1.Antibacterial effect of low-temperature plasma on Enterococcus faecalis in dentinal tubules in vitro.
Ruo Qing ZHONG ; Meng Qian ZHU ; Ying Long LI ; Ji PAN
Journal of Peking University(Health Sciences) 2023;55(1):38-43
OBJECTIVE:
To construct a model of Enterococcus faecalis (E. faecalis) infection in dentinal tubules by gradient centrifugation and to evaluate the antibacterial effect of low-temperature plasma on E. faecalis in dentinal tubules.
METHODS:
Standard dentin blocks of 4 mm×4 mm×2 mm size were prepared from single root canal isolated teeth without caries, placed in the E. faecalis bacterial solution, centrifuged in gradient and incubated for 24 h to establish the model of dentinal tubule infection with E. faecalis. The twenty dentin blocks of were divided into five groups, low-temperature plasma jet treatment for 0, 5 and 10 min, calcium hydroxide paste sealing for 7 d and 2% chlorhexidine gel sealing for 7 d. Scanning electron microscopy and confocal laser scanning microscope were used to assess the infection in the dentinal tubules and the antibacterial effect of low-temperature plasma.
RESULTS:
The results of scanning electron microscopy and confocal laser scanning microscopy showed that after 24 h of incubation by gradient centrifugation, E. faecalis could fully enter the dentinal tubules to a depth of more than 600μm indicating that this method was time-saving and efficient and could successfully construct a model of E. faecalis infection in dentinal tubules. Low-temperature plasma could enter the dentinal tubules and play a role, the structure of E. faecalis was still intact after 5 min of low-temperature plasma treatment, with no obvious damage, and after 10 min of low-temperature plasma treatment, the surface morphology of E. faecalis was crumpled and deformed, the cell wall was seriously collapsed, and the normal physiological morphology was damaged indicating that the majority of E. faecalis was killed in the dentinal tubules. The antibacterial effect of low-temperature plasma treatment for 10 min exceeded that of the calcium hydroxide paste sealing for 7 d and the 2% chlorhexidine gel sealing for 7 d. These two chemicals had difficulty entering deep into the dentinal tubules, and therefore only had a few of antibacterial effect on the bacterial biofilm on the root canal wall, and there was also no significant damage to the E. faecalis bacterial structure.
CONCLUSION
Gradient centrifugation could establish the model of E. faecalis dentin infection successfully. Low-temperature plasma treatment for 10 min could kill E. faecalis in dentinal tubules effectively, which is superior to the calcium hydroxide paste sealing for 7 d and the 2% chlorhexidine gel sealing for 7 d.
Chlorhexidine/pharmacology*
;
Calcium Hydroxide/pharmacology*
;
Enterococcus faecalis/physiology*
;
Temperature
;
Dentin
;
Biofilms
;
Anti-Bacterial Agents/pharmacology*
;
Root Canal Irrigants/pharmacology*
;
Dental Pulp Cavity
2.On-Site Assessment of a Cryogenic Disinfectant for the Alpine Environment and Outer Packaging of Frozen Items.
Jin SHEN ; Bin YANG ; Jia Qing XIAO ; Lu Yao LI ; Hui Hui SUN ; Hong Yang DUAN ; Wei ZHANG ; Chen LIANG ; Lu CHEN ; Li LI ; Yan Yan CHEN ; Yuan LYU ; Song TANG ; Jiao WANG ; Liu Bo ZHANG ; Lin WANG
Biomedical and Environmental Sciences 2023;36(2):174-184
OBJECTIVE:
To study the effectiveness and feasibility of cryogenic disinfectants in different cold scenarios and analyze the key points of on-site cryogenic disinfection.
METHODS:
Qingdao and Suifenhe were selected as application sites for the manual or mechanical spraying of cryogenic disinfectants. The same amount of disinfectant (3,000 mg/L) was applied on cold chain food packaging, cold chain containers, transport vehicles, alpine environments, and article surfaces. The killing log value of the cryogenic disinfectant against the indicator microorganisms ( Staphylococcus aureus and Escherichia coli) was used to evaluate the on-site disinfection effect.
