2.The Valvular Heart Disease-specific Age-adjusted Comorbidity Index (VHD-ACI) score in patients with moderate or severe valvular heart disease.
Mu-Rong XIE ; Bin ZHANG ; Yun-Qing YE ; Zhe LI ; Qing-Rong LIU ; Zhen-Yan ZHAO ; Jun-Xing LV ; De-Jing FENG ; Qing-Hao ZHAO ; Hai-Tong ZHANG ; Zhen-Ya DUAN ; Bin-Cheng WANG ; Shuai GUO ; Yan-Yan ZHAO ; Run-Lin GAO ; Hai-Yan XU ; Yong-Jian WU
Journal of Geriatric Cardiology 2025;22(9):759-774
BACKGROUND:
Based on the China-VHD database, this study sought to develop and validate a Valvular Heart Disease- specific Age-adjusted Comorbidity Index (VHD-ACI) for predicting mortality risk in patients with VHD.
METHODS & RESULTS:
The China-VHD study was a nationwide, multi-centre multi-centre cohort study enrolling 13,917 patients with moderate or severe VHD across 46 medical centres in China between April-June 2018. After excluding cases with missing key variables, 11,459 patients were retained for final analysis. The primary endpoint was 2-year all-cause mortality, with 941 deaths (10.0%) observed during follow-up. The VHD-ACI was derived after identifying 13 independent mortality predictors: cardiomyopathy, myocardial infarction, chronic obstructive pulmonary disease, pulmonary artery hypertension, low body weight, anaemia, hypoalbuminaemia, renal insufficiency, moderate/severe hepatic dysfunction, heart failure, cancer, NYHA functional class and age. The index exhibited good discrimination (AUC, 0.79) and calibration (Brier score, 0.062) in the total cohort, outperforming both EuroSCORE II and ACCI (P < 0.001 for comparison). Internal validation through 100 bootstrap iterations yielded a C statistic of 0.694 (95% CI: 0.665-0.723) for 2-year mortality prediction. VHD-ACI scores, as a continuous variable (VHD-ACI score: adjusted HR (95% CI): 1.263 (1.245-1.282), P < 0.001) or categorized using thresholds determined by the Yoden index (VHD-ACI ≥ 9 vs. < 9, adjusted HR (95% CI): 6.216 (5.378-7.184), P < 0.001), were independently associated with mortality. The prognostic performance remained consistent across all VHD subtypes (aortic stenosis, aortic regurgitation, mitral stenosis, mitral regurgitation, tricuspid valve disease, mixed aortic/mitral valve disease and multiple VHD), and clinical subgroups stratified by therapeutic strategy, LVEF status (preserved vs. reduced), disease severity and etiology.
CONCLUSION
The VHD-ACI is a simple 13-comorbidity algorithm for the prediction of mortality in VHD patients and providing a simple and rapid tool for risk stratification.
3.Research on three-dimensional ordered porous carbon-based materials prepared from Acanthopanax senticosus traditional Chinese medicine residues and their drug loading performance
De-sheng WANG ; Jia-xin FAN ; Ri-qing CHENG ; Shi-kui WU ; Lai-bing WANG ; Jia-hao SHI ; Ting-ting CHEN ; Qin-fang HE ; Chang-jin XU ; Hui-qing GUO
Acta Pharmaceutica Sinica 2024;59(10):2857-2863
Three-dimensional ordered porous carbon materials exhibit potential application prospects as excellent drug supports in drug delivery systems due to their high specific surface area, tunable pore structure, and excellent biocompatibility. In this study, three-dimensional ordered porous carbon materials were prepared using
4.Analysis of epidemiological and clinical characteristics of 1247 cases of infectious diseases of the central nervous system
Jia-Hua ZHAO ; Yu-Ying CEN ; Xiao-Jiao XU ; Fei YANG ; Xing-Wen ZHANG ; Zhao DONG ; Ruo-Zhuo LIU ; De-Hui HUANG ; Rong-Tai CUI ; Xiang-Qing WANG ; Cheng-Lin TIAN ; Xu-Sheng HUANG ; Sheng-Yuan YU ; Jia-Tang ZHANG
Medical Journal of Chinese People's Liberation Army 2024;49(1):43-49
