1.Construction and identification of hepatocyte-specific NLRP3 gene knockout mouse model
Hong-xiang GOU ; Jin-cheng HAN ; Feng-de GAN ; Yao-xing YI ; Ke-rui FAN ; Kai HU
Journal of Regional Anatomy and Operative Surgery 2025;34(11):950-954
Objective To explore the possibility and genetic identification method of constructing a hepatocyte-specific NLRP3 gene knockout mouse model by using Cre-LoxP system gene knockout technology.Methods Phase one:mice specifically expressing the albumin promoter-Cre(AlbCre)recombinase in hepatocytes were mated with NLRP3flox/flox mice,and the hepatocyte-specific NLRP3 gene knockout mice with the genotype of NLRP3flox/flox/AlbCre+/-(hepatocyte NLRP3 knockout group)and the control mice in the same litter with the genotype of NLRP3flox/flox/AlbCre-/-(control group in the same litter)were obtained after two generations of selection and mating.The second stage was the mass reproduction stage.Mating NLRP3flox/flox/AlbCre+/-target mice with NLRP3flox/flox mice could quickly obtain a large number of experimental target mice and control mice in the same litter.The DNA was extracted from the tails of mice after numbering,and the offspring genotype was identified by PCR.qPCR and Western blot were used to detect the mRNA and protein expression levels of NLRP3 gene in the liver tissue.HE staining was used to observe the morphological changes in liver tissues,and serum liver transaminases and inflammatory factors were detected.The changes in body weight,liver-to-body ratio and special circumstances during reproduction and development of mice in the two groups were observed.Results The offspring genotype of the target mice in the F2 generation was consistent with theoretical result of NLRP3flox/flox/AlbCre+/-.The mRNA and protein levels of NLRP3 in liver tissues of mice in the hepatocyte NLRP3 knockout group were significantly lower than those in the control group in the same litter(P<0.05).The mice in the hepatocyte NLRP3 knockout group was not affected in terms of growth,development and reproduction after the NLRP3 gene knockout.There were no statistically significant differences in the body weight,liver-to-body ratio,liver tissue morphology,serum liver transaminase or inflammatory factors between the hepatocyte NLRP3 knockout group and the control group in the same litter(P>0.05).Conclusion The Cre-LoxP gene knockout technology can be used to successfully construct a hepatocyte-specific NLRP3 gene knockout mouse model,providing an important technical support for the next step of studying the function of the NLRP3 gene in the liver at the animal level.
2.Processing technology of calcined Magnetitum based on concept of QbD and its XRD characteristic spectra.
De-Wen ZENG ; Jing-Wei ZHOU ; Tian-Xing HE ; Yu-Mei CHEN ; Huan-Huan XU ; Jian FENG ; Yue YANG ; Xin CHEN ; Jia-Liang ZOU ; Lin CHEN ; Hong-Ping CHEN ; Shi-Lin CHEN ; Yuan HU ; You-Ping LIU
China Journal of Chinese Materia Medica 2025;50(9):2391-2403
Guided by the concept of quality by design(QbD), this study optimizes the calcination and quenching process of calcined Magnetitum and establishes the XRD characteristic spectra of calcined Magnetitum, providing a scientific basis for the formulation of quality standards. Based on the processing methods and quality requirements of Magnetitum in the Chinese Pharmacopoeia, the critical process parameters(CPPs) identified were calcination temperature, calcination time, particle size, laying thickness, and the number of vinegar quenching cycles. The critical quality attributes(CQAs) included Fe mass fraction, Fe~(2+) dissolution, and surface color. The weight coefficients were determined by combining Analytic Hierarchy Process(AHP) and the criteria importance though intercrieria correlation(CRITIC) method, and the calcination process was optimized using orthogonal experimentation. Surface color was selected as a CQA, and based on the principle of color value, the surface color of calcined Magnetitum was objectively quantified. The vinegar quenching process was then optimized to determine the best processing conditions. X-ray diffraction(XRD) was used to establish the characteristic spectra of calcined Magnetitum, and methods such as similarity evaluation, cluster analysis, and orthogonal partial least squares-discriminant analysis(OPLS-DA) were used to evaluate the quality of the spectra. The optimized calcined Magnetitum preparation process was found to be calcination at 750 ℃ for 1 h, with a laying thickness of 4 cm, a particle size of 0.4-0.8 cm, and one vinegar quenching cycle(Magnetitum-vinegar ratio 10∶3), which was stable and feasible. The XRD characteristic spectra analysis method, featuring 9 common peaks as fingerprint information, was established. The average correlation coefficient ranged from 0.839 5-0.988 1, and the average angle cosine ranged from 0.914 4 to 0.995 6, indicating good similarity. Cluster analysis results showed that Magnetitum and calcined Magnetitum could be grouped together, with similar compositions. OPLS-DA discriminant analysis identified three key characteristic peaks, with Fe_2O_3 being the distinguishing component between the two. The final optimized processing method is stable and feasible, and the XRD characteristic spectra of calcined Magnetitum was initially established, providing a reference for subsequent quality control and the formulation of quality standards for calcined Magnetitum.
