1.A comparative study based on the mandibular movement track and the movement parameters of the virtual articulator in simulating occlusal adjustment.
Liya MA ; Jiarui CHAO ; Fei LIU ; Jiansong MEI ; Jiefei SHEN
West China Journal of Stomatology 2023;41(3):254-259
OBJECTIVES:
This study aimed to compare the effects of virtual adjustment on occlusal interferences in mandibular posterior single crown and three-unit bridge restorations by using the mandibular movement track and the movement parameters of a virtual articulator.
METHODS:
Twenty-two participants were recruited. Digital casts of the maxillary and mandibular arches were obtained using an intraoral scanner, and the jaw registration system was used to record the data of the mandibular movement track and the movement parameters of the articulator. Four kinds of restorations with 0.3 mm occlusal interferences were designed with dental design software. In particular, single crowns were designed for teeth 44 and 46, whereas three-unit bridges were designed for teeth 44-46 and 45-47, and the corresponding natural teeth were virtually extracted. Virtual adjustment of the restorations was performed using two dynamic occlusal recordings, namely, the mandibular movement track and the movement parameters of the virtual articulator. A reverse-engineering software was used to measure the root-mean-square of the three-dimensional deviation of the occlusal surfaces between natural teeth and the adjusted restorations. The differences between the two methods of virtual-occlusion adjustment were compared and analyzed.
RESULTS:
For the same group of restorations, the three-dimensional deviation of the mandibular movement track group were lower than those of the virtual articulator group, and the differences were statistically significant (P<0.05). For the four groups of restorations adjusted by the same method, the three-dimensional deviation of the 46-tooth single crown was the largest and the smallest three-dimensional deviation was that of the 44-tooth single crown. Statistical differences existed between the 44-tooth single crown and the other groups (P<0.05).
CONCLUSIONS
For the occlusal design of posterior single crown and three-unit bridge, the mandibular movement track could be a more effective approach to virtual occlusal adjustment than the movement parameters of the virtual articulator.
Humans
;
Mouth, Edentulous
;
Occlusal Adjustment
;
Jaw Relation Record
;
Dental Articulators
;
Software
2.Accuracy of intercuspal occlusion in 3D reconstruction with the dental articulator position method.
Lin Lin LI ; Yi Jiao ZHAO ; Hu CHEN ; Yong WANG ; Yu Chun SUN
Journal of Peking University(Health Sciences) 2020;52(1):138-143
OBJECTIVE:
To evaluate the three-dimensional (3D) reconstruction accuracy of the intercuspal occlusion (ICO) of the dental casts, by the dental articulator position method, and provide a reference for clinical application.
METHODS:
The standard dental casts in ICO were mounted on average values articulator, and five pairs of milling resin cylinders were respectively attached to the base of both the casts. 100 μm articulating paper and occlusal record silicone rubber were used to detect the occlusal contact number between the posterior teeth of casts mounted on articulator in ICO. The occlusal contact numbers NA detected by the two methods were calculated simultaneously, as the reference. After the upper and lower casts were scanned separately, and the buccal data of casts in ICO were scanned with the aid of the dental articulator position, registration was carried out utilizing the registration software. Then the digital casts mounted in ICO as well as the buccal occlusal data were saved in standard tessellation language (STL) format. Geomagic Studio 2013 software was used to analyze the contact number NS between digital upper and lower casts by the "deviation analysis" function. The differences were compared between NS and NA, to evaluate the sensitivity and positive predict value (PPV) of the model scanner to reproduce the occlusal contact with the aid of dental articulator position. The distance DR between the centers of the circles at the top surface of the upper and lower corresponding cylinders was obtained by the three-coordinate measuring system Faro Edge, as the reference value. The Geomagic Studio 2013 software was used to construct the cylinders of digital casts and the distance DM between the centers of the circles at the top surface of the corresponding cylinders were measured, as the test value. The one-sample T test was used to analyze the variable differences between DM and DR.
RESULTS:
The PPV of reproducing the occlusal contact point was 0.76 and sensitivity was 0.81. The distance error of the opposite cylinder was (0.232±0.089) mm. There was no statistical difference between the feature points 5-5', while there were statistical differences between the other feature points.
CONCLUSION
By the dental articulator position method, the model scanner reproduces the occlusal contact point with high sensitivity and PPV, and that meets clinical needs. Meanwhile, the distance between the feature points is greater than the reference value, which will lead to occlusal disturbance, and require clinical grinding.