Objective To summarize the epidemiological and clinical features of infectious diseases of the central nervous system(CNS)by a single-center analysis.Methods A retrospective analysis was conducted on the data of 1247 cases of CNS infectious diseases diagnosed and treated in the First Medical Center of PLA General Hospital from 2001 to 2020.Results The data for this group of CNS infectious diseases by disease type in descending order of number of cases were viruses 743(59.6%),Mycobacterium tuberculosis 249(20.0%),other bacteria 150(12.0%),fungi 68(5.5%),parasites 18(1.4%),Treponema pallidum 18(1.4%)and rickettsia 1(0.1%).The number of cases increased by 177 cases(33.1%)in the latter 10 years compared to the previous 10 years(P<0.05).No significant difference in seasonal distribution pattern of data between disease types(P>0.05).Male to female ratio is 1.87︰1,mostly under 60 years of age.Viruses are more likely to infect students,most often at university/college level and above,farmers are overrepresented among bacteria and Mycobacterium tuberculosis,and more infections of Treponema pallidum in workers.CNS infectious diseases are characterized by fever,headache and signs of meningeal irritation,with the adductor nerve being the more commonly involved cranial nerve.Matagenomic next-generation sequencing improves clinical diagnostic capabilities.The median hospital days for CNS infectious diseases are 18.00(11.00,27.00)and median hospital costs are ¥29,500(¥16,000,¥59,200).The mortality rate from CNS infectious diseases is 1.6%.Conclusions The incidence of CNS infectious diseases is increasing last ten years,with complex clinical presentation,severe symptoms and poor prognosis.Early and accurate diagnosis and standardized clinical treatment can significantly reduce the morbidity and mortality rate and ease the burden of disease.
5.Comparison on anti-inflammatory activity of Gynostemma pentaphyllum processed with different methods.
Shu-Yang XU ; Zi-Qing YANG ; Fei TENG ; Xun-Jiang WANG ; Qin HUANG ; De-Zhen JIN ; Min LI ; Shou-Jin LIU ; Zheng-Tao WANG ; Li-Li DING ; Jing-Jing ZHU
China Journal of Chinese Materia Medica 2023;48(19):5235-5243
The aim of this study is to investigate the effects of Gynostemma pentaphyllum dried with two different methods(air drying and heating) on inflammation in acute lung injury(ALI) mice in vivo and in vitro. Lipopolysaccharide(LPS) was sprayed into the airway of wild type C57BL/6J male mice to establish the model, and the drug was injected into the tail vein 24 h after modeling. Lung function, lung tissue wet/dry weight(W/D) ratio, the total protein concentration, interleukin 6(IL-6), IL-1β, and tumor necrosis factor-α(TNF-α) in the bronchoalveolar lavage fluid(BALF), and pathological changes of the lung tissue were used to evaluate the effects of different gypenosides on ALI mice. The results showed that total gypenosides(YGGPs) and the gypenosides substituted with one or two glycosyl(GPs_(1-2)) in the air-dried sample improved the lung function, significantly lowered the levels of IL-1β and TNF-α in BALF, and alleviated the lung inflammation of ALI mice. Moreover, GPs_(1-2) had a more significant effect on inhibiting NO release in RAW264.7 cells. This study showed that different drying methods affected the anti-inflammatory activity of G. pentaphyllum, and the rare saponins in the air-dried sample without heating had better anti-inflammatory activity.
Male
;
Mice
;
Animals
;
Tumor Necrosis Factor-alpha/metabolism*
;
Gynostemma
;
Mice, Inbred C57BL
;
Lung
;
Anti-Inflammatory Agents/metabolism*
;
Interleukin-6/metabolism*
;
Interleukin-1beta/metabolism*
;
Lipopolysaccharides/pharmacology*
6.Prolonging dual antiplatelet therapy improves the long-term prognosis in patients with diabetes mellitus undergoing complex percutaneous coronary intervention.
