1.Cardiac Structural and Functional Features in Patients With Type 2 Diabetes Mellitus and Heart Failure With Preserved Ejection Fraction:A Study Based on Propensity Score Matching.
Ke-Ling PENG ; Yong-Ming LIU ; Xiao-Yan JIA ; Hua WANG ; Chun-Li GOU ; Li-Li XUE ; Quan ZOU ; Wen-Jun ZHANG
Acta Academiae Medicinae Sinicae 2023;45(2):264-272
Objective To investigate the cardiac structural and functional characteristics in the patients with heart failure with preserved ejection fraction (HFpEF) and type 2 diabetes mellitus (T2DM),and predict the factors influencing the characteristics. Methods A total of 783 HFpEF patients diagnosed in the Department of Geriatric Cardiology,the First Hospital of Lanzhou University from April 2009 to December 2020 were enrolled in this study.Echocardiography and tissue Doppler technique were employed to evaluate cardiac structure and function.According to the occurrence of T2DM,the patients were assigned into a HFpEF+T2DM group (n=332) and a HFpEF group (n=451).Propensity score matching (PSM)(in a 1∶1 ratio) was adopted to minimize confounding effect.According to urinary albumin excretion rate (UAER),the HFpEF+T2DM group was further divided into three subgroups with UAER<20 μg/min,of 20-200 μg/min,and>200 μg/min,respectively.The comorbidities,symptoms and signs,and cardiac structure and function were compared among the groups to clarify the features of diabetes related HFpEF.Multivariate linear regression was conducted to probe the relationship of systolic blood pressure,blood glucose,glycosylated hemoglobin,and UARE with cardiac structural and functional impairment. Results The HFpEF+T2DM group had higher prevalence of hypertension (P=0.001) and coronary heart disease (P=0.036),younger age (P=0.020),and larger body mass index (P=0.005) than the HFpEF group,with the median diabetic course of 10 (3,17) years.After PSM,the prevalence of hypertension and coronary heart disease,body mass index,and age had no significant differences between the two groups(all P>0.05).In addition,the HFpEF+T2DM group had higher interventricular septal thickness (P=0.015),left ventricular posterior wall thickness (P=0.040),and left ventricular mass (P=0.012) and lower early diastole velocity of mitral annular septum (P=0.030) and lateral wall (P=0.011) than the HFpEF group.Compared with the HFpEF group,the HFpEF+T2DM group showed increased ratio of early diastolic mitral filling velocity to early diastolic mitral annular velocity (E/e') (P=0.036).Glycosylated hemoglobin was correlated with left ventricular mass (P=0.011),and the natural logarithm of UAER with interventricular septal thickness (P=0.004),left ventricular posterior wall thickness (P=0.006),left ventricular mass (P<0.001),and E/e' ratio (P=0.049). Conclusion The patients with both T2DM and HFpEF have thicker left ventricular wall,larger left ventricular mass,more advanced left ventricular remodeling,severer impaired left ventricular diastolic function,and higher left ventricular filling pressure than the HFpEF patients without T2DM.Elevated blood glucose and diabetic microvascular diseases might play a role in the development of the detrimental structural and functional changes of the heart.
Humans
;
Aged
;
Heart Failure/diagnosis*
;
Diabetes Mellitus, Type 2
;
Stroke Volume
;
Glycated Hemoglobin
;
Blood Glucose
;
Propensity Score
;
Ventricular Function, Left
;
Hypertension
2.Research progress on minimally invasive and non-invasive blood glucose detection methods.
Xinyu GAO ; Zekai XU ; Liqun CHEN
Journal of Biomedical Engineering 2023;40(2):365-372
Blood glucose monitoring has become the weakest point in the overall management of diabetes in China. Long-term monitoring of blood glucose levels in diabetic patients has become an important means of controlling the development of diabetes and its complications, so that technological innovations in blood glucose testing methods have far-reaching implications for accurate blood glucose testing. This article discusses the basic principles of minimally invasive and non-invasive blood glucose testing assays, including urine glucose assays, tear assays, methods of extravasation of tissue fluid, and optical detection methods, etc., focuses on the advantages of minimally invasive and non-invasive blood glucose testing methods and the latest relevant results, and summarizes the current problems of various testing methods and prospects for future development trends.