RESULTS:
When using 3,000 mg/L with an action time of 10 min on the ground in alpine regions, the surface of frozen items, cold-chain containers, and cold chain food packaging in supermarkets, all external surfaces were successfully disinfected, with a pass rate of 100%. The disinfection pass rates for cold chain food packaging and cold chain transport vehicles of centralized supervised warehouses and food processing enterprises were 12.5% (15/120), 81.67% (49/60), and 93.33% (14/15), respectively; yet, the surfaces were not fully sprayed.
CONCLUSION
Cryogenic disinfectants are effective in disinfecting alpine environments and the outer packaging of frozen items. The application of cryogenic disinfectants should be regulated to ensure that they cover all surfaces of the disinfected object, thus ensuring effective cryogenic disinfection.
Humans
;
Disinfectants/pharmacology*
;
Disinfection
;
Escherichia coli
;
Staphylococcal Infections
;
Staphylococcus aureus
3.Effectiveness of three auxiliary irrigation methods for cleaning the internal walls of root canals of curved isolated teeth.
Chaoying WEN ; Wenxin ZUO ; Wen LUO ; Fei HE
West China Journal of Stomatology 2023;41(5):554-562
OBJECTIVES:
This study aimed to compare the effectiveness of ultrasound and acoustic and laser cleaning of curved root canals.
METHODS:
A total of 92 molars with independent root canals with a curvature of 20°-40° were prepared and standardized at 04 25# and stained with gentian violet solution for 72 h. Among them, 52 were randomly divi-ded into four groups for final rinsing (n=13): NI group, PUI group, EDDY group, and PIPS group. Ten samples in each group were cut horizontally along the long axis perpendicular to the root and divided into curved upper, curved, and apical segments. Images were taken with a stereomicroscope and Image J measurements were taken to calculate the depth of rinse penetration. The remaining three samples from each group were split along the long axis of the dentin, photographed by scanning electron microscope to record the dentin tubule exposure and staining layer, and scored for staining layer by double-blind method. SPSS 26.0 software was used to perform statistical analysis and select the best flushing method. An extra 40 samples were randomly divided into four groups for detection of flushing fluid penetration depth (n=10): 10, 20, 30, and 40 s.
RESULTS:
In the upper part, the mean depth of infiltration was not significantly different between the experimental and control groups (P>0.05). The PIPS group had a significantly lower smear layer score than the control group and the EDDY group (P<0.01). In the curved segment, the mean depth of infiltration was significantly greater in the PUI group than in the control group (P<0.05); the tarnish layer score was lower in each experimental group than in the control group. At the top, the mean depth of infiltration was greater in the PUI and PIPS groups than in the control group (P<0.05), and the smear layer score was lower in the PIPS group than in the other groups (P<0.05). After the time was changed, the depth of infiltration of PUI increased only in the apical segment as the flushing time increased.
CONCLUSIONS
The PUI and PIPS methods facilitate the penetration of irrigation solution into the dentin canal in curved root canals, especially in the apical segment. The PIPS technique is effective in removing the smear layer in curved root canals.
Humans
;
Dental Pulp Cavity
;
Microscopy, Electron, Scanning
;
Root Canal Irrigants
;
Root Canal Preparation/methods*
;
Smear Layer
;
Sodium Hypochlorite
;
Therapeutic Irrigation/methods*
;
Double-Blind Method
4.Influencing factors of Legionella reproduction in secondary water supply operation and management.