Jing-Jing XU ; Si-Da JIA ; Pei ZHU ; Ying SONG ; De-Shan YUAN ; Xue-Yan ZHAO ; Yi YAO ; Lin JIANG ; Jian-Xin LI ; Yin ZHANG ; Lei SONG ; Run-Lin GAO ; Ya-Ling HAN ; Jin-Qing YUAN
Journal of Geriatric Cardiology 2023;20(8):586-595
OBJECTIVE:
To investigate the optimal duration of dual antiplatelet therapy (DAPT) in patients with diabetes mellitus (DM) requiring complex percutaneous coronary intervention (PCI).
METHODS:
A total of 2403 patients with DM who underwent complex PCI from January to December 2013 were consecutively enrolled in this observational cohort study and divided according to DAPT duration into a standard group (11-13 months, n = 689) and two prolonged groups (13-24 months, n = 1133; > 24 months, n = 581).
RESULTS:
Baseline characteristics, angiographic findings, and complexity of PCI were comparable regardless of DAPT duration. The incidence of major adverse cardiac and cerebrovascular event was lower when DAPT was 13-24 months than when it was 11-13 months or > 24 months (4.6% vs. 8.1% vs. 6.0%, P = 0.008), as was the incidence of all-cause death (1.9% vs. 4.6% vs. 2.2%, P = 0.002) and cardiac death (1.0% vs. 3.0% vs. 1.2%, P = 0.002). After adjustment for confounders, DAPT for 13-24 months was associated with a lower risk of major adverse cardiac and cerebrovascular event [hazard ratio (HR) = 0.544, 95% CI: 0.373-0.795] and all-cause death (HR = 0.605, 95% CI: 0.387-0.944). DAPT for > 24 months was associated with a lower risk of all-cause death (HR = 0.681, 95% CI: 0.493-0.942) and cardiac death (HR = 0.620, 95% CI: 0.403-0.952). The risk of major bleeding was not increased by prolonging DAPT to 13-24 months (HR = 1.356, 95% CI: 0.766-2.401) or > 24 months (HR = 0.967, 95% CI: 0.682-1.371).
CONCLUSIONS
For patients with DM undergoing complex PCI, prolonging DAPT might improve the long-term prognosis by reducing the risk of adverse ischemic events without increasing the bleeding risk.
7.Development and validation of a score predicting mortality for older patients with mitral regurgitation.
De-Jing FENG ; Yun-Qing YE ; Zhe LI ; Bin ZHANG ; Qing-Rong LIU ; Wei-Wei WANG ; Zhen-Yan ZHAO ; Zheng ZHOU ; Qing-Hao ZHAO ; Zi-Kai YU ; Hai-Tong ZHANG ; Zhen-Ya DUAN ; Bin-Cheng WANG ; Jun-Xing LV ; Shuai GUO ; Run-Lin GAO ; Hai-Yan XU ; Yong-Jian WU
Journal of Geriatric Cardiology 2023;20(8):577-585
OBJECTIVE:
To develop and validate a user-friendly risk score for older mitral regurgitation (MR) patients, referred to as the Elder-MR score.
METHODS:
The China Senile Valvular Heart Disease (China-DVD) Cohort Study functioned as the development cohort, while the China Valvular Heart Disease (China-VHD) Study was employed for external validation. We included patients aged 60 years and above receiving medical treatment for moderate or severe MR (2274 patients in the development cohort and 1929 patients in the validation cohort). Candidate predictors were chosen using Cox's proportional hazards model and stepwise selection with Akaike's information criterion.
RESULTS:
Eight predictors were identified: age ≥ 75 years, body mass index < 20 kg/m2, NYHA class III/IV, secondary MR, anemia, estimated glomerular filtration rate < 60 mL/min per 1.73 m2, albumin < 35 g/L, and left ventricular ejection fraction < 60%. The model displayed satisfactory performance in predicting one-year mortality in both the development cohort (C-statistic = 0.73, 95% CI: 0.69-0.77, Brier score = 0.06) and the validation cohort (C-statistic = 0.73, 95% CI: 0.68-0.78, Brier score = 0.06). The Elder-MR score ranges from 0 to 15 points. At a one-year follow-up, each point increase in the Elder-MR score represents a 1.27-fold risk of death (HR = 1.27, 95% CI: 1.21-1.34, P < 0.001) in the development cohort and a 1.24-fold risk of death (HR = 1.24, 95% CI: 1.17-1.30, P < 0.001) in the validation cohort. Compared to EuroSCORE II, the Elder-MR score demonstrated superior predictive accuracy for one-year mortality in the validation cohort (C-statistic = 0.71 vs. 0.70, net reclassification improvement = 0.320, P < 0.01; integrated discrimination improvement = 0.029, P < 0.01).
