1.One-year outcomes of a novel domestic transcatheter aortic valve system in severe aortic stenosis: a multicenter cohort study
Yuehuan LI ; Jiawei ZHOU ; Lai WEI ; Yingqiang GUO ; Liang MA ; Huiming GUO ; Xiangbin PAN ; Dongjin WANG ; Fanyan LUO ; Jue WANG ; Minxin WEI ; Deguang FENG ; Yingbin XIAO ; Liming LIU ; Jian′an WANG ; Jiangang WANG ; Haibo ZHANG
Chinese Journal of Surgery 2025;63(11):1052-1058
Objective:To examine the safety and effectiveness of a novel domestic transcatheter aortic valve system in addressing severe aortic valve stenosis.Methods:This prospective, multicenter, single-arm target-value clinical trial enrolled patients with severe aortic stenosis meeting inclusion criteria from 13 Chinese centers between July 2021 and April 2022. The primary endpoint was all-cause mortality at 1-year post-procedure. Secondary endpoints included safety outcomes (30-day all-cause mortality, 1-year major adverse cardiovascular events, device success) and efficacy parameters (transvalvular pressure gradient, paravalvular leak severity, New York Heart Association(NYHA)class improvement, and quality of life). Survival analysis was performed using the Kaplan-Meier analysis.Results:The study included 134 patients, 85 males and 49 females, with an age of (73.6±5.6)years (range: 65.1 to 91.8 years). Bicuspid aortic valve morphology was present in 59.7% (80/134). Device success rate was 99.3%, with one case converted to open surgery due to coronary obstruction. All-cause mortality was 0.8% (95% CI: 0.1% to 5.3%) at both 30-day and 1-year follow-up, significantly lower than the 25% target value ( P<0.01). Permanent pacemaker implantation rates remained 2.2% (3/134) at both timepoints. Stroke incidence was 0.7% (1/134) at 30 days and 1.5% (2/134) at 1 year. Myocardial infarction rates were 0.7% (1/134) at both intervals. The postoperative transvalvular pressure gradient of the aortic valve was (6.6±3.1) mmHg(1 mmHg=0.133 kPa) (range: 4 to 8 mmHg). Among the patients, 32 cases (23.9%) had mild paravalvular leakage, 4 cases (3.0%) had moderate paravalvular leakage, and no severe paravalvular leakage was observed. NYHA class Ⅰ and Ⅱ patients increased from 18.7% preoperatively to 99.3% postoperatively. Conclusion:The novel domestic transcatheter aortic valve system demonstrates satisfactory 1-year safety and efficacy outcomes in treating severe aortic stenosis.
2.Effect of chloroquine on replication and proliferation of porcine hemagglutinating encephalomyelitis virus
Ao ZHANG ; Ruizhao QIU ; Zi LI ; Feng GAO ; Deguang SONG
Chinese Journal of Veterinary Science 2025;45(4):634-639
Porcine hemagglutinating encephalomyelitis virus(PHEV)is highly prevalent and wide-ly distributed,and its harm on pig farming is of great concern,therefore,effective strategies for prevention and control are necessary.In this study,chloroquine(CQ)was selected and its effect and mechanism on replication and proliferation of PHEV were investigated.The results showed that CQ(1-100 mmol/L)inhibits the replication and proliferation of PHEV in a dose-dependent manner and has no cytotoxicity on N2a cells.The production of inflammatory cytokines and activa-tion of NF-κB signaling pathway were both inhibited by CQ concentration at 50 mmol/L in PHEV-infected N2a cells.In conclusion,we confirmed the inhibition of CQ in replication and proliferation of PHEV.It is expected to be applied to the prevention and treatment of PHEV in clinical.
