1.Evaluation of the accuracy of three-dimensional data acquisition from liquid- interference surfaces assisted by a scanner head with a compressed airflow system.
Xinkai XU ; Jianjiang ZHAO ; Sukun TIAN ; Zhongning LIU ; Xiaoyi ZHAO ; Xiaobo ZHAO ; Tengfei JIANG ; Xiaojun CHEN ; Chao MA ; Yuchun SUN
Journal of Peking University(Health Sciences) 2025;57(1):121-127
OBJECTIVE:
To quantitatively evaluate the accuracy of data obtained from liquid-interference surfaces using an intraoral 3D scanner (IOS) integrated with a compressed airflow system, so as to provide clinical proof of accuracy for the application of the compressed airflow system-based scanning head in improving data quality on liquid-interference surfaces.
METHODS:
The study selected a standard model as the scanning object, adhering to the "YY/T 1818-2022 Dental Science Intraoral Digital Impression Scanner" guidelines, a standard that defined parameters for intraoral scanning. To establish a baseline for accuracy, the ATOS Q 12M scanner, known for its high precision, was used to generate true reference values. These true values served as the benchmark for evaluating the IOS performance. Building on the design of an existing scanner, a new scanning head was developed to integrate with a compressed airflow system. This new design aimed to help the IOS capture high-precision data on surfaces where liquid-interference, such as saliva, might otherwise degrade scanning accuracy. The traditional scanning method, without airflow assistance, was employed as a control group for comparison. The study included five groups in total, one control group and four experimental groups, to investigate the effects of scanning lens obstruction, airflow presence, liquid media, and the use of the new scanning head on scanning process and accuracy. Each group underwent 15 scans, generating ample data for a robust statistical comparison. By evaluating trueness and precision in each group, the study assessed the impact of the compressed airflow system on the accuracy of IOS data collected from liquid-interference surfaces. Additionally, we selected Elite and Primescan scanners as references for numerical accuracy values.
RESULTS:
The scanning accuracy on liquid-interference surfaces was significantly reduced in terms of both trueness and precision [Trueness: 18.5 (6.5) vs. 38.0 (6.7), P < 0.05; Precision: 19.1 (8.5) vs. 31.7 (15.0), P < 0.05]. The use of the new scanning head assisted by the compressed airflow system significantly improved the scanning accuracy [Trueness: 22.3(7.6) vs. 38.0 (6.7), P < 0.05; Precision: 25.8 (9.6) vs. 31.7 (15.0), P < 0.05].
CONCLUSION
The scanning head based on the compressed airflow system can assist in improving the accuracy of data obtained from liquid-interference surfaces by the IOS.
Imaging, Three-Dimensional/methods*
;
Humans
;
Dental Impression Technique/instrumentation*
2.Application of individual light-curing resin tray as edge plastic material in complete denture modulo.
Mei CHAI ; Xuyan TANG ; Guangku LIANG
Journal of Central South University(Medical Sciences) 2015;40(12):1352-1356
OBJECTIVE:
To investigate clinical effect of individual light-curing resin tray as edge plastic material in complete denture modulo.
METHODS:
A total of 30 patients with poor condition for alveolar ridge of mandible were chosen individual tray with individual light-curing resin tray for material edge shaping or traditional individual impression tray for edge shaping cream to produce complete denture. The operability, questionnaire about denture retention, comfort, mucosal cases and chewing function in the process of shaping the edge were investigated three months later after wearing dentures.
RESULTS:
There was no significant difference in retention, comfort, mucosa and the chewing function between the two mandibular denture impression methods. However, the patients with individual light-curing resin tray as edge shaping material felt better in the process than that in the patients with die-cream as the edge shaping material (P<0.05). Furthermore, the manipulation with individual light-curing resin tray as edge shaping material is easy for doctor.
CONCLUSION
Although the clinical effect of Individual light-curing resin tray material as the edge shaping material is equal to that of impression cream, it saves time and human resource. Moreover, it is more acceptable for the patients and thus it can be spread in clinics.
Acrylic Resins
;
Dental Impression Materials
;
Dental Impression Technique
;
Denture, Complete
;
Humans
;
Light-Curing of Dental Adhesives
;
instrumentation
3.Inflatable hollow obturator prostheses for patients undergoing an extensive maxillectomy: a case report.
Yue-Zhong HOU ; Zhi HUANG ; Hong-Qiang YE ; Yong-Sheng ZHOU
International Journal of Oral Science 2012;4(2):114-118
The presence of a large palatal or maxillary defect after partial or total maxillectomy for tumor, trauma or congenital deformation poses a challenge to prosthodontists, particularly when the use of an implant cannot be considered. This case report described the use of an air valve in a hollow silicone obturator to manufacture an inflatable obturator that could be extended further into undercut area to retain itself. The inflatable obturator exhibited adequate retention, stability and border sealing, thereby improving the masticatory,pronunciation and swallowing functions of patients. It may be a suitable alternative treatment option to an implant-retained obturator.
Dental Impression Technique
;
Dental Prosthesis Design
;
Dental Prosthesis Retention
;
Denture Retention
;
Denture, Complete, Upper
;
Fibrous Dysplasia of Bone
;
rehabilitation
;
surgery
;
Humans
;
Male
;
Maxilla
;
surgery
;
Orthognathic Surgical Procedures
;
instrumentation
;
methods
;
rehabilitation
;
Palatal Obturators
;
Silicones
;
Treatment Outcome
;
Young Adult

Result Analysis