Dental Articulators
;
Dental Occlusion
;
Imaging, Three-Dimensional
;
Jaw Relation Record
;
Models, Dental
;
Software
3.Method and accuracy of determining the jaw position of repositioning splint with the aid of digital technique.
Shuo Bo FANG ; Guang Ju YANG ; Yan Feng KANG ; Yu Chun SUN ; Qiu Fei XIE
Journal of Peking University(Health Sciences) 2020;53(1):76-82
OBJECTIVE:
To establish the workflow of determining the jaw position of repositioning splint with the aid of digital technique, and to evaluate the accuracy of this workflow and compare the accuracy of raising different vertical dimensions in vitro.
METHODS:
A volunteer was recruited. The data of full-arch scans, cone beam computed tomography (CBCT) image and ultrasonic jaw motion tracking of the volunteer were acquired. The full-arch scans were merged with the CBCT image, which were then matched to the jaw motion tracking reference system. The jaw position of repositioning splint was determined when the anterior teeth opening was 3 mm and the condyle was in centric relation of the fossa in the sagittal plane. A digital repositioning splint was designed in the software based on virtual articulator and fabricated with additive manufacturing technique. After the splint was tried in, another CBCT image was taken and a qualitative analysis was conducted to compare the position of condyle between these two CBCT images. In the in vitro study, standard dental plaster casts with resin ball markers attached to the base were mounted onto a fully adjustable articulator in the intercuspal position. The dental casts were scanned by an extraoral scanner to establish digital models. The ultrasonic jaw motion tracking device was used to obtain simulated jaw movements on the articulator, which was repeated for three times. The digital models and data of jaw movements were merged in one coordination with the aid of bite forks. The jaw position of repositioning splint was determined by adjusting data of jaw movements, each of which was used to determine three vertical jaw positions 4 mm, 5 mm, and 6 mm with the horizontal jaw position of protrusion 2 mm. The virtual articulators with differently adjusted jaw movements were applied in designing repositioning splints, and the final repositioning splints and virtual jaw relationships were exported in STL format. Then the repositioning splints were fabricated with additive manufacturing technique and tried in plaster casts on the mechanical articulator, which were scanned and the jaw relationships on the mechanical articulator were exported later. The virtual jaw relationships and scanned jaw relationships were registered according to lower models and displacement of upper models was calculated. Ball markers were fit to acquire the coordinates of centers and absolute difference values of centers along three coordinating axes X, Y, and Z were calculated. One-way analysis of variance was conducted using SPSS 18.0 software to compare deviations of the three different vertical jaw relationships in two-side test and the significance level was 0.05.
RESULTS:
With the aid of multi-source data fusion and individualized jaw motion, the clinical workflow of determining jaw position of repositioning splint was preliminarily established. The designed jaw position was realized on the right and the condyle was more inferior than the designed position on the left. Both displacement of the upper models and absolute difference values of centers showed no significant differences (P>0.05) in different vertical jaw dimensions. The displacement of the upper models was (0.25±0.04) mm. The absolute difference values of centers along the three coordinating axes X, Y, and Z were respectively (0.08±0.01) mm, (0.30±0.02) mm, and (0.21±0.04) mm.
CONCLUSION
A novel method of determining the jaw position of repositioning splint with the aid of digital technique is established. It is proved to be feasible by try-in after multi-data fusion, computer-aided design and computer-aided manufacturing. As is shown in vitro, it is accurate to apply this method in adjusting jaw position. Further clinical trial will be designed to evaluate its clinical effect.
Computer-Aided Design
;
Cone-Beam Computed Tomography
;
Dental Articulators
;
Humans
;
Jaw Relation Record
;
Occlusal Splints
;
Software
;
Splints
4.Evaluation of Bonwill triangle using cone beam computerized tomography in Korean
Journal of Dental Rehabilitation and Applied Science 2018;34(2):97-103
PURPOSE: The aim of this study was to evaluate the Bonwill triangle of Korean using the cone beam computerized tomography (Cone-beam CT). MATERIALS AND METHODS: 120 Koreans (60 males and 60 females) who visited Daejeon Dental College Hospital of Wonkwang University and who underwent the Cone-beam CT were selected. The Cone-beam CT images were analysed with Invivo 5.1 (Anatomage, San Jose, USA). After reorientation of axis, the intercondylar distance was measured by clicking both middle points of condyle. And the condyle-incisor distance was measured by clicking the middle point of condyle and contact point of the mandibular central incisor's incisal edge. The collected data were analysed using the SPSS Version 23.0 (IBM Inc., Armonk, USA) and statistical significance was verified by gender using independent t-test. RESULTS: The mean intercondylar distance of Korean was 105.9 mm, and the male (108.3 mm) was statistically significantly larger than the female (103.4 mm). The mean condyle-incisor distance of Korean was 105.2 mm, and the male (108.1 mm) was statistically significantly larger than the female (102.3 mm). CONCLUSION: The mean intercondylar distance of Korean in this study was 105.9 mm that was smaller than well-known 110 mm of Caucasian and the male was statistically significantly larger than the female. Within the limitations of this study, it would be necessary to use the articulator which can adjust the intercondylar distance according to the individual for prosthodontic treatment of Korean.