3.Cause and treatment strategy of bone cement leakage after percutaneous vertebroplasty for osteoporotic vertebral compression fractures
Xiaoguang CHEN ; Fuquan LIU ; Deguang ZHANG
Chinese Journal of Tissue Engineering Research 2025;29(16):3311-3317
BACKGROUND:With the aging of the population,the incidence of osteoporosis is increasing year by year,and osteoporotic spinal fracture,as one of the common complications,brings great pain and inconvenience to patients.As an effective treatment,percutaneous vertebroplasty has been widely used in clinical practice.However,cement leakage as a potential risk of this procedure has been the focus of researchers.OBJECTIVE:To investigate the causes and management strategies of cement leakage after percutaneous vertebroplasty for osteoporotic vertebral compression fractures.METHODS:A total of 100 osteoporotic vertebral compression fractures patients who underwent percutaneous vertebroplasty in the Department of Orthopedics of Beijing Pinggu District Hospital from March 2017 to February 2021 were selected as the study subjects.According to the 12-month follow-up results,the patients were divided into bone cement leakage group(n=27)and non-bone cement leakage group(n=73).Cox proportional risk regression analysis was used to screen the influencing factors of bone cement leakage after surgery,so as to construct and evaluate the nomogram model for predicting the risk of bone cement leakage after surgery.Visual analog scale score and Oswesry dysfunction index of 27 patients were observed before surgery,3 days and 12 months after surgery following bone cement leakage treatment.RESULTS AND CONCLUSION:(1)Among the 27 patients with bone cement leakage,24 patients had internal leakage of intervertebral disc endplate,no obvious symptoms or discomfort,and no special treatment.Pulmonary embolism occurred in 1 case,and the patient was treated with the help of respiratory department.Two patients with symptoms underwent percutaneous intervertebral foramen endoscopic bone cement removal.(2)CT value,fracture severity,bone cement viscosity,cortical fracture,and injection amount of bone cement were the independent influencing factors for postoperative bone cement leakage(P<0.05).(3)The calibration degree and differentiation degree of the nomogram model were good,and it had good clinical practicability.(4)For 27 patients with external bone cement leakage after surgery,visual analog scale score at 3 days and 12 months after surgery was significantly lower than that before surgery,and the difference was statistically significant(P<0.05).Oswesry dysfunction index score at 12 months after surgery was significantly lower than that at 3 days after surgery,and the difference was statistically significant(P<0.05).(5)The results show that the amount of bone cement injection,bone cement viscosity,cortical fracture,CT value,and fracture severity are the risk factors of bone cement leakage after percutaneous vertebroplasty.
4.Analysis of risk factors for pulmonary artery hypertension in patients with maintenance peritoneal dialysis and establishment and verification of a nomogram
Shuang Zu ; Qiqi Yan ; Le Yang ; Huixian Li ; Xiude Li ; Yunshan Fan ; Bao Zhang ; Deguang Wang
Acta Universitatis Medicinalis Anhui 2025;60(11):2159-2165
Objective:
To identify the risk factors for pulmonary arterial hypertension(PAH) in maintenance peritoneal dialysis(MPD) patients and to develop and validate a nomogram-based risk-prediction model.
Methods:
A total of 168 hospitalized MPD patients from the Department of Nephrology were enrolled.Body-fluid composition was measured by bioelectrical impedance analysis,and pulmonary-artery systolic pressure(PASP) was assessed by echocardiography.Patients were randomly allocated into a training set and a validation set at 1:1 ratio.Variables with P< 0. 05 in multivariable Logistic regression in the training set were incorporated to construct a nomogram .The validation set was used to test the model ’s predictive performance . ROC curves , calibration curves , and decision-curve analysis were applied to evaluate accuracy , consistency , and clinical usefulness of the model .
Results:
Dialysis vintage ( OR : 1 . 038 , 95% CI: 1 . 008 - 1 . 069 , P = 0. 012) , hemoglobin level ( OR : 0. 961 , 95% CI: 0. 929 - 0. 994 , P = 0. 021) , and extracellular water/intracellular water ratio (E/I) (OR : 1 . 069 , 95% CI: 1 . 024- 1 . 115 , P = 0. 002) were independent risk factors for PAH . ROC analysis yielded area under curve as 0. 867 (95% CI: 0. 782 - 0. 953) and 0. 808 (95% CI: 0. 714 - 0. 902) in the training and validation sets , respectively .Calibration plots showed that the predicted curves for both the training and validation sets closely overlapped with the ideal reference line , indicating that the nomogram risk-prediction model had good predictive performance . Decision-curve analysis demonstrated that , within threshold ranges of 0. 13 - 0. 76 ( training set ) and 0. 20 - 0. 76 (val- idation set ) , clinical net benefit was substantial when interventions were guided by the nomogram .
Conclusion
Dialysis vintage , hemoglobin level , and fluid-overload index (E/I) are independent risk factors for PAH in MPD patients . The nomogram based on these parameters reliably predicts PAH risk and may aid clinical decision-making.
5.Maintenance hemodialysis complicated with T-cell large granular lymphocytic leukemia and pure red cell aplasia: a case report
Yu WANG ; Jingjing ZHANG ; Qing ZHANG ; Deguang WANG
Chinese Journal of Nephrology 2025;41(10):764-767
T-cell large granular lymphocyte leukemia (T-LGLL) is a rare chronic lymphoproliferative disorder. This paper presents a T-LGLL patient who had been on maintenance hemodialysis for over 20 years. Three years prior, the patient developed erythropoietin hyporesponsiveness, with hemoglobin levels declining from 100 g/L to 49 g/L over eight months, accompanied by mild leukopenia and thrombocytopenia. Initial bone marrow biopsy and peripheral blood tests yielded inconclusive results. A 99mTc-labeled red blood cell spleen scintigraphy revealed evidence of hypersplenism, which prompted a splenectomy. Following surgery, leukopenia and thrombocytopenia resolved, but anemia persisted. Subsequently, lymphocyte counts increased, and reticulocyte progressively declined. Further investigations, including bone marrow biopsy, blood smear analysis, immunophenotyping, and T-cell receptor gene analysis, ultimately confirmed the diagnosis of T-LGLL with pure red cell aplasia. Treatment with cyclosporine resulted in a significant improvement in hemoglobin, reaching 117 g/L in 6 months. This case contributes to enhancing clinicians' awareness and understanding of this disease.
