1.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
2.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
3.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
4.A case report of flow diverters grafting for the treatment of neurofibromatosis type Ⅰ-related pediatric intracranial aneurysm
Lin SHI ; Bingbo LYU ; Baoxin REN ; Min WANG ; Dezhou SUN ; Donghai WANG
Chinese Journal of Cerebrovascular Diseases 2024;21(7):472-475
Intracranial aneurysms in children are rare in clinical practice.Its pathogenesis is not clear,and the treatment method has many controversies.The authors reported a case of pediatric intracranial aneurysms associated with neurofibromatosis type Ⅰ treated with two flow diverters,and reviewed relevant literatures,hoping to provide a useful reference for exploring the treatment of pediatric intracranial aneurysms.
5.Influencing factors of medical exposure frequency for community residents
Yuli CAO ; Yinping SU ; Hui XU ; Quanfu SUN ; Jinsheng CHENG
Chinese Journal of Radiological Health 2023;32(2):119-124
Objective To obtain the medical exposure frequency data of residents through a questionnaire survey on mobile phone networks in the community, and to analyze the main influencing factors. Methods A snowball sampling method was used to expand the sampling from medical staff in a county hospital to the community. The questionnaire included personal information such as occupation category, type of medical insurance, and education level as well as basic radiation-related knowledge and medical exposure type and frequency of respondents received in 2021. A logistic regression model was used to analyze the influencing factors of medical exposure. Results A total of 223 respondents were investigated, and 12.56% of them received radiological diagnosis and radiotherapy in 2021. The proportion of males receiving medical exposure was significantly higher than that of females (19.64% vs 10.18%). The likelihood of the person receiving medical exposure increased considerably with age, with the proportion of residents receiving medical exposure at 20, 30, 40, and 50 years of age being 6.25%, 7.95%, 19.23%, and 33.33%, respectively. Of persons who received medical exposure, 57.14% underwent CT scans. Persons participating in the new rural cooperative medical system were likely less to receive radiological diagnosis and radiotherapy than urban workers and residents (OR = 0.55, CI:0.13-2.23, P > 0.05). Conclusion Questionnaire survey in the community can obtain more information about the medical exposure of residents, and age and type of medical insurance are important factors affecting the frequency of medical exposure.
6.Single-Cell RNA Sequencing of Bone Marrow Mesenchymal Stem Cells from the Elderly People
Dezhou ZHU ; Jie GAO ; Chengxuan TANG ; Zheng XU ; Tiansheng SUN
International Journal of Stem Cells 2022;15(2):173-182
Background and Objectives:
Bone marrow mesenchymal stem cells (BMSCs) show considerable promise in regenerative medicine. Many studies demonstrated that BMSCs cultured in vitro were highly heterogeneous and composed of diverse cell subpopulations, which may be the basis of their multiple biological characteristics. However, the exact cell subpopulations that make up BMSCs are still unknown.
Methods:
and Results: In this study, we used single-cell RNA sequencing (scRNA-Seq) to divide 6,514 BMSCs into three clusters. The number and corresponding proportion of cells in clusters 1 to 3 were 3,766 (57.81%), 1,720 (26.40%), and 1,028 (15.78%). The gene expression profile and function of the cells in the same cluster were similar. The vast majority of cells expressed the markers defining BMSCs by flow cytometry and gene expression analysis. Each cluster had at least 20 differentially expressed genes (DEGs). We conducted Gene Ontology enrichment analysis on the top 20 DEGs of each cluster and found that the three clusters had different functions, which were related to self-renewal, multilineage differentiation and cytokine secretion, respectively. In addition, the function of the top 20 DEGs of each cluster was checked by the National Center for Biotechnology Information gene database to further verify our hypothesis.
Conclusions
This study indicated that scRNA-Seq can be used to divide BMSCs into different subpopulations, demon-strating the heterogeneity of BMSCs.
7.Coma in spontaneous intracranial hypotension complicated with subdural hematoma: a case report
Zhen WANG ; Yanfang DAI ; Yanhong AN ; Yanhui MA ; Jie WU ; Dezhou QI ; Jingjing SUN ; Hong YE ; Ran GAO ; Junjie LI ; Liyong WU
Chinese Journal of Neurology 2022;55(4):349-353
Spontaneous intracranial hypotension can frequently result in several complications including subdural hygroma, subdural hematoma and cerebral venous thrombosis, but coma rarely. A case of spontaneous intracranial hypotension presented with orthostatic headaches was described. He experienced somnolence, disorientation, incontinence, and then coma, though received conservative treatment. Brain imaging demonstrated acute-on-chronic subdural hematoma, magnetic resonance myelography using heavily T 2-weighted fast spin-echo pulse sequences showed spinal longitudinal extradural collection, and magnetic resonance myelography with intrathecal gadolinium revealed cerebrospinal fluid leak at the level of T 6, T 7. The patient recovered consciousness after surgical evacuation of the hematoma, and the headache disappeared after a targeted epidural blood patch. The hematoma resolved 2 months later and the patient kept free from headache during follow-up.
8.UHPLC-Q-Exactive Orbitrap MS/MS-based rapid identification of chemical components in substance benchmark of Kaixin San.