X-Ray Diffraction/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Particle Size
3.Prediction of testicular histology in azoospermia patients through deep learning-enabled two-dimensional grayscale ultrasound.
Jia-Ying HU ; Zhen-Zhe LIN ; Li DING ; Zhi-Xing ZHANG ; Wan-Ling HUANG ; Sha-Sha HUANG ; Bin LI ; Xiao-Yan XIE ; Ming-De LU ; Chun-Hua DENG ; Hao-Tian LIN ; Yong GAO ; Zhu WANG
Asian Journal of Andrology 2025;27(2):254-260
Testicular histology based on testicular biopsy is an important factor for determining appropriate testicular sperm extraction surgery and predicting sperm retrieval outcomes in patients with azoospermia. Therefore, we developed a deep learning (DL) model to establish the associations between testicular grayscale ultrasound images and testicular histology. We retrospectively included two-dimensional testicular grayscale ultrasound from patients with azoospermia (353 men with 4357 images between July 2017 and December 2021 in The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China) to develop a DL model. We obtained testicular histology during conventional testicular sperm extraction. Our DL model was trained based on ultrasound images or fusion data (ultrasound images fused with the corresponding testicular volume) to distinguish spermatozoa presence in pathology (SPP) and spermatozoa absence in pathology (SAP) and to classify maturation arrest (MA) and Sertoli cell-only syndrome (SCOS) in patients with SAP. Areas under the receiver operating characteristic curve (AUCs), accuracy, sensitivity, and specificity were used to analyze model performance. DL based on images achieved an AUC of 0.922 (95% confidence interval [CI]: 0.908-0.935), a sensitivity of 80.9%, a specificity of 84.6%, and an accuracy of 83.5% in predicting SPP (including normal spermatogenesis and hypospermatogenesis) and SAP (including MA and SCOS). In the identification of SCOS and MA, DL on fusion data yielded better diagnostic performance with an AUC of 0.979 (95% CI: 0.969-0.989), a sensitivity of 89.7%, a specificity of 97.1%, and an accuracy of 92.1%. Our study provides a noninvasive method to predict testicular histology for patients with azoospermia, which would avoid unnecessary testicular biopsy.