6.Structural and functional analysis of the NS2 protein of porcine hemagglutinating encephalomyelitis virus
Ao ZHANG ; Shaoqian MU ; Yihan TIAN ; Ruizhao QIU ; Guoce FU ; Junchao SHI ; Feng GAO ; Wen-qi HE ; Deguang SONG ; Zi LI
Chinese Journal of Veterinary Science 2025;45(9):1843-1848,1887
Porcine hemagglutinating encephalomyelitis virus(PHEV)is one of the coronaviruses susceptible to swine populations.The non-structural protein 2(NS2)encoded by its genome is fre-quently deleted during the epidemic transmission of the virus,but its biological significance re-mains unclear.In order to explore the structure and function of the NS2 protein,this study utilized platforms such as ProtParam,TMHMM,NetPhos3.1,and ExPASy to analyze its physicochemical properties,spatial structure,genetic evolution,and post-translational modification characteristics.Meanwhile,the NS2 protein was expressed in eukaryotes and transcriptome sequencing was per-formed to clarify the biological processes it participates in.The results showed that the NS2 protein consists of 233 amino acids,with a molecular weight of 26.735 kDa,and a half-life of approximately 30 hours in mammals.It includes 13 phosphorylation sites,2 N-glycosylation sites,and 1 O-glyco-sylation site,with no signal peptide and strong hydrophilicity.The a-helix accounts for the highest proportion in NS2(43.78%),followed by random coils(36.05%).The homology of the NS2 pro-tein between the epidemic strains PHEV-CC14 and PHEV-JL/2008 in Northeast China is 99.57%.The NS2 protein is widely involved in the regulation of nerve-related functions,such as axon guid-ance and synaptic development.This study preliminarily clarified the biological function of the NS2 protein,providing a new perspective for understanding the pathogenic mechanism of PHEV.
7.Structural and functional analysis of the NS2 protein of porcine hemagglutinating encephalomyelitis virus
Ao ZHANG ; Shaoqian MU ; Yihan TIAN ; Ruizhao QIU ; Guoce FU ; Junchao SHI ; Feng GAO ; Wen-qi HE ; Deguang SONG ; Zi LI
Chinese Journal of Veterinary Science 2025;45(9):1843-1848,1887
Porcine hemagglutinating encephalomyelitis virus(PHEV)is one of the coronaviruses susceptible to swine populations.The non-structural protein 2(NS2)encoded by its genome is fre-quently deleted during the epidemic transmission of the virus,but its biological significance re-mains unclear.In order to explore the structure and function of the NS2 protein,this study utilized platforms such as ProtParam,TMHMM,NetPhos3.1,and ExPASy to analyze its physicochemical properties,spatial structure,genetic evolution,and post-translational modification characteristics.Meanwhile,the NS2 protein was expressed in eukaryotes and transcriptome sequencing was per-formed to clarify the biological processes it participates in.The results showed that the NS2 protein consists of 233 amino acids,with a molecular weight of 26.735 kDa,and a half-life of approximately 30 hours in mammals.It includes 13 phosphorylation sites,2 N-glycosylation sites,and 1 O-glyco-sylation site,with no signal peptide and strong hydrophilicity.The a-helix accounts for the highest proportion in NS2(43.78%),followed by random coils(36.05%).The homology of the NS2 pro-tein between the epidemic strains PHEV-CC14 and PHEV-JL/2008 in Northeast China is 99.57%.The NS2 protein is widely involved in the regulation of nerve-related functions,such as axon guid-ance and synaptic development.This study preliminarily clarified the biological function of the NS2 protein,providing a new perspective for understanding the pathogenic mechanism of PHEV.