Humans
;
Blood Glucose
;
Blood Glucose Self-Monitoring/methods*
;
Diabetes Mellitus/diagnosis*
;
Monitoring, Physiologic/methods*
;
Tears
3.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
4.Decreasing complexity of glucose time series derived from continuous glucose monitoring is correlated with deteriorating glucose regulation.
Cheng LI ; Xiaojing MA ; Jingyi LU ; Rui TAO ; Xia YU ; Yifei MO ; Wei LU ; Yuqian BAO ; Jian ZHOU ; Weiping JIA
Frontiers of Medicine 2023;17(1):68-74
Most information used to evaluate diabetic statuses is collected at a special time-point, such as taking fasting plasma glucose test and providing a limited view of individual's health and disease risk. As a new parameter for continuously evaluating personal clinical statuses, the newly developed technique "continuous glucose monitoring" (CGM) can characterize glucose dynamics. By calculating the complexity of glucose time series index (CGI) with refined composite multi-scale entropy analysis of the CGM data, the study showed for the first time that the complexity of glucose time series in subjects decreased gradually from normal glucose tolerance to impaired glucose regulation and then to type 2 diabetes (P for trend < 0.01). Furthermore, CGI was significantly associated with various parameters such as insulin sensitivity/secretion (all P < 0.01), and multiple linear stepwise regression showed that the disposition index, which reflects β-cell function after adjusting for insulin sensitivity, was the only independent factor correlated with CGI (P < 0.01). Our findings indicate that the CGI derived from the CGM data may serve as a novel marker to evaluate glucose homeostasis.
Humans
;
Glucose
;
Blood Glucose
;
Insulin Resistance/physiology*
;
Diabetes Mellitus, Type 2/diagnosis*
;
Blood Glucose Self-Monitoring
;
Time Factors
;
Insulin
5.Associations between glycated hemoglobin and glucose indicators in adults in areas at different altitude in China.
Xiao ZHANG ; Mei ZHANG ; Chun LI ; Zheng Jing HUANG ; Meng Ting YU ; Li Min WANG
Chinese Journal of Epidemiology 2023;44(3):401-407
Objective: To explore the associations of glycated hemoglobin (HbA1c) with FPG and oral glucose tolerance test 2-hour (OGTT-2 h) in areas at different altitude in China. Methods: Subjects who participated in 2018-2019 China Chronic Disease and Risk Factor Surveillance and had no prior type 2 diabetes diagnosis were included. Subsequently, they were categorized into three groups based on altitude of living area (<2 000, 2 000- and ≥3 000 m). With adjustment for intracluster correlation, multivariable linear regression analysis was performed to evaluate the associations of HbA1c with FPG and OGTT-2 h in the context of HbA1c was normal (<5.7%) or abnormal (≥5.7%). Furthermore, the shape of relationships between HbA1c and glucose indicators was examined using restricted cubic spline. Finally, receiver operating characteristic curve was used to evaluate the diagnostic performance of HbA1c for diabetes. Results: A total of 157 277 subjects were included in the analysis. While FPG and OGTT-2 h levels gradually decreased with increase of altitude, HbA1c level was similar among the three groups. When HbA1c was <5.7%, its association with FPG and OGTT-2 h was weak and no obvious difference was observed among the three groups. When HbA1c was ≥5.7%, the FPG and OGTT-2 h increased by 15.45% (95%CI:14.71%- 16.18%) and 24.54% (95%CI:23.18%-25.91%) respectively per one standard deviation increase in HbA1c in group in area at altitude <2 000 m. However, the FPG and OGTT-2 h increased by 13.08% (95%CI:10.46%-15.76%) and 21.72% (95%CI:16.39%-27.31%), respectively, in group in area at altitude 2 000- m, and increased by 11.41% (95%CI:9.32%-13.53%) and 20.03% (95%CI:15.38%- 24.86%), respectively, in group of altitude ≥3 000 m. The restricted cubic spline indicated that the curve showing the association of HbA1c with FPG and OGTT-2 h was flat when HbA1c was <5.7%, but showed a positive linear relationship when HbA1c was ≥5.7%. The area under curve for detecting diabetes was 0.808 (95%CI:0.803-0.812) in group of altitude <2 000 m and 0.728 (95%CI:0.660-0.796, P=0.022) in group of altitude ≥3 000 m. The relevant optimal cutoff value of HbA1c was 5.7%, with a sensitivity of 65.4% and a specificity of 83.0%, and 6.0%, with a sensitivity of 48.3% and a specificity of 93.7%, respectively. Conclusions: When HbA1c was ≥5.7%, the association between HbA1c and glucose indicators became weaker as the increase of altitude. In the area at altitude ≥3 000 m, it may not be appropriate to use HbA1c in the diagnosis of diabetes.
