1.Gradient artificial bone repair scaffold regulates skeletal system tissue repair and regeneration
Yu ZHANG ; Ruian XU ; Lei FANG ; Longfei LI ; Shuyan LIU ; Lingxue DING ; Yuexi WANG ; Ziyan GUO ; Feng TIAN ; Jiajia XUE
Chinese Journal of Tissue Engineering Research 2025;29(4):846-855
BACKGROUND:Gradient artificial bone repair scaffolds can mimic unique anatomical features in musculoskeletal tissues,showing great potential for repairing injured musculoskeletal tissues. OBJECTIVE:To review the latest research advances in gradient artificial bone repair scaffolds for tissue engineering in the musculoskeletal system and describe their advantages and fabrication strategies. METHODS:The first author of the article searched the Web of Science and PubMed databases for articles published from 2000 to 2023 with search terms"gradient,bone regeneration,scaffold".Finally,76 papers were analyzed and summarized after the screening. RESULTS AND CONCLUSION:(1)As an important means of efficient and high-quality repair of skeletal system tissues,gradient artificial bone repair scaffolds are currently designed bionically for the natural gradient characteristics of bone tissue,bone-cartilage,and tendon-bone tissue.These scaffolds can mimic the extracellular matrix of native tissues to a certain extent in terms of structure and composition,thus promoting cell adhesion,migration,proliferation,differentiation,and regenerative recovery of damaged tissues to their native state.(2)Advanced manufacturing technology provides more possibilities for gradient artificial bone repair scaffold preparation:Gradient electrospun fiber scaffolds constructed by spatially differentiated fiber arrangement and loading of biologically active substances have been developed;gradient 3D printed scaffolds fabricated by layered stacking,graded porosity,and bio-3D printing technology;gradient hydrogel scaffolds fabricated by in-situ layered injections,simple layer-by-layer stacking,and freeze-drying method;and in addition,there are also scaffolds made by other modalities or multi-method coupling.These scaffolds have demonstrated good biocompatibility in vitro experiments,were able to accelerate tissue regeneration in small animal tests,and were observed to have significantly improved histological structure.(3)The currently developed gradient artificial bone repair scaffolds have problems such as mismatch of gradient scales,unclear material-tissue interactions,and side effects caused by degradation products,which need to be further optimized by combining the strengths of related disciplines and clinical needs in the future.
2.Optimization of drug management model for investigator-initiated trial with benchmarking analysis
Yufei XI ; Tianxiao WANG ; Xue ZHANG ; Yingzhuo DING ; Li YAN ; Feng JIANG ; Xiangui HE ; Jiannan HUANG ; Qin LI
China Pharmacy 2025;36(3):280-284
OBJECTIVE To optimize the management model of drugs used in investigator-initiated trial (IIT). METHODS With benchmarking analysis, based on the practical work experience of a tertiary specialized hospital in the field of IIT drug management in Shanghai, a thorough review was conducted, involving relevant laws, regulations, and academic literature to establish benchmark criteria and the evaluation standards. Starting from the initiation of IIT projects, a detailed comparative analysis of key processes was carried out, such as the receipt, storage, distribution, use and recycling of drugs for trial. The deficiencies in the current management of IIT drugs were reviewed in detail and a series of optimization suggestions were put forward. RESULTS It was found that the authorized records of drug management were missing, the training before project implementation was insufficient, and the records of receipt and acceptance of IIT drugs were incomplete. In light of these existing problems, improvement measures were put forward, including strengthening the training of drug administrators and stipulating that only drug administrators with pharmacist qualifications be eligible to inspect and accept drugs, etc. The related systems were improved, and 17 key points of quality control for the management of IIT drugs were developed. CONCLUSIONS A preliminary IIT drug management system for medical institutions has been established, which helps to improve the institutional X2023076) framework of medical institutions in this field.
