1.Comparison of effectiveness between two surgical methods for humeral lateral condyle fractures in children.
Hailong MA ; Qingjie WU ; Fang LIU ; Zhongtuo HUA ; Sicheng ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):64-69
OBJECTIVE:
To compare the effectiveness of ultrasound-guided closed reduction with Kirschner wire fixation and open reduction with Kirschner wire fixation in the treatment of humeral lateral condyle fracture (HLCF) in children.
METHODS:
A clinical data of 53 children with HLCF admitted between May 2020 and April 2023 and met selective criteria was retrospectively analyzed. Of these, 25 cases were managed with closed reduction and Kirschner wire fixation under ultrasound guidance (closed group), while 28 cases underwent open reduction and Kirschner wire fixation (open group). There was no significant difference between the two groups in terms of gender, age, cause of injury, fracture side, fracture classification, and time from injury to operation ( P>0.05). The following variables were recorded and compared between the two groups: operation time, intraoperative fluoroscopy frequency, fracture healing time, incidence of complications, and the Flynn elbow function score at last follow-up.
RESULTS:
In the closed group, the fractures were successfully reduced under ultrasound guidance, with no nerve damage reported in either group. The operation time and intraoperative fluoroscopy frequency were significantly less in the closed group than in the open group ( P<0.05). One case of infection (Kirschner wire irritation) was observed in the closed group, while 3 cases in the open group (2 of Kirschner wire irritation and 1 of incision infection). However, the difference in the incidence of infection between the two groups was not significant ( P>0.05). All patients in both groups were followed up 6-18 months (mean, 10.2 months). X-ray examinations confirmed that fractures had healed in both groups, with no significant difference in healing time ( P>0.05). During follow-up, 5 cases of lateral humeral process formation were observed in the closed group, compared to 12 cases in the open group, although this difference was not significant ( P>0.05). At last follow-up, the excellent and good rate of elbow joint function was evaluated as 96.0% (24/25) in the closed group and 92.9% (26/28) in the open group according to the Flynn scoring criteria, with no significant difference between the two groups ( P>0.05). Both groups showed no occurrence of ossifying myositis or elbow internal/external rotation.
CONCLUSION
The effectiveness of ultrasound-guided closed reduction and Kirschner wire fixation in the treatment of HLCF in children is comparable to open reduction and Kirschner wire fixation, but the former can reduce operation time and intraoperative fluoroscopy frequency, and obtain lower the incidence of complications.
Humans
;
Humeral Fractures/diagnostic imaging*
;
Bone Wires
;
Male
;
Female
;
Child
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Child, Preschool
;
Open Fracture Reduction/methods*
;
Fracture Healing
;
Elbow Joint/surgery*
;
Adolescent
;
Closed Fracture Reduction/methods*
;
Fluoroscopy
;
Operative Time
2.Posterior minimally invasive approach for treatment of posterior wall acetabular fractures.
Wenbo LI ; Lihong LIU ; Peisheng SHI ; Yun XUE ; Wei WANG ; Jie SHI ; Chuangbing LI ; Xianqing SHI ; Xiaowen DENG ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):134-139
OBJECTIVE:
To investigate the effectiveness of posterior minimally invasive approach in the treatment of posterior wall acetabular fractures.
METHODS:
The clinical data of 17 patients with posterior wall acetabular fractures treated with posterior minimally invasive approach between March 2019 and June 2023 were retrospectively analyzed. There were 14 males and 3 females with an average age of 41 years ranging from 28 to 57 years. The causes of injury were traffic accident in 12 cases and falling from height in 5 cases. There were 3 cases complicated with posterior hip dislocation and 2 cases complicated with sciatic nerve injury. According to AO/Orthopaedic Trauma Association (AO/OTA) classification, there were 11 cases of type A1.1 and 6 cases of type A1.2. The time from injury to operation was 5-8 days, with an average of 6.2 days. The incision length, intraoperative blood loss, and operation time were recorded. The quality of posterior wall fracture reduction were evaluated by Matta criteria, and hip function were evaluated by modified Merle d'Aubign-Postel score criteria at 6 months after operation and last follow-up.
