relief; however, the patient experienced recurrent episodes of cholangitis and biliary obstruction, eventually progressing to decompensated cirrhosis over 2 years. This case highlights the importance of considering IgG4-SC in patients with PBC who fail to respond adequately to UDCA and underscores the significant challenges in diagnosing and managing such overlapping syndromes. Further research is crucial to better understand the underlying pathophysiology, refine therapeutic strategies, and improve clinical outcomes of these rare, complex autoimmune conditions.
4.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
5.Differences in Treatment Outcomes Depending on the Adjuvant Treatment Modality in Craniopharyngioma
Byung Min LEE ; Jaeho CHO ; Dong-Seok KIM ; Jong Hee CHANG ; Seok-Gu KANG ; Eui-Hyun KIM ; Ju Hyung MOON ; Sung Soo AHN ; Yae Won PARK ; Chang-Ok SUH ; Hong In YOON
Yonsei Medical Journal 2025;66(3):141-150
Purpose:
Adjuvant treatment for craniopharyngioma after surgery is controversial. Adjuvant external beam radiation therapy (EBRT) can increase the risk of long-term sequelae. Stereotactic radiosurgery (SRS) is used to reduce treatment-related toxicity.In this study, we compared the treatment outcomes and toxicities of adjuvant therapies for craniopharyngioma.
Materials and Methods:
We analyzed patients who underwent craniopharyngioma tumor removal between 2000 and 2017. Of the 153 patients, 27 and 20 received adjuvant fractionated EBRT and SRS, respectively. We compared the local control (LC), progression-free survival (PFS), and overall survival between groups that received adjuvant fractionated EBRT, SRS, and surveillance.
Results:
The median follow-up period was 77.7 months. For SRS and surveillance, the 10-year LC was 57.2% and 57.4%, respectively. No local progression was observed after adjuvant fractionated EBRT. One patient in the adjuvant fractionated EBRT group died owing to glioma 94 months after receiving radiotherapy (10-year PFS: 80%). The 10-year PFS was 43.6% and 50.7% in the SRS and surveillance groups, respectively. The treatment outcomes significantly differed according to adjuvant treatment in nongross total resection (GTR) patients. Additional treatment-related toxicity was comparable in the adjuvant fractionated EBRT and other groups.
Conclusion
Adjuvant fractionated EBRT could be effective in controlling local failure, especially in patients with non-GTR, while maintaining acceptable treatment-related toxicity.
6.Anterior Segment Swept-Source Optical Coherence Tomography–based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative Study
Dong Hee HA ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2025;39(2):103-113
Purpose:
To analyze anterior, posterior, and total corneal refractive profiles and thickness using anterior segment (AS) sweptsource optical coherence tomography (SS-OCT) in Stevens-Johnson syndrome (SJS) or toxic epidermal necrolysis (TEN) patients.
Methods:
This retrospective study compared 23 eyes from 14 patients with SJS/TEN with 23 eyes from 14 age- and sexmatched controls. AS SS-OCT measured corneal refractive profiles and pachymetry. Parameters included anterior, posterior, and total corneal power values, posterior to anterior curvature ratio, maximal corneal power, and thickness profiles. The SJS/TEN group was subdivided based on corneal opacity presence (subgroup A) or absence (subgroup B).
Results:
The SJS/TEN group showed significantly higher corneal astigmatism and maximal corneal power values for both anterior and posterior curvatures. Steep total corneal power and total corneal astigmatism were higher in the SJS/TEN group. The thinnest corneal thickness was lower, and its distance from the corneal vertex was greater in the SJS/TEN group. Subgroup analysis revealed that these differences were primarily attributed to the presence of corneal opacity. Additionally, automated keratometry of the anterior corneal surface showed significantly higher values, including steep, flat, and average keratometry and corneal astigmatism, in the SJS/TEN group.
Conclusions
AS SS-OCT shows significant alterations in both anterior and posterior corneal curvatures in patients with SJS/TEN. These findings emphasize the importance of considering posterior corneal curvature changes in pre-cataract surgery assessments and contact lens prescriptions for patients with SJS/TEN.
7.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
8.Liver Cirrhosis Progression in a Patient with Overlapping IgG4-Related Sclerosing Cholangitis and Primary Biliary Cholangitis
Dong Wook KIM ; Hee Yoon NOH ; Song-Hee HAN ; Myung Hwan NOH
Korean Journal of Pancreas and Biliary Tract 2025;30(2):87-92
We report a rare case of overlapping immunoglobulin G4-sclerosing cholangitis (IgG4-SC) and primary biliary cholangitis (PBC) in a 78-year-old woman presenting with sudden-onset jaundice, cholestatic liver enzyme elevation, and biliary strictures. Elevated alkaline phosphatase levels, positive antimitochondrial antibodies, increased serum IgG4 levels, and a high IgG4/IgG ratio, combined with endobiliary biopsy via endoscopic retrograde cholangiopancreatography biopsy showing lymphoplasmacytic infiltration and IgG4-positive cells, confirmed the diagnosis. Initial treatment with biliary drainage, ursodeoxycholic acid (UDCA), and corticosteroids provided temporary relief; however, the patient experienced recurrent episodes of cholangitis and biliary obstruction, eventually progressing to decompensated cirrhosis over 2 years. This case highlights the importance of considering IgG4-SC in patients with PBC who fail to respond adequately to UDCA and underscores the significant challenges in diagnosing and managing such overlapping syndromes. Further research is crucial to better understand the underlying pathophysiology, refine therapeutic strategies, and improve clinical outcomes of these rare, complex autoimmune conditions.
9.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
10.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.

Result Analysis
Print
Save
E-mail