CONCLUSIONS
The Elder-MR score may serve as an effective risk stratification tool to assist clinical decision-making in older MR patients.
8.Clinical Value Evaluation of DR Corneal Suture Ring Localization and CT 3D Reconstruction Localization of Orbital Foreign Body
Li-xu GUO ; Qing-yu CHEN ; Zhao-hui YUAN ; Chong-de LONG ; Shi-huai NIE
Journal of Sun Yat-sen University(Medical Sciences) 2023;44(6):1016-1021
ObjectiveTo investigate the clinical value of DR corneal suture ring localization and CT 3D reconstruction localization of orbital foreign bodies. MethodsRetrospective analysis was performed on patients (51 cases) suspected of ocular foreign bodies admitted to our hospital from January 2016 to December 2020 At the same time, DR corneal suture ring localization and CT three-dimensional reconstruction localization of orbital foreign bodies were performed, and the detection rate of foreign bodies by the two methods was calculated to analyze the location of ocular foreign bodies. ResultsThere were 38 cases of intraorbital foreign body identified by DR corneal suture ring localization method, and 46 cases of intraorbital foreign body identified by CT three-dimensional reconstruction localization method. The accuracy of CT three-dimensional reconstruction localization method was 90.20%, which was higher than that of DR corneal suture ring localization method 74.51% (P<0.05). Intraocular foreign bodies in 23 cases could be distinguished by DR corneal suture ring localization, and 25 cases by CT 3D reconstruction localization. The maximum diameter of intraocular foreign bodies that could be distinguished by CT 3D reconstruction localization was (2.65±0.14) mm. The diameter of intraspherical foreign body was (2.94±0.36) mm (P<0.05) lower than that which could be distinguished by DR corneal suture ring localization method. The results of DR corneal suture ring localization of orbital foreign body showed no difference compared with the results of CT 3D reconstruction localization (P>0.05). Forty cases of high density images inside and outside the eye could be clearly distinguished by CT 3D reconstruction. By using DR corneal suture ring localization method, 23 cases were confirmed to be intraocular high-density shadows, and 15 cases could not be confirmed to be intraocular high-density shadows (P < 0.05). ConclusionsFor the location of intraorbital foreign bodies, CT three-dimensional reconstruction can be used as a conventional method for locating ocular foreign bodies with high resolution and accuracy, and can detect fine metal particles inside the eyeball. Meanwhile, for a few small foreign bodies in the iris root, ciliary body and lateral suspension ligament, it is necessary to locate orbital foreign bodies with DR corneal suture ring.
9.Oral mucosal drug delivery system based on nano technology
Shui-yan CHEN ; Xiao-yu SU ; Xin-min WANG ; Biao LI ; Qing XU ; Peng-fei YUE ; Bao-de SHEN
Acta Pharmaceutica Sinica 2023;58(5):1245-1255
Oral mucosal drug delivery has the advantages of rapid drug absorption, no first-pass effect and good patient compliance. However, factors such as low drug dissolution, saliva carrying the drug into the gastrointestinal tract and the existence of physiological barriers in the mucosa may affect the mucosal permeation and bioavailability of the drug. Nanotechnology applied to drug oral mucosa delivery can overcome the above disadvantages and obtain efficient absorption effect. This paper describes the physiological structure of oral mucosa and the factors affecting the absorption of drugs in oral mucosa, reviews the application of nanotechnology such as liposomes, solid lipid nanoparticles, nanostructured lipid carriers, nanoemulsions, polymer nanoparticles, polymer micelles and nanohybrid suspensions in oral mucosal drug delivery and the mechanism of promoting drug absorption, summarizes the main problems of current research, and gives an outlook on the application of nano oral mucosal drug delivery system. The main problems of current research are summarized, and the prospects for the application of nano oral mucosal drug delivery systems are discussed.
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail