1.Transcatheter edge-to-edge repair using MitraClipTM G4 for severe mitral regurgitation in an advanced elderly patient with Barlow disease.
Fei LUO ; Jiafeng WANG ; Zhifu GUO ; Yongwen QIN ; Yuan BAI
Journal of Zhejiang University. Medical sciences 2025;54(2):199-203
A 91-year-old male patient was admitted with a history of mitral valve prolapse diagnosed by physical examination ten years prior and recent onset of exertional chest discomfort persisting for over one month. Transthoracic echocardiography showed that the anterior leaflet of mitral valve was thickened and prolapsed with severe regurgitation, and transesophageal echocardiography further confirmed that the anterior and posterior leaflets of mitral valve were prolapsed with massive regurgitation (A1, A2, A3, P1 and P2 were all prolapsed). Thus, the diagnosis of Barlow syndrome was considered. Transcatheter edge-to-edge mitral repair was performed with two MitraClipTM G4 XTWs. After a 10 months follow-up, the patient's cardiac function was significantly improved, and the degree of mitral regurgitation was mild.
Humans
;
Male
;
Aged, 80 and over
;
Mitral Valve Insufficiency/surgery*
;
Mitral Valve Prolapse/diagnostic imaging*
;
Cardiac Catheterization/methods*
;
Mitral Valve/surgery*
;
Heart Valve Prosthesis Implantation/methods*
2.Transesophageal echocardiography assessment of mitral valve for patients with atrial septal defects undergoing surgical repair.
Yuxi LI ; Xin MENG ; Wei BAI ; Liang CAO ; Guomeng JIANG ; Jianlong YANG ; Xuezeng XU ; Liwen LIU
Journal of Zhejiang University. Medical sciences 2025;54(2):191-198
OBJECTIVES:
To investigate the application of transesophageal echocar-diography assessment for mitral valve in patients with atrial septal defects undergoing repair surgery.
METHODS:
The study group comprised of thirty-two adult patients with atrial septal defect who underwent thoracoscopic repair surgery at the First Affiliated Hospital of the Air Force Medical University from March to September 2022. Two-dimensional and real-time three-dimensional transesophageal ultrasonography of the mitral valve were performed after anesthesia. The parameters of the mitral valve structure at the late diastolic and late systolic stages were recorded, including anteroposterior and left-right annular diameters, anterior and posterior valves lengths, the vertical distance from the coaptation point of leaflet zone 2 during systole to the annular plane (mitral valve coaptation depth) and mitral valve coaptation length. Data from 32 patients with normal intracardiac structure and no mitral valve regurgitation (control group) were also collected and compared with those of the study group. Concurrent mitral valvoplasty was performed during the atrial septal defect repair surgery for 7 patients with significant mitral valve structural abnormalities and 2 patients with significantly increased mitral regurgitation after cardiac resuscitation. The study group was followed up with transthoracic echocardiography for 2 years postoperatively.
RESULTS:
In the study group, 26 (81.3%) patients had varying degrees of mitral valve morphological abnormalities. Among them, 10 (31.3%) patients had short mitral valve coaptation length or depth, 12 (37.5%) patients had closure point malposition, and 4 (12.5%) patients had different bulge of anterior and posterior leaflets. Compared with the control group, the study group had significantly smaller systolic and diastolic mitral left-right annular diameter, mitral posterior valves lengths, mitral coaptation length or depth (all P<0.05), a higher pulmonary systemic flow ratio (P<0.01), and a lower maximum blood flow velocity across the mitral valve (P<0.05). After 2 years of follow-up, among the 9 patients who underwent concurrent mitral valvoplasty, the mitral valve maintained no or little regurgitation, and the average mitral valve pressure difference was less than 5 mmHg (1 mmHg=0.133 kPa). Among the 23 patients without concurrent mitral valvoplasty, 2 patients had moderate regurgitation 1 year after surgery, with a pulmonary/systemic flow ratio larger than 2.8.
CONCLUSIONS
Patients with large atrial septal defects often have abnormal mitral valve structure. Therefore transesophageal echocardiography is recommended for mitral valve assessment during the surgery. If significant mitral valve structural abnormalities are detected, concurrent mitral valvoplasty is recommended.