Adult
;
Humans
;
Glycated Hemoglobin
;
Diabetes Mellitus, Type 2/diagnosis*
;
Blood Glucose/analysis*
;
Glucose
;
Altitude
;
Fasting
;
China/epidemiology*
;
Diabetes Mellitus/epidemiology*
6.Prevalence of maturity-onset diabetes of the young in phenotypic type 2 diabetes in young adults: a nationwide, multi-center, cross-sectional survey in China.
Yan CHEN ; Jing ZHAO ; Xia LI ; Zhiguo XIE ; Gan HUANG ; Xiang YAN ; Houde ZHOU ; Li ZHENG ; Tao XU ; Kaixin ZHOU ; Zhiguang ZHOU
Chinese Medical Journal 2023;136(1):56-64
BACKGROUND:
Maturity-onset diabetes of the young (MODY) is the most common monogenic diabetes. The aim of this study was to assess the prevalence of MODY in phenotypic type 2 diabetes (T2DM) among Chinese young adults.
METHODS:
From April 2015 to October 2017, this cross-sectional study involved 2429 consecutive patients from 46 hospitals in China, newly diagnosed between 15 years and 45 years, with T2DM phenotype and negative for standardized glutamic acid decarboxylase antibody at the core laboratory. Sequencing using a custom monogenic diabetes gene panel was performed, and variants of 14 MODY genes were interpreted as per current guidelines.
RESULTS:
The survey determined 18 patients having genetic variants causing MODY (6 HNF1A , 5 GCK , 3 HNF4A , 2 INS , 1 PDX1 , and 1 PAX4 ). The prevalence of MODY was 0.74% (95% confidence interval [CI]: 0.40-1.08%). The clinical characteristics of MODY patients were not specific, 72.2% (13/18) of them were diagnosed after 35 years, 47.1% (8/17) had metabolic syndrome, and only 38.9% (7/18) had a family history of diabetes. No significant difference in manifestations except for hemoglobin A1c levels was found between MODY and non-MODY patients.
CONCLUSION
The prevalence of MODY in young adults with phenotypic T2DM was 0.74%, among which HNF1A -, GCK -, and HNF4A -MODY were the most common subtypes. Clinical features played a limited role in the recognition of MODY.
Humans
;
Diabetes Mellitus, Type 2/diagnosis*
;
Cross-Sectional Studies
;
Mutation
;
Prevalence
;
Phenotype
7.Salivary biomarkers: novel noninvasive tools to diagnose chronic inflammation.
Paola DONGIOVANNI ; Marica MERONI ; Sara CASATI ; Riccardo GOLDONI ; Douglas Vieira THOMAZ ; Nermin Seda KEHR ; Daniela GALIMBERTI ; Massimo DEL FABBRO ; Gianluca M TARTAGLIA
International Journal of Oral Science 2023;15(1):27-27
Several chronic disorders including type 2 diabetes (T2D), obesity, heart disease and cancer are preceded by a state of chronic low-grade inflammation. Biomarkers for the early assessment of chronic disorders encompass acute phase proteins (APP), cytokines and chemokines, pro-inflammatory enzymes, lipids and oxidative stress mediators. These substances enter saliva through the blood flow and, in some cases, there is a close relation between their salivary and serum concentration. Saliva can be easily collected and stored with non-invasive and cost-saving procedures, and it is emerging the concept to use it for the detection of inflammatory biomarkers. To this purpose, the present review aims to discuss the advantages and challenges of using standard and cutting-edge techniques to discover salivary biomarkers which may be used in diagnosis/therapy of several chronic diseases with inflammatory consequences with the pursuit to possibly replace conventional paths with detectable soluble mediators in saliva. Specifically, the review describes the procedures used for saliva collection, the standard approaches for the measurement of salivary biomarkers and the novel methodological strategies such as biosensors to improve the quality of care for chronically affected patients.