Xiao ZHANG ; Sheng Hua GAO ; Jia Yi HAN ; Chen Ming HUANG ; Lan ZHANG
Chinese Journal of Preventive Medicine 2022;56(11):1612-1617
Objective: To analyze the pollution status and influencing factors of Legionella pneumophila in a secondary water supply facility in a city. Methods: From June to August 2020, a survey on the level of Legionella pneumophila in secondary water supply unit was carried out in a city in northern China, and 304 sets of secondary water supply facilities were included in the study. A total of 760 water samples were collected from the inlet and outlet water of the secondary water supply facilities and some water samples in the water tank were collected for the detection of Legionella pneumophila, standard plate-count bacteria and related physical and chemical indicators. Through questionnaire survey, the basic information of secondary water supply facilities and daily management of water quality were collected. Multivariate logistic regression model was used to analyze the influencing factors of Legionella pneumophila contamination. Results: Among 304 sets of secondary water supply facilities, most of them were located in residential buildings [57.24% (174/304)]. High and low water tank water supply, low water tank variable frequency conversion water supply and non-negative pressure water supply accounted for 26.6% (81/304), 36.8% (112/304) and 36.5% (111/304), respectively. About 25.7% of facilities (78/304) were positive for Legionella pneumophila. Among them, the positive rates of Legionella pneumophila in high and low water tank water supply, low water tank variable frequency conversion water supply and non-negative pressure water supply facilities were 38.3% (31/81), 29.5% (33/112) and 12.6% (14/111), respectively. The results of multivariate logistic regression model analysis showed that the disinfectant residue could reduce the risk of Legionella pneumophila contamination in water samples, and the OR (95%CI) value was 0.083 (0.022-0.317). The increase of the standard plate-count bacteria and conductivity might increase the risk of Legionella pneumophila contamination in water samples. The OR (95%CI) values were 3.160 (1.667-5.99) and 1.004 (1.001-1.006), respectively. Compared with the non-negative pressure water supply, the risk of Legionella pneumophila contamination of secondary water supply facilities was increased by water supply from high and low water tanks and variable frequency conversion water supply from low water tanks, with OR (95%CI) values of 4.296 (2.096-8.803) and 2.894 (1.449-5.782), respectively. Conclusion: The positive rate of Legionella pneumophila in secondary water supply in the study city is high. Disinfectant residue, conductivity and method of water supply are associated with the positive rate of Legionella pneumophila.
Humans
;
Legionella
;
Water Microbiology
;
Water Supply
;
Legionella pneumophila
;
Reproduction
;
Disinfectants
5.Research progress in pathogenesis and control of Enterococcus faecalis with persistent infection in root canals.
Tao HU ; Lei LEI ; Xue Dong ZHOU
Chinese Journal of Stomatology 2022;57(1):10-15
Root canal therapy is the common treatment for endodontic infections. Successful root canal therapy depends on favorable root canal preparation, root canal medication and three-dimensional obturation of the root canal system. The key to successful root canal therapy is to prevent re-infection of the highly complex root canal systems by removing infecious biofilms and bacterial toxins in the root canal system. The present paper reviews the pathogenic mechanism of the Enterococcus faecalis in the harsh environment of root canal system, the inflammation and immunity of refractory periapical periodontitis and the progress of infection control methods.
Dental Pulp Cavity
;
Enterococcus faecalis
;
Humans
;
Periapical Periodontitis/therapy*
;
Persistent Infection
;
Root Canal Irrigants
;
Root Canal Preparation
;
Root Canal Therapy
6.Acetic Acid Versus Chlorine Tablet Solution as Disinfectant of Non-Critical Environmental Surfaces
Pediatric Infectious Disease Society of the Philippines Journal 2021;22(2):93-99
Objectives:
This study aims to determine the bactericidal activity of 4% acetic acid versus chlorine tablets against gram negative and gram-positive microorganisms based on percentage reduction of microorganisms in hospital surfaces and suggest that it may be an effective alternative disinfectant.
Methodology:
This was an experimental study where microbiological sampling of hospital surfaces was used to determine bacterial growth. The study was conducted from November to December 2020 at National Children’s Hospital, a 200 bed capacity tertiary government hospital catering to children 0 to less than 19 years old. Non-critical hospital surfaces such as beds, bed rails and bedside tables were swabbed before and after intervention cleaning with chlorine tablets or 4% acetic acid solution.
Result:
Pre-swabbing, hospital surfaces showed the presence of Bacillus sp., Klebsiella pneumoniae and Coagulase Negative Staphylococcus (CONS). Post-application of 4% acetic acid solution resulted to 100% reduction of Bacillus sp., 70.8% reduction of CONS, and 19.5% reduction of Klebsiella pneumoniae while post-application of chlorine tablet solution showed 100% reduction of Klebsiella pneumoniae and CONS and 95.2% reduction of Bacillus species.
Conclusion
The use of 4% acetic acid solution significantly reduced more gram-positive than gram-negative organisms and is a highly effective disinfectant against Bacillus sp. but is not effective against gram-negative organisms as it does not fulfil the criteria of at least 90 percent reduction in bacterial growth. Chlorine tablet solution is a more effective disinfectant against gram-negative organisms than gram-positive organisms. Acetic acid 4% solution is not an effective alternative disinfectant to chlorine tablet solution, the currently used hospital disinfectant, but maybe used as an adjunct for better reduction of hospital environmental pathogens.