Humans
;
Heart Septal Defects, Atrial/diagnostic imaging*
;
Echocardiography, Transesophageal/methods*
;
Mitral Valve/surgery*
;
Adult
;
Female
;
Male
;
Middle Aged
;
Mitral Valve Insufficiency/diagnostic imaging*
3.Advancements in Research on Preoperative Localization of Pulmonary Nodules.
Jialong CHEN ; Lei ZHOU ; Lingling QIN ; Chunlai LIU
Chinese Journal of Lung Cancer 2025;28(5):385-390
In recent years, the widespread application of chest computed tomography (CT) screening has led to a significant increase in the detection rate of pulmonary nodules. As a critical diagnostic tool for early-stage lung cancer, video-assisted thoracic surgery (VATS) has emerged as the preferred therapeutic approach for pulmonary nodules. Clinical evidence demonstrates that precise preoperative localization significantly enhances surgical success rates (reducing conversion to thoracotomy), minimizes complications, and shortens operation time. This comprehensive review systematically evaluates six cutting-edge localization techniques: percutaneous puncture-assisted localization, electromagnetic navigation bronchoscopy (ENB) localization, 3D-printed auxiliary localization, basin-analysis-based localization, robotic navigation system localization, and mixed reality (MR)-guided localization. By critically analyzing their operational principles, efficacy, safety profiles, and clinical applicability, this paper aims to provide evidence-based recommendations for optimizing clinical decision-making in pulmonary nodule management.
.
Humans
;
Lung Neoplasms/diagnosis*
;
Solitary Pulmonary Nodule/diagnostic imaging*
;
Thoracic Surgery, Video-Assisted/methods*
;
Multiple Pulmonary Nodules/diagnostic imaging*
;
Tomography, X-Ray Computed
4.Significance of precise classification of sacral meningeal cysts by multiple dimensions radiographic reconstruction MRI in guiding operative strategy and rehabilitation.
Jianjun SUN ; Qianquan MA ; Xiaoliang YIN ; Chenlong YANG ; Jia ZHANG ; Suhua CHEN ; Chao WU ; Jingcheng XIE ; Yunfeng HAN ; Guozhong LIN ; Yu SI ; Jun YANG ; Haibo WU ; Qiang ZHAO
Journal of Peking University(Health Sciences) 2025;57(2):303-308
OBJECTIVE:
To precise classify sacral meningeal cysts, effective guide minimally invasive neurosurgery and postoperative personalized rehabilitation by multiple dimensions radiographic reconstruction MRI.
METHODS:
From March to December 2021, based on the original 3D-fast imaging employing steadystate acquisition (FIESTA) scanning sequence, 92 patients with sacral meningeal cysts were pre-operatively evaluated by multiple dimensional reconstruction MRI. The shape of nerve root and the leakage of cyst were reconstructed according to the direction of nerve root or leakage track showed on original MRI scans. Sacral canal cysts were accurately classified as including nerve root and without nerve root, so as to accurately design the incision of skin and formulate corresponding open range of the posterior wall of the sacral canal. Under the microscope intraoperation, the shape of the nerve roots inside cysts or leakage track of the cysts without nerve roots were verified and explored. After the reinforcement and shaping operation, several reexaminations of multiple dimensional reconstruction MRI were performed to understand the deformation of the nerve root and hydrops in the operation cavity, so as to formulate a persona-lized rehabilitation plan for the patients.
RESULTS:
Among the 92 patients with sacral mengingeal cyst, 58 (63.0%) cysts with nerve root cyst, 29 (31.5%) cysts without nerve root cyst, and 5 (5.4%) cysts with mixed sacral canal cyst. In 58 patients with nerve root cysts, the accuracy of preoperative clinical classification on MRI image reached 96.6% (56/58) through confirmation by operating microscope. Only 2 cases of large single cyst with nerve root on the head of cyst were mistaken for without nerve root type. In 29 patients with sacral cyst without nerve root, the accuracy of preoperative image reached 100% through confirmation by operating microscope. The accuracy of judging the internal nerve root and leakage of 12 cases with recurrent sacral cyst was also 100%. Two cases of delayed postoperative hydrops were found one month after operation. After rehabilitation treatment by moxibustion and bathing, the hydrops disappeared 4-6 months after operation.