RESULTS:
The operation was successfully completed in 17 cases. The length of incision ranged from 7 to 9 cm, with an average of 8.3 cm, and all incisions healed by first intention. The intraoperative blood loss ranged from 200 to 350 mL, with an average of 281 mL. The operation time ranged from 45 to 70 minutes, with an average of 57 minutes. Two patients had sciatic nerve injury before operation, and the sciatic nerve function recovered completely at 3 months after operation; the other 15 patients had no symptoms of sciatic nerve injury after operation. All the 17 patients were followed up 14-27 months, with an average of 19.5 months. At 1 week after operation, according to the Matta criteria, anatomical reduction was achieved in 12 cases and satisfactory reduction in 5 cases, with a satisfaction rate of 100%. According to the modified Merle d'Aubign-Postel scoring system, the hip function score was 13-18 (mean, 16.1) at 6 months after operation. Among them, 5 cases were excellent, 9 were good, and 3 were fair, with an excellent and good rate of 82.4%. At last follow-up, the hip function score was 7-18 (mean, 13.7), of which 3 cases were excellent, 9 were good, 3 were fair, and 2 were poor, with an excellent and good rate of 70.6%. During the follow-up, there was no infection, failure of internal fixation, and femoral head necrosis, and heterotopic ossification occurred in 2 cases.
CONCLUSION
The posterior minimally invasive approach has the advantages of less trauma, shorter operation time, less blood loss, without cutting off the external rotator muscle. Exposure through the gluteus medius-piriformis space and piriformis-supercilium space can provide sufficient safe exposure for the posterior wall acetabulum fracture, which is a reliable alternative approach for the posterior acetabular fracture.
Humans
;
Acetabulum/surgery*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Minimally Invasive Surgical Procedures/methods*
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Fractures, Bone/diagnostic imaging*
;
Treatment Outcome
;
Operative Time
3.Treatment of irreducible intertrochanteric femoral fracture in elderly with proximal femoral nail antirotation combined with minimally invasive clamp reduction technique by Kocher pincers.
Hongwei TANG ; Yong YIN ; Yinhua MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):536-541
OBJECTIVE:
To explore the effectiveness of proximal femoral nail antirotation (PFNA) combined with minimally invasive clamp reduction technique by Kocher pincers in the treatment of irreducible intertrochanteric femoral fracture in the elderly.
METHODS:
The clinical data of 35 elderly patients with irreducible intertrochanteric femoral fractures who were treated with PFNA combined with minimally invasive clamp reduction technique by Kocher pincers between January 2016 and December 2022 were retrospectively analysed. There were 16 males and 19 females, aged from 63 to 95 years (mean, 75.2 years). The causes of injury included traffic accident in 3 cases and falling in 32 cases. The time from injury to operation was 2-11 days (mean, 3.6 days). According to AO/Orthopaedic Trauma Association (AO/OTA) classification system for intertrochanteric fractures, there were 14 cases of type A1, 18 cases of type A2, and 3 cases of type A3. According to the displacement of fracture by intraoperative fluoroscopy, there were 5 cases with only coronal displacement, 17 cases with only sagittal displacement, and 13 cases with both coronal and sagittal displacement. The operation time, intraoperative blood loss, rate of hemoglobin decline at 1 day after operation, length of hospital stay, and fracture healing time were recorded. The reduction quality of fracture during operation was evaluated according to reduction quality criteria proposed by Chang et al. The Harris scoring system was used to evaluate the hip joint function at last follow-up.