3.Application value of machine learning models based on CT radiomics for assessing split renal function
Junjie ZOU ; Ruidong LI ; Hu SONG ; Feng WANG ; Ning DING ; Kongyuan ZHANG
Chinese Journal of Radiological Health 2025;34(1):108-113
Objective Based on the radiomics features extracted from the unenhanced CT images of the lower abdomen, a variety of machine learning models were constructed to explore their application value in the assessment of split renal function. Methods A retrospective analysis was conducted on the unenhanced CT images from 240 single kidneys in patients with clinically suspected renal dysfunction. Based on the results of single-photon emission computed tomography renal dynamic imaging, the cases were classified into the normal glomerular filtration rate group (n=118) and the decreased glomerular filtration rate group (n=122). The region of interest was outlined on the unenhanced CT images and the radiomics features were extracted. The features were selected by correlation analysis and least absolute shrinkage and selection operator, and the machine learning models were constructed based on the algorithms of decision tree, support vector machine, random forest, logistic regression, and extreme gradient boosting. Area under the receiver operating characteristic curve, accuracy, sensitivity, and specificity were calculated to compare the performance of different models. Results Sixteen radiomics features were selected for constructing the machine learning models. The support vector machine model showed relatively high performance for the assessment of split renal function on the test set, with an area under the receiver operating characteristic curve value of 0.883 (95% confidence interval: 0.804-0.961), an accuracy of 0.778, a sensitivity of 0.811, and a specificity of 0.743. Conclusion The machine learning models constructed based on unenhanced CT radiomics can be used to preliminarily assess split renal function, which provides an innovative, convenient, and safe method for clinical diagnosis and has positive significance for treatment.
4.Characteristic volatile organic compounds in exhaled breath of coal workers' pneumoconiosis patients by thermal desorption gas chromatography-mass spectrometry
Yazhen HE ; Chunguang DING ; Junyun WANG ; Yuzhen FENG ; Fangda PENG ; Gaisheng LIU ; Fan YANG ; Chunmin ZHANG ; Rui GAO ; Qingyu MENG ; Zhijun WU ; Jingguang FAN
Journal of Environmental and Occupational Medicine 2025;42(5):571-577
Background Coal workers' pneumoconiosis is a serious occupational disease in China. Exhaled volatile organic compounds (VOCs) can serve as the "breath fingerprint" of internal pathological processes, which provides a theoretical basis for exhaled VOCs to be used as potential non-invasive biomarkers for early diagnosis of coal workers' pneumoconiosis. Objective To screen out the characteristic VOCs and important characteristic VOCs of exhaled air in patients with coal workers' pneumoconiosis, and to explore the potential of these VOCs as biomarkers for early non-invasive diagnosis of the disease. Methods In this study, 27 VOCs in the exhaled breath of 22 patients with stage I coal workers' pneumoconiosis, 77 workers exposed to dust, and 92 healthy controls were quantitatively detected by thermal desorption gas chromatography-mass spectrometry (TD-GC-MS). Substances with P<0.05 in univariate analysis and variable importance projection (VIP) >1 in supervised orthogonal partial least squares discriminant analysis (OPLS-DA) model were selected as the characteristic VOCs for early diagnosis of coal workers' pneumoconiosis. Age was included in the LASSO regression model as a covariate to screen out important characteristic VOCs, and the diagnostic performance was evaluated by receiver operating characteristic (ROC) curve. Spearman correlation was further used to explore the correlation between important characteristic VOCs and clinical lung function indicators. Results Through univariate analysis and OPLS-DA modeling, 8 VOCs