8.Self-made self-coagulating denture power helmet for PET/CT scanning of adult rats
Shen HAO ; Yaoyao ZHANG ; Zongjin QU ; Jiguo LIU ; Deguang WANG
Chinese Journal of Medical Imaging Technology 2025;41(5):697-700
Objective To observe the value of self-made self-coagulating denture power helmet for PET/CT scanning of adult rats.Methods Eleven adult healthy male SD rats with body weight of 290-300 g were selected.Taken 1 rat's head as a reference,a self-made helmet with a thickness of 2 mm was obtained using self-coagulating denture powder to fix the rat's head.Then the other 10 rats were randomly divided into group A and group B(each n=5).The heads of rats were fixed with helmets,and 18F-FDG PET(scanning time 20 min)and CT images were acquired.Pain models were constructed using rats in group B through injection of 5%formaldehyde solution 0.10 ml at the right foot at the 11th minute during PET collection.The imaging quality of 18F-FDG PET/CT in group A was observed,and CT gray values of the olfactory bulb covered by helmet and soft tissue area posterior occipital region without helmet coverage in group A were compared.The quality of PET images before and after pain induction in group B were analyzed to evaluate the fixation effect of helmet.Based on PET images,the changes of 18F-FDG standard uptake value ratio(SUVR)in primary somatosensory cortex hindlimb region(S1HL)in group B after pain induction were observed.Results PET and CT images in group A were clear,with no obvious foreign body artifacts.CT gray values of olfactory bulb and soft tissue in posterior occipital region in group A was 257.0±50.7 and 194.4±55.4,respectively,being not significantly different(P=0.054).PET images before and after pain induction in group B showed no obvious artifacts,and the continuity between covered area of helmet and non-covered area was good.After pain induction,S1HL on the contralateral side of pain induction in group B significantly activated.The ratio of SUVRafter pain induction/SUVRbefore pain induction in S1HL on the contralateral side of pain induction was 1.19±0.07,and SUVRafter pain induction was higher than SUVRbefore pain induction(P=0.001).Conclusion Self-made self-coagulation denture powder helmet could effectively fix head of adult rat during PET/CT scanning.
9.Effect of chloroquine on replication and proliferation of porcine hemagglutinating encephalomyelitis virus
Ao ZHANG ; Ruizhao QIU ; Zi LI ; Feng GAO ; Deguang SONG
Chinese Journal of Veterinary Science 2025;45(4):634-639
Porcine hemagglutinating encephalomyelitis virus(PHEV)is highly prevalent and wide-ly distributed,and its harm on pig farming is of great concern,therefore,effective strategies for prevention and control are necessary.In this study,chloroquine(CQ)was selected and its effect and mechanism on replication and proliferation of PHEV were investigated.The results showed that CQ(1-100 mmol/L)inhibits the replication and proliferation of PHEV in a dose-dependent manner and has no cytotoxicity on N2a cells.The production of inflammatory cytokines and activa-tion of NF-κB signaling pathway were both inhibited by CQ concentration at 50 mmol/L in PHEV-infected N2a cells.In conclusion,we confirmed the inhibition of CQ in replication and proliferation of PHEV.It is expected to be applied to the prevention and treatment of PHEV in clinical.
10.Self-made self-coagulating denture power helmet for PET/CT scanning of adult rats
Shen HAO ; Yaoyao ZHANG ; Zongjin QU ; Jiguo LIU ; Deguang WANG
Chinese Journal of Medical Imaging Technology 2025;41(5):697-700
Objective To observe the value of self-made self-coagulating denture power helmet for PET/CT scanning of adult rats.Methods Eleven adult healthy male SD rats with body weight of 290-300 g were selected.Taken 1 rat's head as a reference,a self-made helmet with a thickness of 2 mm was obtained using self-coagulating denture powder to fix the rat's head.Then the other 10 rats were randomly divided into group A and group B(each n=5).The heads of rats were fixed with helmets,and 18F-FDG PET(scanning time 20 min)and CT images were acquired.Pain models were constructed using rats in group B through injection of 5%formaldehyde solution 0.10 ml at the right foot at the 11th minute during PET collection.The imaging quality of 18F-FDG PET/CT in group A was observed,and CT gray values of the olfactory bulb covered by helmet and soft tissue area posterior occipital region without helmet coverage in group A were compared.The quality of PET images before and after pain induction in group B were analyzed to evaluate the fixation effect of helmet.Based on PET images,the changes of 18F-FDG standard uptake value ratio(SUVR)in primary somatosensory cortex hindlimb region(S1HL)in group B after pain induction were observed.Results PET and CT images in group A were clear,with no obvious foreign body artifacts.CT gray values of olfactory bulb and soft tissue in posterior occipital region in group A was 257.0±50.7 and 194.4±55.4,respectively,being not significantly different(P=0.054).PET images before and after pain induction in group B showed no obvious artifacts,and the continuity between covered area of helmet and non-covered area was good.After pain induction,S1HL on the contralateral side of pain induction in group B significantly activated.The ratio of SUVRafter pain induction/SUVRbefore pain induction in S1HL on the contralateral side of pain induction was 1.19±0.07,and SUVRafter pain induction was higher than SUVRbefore pain induction(P=0.001).Conclusion Self-made self-coagulation denture powder helmet could effectively fix head of adult rat during PET/CT scanning.


Result Analysis
Print
Save
E-mail