Hao-Ran LI ; Ping-Ping DONG ; Hua-Jian LI ; Jing XU ; Hong WANG ; Yi-Fang CUI ; Zhi-Qiang SUN ; Peng GAO ; Jia-Yu ZHANG
China Journal of Chinese Materia Medica 2022;47(4):938-950
Ultra-performance liquid chromatography-quadrupole-electrostatic field Orbitrap mass spectrometry(UHPLC-Q-Exactive Orbitrap MS/MS) was used for rapid identification of the chemical components in Kaixin San substance benchmark. The gradient elution was performed through a Waters ACQUITY~(TM) BEH C_(18) column(2.1 mm×150 mm, 1.7 μm) with water-acetonitrile as mobile phase, a column temperature of 30 ℃, a flow rate of 0.3 mL·min~(-1), and a sample size of 1 μL. The scanning was performed in the negative ion mode. The complex component groups in Kaixin San substance benchmark were quickly and accurately identified and clearly assigned based on the comparison of the retention time and MS data with those of the reference substance as well as the relative molecular weight of the same or similar components in the mass spectrum database and literature. A total of 77 compounds were identified, including 26 saponins, 13 triterpenoid acids, 20 oligosaccharide esters, 5 xanthones, and 13 other compounds. The qualitative method established in this study can systematically, accurately, and quickly identify the chemical components in Kaixin San substance benchmark, which can provide a basis for the further analysis of its active components in vivo and the establishment of its quality control system.
Benchmarking
;
Chromatography, High Pressure Liquid/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Tandem Mass Spectrometry/methods*
9.Expert Consensus for Thermal Ablation of Pulmonary Subsolid Nodules (2021 Edition).
Xin YE ; Weijun FAN ; Zhongmin WANG ; Junjie WANG ; Hui WANG ; Jun WANG ; Chuntang WANG ; Lizhi NIU ; Yong FANG ; Shanzhi GU ; Hui TIAN ; Baodong LIU ; Lou ZHONG ; Yiping ZHUANG ; Jiachang CHI ; Xichao SUN ; Nuo YANG ; Zhigang WEI ; Xiao LI ; Xiaoguang LI ; Yuliang LI ; Chunhai LI ; Yan LI ; Xia YANG ; Wuwei YANG ; Po YANG ; Zhengqiang YANG ; Yueyong XIAO ; Xiaoming SONG ; Kaixian ZHANG ; Shilin CHEN ; Weisheng CHEN ; Zhengyu LIN ; Dianjie LIN ; Zhiqiang MENG ; Xiaojing ZHAO ; Kaiwen HU ; Chen LIU ; Cheng LIU ; Chundong GU ; Dong XU ; Yong HUANG ; Guanghui HUANG ; Zhongmin PENG ; Liang DONG ; Lei JIANG ; Yue HAN ; Qingshi ZENG ; Yong JIN ; Guangyan LEI ; Bo ZHAI ; Hailiang LI ; Jie PAN
Chinese Journal of Lung Cancer 2021;24(5):305-322
"The Expert Group on Tumor Ablation Therapy of Chinese Medical Doctor Association, The Tumor Ablation Committee of Chinese College of Interventionalists, The Society of Tumor Ablation Therapy of Chinese Anti-Cancer Association and The Ablation Expert Committee of the Chinese Society of Clinical Oncology" have organized multidisciplinary experts to formulate the consensus for thermal ablation of pulmonary subsolid nodules or ground-glass nodule (GGN). The expert consensus reviews current literatures and provides clinical practices for thermal ablation of GGN. The main contents include: (1) clinical evaluation of GGN, (2) procedures, indications, contraindications, outcomes evaluation and related complications of thermal ablation for GGN and (3) future development directions.
.
10.Single cell RNA sequencing of bone marrow mononuclear cells from elderly patients with hip fracture
Dezhou ZHU ; Jie GAO ; Zhijie ZHENG ; Yun LAN ; Zheng XU ; Jianzheng ZHANG ; Zhi LIU ; Tiansheng SUN
Chinese Journal of Orthopaedic Trauma 2021;23(6):519-525
Objective:To determine whether subpopulations may exist which are related to regulation of immunization or inflammation in bone marrow mononuclear cells (BMMNCs) from 2 elderly patients with hip fracture and whether there might be any difference in the subpopulations between them.Methods:Two elderly patients with hip fracture were enrolled in this study. Their venous blood was harvested to determine subpopulations of complement (C)3, C4, interleukins (IL)-2, IL-6, IL-10, and lymphocytes. Single cell RNA sequencing (scRNA-Seq) was used to group their BMMNCs. Gene ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) analyses were performed of the top 20 differentially expressed genes for each subpopulation to judge the main function of each subpopulation. The subpopulations and the key genes related to regulation of immunization or inflammation were found out. The relationships were explored between subpopulations and prognosis of the patients.Results:By the venous blood indexes, IL-10 was slightly high in patient A; C3 below normal, C4 close to the lower normal limit, IL-2, IL-6 and IL-10 were significantly high, CD8 +T % was low, and CD4 +/CD8 + high in patient B. After scRNA-Seq and bioinformatics analyses, the BMMNCs in the 2 patients were divided into 5 subpopulations. GO and KEGG enrichment analyses showed that the functions of subpopulation 2 and subpopulation 4 were related to immunization or inflammation. CCL4, CCL5, LTB and CXCR4 in subpopulation 2 and C1QA, C1QB, CD14 and SPP1 in subpopulation 4 were related to the regulation of immunization or inflammation. The final prognosis of patient A was much better. The proportions of BMMNCs involved in subpopulation 2 and subpopulation 4 from patient A were higher than those from patient B [47.00% (1,431/3,045) versus 29.28% (882/3,012); 5.88% (179/3,045) versus 3.85% (116/3,012)]. Conclusions:The BMMNCs from elderly patients with hip fracture can be divided into subpopulations by scRNA-Seq. Some of the subpopulations may be related to regulation of immunization or inflammation, which may affect the post-injury immune inflammatory state and prognosis of the patients.


Result Analysis
Print
Save
E-mail