were selected, including 2-methylpentane, 3-methylpentane, n-hexane, methylcyclopentane, n-heptane, methylcyclohexane, 4-methyl-2-pentanone, and 2-hexanone, in exhaled breath of patients with coal workers' pneumoconiosis. The concentrations of 4 VOCs, including 3-methylpentane, n-hexane, 4-methyl-2-pentanone, and 2-hexanone, showed a decreasing trend with the increase of dust exposure years. By LASSO regression, the important characteristic VOCs of the coal workers' pneumoconiosis group and the dust exposure group were n-hexane, methylcyclohexane and 4-methyl-2-pentanone, and the important characteristic VOCs of the coal workers' pneumoconiosis group and the healthy group were 2-methyl-pentane and 4-methyl-2-pentanone. The ROC analysis showed that the area under the curve (AUC) of n-hexane, methylcyclohexane, and 4-methyl-2-pentanone were 0.969, 0.909, and 0.956, respectively, and the AUC of combined diagnosis was 0.988 and its Youden index was 0.961, suggesting that these results can serve as a valuable reference for further research on early diagnosis. The Correlation analysis found that there was a positive correlation between n-hexane and lung function indicators in the important characteristic VOCs, indicating that it could indirectly reflect the obstruction of lung function ventilation, further proving that important characteristic VOCs have the potential to monitor lung function decline. Conclusion Three important characteristic VOCs selected in this study have the potential to be used as non-invasive biomarkers for early diagnosis and disease monitoring of coal workers' pneumoconiosis, and are worthy of further study and verification.
5.Expert consensus on the positioning of the "Three-in-One" Registration and Evaluation Evidence System and the value of orientation of the "personal experience"
Qi WANG ; Yongyan WANG ; Wei XIAO ; Jinzhou TIAN ; Shilin CHEN ; Liguo ZHU ; Guangrong SUN ; Daning ZHANG ; Daihan ZHOU ; Guoqiang MEI ; Baofan SHEN ; Qingguo WANG ; Xixing WANG ; Zheng NAN ; Mingxiang HAN ; Yue GAO ; Xiaohe XIAO ; Xiaobo SUN ; Kaiwen HU ; Liqun JIA ; Li FENG ; Chengyu WU ; Xia DING
Journal of Beijing University of Traditional Chinese Medicine 2025;48(4):445-450
Traditional Chinese Medicine (TCM), as a treasure of the Chinese nation, plays a significant role in maintaining public health. In 2019, the Central Committee of the Communist Party of China and the State Council proposed for the first time the establishment of a TCM registration and evaluation evidence system that integrates TCM theory, "personal experience" and clinical trials (referred to as the "Three-in-One" System) to promote the inheritance and innovation of TCM. Subsequently, the National Medical Products Administration issued several guiding principles to advance the improvement and implementation of this system. Owing to the complexity of its implementation, there are still differing understandings within the TCM industry regarding the positioning of the "Three-in-One" Registration and Evaluation Evidence System, as well as the connotation and value orientation of the "personal experience." To address this, Academician WANG Qi, President of the TCM Association, China International Exchange and Promotion Association for Medical and Healthcare and TCM master, led a group of academicians, TCM masters, TCM pharmacology experts and clinical TCM experts to convene a "Seminar on Promoting the Implementation of the ′Three-in-One′ Registration and Evaluation Evidence System for Chinese Medicinals." Through extensive discussions, an expert consensus was formed, clarifying the different roles of the TCM theory, "personal experience" and clinical trials within the system. It was further emphasized that the "personal experience" is the core of this system, and its data should be derived from clinical practice scenarios. In the future, the improvement of this system will require collaborative efforts across multiple fields to promote the high-quality development of the Chinese medicinal industry.