Humans
;
Diabetes Mellitus, Type 2/diagnosis*
;
Biomarkers
;
Cytokines
;
Inflammation/diagnosis*
;
Oxidative Stress
8.Association between hemoglobin glycation index and 5-year major adverse cardiovascular events: the REACTION cohort study.
Yuhan WANG ; Hongzhou LIU ; Xiaodong HU ; Anping WANG ; Anning WANG ; Shaoyang KANG ; Lingjing ZHANG ; Weijun GU ; Jingtao DOU ; Yiming MU ; Kang CHEN ; Weiqing WANG ; Zhaohui LYU
Chinese Medical Journal 2023;136(20):2468-2475
BACKGROUND:
The hemoglobin glycation index (HGI) was developed to quantify glucose metabolism and individual differences and proved to be a robust measure of individual glycosylated hemoglobin (HbA1c) bias. Here, we aimed to explore the relationship between different HGIs and the risk of 5-year major adverse cardiovascular events (MACEs) by performing a large multicenter cohort study in China.
METHODS:
A total of 9791 subjects from the Risk Evaluation of Cancers in Chinese Diabetic Individuals: a Longitudinal Study (the REACTION study) were divided into five subgroups (Q1-Q5) with the HGI quantiles (≤5th, >5th and ≤33.3th, >33.3th and ≤66.7th, >66.7th and ≤95th, and >95th percentile). A multivariate logistic regression model constructed by the restricted cubic spline method was used to evaluate the relationship between the HGI and the 5-year MACE risk. Subgroup analysis between the HGI and covariates were explored to detect differences among the five subgroups.
RESULTS:
The total 5-year MACE rate in the nationwide cohort was 6.87% (673/9791). Restricted cubic spline analysis suggested a U-shaped correlation between the HGI values and MACE risk after adjustment for cardiovascular risk factors ( χ2 = 29.5, P <0.001). After adjustment for potential confounders, subjects with HGIs ≤-0.75 or >0.82 showed odds ratios (ORs) for MACE of 1.471 (95% confidence interval [CI], 1.027-2.069) and 2.222 (95% CI, 1.641-3.026) compared to subjects with HGIs of >-0.75 and ≤-0.20. In the subgroup with non-coronary heart disease, the risk of MACE was significantly higher in subjects with HGIs ≤-0.75 (OR, 1.540 [1.039-2.234]; P = 0.027) and >0.82 (OR, 2.022 [1.392-2.890]; P <0.001) compared to those with HGIs of ≤-0.75 or >0.82 after adjustment for potential confounders.
CONCLUSIONS
We found a U-shaped correlation between the HGI values and the risk of 5-year MACE. Both low and high HGIs were associated with an increased risk of MACE. Therefore, the HGI may predict the 5-year MACE risk.
Humans
;
Cohort Studies
;
Longitudinal Studies
;
Diabetes Mellitus, Type 2/diagnosis*
;
Maillard Reaction
;
Glycated Hemoglobin
;
Cardiovascular Diseases
9.Non-alcoholic fatty liver disease screening in type 2 diabetes mellitus: A cost-effectiveness and price threshold analysis.
Bryan Peide CHOO ; George Boon Bee GOH ; Sing Yi CHIA ; Hong Choon OH ; Ngiap Chuan TAN ; Jessica Yi Lyn TAN ; Tiing Leong ANG ; Yong Mong BEE ; Yu Jun WONG
Annals of the Academy of Medicine, Singapore 2022;51(11):686-694
INTRODUCTION:
The cost-effectiveness of screening asymptomatic non-alcoholic fatty liver disease (NAFLD) patients remains debatable, with current studies assuming lifelong benefits of NAFLD screening while neglecting cardiovascular outcomes. This study aims to assess the cost-effectiveness of NAFLD screening among type 2 diabetes mellitus (T2DM) patients, and to establish a price threshold for NAFLD treatment, when it becomes available.