CONCLUSION
Multiple dimensional reconstruction MRI can precisely make clinical classification of sacral meningeal cysts before operation, guide minimally invasive neurosurgery effectively, and improve the rehabilitation effect.
Humans
;
Magnetic Resonance Imaging/methods*
;
Male
;
Female
;
Sacrum/surgery*
;
Adult
;
Middle Aged
;
Imaging, Three-Dimensional/methods*
;
Cysts/rehabilitation*
;
Aged
;
Adolescent
;
Young Adult
;
Spinal Nerve Roots/diagnostic imaging*
;
Minimally Invasive Surgical Procedures
;
Neurosurgical Procedures/methods*
5.Personalized mandibular reconstruction assisted by three-dimensional retrieval model based on fully connected neural network and a database of mandibles.
Shiyu QIU ; Yang LIAN ; Yifan KANG ; Lei ZHANG ; Yiwang CAI ; Xiaofeng SHAN ; Zhigang CAI
Journal of Peking University(Health Sciences) 2025;57(2):360-368
OBJECTIVE:
To propose a new protocol for personalized mandibular reconstruction assisted by three-dimensional (3D) retrieval model based on fully connected neural network (FCNN) and a database of mandibles, and to verify clinical feasibility of the protocol.
METHODS:
A database of mandibles of 300 normal northern Chinese Han people was established. On the basis of cephalometry, the mandible landmarks with good stability were further screened. Mandibular landmarks were selected and geometric features of the mandible were extracted. A 3D retrieval algorithm was developed, which could retrieve the mandible most similar to a given mandible from the database. A FCNN was built to train the algorithm to improve accuracy of the 3D retrieval model. Using Geomagic Control 2014 software, matching accuracy of the 3D retrieval model was based on aforementioned mandible database and algorithm. From December 2019 to March 2021, a total of 5 patients underwent personalized mandibular reconstruction assisted by a 3D retrieval model based on mandible database and FCNN in the Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology. The most similar mandible was retrieved from mandible database through 3D retrieval algorithm. It was used to restore the premorbid morphology of defect area and guide mandibular reconstruction. For the 5 patients, mandible was reconstructed with iliac flap. Virtual surgical plan was transformed using individual surgical guides.
RESULTS:
Through screening, mandibular landmarks with high reproducibility and stability were identified and composed of mandibular landmarker protocols. After training, the average deviation between most similar mandible retrieved from the 300-case mandible database through 3D retrieval model based on FCNN and given mandible was (1.77±0.44) mm. And the root-mean-square deviation between the most similar mandible retrieved from the database and given mandible was (2.58±0.86) mm. The mandibular reconstruction surgery was successful in all the 5 patients. Their facial symmetry and occlusion were restored. All the patients were satisfied with postoperative appearance. The mean deviation between postoperative mandible and preoperative design was (0.98±0.17) mm. The area with a deviation ≤1 mm accounted for 61.34%±14. 13%, ≤2 mm accounted for 83.82%±7.35%, and ≤3 mm accounted for 93.94%± 2.87%.
CONCLUSION
The personalized mandibular reconstruction assisted by 3D retrieval model based on the 300-case mandible database and FCNN is feasible clinically.
Humans
;
Neural Networks, Computer
;
Mandibular Reconstruction/methods*
;
Mandible/diagnostic imaging*
;
Imaging, Three-Dimensional/methods*
;
Adult
;
Databases, Factual
;
Female
;
Male
;
Algorithms
;
Middle Aged
;
Cephalometry
6.In vitro study of using single cone obturation technique in artificial canals with an isthmus.
Journal of Peking University(Health Sciences) 2025;57(2):369-375
OBJECTIVE:
To evaluate the filling quality of single cone obturation in root canal model with irregular structure (Hus&Kim Ⅴ, Yin Ⅱ-type isthmus) which established by 3D printing technology using slices and radiographic methods, in order to provide reference for clinical practice.