Humans
;
Male
;
Azoospermia/diagnostic imaging*
;
Deep Learning
;
Testis/pathology*
;
Retrospective Studies
;
Adult
;
Ultrasonography/methods*
;
Sperm Retrieval
;
Sertoli Cell-Only Syndrome/diagnostic imaging*
4.Construction and identification of hepatocyte-specific NLRP3 gene knockout mouse model
Hong-xiang GOU ; Jin-cheng HAN ; Feng-de GAN ; Yao-xing YI ; Ke-rui FAN ; Kai HU
Journal of Regional Anatomy and Operative Surgery 2025;34(11):950-954
Objective To explore the possibility and genetic identification method of constructing a hepatocyte-specific NLRP3 gene knockout mouse model by using Cre-LoxP system gene knockout technology.Methods Phase one:mice specifically expressing the albumin promoter-Cre(AlbCre)recombinase in hepatocytes were mated with NLRP3flox/flox mice,and the hepatocyte-specific NLRP3 gene knockout mice with the genotype of NLRP3flox/flox/AlbCre+/-(hepatocyte NLRP3 knockout group)and the control mice in the same litter with the genotype of NLRP3flox/flox/AlbCre-/-(control group in the same litter)were obtained after two generations of selection and mating.The second stage was the mass reproduction stage.Mating NLRP3flox/flox/AlbCre+/-target mice with NLRP3flox/flox mice could quickly obtain a large number of experimental target mice and control mice in the same litter.The DNA was extracted from the tails of mice after numbering,and the offspring genotype was identified by PCR.qPCR and Western blot were used to detect the mRNA and protein expression levels of NLRP3 gene in the liver tissue.HE staining was used to observe the morphological changes in liver tissues,and serum liver transaminases and inflammatory factors were detected.The changes in body weight,liver-to-body ratio and special circumstances during reproduction and development of mice in the two groups were observed.Results The offspring genotype of the target mice in the F2 generation was consistent with theoretical result of NLRP3flox/flox/AlbCre+/-.The mRNA and protein levels of NLRP3 in liver tissues of mice in the hepatocyte NLRP3 knockout group were significantly lower than those in the control group in the same litter(P<0.05).The mice in the hepatocyte NLRP3 knockout group was not affected in terms of growth,development and reproduction after the NLRP3 gene knockout.There were no statistically significant differences in the body weight,liver-to-body ratio,liver tissue morphology,serum liver transaminase or inflammatory factors between the hepatocyte NLRP3 knockout group and the control group in the same litter(P>0.05).Conclusion The Cre-LoxP gene knockout technology can be used to successfully construct a hepatocyte-specific NLRP3 gene knockout mouse model,providing an important technical support for the next step of studying the function of the NLRP3 gene in the liver at the animal level.
5.Comparison of the efficacy of TiRobot orthopaedic robot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures
Xing-Long ZHAO ; Jian-Jun SHEN ; Kang-Hu FENG ; Zhi-Wei CHEN ; Yuan-Long SI ; Xuan ZHANG ; Guan-De WANG ; Xiang HAI
China Journal of Orthopaedics and Traumatology 2024;37(2):129-134
Objective To compare the effectiveness of TiRobot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures.Methods A retrospective analysis was conducted on 72 patients with unstable femoral neck fractures who were treated with percutaneous cannulated screw fixation assisted with TiRobot Orthopaedic robot from December 2019 to April 2021.Among them,37 patients were treated with F screw internal fixa-tion,including 16 males and 21 females,aged47 to 64years old with an average of(53.87±5.28)years old;According to Pauwels classification,there were 1 case of type Ⅰ,19 cases of type Ⅱ,17 cases of type Ⅲ;8 cases of combined medical diseases;17 cases of falling,8 cases of traffic accident and 12 cases of falling from height;The time from injury to operation was 29 to 49 hours with average of(35.00±7.34)hours.Another 35 cases used internal fixation with an inverted triangle parallel nail,including 13 males and 22 females with an average age of 46 to 63 years old(52.36±5.05)years old;According to the Pauwels injury classifi-cation:there were 2 cases of type Ⅰ,21 cases of type Ⅱ,12 cases of type Ⅲ;6 cases of medical diseases,15 cases of falling in-jury,9 cases of traffic accident,11 cases of falling injury;The time from injury to operation was 30 to 45 hours with an average of(33.00±6.83)h.The intraoperative blood loss,operation time,intraoperative fluoroscopy times,follow-up time,fracture healing time,postoperative complications were observed and compared between the two groups.The hip joint function was e-valuated by Harris score at 6 months and 12 months after operation.Results There was no significant difference in operation time,intraoperative blood loss,intraoperative fluoroscopy times and other intraoperative data between two groups(P>0.05).Both groups were followed up regularly,and the follow-up time was 12 to 16 months.The fracture healing time and Harris score of the F screw internal fixation group were better than those of the inverted triangle parallel nail internal fixation group(P<0.05).There was 1 case of femoral neck shortening in the F screw internal fixation group,1 case of nonunion,1 case of nail withdrawal,and 1 case of lower extremity deep vein thrombosis in the inverted triangle internal fixation group.The incidence of complications in the F screw internal fixation group was lower than that in the inverted triangle parallel nail internal fixation group(P<0.05).Conclusion Percutaneous cannulated F screw technique using Tirobot navigation positioning system is a safe and effective treatment for patients with unstable femoral neck fractures.It can significantly shorten the fracture healing time,reduce the incidence of postoperative complications,significantly improve hip joint function,and improve the quality of life.