RESULTS:
The operation time was 45-105 minutes (mean, 54.4 minutes); the intraoperative blood loss was 80-300 mL (mean, 116.3 mL). The reduction quality of fracture during operation was good in 22 cases (62.9%) and acceptable in 13 cases (37.1%). The rate of hemoglobin decline at 1 day after operation ranged from 6.2% to 18.6% (mean, 10.2%); the length of hospital stay was 5-18 days (mean, 7.2 days). One case died of respiratory failure due to pulmonary infection, 2 cases were lost to follow-up, and the remaining 32 cases were followed up 6-24 months (mean, 10.6 months). All 32 patients achieved bony union and the healing time was 3-9 months (mean, 3.6 months). There was no complication such as incision infection, internal fixation failure, or coxa varus during follow-up. At last follow-up, the Harris score of hip joint was 67-96 (mean, 88.9); among them, 19 cases were excellent, 10 cases were good, 2 cases were fair, and 1 case was poor, with an excellent and good rate of 90.6%.
CONCLUSION
For the elderly patients with irreducible intertrochanteric femoral fracture, the application of PFNA combined with minimally invasive clamp reduction technique by Kocher pincers can achieve high-quality fracture reduction, which has the advantages of simple reduction operation, less trauma, and can avoid the radiation exposure of operators during maintenance reduction.
Humans
;
Male
;
Female
;
Aged
;
Minimally Invasive Surgical Procedures/methods*
;
Hip Fractures/diagnostic imaging*
;
Bone Nails
;
Aged, 80 and over
;
Retrospective Studies
;
Fracture Fixation, Intramedullary/instrumentation*
;
Middle Aged
;
Treatment Outcome
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
Femoral Fractures/surgery*
4.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
5.Effectiveness analysis of Zhang's double reverse traction reducer in minimally invasive treatment of bilateral tibial plateau fractures.
Zhanle ZHENG ; Baoheng FAN ; Zhongzheng WANG ; Rongqing REN ; Yiyang WANG ; Ning WEI ; Yingze ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(7):789-794
OBJECTIVE:
To evaluate the effectiveness and safety of minimally invasive treatment for bilateral tibial plateau fractures using the double reverse traction reducer.
METHODS:
The clinical data of 4 patients with bilateral tibial plateau fractures who met the selection criteria and treated between January 2016 and April 2024 were retrospectively analyzed. The cohort included 3 males and 1 female, aged 30-65 years (mean, 52.5 years). Injury mechanisms comprised traffic accidents (2 cases) and falls (2 cases). According to the Schatzker classification, 2 limbs were type Ⅱ and 6 were type Ⅵ. The time from injury to surgery ranged from 5 to 9 days (mean, 7 days). All patients underwent minimally invasive reduction using the double reverse traction reducer. Surgical duration, intraoperative blood loss, and hospitalization time were recorded. Functional outcomes were assessed at last follow-up using the Hospital for Special Surgery (HSS) knee score and range of motion (ROM), while fracture reduction quality was evaluated using the Rasmussen radiological score.
RESULTS:
All 4 patients successfully completed the procedure without conversion to open reduction. The total mean operation time was 80.25 minutes (range, 73-86 minutes), with a mean total intraoperative blood loss of 132.5 mL (range, 100-150 mL). The mean hospitalization time was 13.5 days (range, 11-16 days). All incisions healed primarily without neurovascular complications. X-ray film at 1 day after operation confirmed satisfactory reduction and articular surface alignment. Follow-up time ranged from 12 to 26 months (mean, 17.0 months). Fractures achieved clinical union at an average of 13 weeks (range, 12-16 weeks). No complication, such as deep vein thrombosis, joint stiffness, post-traumatic arthritis, or implant failure, was observed. At last follow-up, the mean HSS score was 92.9 (range, 90-97), mean knee ROM was 128.1° (range, 115°-135°), and mean Rasmussen radiological score was 16.4 (range, 15-19), with 2 limbs rated as excellent and 6 as good.
CONCLUSION
The double reverse traction reducer facilitates minimally invasive treatment of bilateral tibial plateau fractures with advantages including minimal trauma, shorter surgical duration, precise reduction, and fewer complications, effectively promoting fracture healing and functional recovery of the knee joint.