METHODS:
(1) Extracted fresh premolars with Hus&Kim Ⅴ and Yin-type Ⅱ isthmus were collected and scanned by cone-beam computed tomography (CBCT), then standard root canal models were designed and printed. Rhodamine B staining and bias fitting were used to verify the availability of the models. (2) 30 root canal models were randomly divided into 3 groups according to different filling methods (n=10).
CONTROL GROUP:
vertical compaction obturation; Experimental group 1: single cone obturation with 0.06-taper cone (30#); Experimental group 2: single cone obturation with 0.04-taper cone (35#), GuttaFlow 2 as canal sealers. Slices were taken at 2, 4, 6, and 8 mm from the root apex in the direction perpendicular to the long axis of the root and observed under a stereomicroscope to calculate the percentage of filling area (PAV), percentage of gutta-percha-filled area (PGFA), percentage of sealer filled area (PSFA). (3) On the basis of the above results, two groups (n=4) were selected to further analyze the filling quality by micro-computed tomography (Micro-CT), the filling volume of main root canal and the isthmus were obtained, and the percentage of filling volume (PFV) was calculated. Two-way ANOVA was used to evaluate the differences between the groups, and Tukey' s multiple comparison was used to compare the data between the groups and within the groups.
RESULTS:
(1) Rhodamine B staining solution could overflow the apical foramen, and the main root canal system and the isthmus area were stained, showed no remnants of support material. The 3D standard deviation of the printed model data was 0.03 mm, and the average fitting distance was 0.02 mm. (2) The PFA of the two experimental groups were both significantly lower than that of the control group (F=45.04, P < 0.01). There was no statistical difference of the PFA at apical 2 and 4 mm between the two experimental groups (P>0.01), but at the middle and coronal portions of the root canal (6, 8 mm), the PFA of the experimental group 1 was higher than that of the experimental group 2 (P < 0.01). PFA in the apical 2, 4 mm of the two experimental groups were both lower than that in the middle and coronal portions 6, 8 mm of the canal (P < 0.01). There was no difference in the PGFA and PSFA between the two experimental groups at the apical 2, 4 mm (F=2.383, P>0.01). (3) The results of Micro-CT showed that the PFV of the experimental group 1 was statistically different with the control group (F=47.33, P < 0.01). The PFV of the experimental group 1 was 54.33%±4.35% in the isthmus and 78.31%±4.21% in the main root canal, which were both lower than the PFV of the control group of 76.48%±4.89% (isthmus) and 86.90%±3.29% (main root canal, P < 0.01). The PFV of the main root canal in the experimental group 1 was higher than that in the isthmus (P < 0.01), while there was no difference between the isthmus and the main root canal in the control group (P>0.01).
CONCLUSION
In the irregular root canal structure with isthmus, using large-taper gutta-percha can improve the filling quality of the middle and upper part of the canal, but the percentage of filling volume in the isthmus is lower than that of the main canal, and more technical improvements are needed.
Humans
;
Root Canal Obturation/methods*
;
Cone-Beam Computed Tomography
;
Root Canal Filling Materials
;
Dental Pulp Cavity/diagnostic imaging*
;
Printing, Three-Dimensional
;
In Vitro Techniques
;
Gutta-Percha
;
Bicuspid
7.Renal autotransplantation for the treatment of complex renal aneurysm in a child: A case report.