METHOD:
A Markov model was constructed comparing 4 screening strategies (versus no screening) to identify NAFLD with advanced fibrosis among T2DM patients: fibrosis-4 (FIB-4), vibration-controlled transient elastography (VCTE), FIB-4 and VCTE (simultaneous), and FIB-4 and VCTE (sequential). Sensitivity analyses and price threshold analyses were performed to assess parameter uncertainties in the results.
RESULTS:
VCTE was the most cost-effective NAFLD screening strategy (USD24,727/quality-adjusted life year [QALY]), followed by FIB-4 (USD36,800/QALY), when compared to no screening. Probabilistic sensitivity analysis revealed a higher degree of certainty for VCTE as a cost-effective strategy compared to FIB-4 (90.7% versus 73.2%). The duration of expected screening benefit is the most influential variable based on incremental cost-effectiveness ratio tornado analysis. The minimum duration of screening benefit for NAFLD screening to be cost-effective was at least 2.6 years. The annual cost of NAFLD treatment should be less than USD751 for NAFLD screening to be cost-effective.
CONCLUSION
Both VCTE and FIB-4 are cost-effective NAFLD screening strategies among T2DM patients in Singapore. However, given the lack of access to VCTE at primacy care and potential budget constraints, FIB-4 can also be considered for NAFLD screening among T2DM patients in Singapore.
Humans
;
Non-alcoholic Fatty Liver Disease/diagnosis*
;
Cost-Benefit Analysis
;
Diabetes Mellitus, Type 2/diagnosis*
;
Research
;
Fibrosis
10.Expression of zinc transporter 8 in Saccharomyces cerevisiae and its antigenicity analysis.
Shijing WU ; Jingwen QIAN ; Yuanxing ZHANG ; Qin LIU
Chinese Journal of Biotechnology 2022;38(9):3344-3352
Zinc transporter 8 (ZnT8) is an important candidate antigen for type Ⅰ diabetes. The autoantibody detection kit based on ZnT8 can be used to help diagnose type Ⅰ diabetes, and the related products have been launched in Europe and the United States. Since the recombinant production system of active ZnT8 has not been established in China, this key raw material is heavily dependent on imports. We used Saccharomyces cerevisiae to carry out the recombinant expression of ZnT8. First, multiple antigenic forms of ZnT8 were designed as C-terminal haploid (C), C-terminal diploid (C-C), and N-terminal and C-terminal concatemers (N-C). The proteins were expressed, purified and tested for antigenicity by bridging-type ELISA. The serum of 13 patients with type Ⅰ diabetes and the serum of 16 healthy volunteers were detected. C, N-C, and C-C proteins had similar detection rates, which were 53.8% (7/13), 61.5% (8/13) and 53.8% (7/13). The specificity of the three groups was 100% (16/16). The detection value on positive samples P3, P4, and P8 increased by more than 90%, indicating better serum antibody recognition ability. Finally, N-C protein was selected for further serum sample testing, and the test results were characterized by receiver operating characteristic (ROC) curve for sensitivity and specificity. Compared with imported gold standard antigen, the sensitivity was 76.9% (10/13) and the specificity was 87.5% (14/16). There was no significant difference in the sensitivity of the method, but the specificity needed to be improved. In conclusion, the ZnT8 N-terminal and C-terminal concatemer protein developed based on S. cerevisiae expression system is expected to be a key alternative raw material in the development of in vitro diagnostic reagents for type Ⅰ diabetes.
Antigens
;
Autoantibodies
;
Diabetes Mellitus, Type 1/diagnosis*
;
Enzyme-Linked Immunosorbent Assay
;
Humans
;
Saccharomyces cerevisiae/genetics*
;
Zinc Transporter 8/genetics*

Result Analysis
Print
Save
E-mail