Acetic Acid
;
Disinfectants
;
Cross Infection
;
Bacteria
7.Association between use of humidifier disinfectant and allergic rhinitis in Korean children: a cross-sectional study based on the eighth Panel Study on Korean Children (PSKC)
Tae Hwan KOH ; Jong Tae PARK ; Daeil KWON ; Kyeongmin KWAK
Annals of Occupational and Environmental Medicine 2020;32(1):9-
BACKGROUND: Rhinitis was the most frequently diagnosed disorder among users of humidifier disinfectants (HDs). The aim of our study was to investigate on the relationship between allergic rhinitis (AR) and HD uses.METHODS: Our study used the data from the eighth Panel Study on Korean Children; a total of 1,540 participants were enrolled. The χ² test and multiple logistic regression analyses were conducted to debunk the association between AR and HD uses.RESULTS: In our analysis, odds ratios (ORs) of doctor-diagnosed AR increased significantly when simply the response of whether HDs were used in the past was considered. When the brands of HD were considered, ORs of doctor-diagnosed AR were found to be increased significantly for those who have used polyhexamethylene guanidine phosphate/oligo(2-[2-ethoxy]-ethoxyethyl)guanidinium-containing HDs (model 3: 1.41, 95% confidence interval [CI]: 1.02–1.95). However, once duration of usage was additionally considered, ORs of doctor-diagnosed AR increased significantly only for those who have used chloromethylisothiazolinone/methylisothiazolinone-containing HDs for more than or equal to 3 months (model 3: 2.08, 95% CI: 1.17–3.69). Further, past use of HD was associated with significantly increased ORs of AR diagnosed before 2013 (model 3: 1.35, 95% CI: 1.02–1.79).CONCLUSIONS: Results of our study suggest that past uses of HDs may be associated with an increased risk of AR.
Child
;
Cross-Sectional Studies
;
Disinfectants
;
Guanidine
;
Humans
;
Humidifiers
;
Logistic Models
;
Odds Ratio
;
Rhinitis
;
Rhinitis, Allergic
8.Effect of disinfectant with benzethon chloramine and isopropanol as main active ingredients on the accuracy of dental impression.
Di XU ; Dong Hao WEI ; Ya Chi ZHANG ; Ping DI ; Ye LIN
Journal of Peking University(Health Sciences) 2020;52(6):1112-1116
OBJECTIVE:
To assess the effect of disinfectant (Cavicide) with benzethon chloramine and isopropanol as main active ingredients disinfectant on dental impression accuracy.
METHODS:
The effect of Cavicide on three impression materials (alginate, polyether and vinylpolysiloxane) were assessed using a standard model. The standard model was digitized by an extraoral scanner (IScan D103i, Imetric). For each kind of impression materials, thirty impressions were taken following the manufactures' instruction in the same conditions. Subsequently, the impressions were randomly divided into three groups, with ten impressions in each group. After the impression taking was completed, the three groups underwent pure water rinse for 1 min (blank control, BC), 2% glutaraldehyde solution immersion disinfection for 30 min (glutaraldehyde, GD), and Cavicide solution spray disinfection for 5 min (Cavicide, CC), respectively. All the impressions were digitized by the extraoral scanner (IScan D103i, Imetric) after disinfection and exported to a dedicated three-dimensional analysis software (Geomagic Qualify 2014, Geomagic, USA). In the software, the digital models of the impressions were trimmed to teeth and then superimposed with the digitized standard model via best-fit alignment. Root mean square (RMS) was used to evaluate the deviations between the impression and the standard model. The deviation in the anterior and posterior regions was evaluated respectively. One-way ANOVA test and the LSD post-hoc test were used to compare the deviations between the three groups (P < 0.05). The color map of each superimposition was saved for visual analysis.
RESULTS:
For the polyether and vinylpolysiloxane materials, the difference between the three groups was not statistically significant (P=0.933, P=0.827). For the alginate material, the difference in posterior region between group GD and group BC, as well as group GD and group CC were statistically significant (GD vs. BC, P=0.001; GD vs. CC, P=0.002), while the difference between group BC and group CC was not statistically significant (P=0.854). The visual analysis showed an obvious deviation in the buccal-lingual direction in group GD.