Lei YU ; Wenbo YANG ; Yufan YANG ; Qiang WANG
Journal of Peking University(Health Sciences) 2025;57(2):396-399
Renal autotransplantation (RA) offers significant technical advantages for the management of certain complex renal vascular diseases, such as complex renal aneurysms and renal artery malformations. This report describes a case of a 5-year-old child with a complex left renal artery aneurysm combined with multiple aneurysms. The child was admitted to Peking University People's Hospital in December 2023 due to a one-year history of intermittent abdominal pain, with an abdominal mass detected in the past month. Computed tomography angiography(CTA) revealed multiple vascular anomalies, including: (1) a left renal artery aneurysm, (2) an abdominal aortic aneurysm, and (3) a right iliac artery aneurysm. After a comprehensive evaluation of these findings, the surgical team developed a treatment plan that involved the excision of the left renal artery aneurysm, autotransplantation of the left kidney, and resection of the abdominal aortic aneurysm with an artificial vascular catheterization. During surgery, it was discovered that the left renal artery anatomy was highly complex. The artery had two primary branches, along with an additional polar artery located at the lower pole. The aneurysm was identified at the distal end of the renal artery trunk, with a pronounced bulging at the intersection between the main renal artery trunk and its secondary branches. Due to these structural complexities, the team decided to use an ex vivo surgical approach to repair the aneurysm. Ex vivo repair involves temporarily removing the kidney from the body to repair the renal artery aneurysm with enhanced precision, enabling the surgical team to meticulously reconstruct the complex vascular architecture without the constraints of in vivo manipulation. The ex vivo repair of the renal artery aneurysm was successful, allowing for accurate vascular reconstruction and avoiding potential intraoperative complications. Following the reconstruction, the kidney was autotransplanted back into the child's body, and blood flow was effectively restored to the organ. The therapeutic outcome was excellent, with the child experiencing no postoperative complications. The patient recovered well and was discharged from the hospital in stable condition. This case underscores the value of renal autotransplantation combined with ex vivo repair for pediatric patients with complicated renal artery aneurysms. Through this report, we aim to provide insights and considerations for the surgical treatment of similar cases in children with complex renal vascular anatomy.
Child, Preschool
;
Humans
;
Aneurysm/surgery*
;
Aortic Aneurysm, Abdominal/diagnostic imaging*
;
Computed Tomography Angiography
;
Iliac Aneurysm/surgery*
;
Kidney Transplantation/methods*
;
Renal Artery/abnormalities*
;
Transplantation, Autologous
8.Imaging study of osteogenesis in maxillary sinus segment of zygomatic implants.
Ziyang YU ; Houzuo GUO ; Xi JIANG ; Weihua HAN ; Ye LIN
Journal of Peking University(Health Sciences) 2025;57(5):967-974
OBJECTIVE:
To assess the osteogenesis height in maxillary sinus segment one year after zygomatic implantation by imaging methods, and evaluate the influence of patient factors, maxillary sinus anatomical factors and surgical factors on postoperative osteogenesis height.
METHODS:
This study is a retrospective study, including patients who underwent zygomatic implantation and whose zygomatic implants passed through the maxillary sinus at the Department of Implantology, Peking University School and Hospital of Stomatology from July 2017 to January 2022. Preoperative and postoperative cone beam CT (CBCT)was taken to measure and calculate the average osteogenesis height (AOH) in maxillary sinus segment of the zygomatic implants, then the residual bone height, the width and morphology of the maxillary sinus floor in the buccal and palatal directions were measured. Besides, the integrity of Schneiderian membrane during implant surgery, and the general information of the patients and zygomatic implants were recorded. By comparing anatomical situations and surgical characteristics, the differences of AOH under different conditions were analyzed. Then AOH was divided into two groups (obvious osteogenesis group and non-obvious osteogenesis group) using the median as the threshold, and the influencing factors of osteogenesis were evaluated using mixed effect generalized linear model univariable and multivariable analysis.
RESULTS:
A total of 47 zygomatic implants were implanted in 24 patients. During the average follow-up period of 12.1 months, there was no implant failure, and the implant survival rate was 100%. Postoperative CBCT showed that 43 zygomatic implants had osteogenic images in the maxillary sinus segment, most of which originated from the floor of the maxillary sinus, and the median AOH was 3.1 mm [interquartile range (IQR): 4.0 mm]. In terms of maxillary sinus width, there were 31 cases (66.0%) of wide type and 16 cases (34.0%) of narrow type. In the aspect of buccal and palatal morphology, 17 cases were taper (36.2%), 20 cases were round (42.6%), and 10 cases were flat (21.3%). The median of residual bone height was 2.8 mm (IQR: 2.2 mm) before operation. Univa-riate analysis of mixed effect generalized linear model showed that postoperative obvious osteogenic rate was related to the residual bone height (OR=2.09, P=0.006). Multivariate analysis showed that the resi-dual bone height (OR=2.55, P=0.022) and the shape of a taper maxillary sinus (OR=11.44, P=0.040) had a significant impact on the postoperative obvious osteogenic rate.