6.AI-HIP system for prosthesis size,global femoral offset and osteotomy in total hip arthroplasty
Guo-Yuan SUN ; Yan-Kun JIANG ; Tong LI ; Xue-Feng CONG ; Cheng HUANG ; Ran DING ; Wei-Guo WANG ; Qi-Dong ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(9):848-854
Objective To explore planning effect of AI-HIP assisted surgical planning system in primary unilateral total hip arthroplasty(THA)and its influence on clinical outcomes.Methods A retrospective analysis was conducted on clinical data of 36 patients who underwent their first unilateral THA from March 2022 to November 2022 and continuously used AI-HIP system(AI-HIP group),including 16 males and 20 females,aged from 43 to 81 years old with an average of(62.2±10.9)years old.According to the matching principle,36 patients who were planned by the traditional template method at the same period were selected as the control group,including 16 males and 20 females,aged from 40 to 80 years old with an average of(60.9±12.1)years old.The accuracy between two groups of prostheses were compared,as well as the combined eccentricity difference between preoperative planning and postoperative practice,lower limb length difference,osteotomy height from the upper edge of the lesser trochanter and top shoulder distance to evaluate planning effect.Harris score and visual analogue scale(VAS)were used to evaluate clinical efficacy.Results Both groups were followed up for 12 to 18 months with an average of(14.5±2.1)months.The complete accuracy and approximate accuracy of acetabular cup and femoral stalk prosthesis in AI-HIP group were 72.2%,100%,58.3%,88.9%,respectively,which were better than 44.4%,83.3%,33.3%,66.7%in control group(P<0.05).There was no statistical significance in planning of femoral head prosthesis size(P>0.05).The actual combined eccentricity difference and combined eccentricity difference(practical-planning)in Al-HIP group were 1.0(0.2,2.4)mm and 1.1(-2.1,3.2)mm,respectively;which were better than 3.0(1.4,4.9)mm and 3.5(-1.6,6.5)mm in control group(P<0.05).There was no significant difference between two groups in actual osteotomy height of the upper margin of the lesser trochanter(P>0.05).In AI-HIP group,the actual difference of lower extremity length after surgery,the difference of lower extremity length(practical-planning),osteotomy height from the upper margin of lesser trochanter(practical-planning),actual topshoulder distance after surgery,and topshoulder distance(practical-planning)were 1.5(0.2,2.8),1.1(-0.3,2.2),2.1(-2.3,4.1),(15.3±4.1),2.2(-4.8,0.3)mm,respectively;which were better than control group of 2.6(1.3,4.1),2.5(0.3,3.8),5.8(-2.4,7.7),(13.0±4.3),-5.7(-9.4,-2.2)mm(P<0.05).At final follow-up,there were no significant differences in Harris scores of pain,function,deformity,total scores and VAS between two groups(P>0.05).The range of motion score was 4.8±0.6 in AI-HIP group,which was higher than that in control group(4.4±0.8)(P<0.05).Conclusion Compared with traditional template planning,AI-HIP assisted surgical planning system has good accuracy in predicting the prosthetic size of the acetabular cup and femoral stalk,restor-ing joint eccentricity,planning lower limb length,osteotomy height and top shoulder distance on the first unilateral THA,and the clinical follow-up effect is satisfactory.