6.Correlation analysis between patient stature-based optimization of image acquisition parameters and low-dose coronary angiography
Hai QIAN ; Yu-Qin ZHANG ; Ke-Nan LOU ; De-Xing HU
Chinese Journal of Interventional Cardiology 2024;32(4):191-196
Objective To explore the correlation among image acquisition parameter optimization,coronary angiography radiation dose and image quality.Methods 60 patients scheduled for elective percutaneous coronary angiography from January 2022 to January 2024 in our hospital were selected.Basic information and body measurements were collected.Patients were divided into three groups based on BMI,and patients in each BMI group were randomly assigned to the conventional mode group(coronary mode image acquisition:Cardiac Left Coronary,15fps)and the optimized mode group(electrophysiology mode image acquisition:Cardiac EP,7.5fps).Radiation dose data were collected.Image quality was evaluated using an image quality scoring table.Independent sample t-tests,Mann-Whitney U tests,and one-way ANOVA were used for comparisons between groups.Pearson analysis was used for correlations.Results Higher BMI and larger chest circumference were associated with higher radiation doses in a positive linear correlation.Within each BMI group,all radiation dose data(Dose-Area Product,Air Kerma and Chest skin dose)were lower in the optimized mode group than in the conventional mode group(all P<0.05,reduction rate 48.95%-70.59%).The difference in image quality scores between two groups was not statistically significant(P>0.05),and all images were of the required quality.Conclusions The radiation dose of percutaneous coronary angiography is affected by the patient's body size,image acquisition parameters,exposure time and many other factors.Optimizing the image acquisition parameters can ensure the quality of the image while realizing the low dose of radiation and reducing the radiation hazards to the patient and the operator.
7.Antimicrobial resistance of Pseudomonas aeruginosa:surveillance report from Hunan Provincial Antimicrobial Resistance Surveillance System,2012-2021
Jian-Long LIU ; Chun-Rong SONG ; Min FU ; Qiong HU ; Li-Hua CHEN ; Chen-Chao FU ; Chen LI ; Yan-Ming LI ; Jun LIU ; Xing-Wang NING ; Guo-Min SHI ; Jing-Min WU ; Huai-De YANG ; Hong-Xia YUAN ; Ming ZHENG ; Xun HUANG ; An-Hua WU ; Nan REN
Chinese Journal of Infection Control 2023;22(12):1452-1459
Objective To understand the distribution and changes in antimicrobial resistance of clinically isolated Pseudomonas aeruginosa(P.aeruginosa)in the member hospitals of Hunan Provincial Antimicrobial Resistance Surveillance System from 2012 to 2021.Methods Antimicrobial susceptibility testing by disk diffusion or automa-ted instrument was performed on clinical isolates.Testing results were determined according to the standards of 2022 edition from American Clinical Laboratory Standards Institute(CLSI).Statistical analysis was performed by WHONET 5.6 software.Data were analyzed by trend test(Cochran-armitage)and Chi-square test with SPSS.Results A total of 176 441 strains of P.aeruginosa were surveilled by Hunan Provincial Antimicrobial Resistance Surveillance System from 2012 to 2021.99.4%of the strains were isolated from hospitalized patients,and about 70%of the strains were isolated from respiratory specimens.8.4%of P.aeruginosa were from children(0-17 years old),91.6%were from adults.Antimicrobial susceptibility testing results showed that P.aeruginosa was most sensitive to polymyxin B over 10 years,with a resis-tance rate of less than 6%.Resistance rates to piperacil-lin,piperacillin/tazobactam,ceftazidime,cefepime,aztreonam,imipenem,amikacin,gentamicin,tobramycin,cip-rofloxacin,levofloxacin,and polymyxin B all showed downward trends.A total of 29 920 carbapenem-resistant P.aeruginosa(CRPA)strains were detected.The average isolation rate of CRPA in this province was 18.0%over 10 years.CRPA detection rate from adult was 18.5%,higher than that from children(12.3%),and both showing downward trends.Conclusion The resistance rate of clinically isolated P.aeruginosa in Hunan Province to most commonly used antimicrobial agents is decreasing.