Humans
;
Tibial Fractures/diagnostic imaging*
;
Middle Aged
;
Male
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Female
;
Adult
;
Retrospective Studies
;
Aged
;
Traction/methods*
;
Treatment Outcome
;
Fracture Fixation, Internal/instrumentation*
;
Range of Motion, Articular
;
Operative Time
;
Tibial Plateau Fractures
6.Antegrade elastic intramedullary nailing fixation via a novel approach through proximal radius for distal radius metaphyseal-diaphyseal junction fractures in children.
Bin JIN ; Xinglei SHI ; Hailong MA ; Junchen ZHU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1155-1159
OBJECTIVE:
To investigate the surgical technique and preliminary effectiveness of closed reduction and internal fixation (CRIF) using antegrade elastic intramedullary nailing (ESIN) via a novel approach through the proximal radius for treating distal radius metaphyseal-diaphyseal junction (DRMDJ) fractures in children.
METHODS:
A retrospective analysis was conducted on 34 children with DRMDJ fractures who met the selection criteria and were treated between January 2020 and June 2023. There were 21 boys and 13 girls, aged 6-14 years (mean, 8.2 years). Injury causes included falls in 11 cases and sports-related trauma in 23 cases. Twenty-six cases were associated with ipsilateral distal ulnar fractures. All patients had failed initial closed reduction in the outpatient clinic. The time from injury to operation ranged from 1 to 15 days (mean, 4 days). All patients underwent CRIF using antegrade ESIN inserted via a novel approach at the proximal one-third of the radius. The operation time, intraoperative fluoroscopy frequency, fracture healing time, and complications were recorded. Fracture reduction was assessed immediately after operation on anteroposterior and lateral X-ray films for residual translation and angulation. Wrist function was evaluated using the modified Mayo wrist score.
RESULTS:
Surgery was successfully completed in all 34 children. CRIF with ESIN failed in 2 cases with associated ipsilateral distal ulnar fractures, requiring conversion to open reduction of the ulna. Operation time ranged from 15 to 56 minutes (mean, 21 minutes). Intraoperative fluoroscopy frequency ranged from 5 to 21 times (mean, 7 times). Immediate postoperative X-ray films showed residual translation of 0-15% on anteroposterior view and 0-10% on lateral view, and residual angulation of 0°-5° on both anteroposterior and lateral views. All children were followed up 6-18 months (mean, 12 months). There was no complication such as neurovascular injury, incision infection, or limitation of forearm rotation. Follow-up X-ray films showed no fracture displacement, implant loosening, delayed union, or nonunion. Fracture healing time ranged from 4 to 8 weeks (mean, 6 weeks). Implants were removed at 4-6 months postoperatively (mean, 5 months). At last follow-up, all fractures had achieved anatomic or near-anatomic healing. The modified Mayo wrist score ranged from 80 to 100 (mean, 94), with 27 excellent and 7 good results, yielding an excellent and good rate of 100%.
CONCLUSION
CRIF using antegrade ESIN via a novel approach through proximal radius is a safe and effective treatment for pediatric DRMDJ fractures, associated with few postoperative complications and excellent restoration of wrist function.
Humans
;
Child
;
Female
;
Male
;
Fracture Fixation, Intramedullary/instrumentation*
;
Adolescent
;
Radius Fractures/diagnostic imaging*
;
Retrospective Studies
;
Bone Nails
;
Treatment Outcome
;
Fracture Healing
;
Diaphyses/surgery*
;
Radius/surgery*
;
Operative Time
;
Closed Fracture Reduction/methods*
;
Ulna Fractures/surgery*
7.Effectiveness of double joystick technique assisted treatment of Gartland type Ⅲ supracondylar fractures of the humerus in children.
Guangyao LI ; Feng HU ; He BAI ; Wei LIU ; Dandan HAN ; Quangui CHEN ; Shaolin TAN ; Ke SHA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1160-1164
OBJECTIVE:
To evaluate the effectiveness of double joystick technique assisted closed reduction and Kirschner wire internal fixation in the treatment of Gartland type Ⅲ supracondylar fractures of the humerus (SCFH) in children.