7.Surveillance of antifungal resistance in clinical isolates of Candida spp.in East China Invasive Fungal Infection Group from 2018 to 2022
Dongjiang WANG ; Wenjuan WU ; Jian GUO ; Min ZHANG ; Huiping LIN ; Feifei WAN ; Xiaobo MA ; Yueting LI ; Jia LI ; Huiqiong JIA ; Lingbing ZENG ; Xiuhai LU ; Yan JIN ; Jinfeng CAI ; Wei LI ; Zhimin BAI ; Yongqin WU ; Hui DING ; Zhongxian LIAO ; Gen LI ; Hui ZHANG ; Hongwei MENG ; Changzi DENG ; Feng CHEN ; Na JIANG ; Jie QIN ; Guoping DONG ; Jinghua ZHANG ; Wei XI ; Haomin ZHANG ; Rong TANG ; Li LI ; Suzhen WANG ; Fen PAN ; Jing GAO ; Lu JIANG ; Hua FANG ; Zhilan LI ; Yiqun YUAN ; Guoqing WANG ; Yuanxia WANG ; Liping WANG
Chinese Journal of Infection and Chemotherapy 2024;24(4):402-409
Objective To monitor the antifungal resistance of clinical isolates of Candida spp.in the East China region.Methods MALDI-TOF MS or molecular methods were used to re-identify the strains collected from January 2018 to December 2022.Antifungal susceptibility testing was performed using the broth microdilution method.The susceptibility test results were interpreted according to the breakpoints of 2022 Clinical and Laboratory Standards Institute(CLSI)documents M27 M44s-Ed3 and M57s-Ed4.Results A total of 3 026 strains of Candida were collected,65.33%of which were isolated from sterile body sites,mainly from blood(38.86%)and pleural effusion/ascites(10.21%).The predominant species of Candida were Candida albicans(44.51%),followed by Candida parapsilosis complex(19.46%),Candida tropicalis(13.98%),Candida glabrata(10.34%),and other Candida species(0.79%).Candida albicans showed overall high susceptibility rates to the 10 antifungal drugs tested(the lowest rate being 93.62%).Only 2.97%of the strains showed dose-dependent susceptibility(SDD)to fluconazole.Candida parapsilosis complex had a SDD rate of 2.61%and a resistance rate of 9.42%to fluconazole,and susceptibility rates above 90%to other drugs.Candida glabrata had a SDD rate of 92.01%and a resistance rate of 7.99%to fluconazole,resistance rates of 32.27%and 48.24%to posaconazole and voriconazole non-wild-type strains(NWT),respectively,and susceptibility rates above 90%to other drugs.Candida tropicalis had resistance rates of 29.55%and 26.24%to fluconazole and voriconazole,respectively,resistance rates of 76.60%and 21.99%to posaconazole and echinocandins non-wild-type strains(NWT),and a resistance rate of 2.36%to echinocandins.Conclusions The prevalence and species distribution of Candida spp.in the East China region are consistent with previous domestic and international reports.Candida glabrata exhibits certain degree of resistance to fluconazole,while Candida tropicalis demonstrates higher resistance to triazole drugs.Additionally,echinocandins resistance has emerged in Candida albicans,Candida glabrata,Candida tropicalis,and Candida parapsilosis.
8.Cloning and expression of the K26 gene of Leishmania and evaluation of detection of specific antibodies against visceral leishmaniasis in China
Dan DING ; Ying WANG ; Chun-Hua GAO ; Xiao-Jin MO ; Feng SHI ; Jing ZHANG ; Xiao-Kai JIA ; Fu-Rong WEI
Chinese Journal of Zoonoses 2024;40(8):763-767
To clone and express the K26 gene of Leishmania isolated from three types of visceral leishmaniasis epidemic ar-eas in China and evaluate its effect on detecting specific antibodies against visceral leishmaniasis.The K26 fragments from Leishmania isolated KS-6,SC6 and JIASHI-1 was synthesized and cloned into pET32a vector.The recombinant plasmid pET32a-K26 was transformed into Escherichia coli BL21 strains and induced by isopropyl-β-D-thiogalactopyranoside(IPTG).The expressed recombinant protein was purified by the His-tagged affinity column(Ni-NTA).Serum samples of 110 visceral leishmaniasis patients were used for evaluating the sensitivity by ELISA.Serum samples from patients with malaria,schisto-somiasis japonica,cystechinococcosis,toxoplasmosis,paragon-imiasis,clonorchiosis and 40 healthy people were used for eval-uating the specificity.Detection results of ELISA were compared with that of rK39 strip of American InBios company.Comparation among three K26 antigens were given by x2 test.The sensitivity of the recombinant K26 protein of KS-6,SC6 and JIASHI-5 strains of Leishmania and rK39 strip test to detect the sera of patients with visceral leishmaniasis was 90.00%(99/110),92.73%(102/110),90.91%(100/110)and 93.64%(103/110),respectively.There was no cross reactivity with malaria(10),schistosomiasis japonica(10),cystechinococcosis(10),toxoplasmosis(5),paragonimiasis(5)and clonorchiosis(5),and 40 sera from healthy people were also negative.The specificity was 100.00%.There was no statistical difference in the sensitivity of the recombinant K26 protein of KS-6,SC6 and JIASHI-1 strains of Leishmania and rK39 strip test,x2 values are 0.97,0.07 and 0.57 respectively and the P values are 0.33,0.79 and 0.45,respectively.There was no statis-tical difference in the sensitivity of three K26 antigens(x2=0.53,P=0.97).Conclusion The recombinant K26 antigen has po-tential application value in the diagnosis of visceral leishmaniasis.