9.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
10.Analysis of clinical phenotype and genotype of Chinese children with disorders of sex development.
Hu LIN ; Hao YANG ; Jun Fen FU ; Jin Na YUAN ; Ke HUANG ; Wei WU ; Guan Ping DONG ; Hong Juan TIAN ; De Hua WU ; Da Xing TANG ; Ding Wen WU ; Li Ying SUN ; Ya Lei PI ; Li Jun LIU ; Li Ping SHI ; Wei GU ; Lu Gang HUANG ; Yi Hua WANG ; Lin Qi CHEN ; Hong Ying LI ; Yang YU ; Hai Yan WEI ; Xin Ran CHENG ; Xiao Ou SHAN ; Yu LIU ; Xu XU ; Shu LIU ; Xiao Ping LUO ; Yan Feng XIAO ; Yu YANG ; Gui Mei LI ; Mei FENG ; Xiu Qi MA ; Dao Xiang PAN ; Jia Yan TANG ; Rui Min CHEN ; Mireguli MAIMAITI ; De Yun LIU ; Xin Hai CUI ; Zhe SU ; Zhi Qiao DONG ; Li ZOU ; Yan Ling LIU ; Jin WU ; Kun Xia LI ; Yuan LI
Chinese Journal of Pediatrics 2022;60(5):435-441
Objective: To explore the heterogeneity and correlation of clinical phenotypes and genotypes in children with disorders of sex development (DSD). Methods: A retrospective study of 1 235 patients with clinically proposed DSD in 36 pediatric medical institutions across the country from January 2017 to May 2021. After capturing 277 DSD-related candidate genes, second-generation sequencing was performed to analyzed the heterogeneity and correlation combined with clinical phenotypes. Results: Among 1 235 children with clinically proposed DSD, 980 were males and 255 were females of social gender at the time of initial diagnosis with the age ranged from 1 day of age to 17.92 years. A total of 443 children with pathogenic variants were detected through molecular genetic studies, with a positive detection rate of 35.9%. The most common clinical phenotypes were micropenis (455 cases), hypospadias (321 cases), and cryptorchidism (172 cases) and common mutations detected were in SRD5A2 gene (80 cases), AR gene (53 cases) and CYP21A2 gene (44 cases). Among them, the SRD5A2 mutation is the most common in children with simple micropenis and simple hypospadias, while the AMH mutation is the most common in children with simple cryptorchidism. Conclusions: The SRD5A2 mutation is the most common genetic variant in Chinese children with DSD, and micropenis, cryptorchidism, and hypospadias are the most common clinical phenotypes. Molecular diagnosis can provide clues about the biological basis of DSD, and can also guide clinicians to perform specific clinical examinations. Target sequence capture probes and next-generation sequencing technology can provide effective and economical genetic diagnosis for children with DSD.
3-Oxo-5-alpha-Steroid 4-Dehydrogenase/genetics*
;
Child
;
China/epidemiology*
;
Cryptorchidism/genetics*
;
Disorders of Sex Development/genetics*
;
Female
;
Genital Diseases, Male
;
Genotype
;
Humans
;
Hypospadias/genetics*
;
Male
;
Membrane Proteins/genetics*
;
Penis/abnormalities*
;
Phenotype
;
Retrospective Studies
;
Steroid 21-Hydroxylase/genetics*

Result Analysis
Print
Save
E-mail