Cone-Beam Computed Tomography
;
Dental Articulators
;
Female
;
Humans
;
Male
5.Implant impression using closed mouth impression technique: a case report.
So Yeun KIM ; Joo Hyeun KIM ; Kyoung Hwa JUNG ; Hye Mi JEON ; Eun Sook KANG ; Mi Jung YUN
Journal of Dental Rehabilitation and Applied Science 2017;33(3):223-229
Closed mouth impression technique by using bite tray is preferred for single tooth impression taking. However, for implant impression taking, open mouth impression technique by using single arch tray is generally used whether it is for single implant or multiple implant. Closed mouth impression technique by using bite tray can save time and materials. It also decreases the chance of error occurrence when a model is mounted on an articulator. In this case report, we tried to show a satisfying result of fabricating single implant fixed prosthodontics after bite tray impression taking by using two different copings for closed mouth impression.
Dental Articulators
;
Mouth*
;
Prosthodontics
;
Tooth
6.Correlation between sagittal condylar guidance angles obtained using radiographic and protrusive occlusal record methods.
Oh Kyun KWON ; Seung Won YANG ; Jee Hwan KIM
The Journal of Advanced Prosthodontics 2017;9(4):302-307
PURPOSE: This study compared the SCGAs measured in three types of radiographic images (panoramic, CBCT panoramic-section, and CBCT cross-section images) with values measured using the protrusive occlusal record. MATERIALS AND METHODS: SCGAs were measured in 20 patients on a semi-adjustable articulator using the protrusive interocclusal record. Panoramic and CBCT images were obtained. SCGAs were measured on CBCT images in panoramic and cross sections. In all of the radiographic images, SCGAs were measured using the Frankfort horizontal reference line and the mean curvature line. The most-superior and most-inferior points of the curvatures were identified to determine the mean curvature line. Each measurement was performed twice by two operators independently. The data were analyzed by the t-test, Pearson's correlation test, and Cronbach's α using SPSS (α=.05). RESULTS: The mean right and left SCGAs were as follows: protrusive occlusal record (30.1 and 30.2 degrees, respectively), panoramic (38.9 and 38.7 degrees), CBCT panoramic sections (35.4 and 36.8 degrees), and CBCT cross sections (35.3 and 36.1 degrees). The SCGAs differed significantly among the groups. The Pearson coefficients for the correlations with the protrusive occlusal record measurements on the left and right sides were as follows: panoramic (0.834 and 0.791, respectively), CBCT panoramic-section (0.918 and 0.837), and CBCT cross-section (0.918 and 0.845) images. CONCLUSION: Strong correlations were found between SCGAs obtained using radiographic images and the protrusive occlusal record.
Dental Articulators
;
Humans
;
Methods*
7.Application of ARCUS digma I, II systems for full mouth reconstruction: a case report.
Journal of Dental Rehabilitation and Applied Science 2016;32(4):345-350
Transferring condylar and anterior guidance on an articulator is essential to the diagnosis of a patient for full mouth reconstruction. In this clinical report, ARCUS digma I system was used to measure inherent condylar guidance of a patient requiring full mouth reconstruction in preoperate treatment, and the patients was given provisional restoration based on a functional anterior guidance. Then, ARCUS digma II system was used to mount the final casting model on an articulator, and the definitive prosthesis was placed in the patient. An esthetic and functionally proper clinical result regarding inherent condylar path of the patient was observed, and results from comparison of the two systems are given in this case.
Dental Articulators
;
Diagnosis
;
Humans
;
Mouth*
;
Prostheses and Implants
8.Does the maxillary anterior ratio in Korean adults follow the Golden Proportion?.