CONCLUSION
Disinfectant (Cavicide) with benzethon chloramine and isopropanol as main active ingredients using spray disinfection has no effect on the accuracy of the alginate, polyether and vinylpolysiloxane impressions.
2-Propanol
;
Chloramines
;
Dental Impression Materials
;
Dental Impression Technique
;
Disinfectants
;
Disinfection
;
Models, Dental
9.Problems with diagnostic criteria for humidifier disinfectant lung injury (HDLI): two cases of radiologically improved HDLI
Min Woo NAM ; So Young PARK ; Byung Seong SUH ; Soo Youn HAM ; Kyung Hun SON ; Hyunil KIM ; Hyeong Cheol KIM
Annals of Occupational and Environmental Medicine 2020;32(1):1-
disinfectants and lung disease. At first, we did not think of the relationship to humidifier disinfectant because chest computed tomography (CT) finding of 2 cases were improved. However, they performed lung biopsy and it showed typical humidifier disinfectant lung injury (HDLI) pathologic findings, they could be recognized as HDLI. We report these cases here.CASE PRESENTATION: We selected 2 cases from the fourth-round investigation at Kangbuk Samsung Hospital. Patient of case 1 used humidifier disinfectants since September 2010. The patient was admitted 6 months later to the intensive care unit (ICU) due to severe dyspnea. Pathology following a lung biopsy revealed typical HDLI finding which was determined to be due to humidifier disinfectant exposure. Patient of case 2 used humidifier disinfectant from 2001 to 2008 for about 3 months each winter. The patient's cough and sputum production symptoms began in December of 2007. The patient was admitted to the respiratory medicine department due to worsening dyspnea. Pathology following a lung biopsy revealed typical HDLI finding. This was determined to have been caused by humidifier disinfectant exposure.CONCLUSIONS: Because the typical radiologic findings associated with HDLI can improve over time, it is necessary to consider the revision of current diagnostic criteria that the presence of radiologic findings is important.]]>
Adult
;
Biopsy
;
Cough
;
Disinfectants
;
Dyspnea
;
Humans
;
Humidifiers
;
Intensive Care Units
;
Judgment
;
Korea
;
Lung Diseases
;
Lung Injury
;
Lung
;
Pathology
;
Pulmonary Medicine
;
Sputum
;
Thorax
10.Evaluation of four final irrigation protocols for cleaning root canal walls.
Qiang LI ; Qian ZHANG ; Xiaoying ZOU ; Lin YUE
International Journal of Oral Science 2020;12(1):29-29
The aim of this study was to compare the efficiency of four final irrigation protocols in smear layer removal and bacterial inhibition in root canal systems. Thirty roots inoculated with Enterococcus faecalis were prepared with ProTaper Universal files. The teeth were disinfected by conventional needle irrigation, sonic agitation using the EndoActivator device, passive ultrasonic irrigation, or an M3 Max file. Teeth with no root canal preparation served as blank controls for the establishment of the infection baseline. Teeth with preparation but no final irrigation served as a post-instrumentation baseline. After the final irrigation, the teeth were sectioned in half. One half of each tooth was examined by scanning electron microscopy (SEM) to assess smear layer removal using a five-point scale. The other half was examined by confocal laser scanning microscopy (CLSM) using the LIVE/DEAD BackLight bacterial viability kit to evaluate the depth of bacterial survival in dentinal tubules. SEM analysis revealed no significant difference in smear layer removal throughout the whole canal among the EA, PUI, and M3 Max groups (P > 0.05). CLSM revealed that PUI achieved the greatest bacterial inhibition depth in the coronal ((174.27 ± 31.63) μm), middle ((160.94 ± 37.77) μm), and apical ((119.53 ± 28.49) μm) thirds of the canal (all P < 0.05 vs. other groups). According to this comprehensive SEM and CLSM evaluation, PUI appears to have the best infection control ability in root canal systems.
Dental Pulp Cavity
;
Edetic Acid
;
Humans
;
Microscopy, Electron, Scanning
;
Root Canal Irrigants
;
Root Canal Preparation
;
Smear Layer
;
Sodium Hypochlorite


Result Analysis
Print
Save
E-mail