METHODS:
A retrospective study was conducted on 28 cases of Gartland type Ⅲ SCFH with complete data available, who underwent closed reduction and Kirschner wire internal fixation with the double joystick technique between August 2022 and July 2024. There were 23 boys and 5 girls, with an average age of 6.4 years (range, 1-12 years). All fractures resulted from falls and were classified as extension-type. X-ray film showed the radial displacement of the distal fragment in 15 cases and unlar displacement in 13 cases. The interval from injury to operation was 3-36 hours (mean, 19.5 hours). X-ray film re-examination was conducted to evaluate the fracture healing, and the Baumann angle of affected elbow joint and carrying angle of bilateral elbow joints were measured. Elbow joint function was evaluated using the range of motion (flexion and extension) and the Flynn criteria. The above indicators were compared between affected and healthy sides.
RESULTS:
All operation were successfully completed. The operation time ranged from 15 to 40 minutes (mean, 25.2 minutes). The length of hospital stay was 2-5 days (mean, 3.5 days). All patients were followed up 3-24 months (mean, 11.8 months). X-ray film confirmed fracture healing in all patients, with a mean healing time of 5.4 weeks (range, 4-6 weeks). At last follow-up, the Baumann angle of the affected elbow joint was (73.50±3.46)°, and the carrying angle and the range of motion in flexion and extension of the affected elbow joint were significantly less than the contralateral side (P<0.05). According to the Flynn criteria, the elbow joint function of the affected elbow was evaluated as excellent in 25 cases and good in 3 cases, with an excellent and good rate of 100%.
CONCLUSION
The double joystick technique is a safe and effective method which can facilitate the closed reduction and Kirschner wire internal fixation of Gartland type Ⅲ SCFH in children without increasing risk of complications.
Humans
;
Male
;
Female
;
Humeral Fractures/diagnostic imaging*
;
Fracture Fixation, Internal/instrumentation*
;
Child
;
Retrospective Studies
;
Bone Wires
;
Child, Preschool
;
Fracture Healing
;
Treatment Outcome
;
Infant
;
Elbow Joint/physiopathology*
;
Range of Motion, Articular
;
Closed Fracture Reduction/methods*
8.Comparison of effectiveness of multiple metatarsal osteotomy and first metatarsophalangeal arthrodesis for severe metatarsal adductus hallux valgus deformity.
Shengyuan LAN ; Xingchen LI ; Xiangyang XU ; Yuan ZHU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1246-1250
OBJECTIVE:
To compare effectiveness of multiple metatarsal osteotomy versus first metatarsophalangeal arthrodesis in treating severe metatarsal adductus hallux valgus deformity.
METHODS:
A retrospective analysis was conducted on the clinical data of 25 patients with severe metatarsal adductus hallux valgus deformity admitted between June 2010 and May 2014 who met the selective criteria. Among them, 15 patients underwent multiple metatarsal osteotomy (osteotomy group), while 10 patients underwent first metatarsophalangeal arthrodesis (fusion group). There was no significant difference between groups ( P>0.05) in gender, age, disease duration, affected side, preoperative American Orthopaedic Foot and Ankle Society (AOFAS) score, visual analogue scale (VAS) score for pain, intermetatarsal angle (IMA), hallux valgus angle (HVA), or metatarsal adduction angle (MAA). The osteotomy group underwent fixation with screws and/or staples fixation, while the fusion group utilized anatomic fusion plates and trans-articular compression screws. The study compared the following outcome indicators between groups: operation time, pre- and post-operative differences (change values) in AOFAS scores, VAS scores, and radiographic parameters (HVA, MAA), osteotomy healing outcomes, and recurrence of hallux valgus deformity.
RESULTS:
Both surgical procedures were completed successfully. The operation time was significantly shorter in the fusion group than in the osteotomy group ( P<0.05). All patients were followed up 96-144 months (mean, 116 months). The follow-up time was (129.1±7.2) months in the osteotomy group and (104.4±8.0) months in the fusion group, with no significant difference between groups ( P>0.05). X-ray films revealed the radiographic union in two groups, and the fusion time was significantly shorter in the fusion group than in the osteotomy group ( P<0.05). At last follow-up, both groups demonstrated significant improvements in AOFAS and VAS scores compared to preoperative levels ( P<0.05). However, the differences in the change values of AOFAS and VAS scores between groups were not significant ( P>0.05). During follow-up, 3 cases (20%) of deformity recurrence occurred in the osteotomy group, while no recurrence was observed in the fusion group. There was no significant difference in the incidences of deformity recurrence between groups ( P>0.05).