9.Research progress in sialic acid-binding immunoglobulin-like lectins in bacterial infectious diseases
Yue-Yue HE ; Yue-Jie ZHU ; Yi-Chen FAN ; Zheng-Wei YIN ; Juan SHI ; Feng-Bo ZHANG ; Jian-Bing DING
Chinese Journal of Zoonoses 2024;40(8):790-795
Sialic acid-binding immunoglobulin-like lectins(Siglecs)are expressed on most white blood cells and play a key role in signal transduction of immune cells.Recent studies have shown that many bacterial pathogens regulate the host immune response through the interaction between sialic acid(Sia)and Siglecs,thereby influencing the occurrence and development of diseases.Understanding bacterial pathogenic mechanisms is essential to identify potential effective therapeutic targets and help manage bacterial infectious diseases.Herein,the structure,biological function,and research progress in Siglecs in bacterial in-fectious diseases are briefly reviewed.
10.Analysis of Clinical Characteristics and Lead Extraction in Patients With Venous Occlusion Related to Infection of Cardiovascular Implantable Electronic Devices
Wenqiong ZHANG ; Feng ZE ; Ding LI ; Cuncao WU ; Xu ZHOU ; Yi WEI ; Xuebin LI
Chinese Circulation Journal 2024;39(9):859-864
Objectives:To assess the clinical characteristics and lead extraction in patients with venous occlusion related to infection of cardiovascular implantable electronic devices. Methods:Clinical data of 405 patients(147 men,mean age[62.4±13.2]years)who underwent lead extraction from January 2020 to January 2024 in Peking University People's Hospital were reviewed.Contrast venography of the access vein was retrospectively analyzed.The patients were divided into venous occlusion group(n=119)and non-venous occlusion group(n=286)according to the presence or absence of venous occlusion.The clinical characteristics and lead extraction of patients in two groups were analyzed. Results:Occlusion of the access vein occurred in 119 patients(29.4%).The subclavian vein was occluded in 48 cases(40.3%),brachiocephalic vein was occluded in 37 cases(31.1%),axillary vein was occluded in 30 cases(25.2%),superior vena cava was occluded in 4 cases(3.4%).There were no significant differences between venous occlusion group and non-venous occlusion group in terms of age,sex,device type,number of leads,or anticoagulation therapy(all P>0.05).Time from implant of the initial leads was significantly longer in the venous occlusion group than in the non-venous occlusion group([10.4±3.8]years vs.[5.9±4.1]years,P=0.042).Clinical extraction success rate and complications were similar between the venous occlusion group and the non-venous occlusion group(both P>0.05).Procedural duration and fluoroscopy exposure time were significantly lower in non-venous occlusion group than in the venous occlusion group(both P<0.05).Patients in the venous occlusion group required more advanced tools(such as laser sheaths,evolution sheaths,and needle's eye snares)for lead extraction compared to patients in the non-venous occlusion group(84.0%vs.67.1%,P=0.001). Conclusions:The incidence of venous occlusion related to infection of cardiovascular implantable electronic devices is 29.4%.Time from implant of the initial leads is significantly longer and lead extraction is more difficult in patients with venous occlusion,and requires more advanced tools and more time to achieve the successful lead extraction.