Ming Xu JIN ; Min Ho HONG ; Kee Joon LEE ; Kyu Bok LEE
The Journal of Advanced Prosthodontics 2016;8(2):125-130
PURPOSE: The purpose of this study was to determine the effect of changes in the horizontal plane angle on the mesiodistal width ratios of the maxillary anterior teeth during the acquisition of frontal view photographs, derive these ratios for Korean adults on the basis of the data obtained, and analyze them using the Golden Proportion as a reference. MATERIALS AND METHODS: In experiment I, 30 plaster casts were mounted on an articulator and positioned on the angle-measuring device with a center setting of 0°. The device was rotated to 10° in 1° increments in a counterclockwise direction. At each angle, photographs were obtained and analyzed. Experiment II was based on 60 patients who visited the Department of Prosthodontics at Kyungpook National University Dental Hospital from February 2012 to February 2015. The patients were divided into three groups [Male (M), Female (F), Total (M + F)]. Frontal views were obtained for all groups and analyzed. RESULTS: From 1° to 10°, the relative mesiodistal width ratios for the maxillary anterior teeth showed no significant differences from those at 0°. In all three groups, the relative width ratio of the maxillary central incisor was smaller than that specified in the Golden Proportion; the opposite was true for the canine. CONCLUSION: Our results suggest that the mesiodistal width ratios of the maxillary anterior teeth do not follow the Golden Proportion in Korean adults, and that a change in the horizontal plane angle from 1° to 10° during frontal photography does not affect these ratios.
Adult*
;
Casts, Surgical
;
Dental Articulators
;
Female
;
Gyeongsangbuk-do
;
Humans
;
Incisor
;
Photography
;
Prosthodontics
;
Tooth
9.Stability of phonetics to determine the horizontal jaw relation in healthy adults.
Xixi ZHANG ; Jianzhang LIU ; Jian-guo TAN ; Yang YANG ; Jun XU
West China Journal of Stomatology 2015;33(5):488-491
OBJECTIVEThe aim of this study was to compare the mandibular position when speaking with the intercuspal position and to check the stability of phonetics when determining the horizontal jaw relation in healthy adults.
METHODSA total of 19 healthy volunteers were recruited. Seven Chinese letters, namely, /xi/, /er/, /yi/, /ci/, /mi/, /ni/, and /ri/, were chosen in the test. O-bite was used to record the mandibular position when speaking these letters. A full-adjusted articulator was used to find the mandibular position during speech, and the mandibular position was measured using a vernier caliper. The mandibular position during speech with intercuspal position was compared in both anterior-posterior and left-right directions of the horizontal plane. Multi-factor analysis of variance was conducted for the statistical analysis of the effect of objects and letters on the mandibular position.
RESULTS1) The mandibular position was in front of the intercuspal occlusion position when speaking all seven letters, and almost no deviation was observed in the left and right directions (the mandibular position value of 82% was in the range of 0.5 mm). 2) Different objects had different mandibular positions during speech, whereas different letters did not. The distance between the centric relation position and the intercuspal position had a positive correlation with the range of the mandibular position during speech.
CONCLUSIONThe mandibular position was in front of the intercuspal position when speaking all seven words in the test. In the same object, the mandibular position was stable during speech.
Adult ; Centric Relation ; Dental Articulators ; Dental Occlusion ; Humans ; Jaw Relation Record ; Mandible ; Phonetics ; Speech
10.Mouth rehabilitation of a patient with severely worn dentition with vertical dimension increase.
Ki Young LEE ; Chi Yoon KIM ; Ji Hye JUNG ; Yu Lee KIM
The Journal of Korean Academy of Prosthodontics 2015;53(3):215-221
Treating patients with severely worn dentition often requires comprehensive prosthetic treatments. Oral rehabilitation and long-term stability could be achieved by analyzing the cause of the wear and changing vertical dimension. The temporary restoration procedure is executed and patient's adaptation is evaluated by long-term observation when treatment is accompanied with increasing vertical dimension. In this case, 54 year-old male presented with worn dentition and esthetic dissatisfaction. In oral manifestations, severely worn dentition with attrition and erosion is diagnosed. To evaluate change of vertical dimension, interocclusal rest space, facial appearance, pronunciation, clinical crown length, distance from incisor edge to labial vestibule are evaluated. Consequently, 2.5 mm increase of vertical dimension that based on articulator incisal pin is determined. After 8 weeks stabilization period with temporary prostheses, definitive prostheses are fabricated. After 6 months follow up period, satisfactory outcomes were achieved both in functional and esthetic aspects through this procedure.
Crowns
;
Dental Articulators
;
Dentition*
;
Follow-Up Studies
;
Humans
;
Incisor
;
Male
;
Mouth Rehabilitation*
;
Oral Manifestations
;
Prostheses and Implants
;
Rehabilitation
;
Tooth Wear
;
Vertical Dimension*

Result Analysis
Print
Save
E-mail