CONCLUSION
For severe metatarsus adductus hallux valgus deformities, both multiple metatarsal osteotomy and first metatarsophalangeal arthrodesis can correct the deformity. The former preserves metatarsophalangeal joint mobility but demands high technical proficiency from the surgeon, involves relatively longer operation times, extended bone healing periods, and higher complication incidences. The latter procedure is relatively simpler, facilitates faster postoperative recovery, allows early weight-bearing, and yields more reliable outcomes, though it sacrifices first metatarsophalangeal joint mobility.
Humans
;
Osteotomy/methods*
;
Hallux Valgus/diagnostic imaging*
;
Retrospective Studies
;
Arthrodesis/instrumentation*
;
Treatment Outcome
;
Metatarsal Bones/diagnostic imaging*
;
Metatarsophalangeal Joint/diagnostic imaging*
;
Male
;
Female
;
Bone Screws
;
Adult
;
Middle Aged
;
Bone Plates
;
Pain Measurement
9.Measurement and clinical validation of safe distance for LC- Ⅱ screw placement using iliac oblique view.
Hongwei FU ; Ansu WANG ; Lin CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1304-1309
OBJECTIVE:
To define a safe distance range from the LC-Ⅱ screw trajectory to the apex of the greater sciatic notch based on pelvic CT measurements, and to clinically assess the feasibility of using this range under iliac oblique view combined with iliac tangential view fluoroscopy to guide screw insertion.
METHODS:
CT scans of 104 normal pelvises collected between January 2022 and February 2025 were analyzed. There were 52 males and 52 females, with a median age of 45.8 years (range, 19-76 years). The RadiAnt DICOM Viewer software was used to reconstruct coronal, sagittal, and axial sections of the potential LC-Ⅱ screw trajectory. The maximum safety distance (Dmax) and the optimal safety distance (Dopt) from this trajectory to the greater sciatic notch were measured on the coronal and sagittal views. A retrospective analysis was conducted on 21 patients with LC-Ⅱ type pelvic fractures treated with the LC-Ⅱ screws fixation. And the screws were placed within the pre-defined safe distance under guidance from the iliac oblique view and iliac tangential view. Postoperative CT scans were obtained to evaluate the accuracy of screw placement.
RESULTS:
Radiographic measurements from the 104 cases showed that Dmax ranged from 1.87 to 3.87 cm (mean, 2.79 cm), and Dopt ranged from 1.01 to 2.92 cm (mean, 1.84 cm). Both Dmax and Dopt were significantly greater in the males than in the females ( P>0.05). No significant difference was found between the left and right sides within the same gender ( P>0.05). All 21 patients successfully underwent fracture reduction and fixation, with a total of 23 LC-Ⅱscrews implanted. According to the Lonstein grading system, the screw placement accuracy was rated as excellent in 16 screws, good in 3, fair in 3, and poor in 1, with an excellent and good rate of 82.6%.
CONCLUSION
Utilizing a CT-defined safe distance range from the screw trajectory to the greater sciatic notch, and adhering to this range under iliac oblique view combined with iliac tangential view fluoroscopy, enables the accurate and precise placement of LC-Ⅱ screws.
Humans
;
Male
;
Female
;
Middle Aged
;
Bone Screws
;
Adult
;
Tomography, X-Ray Computed/methods*
;
Aged
;
Ilium/surgery*
;
Pelvic Bones/diagnostic imaging*
;
Fracture Fixation, Internal/instrumentation*
;
Retrospective Studies
;
Fluoroscopy
;
Fractures, Bone/diagnostic imaging*
;
Young Adult
10.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*

Result Analysis
Print
Save
E-mail