CONCLUSION
The maxillary sinus floor showed osteogenic images 1 year after the zygomatic implantation surgery. Larger residual bone height and the shape of a taper maxillary sinus may be favorable factors for osteogenesis.
Humans
;
Maxillary Sinus/surgery*
;
Cone-Beam Computed Tomography
;
Retrospective Studies
;
Zygoma/diagnostic imaging*
;
Male
;
Female
;
Osteogenesis/physiology*
;
Middle Aged
;
Adult
;
Dental Implants
;
Aged
;
Dental Implantation, Endosseous/methods*
9.Application Research of mDIXON-Quant Quantitative T2* Values and FF Values in Cervical Intervertebral Disc Degeneration.
Peng LIU ; Meichen NIU ; Hong LIU
Chinese Journal of Medical Instrumentation 2025;49(1):61-66
OBJECTIVE:
To investigate the clinical value of MRI modified water-lipid separation technique (mDIXON-Quant) in terms of T2* values and fat fraction (FF) values for evaluating the degree of cervical intervertebral disc degeneration.
METHODS:
A total of 118 patients who underwent routine MRI of the cervical vertebra and the mDIXON-Quant examination in Fuyang People's Hospital from March 2019 to January 2024 were collected. The T2* values of C2/3 to C6/7 intervertebral discs and FF values of the upper and lower vertebral bodies were measured. Cervical intervertebral disc degeneration was graded according to the Pfirrmann criteria. The T2* values and FF values of different patients were compared with the Pfirrmann grades, and the correlation between T2* values, FF values, and Pfirrmann grades was analyzed by Spearman correlation.
RESULTS:
The T2* values of cervical intervertebral discs in grades I, II, III, IV, and V all showed a decreasing trend ( P<0.05). The decreasing order of FF values in the upper cervical vertebra was IV, V, III, II, and I ( F=93.28, P<0.05), and the decreasing order of FF values in the lower cervical vertebra was IV, III, V, II, and I ( F=112.037, P<0.05). Spearman correlation analysis showed that the T2* values of cervical intervertebral discs were negatively correlated with the Pfirrmann grades ( P<0.05), and the FF values of the upper and lower vertebrae were positively correlated with the Pfirrmann grades ( P<0.05).
CONCLUSION
The mDIXON-Quant technique can be used to quantify the T2* values and FF values of cervical intervertebral disc degeneration and plays an important role in accurate clinical diagnosis and evaluation of treatment effects.
Humans
;
Intervertebral Disc Degeneration/diagnostic imaging*
;
Cervical Vertebrae/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Male
;
Female
;
Middle Aged
;
Adult
;
Intervertebral Disc/diagnostic imaging*
;
Lipids
10.Accuracy Assessment of Cone-Beam CT Images for Pelvic Tumor Dose Calculation.
Bao LI ; Yongzhong CHEN ; Jun JIN ; Longjun YAN ; Xiaoyong WANG
Chinese Journal of Medical Instrumentation 2025;49(3):302-307
OBJECTIVE:
To evaluate the feasibility and accuracy of cone-beam CT (CBCT) images for radiotherapy dose calculation in pelvic tumors.
METHODS:
An improved volumetric density coverage method was used to establish CT value-relative electron density (RED) curves for CBCT images. The planning CT plans were transferred to the CBCT images, and the constructed density curves were applied to calculate doses for CBCT plans while maintaining the optimization parameters unchanged. Dose calculation deviations between the two plans were analyzed.
RESULTS:
The mean differences in dosimetric parameters for the target volume and organs at risk (OAR) between the two plans were less than 1% and 1.5%, respectively. The target conformity index (CI), homogeneity index (HI), and gamma passing rates were highly consistent, with no statistically significant differences.
CONCLUSION
CBCT images corrected by this method can be used for dose calculation in pelvic tumor radiotherapy planning.
Cone-Beam Computed Tomography/methods*
;
Humans
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Radiotherapy Dosage
;
Pelvic Neoplasms/diagnostic imaging*

Result Analysis
Print
Save
E-mail