1.Impact of posterior cruciate ligament resection on the elasticity of the periarticular soft tissue sleeve in the knee joint.
Yun-Feng ZHANG ; De-Jin YANG ; Zhao-Lun WANG ; Yi-Xin ZHOU ; Hao TANG ; Xiang-Dong WU ; Han-Long ZHENG
China Journal of Orthopaedics and Traumatology 2025;38(10):1055-1060
OBJECTIVE:
To evaluate the effects of posterior cruciate ligament(PCL) resection on soft tissue elasticity and knee stability in total knee arthroplasty(TKA).
METHODS:
Six adult cadaveric knee specimens (involving 10 knees) were included in the study. With the assistance of the robotic system(TiRobot Recon, TINAVI, Beijing), total knee arthroplasty (TKA) was performed sequentially using cruciate retaining (CR) prostheses and posterior stabilizing (PS) prostheses. Between the two surgical procedures, the femoral and tibial osteotomy surfaces were not altered;only the posterior cruciate ligament (PCL) was resected and the intercondylar fossa was treated. After installing the femoral trial component, a soft tissue balance solver was used to apply tension ranging from 30 N to 90 N in 5 N increments at 0°, 10°, and 90° of knee flexion. Meanwhile, the medial and lateral joint gaps were measured synchronously. Based on the tension-gap coupling data, the equivalent elastic coefficients of the medial and lateral soft tissue sleeves at different knee flexion angles, as well as the range of the joint line convergence angle (JLCA) under fixed varus-valgus stress, were calculated. Additionally, the gap balance status under 80 N of tension was analyzed. Self-control comparisons of each indicator were conducted before and after PCL resection to analyze the change patterns.
RESULTS:
After PCL resection, in the fully extended position (knee flexion 0°). The medial equivalent elastic coefficient was 32.2 (25.7, 63.3) N·mm-1 for the CR prosthesis and 27.7 (22.0, 51.9) N·mm-1 for the PS prosthesis, and the statistically significant difference (P=0.013). The range of JLCA was 0.41°(0.26, 0.55)° for the CR prosthesis, which was smaller than 0.75° (0.40, 0.98)° for the PS prosthesis, and the difference was statistically significant(P=0.041). At 90° of knee flexion, the medial joint gap was 10.7(10.1, 11.7) mm for the CR prosthesis, which was smaller than 12.1(10.9, 15.1) mm for the PS prosthesis, with a statistically significant difference(P=0.011). No statistically significant differences were observed in other joint gaps.
CONCLUSION
PCL resection reduces the rigidity of the medial soft tissues in the fully extended knee and increases the medial joint gap in the flexed position, thereby affecting knee stability and balance. This finding suggests that PS and CR prostheses may require different morphological designs, and there should be differences in indications and osteotomy strategies between CR-TKA and PS-TKA. CR-TKA is more suitable for patients with preoperative medial soft tissue laxity.
Humans
;
Posterior Cruciate Ligament/physiopathology*
;
Knee Joint/physiopathology*
;
Arthroplasty, Replacement, Knee
;
Elasticity
;
Male
;
Female
;
Middle Aged
;
Aged
;
Biomechanical Phenomena
;
Adult
2.Exploring urban versus rural disparities in atrial fibrillation: prevalence and management trends among elderly Chinese in a screening study.
Wei ZHANG ; Yi CHEN ; Lei-Xiao HU ; Jia-Hui XIA ; Xiao-Fei YE ; Wen-Yuan-Yue WANG ; Xin-Yu WANG ; Quan-Yong XIANG ; Qin TAN ; Xiao-Long WANG ; Xiao-Min YANG ; De-Chao ZHAO ; Xin CHEN ; Yan LI ; Ji-Guang WANG ; FOR THE IMPRESSION INVESTIGATORS AND COORDINATORS
Journal of Geriatric Cardiology 2025;22(2):246-254
BACKGROUND:
Atrial fibrillation (AF) is a common cardiac arrhythmia in the elderly. This study aimed to evaluate urban-rural disparities in its prevalence and management in elderly Chinese.
METHODS:
Consecutive participants aged ≥ 65 years attending outpatient clinics were enrolled for AF screening using handheld single-lead electrocardiogram (ECG) from April 2017 to December 2022. Each ECG rhythm strip was reviewed from the research team. AF or uninterpretable single-lead ECGs were referred for 12-lead ECG. Primary study outcome comparison was between rural and urban areas for the prevalence of AF. The Student's t-test was used to compare mean values of clinical characteristics between rural and urban participants, while the Pearson's chi-square test was used to compare between-group proportions. Multivariate stepwise logistic regression analysis was performed to estimate the association between AF and various patient characteristics.
RESULTS:
The 29,166 study participants included 13,253 men (45.4%) and had a mean age of 72.2 years. The 7073 rural participants differed significantly (P ≤ 0.02) from the 22,093 urban participants in several major characteristics, such as older age, greater body mass index, and so on. The overall prevalence of AF was 4.6% (n = 1347). AF was more prevalent in 7073 rural participants than 22,093 urban participants (5.6% vs. 4.3%, P < 0.01), before and after adjustment for age, body mass index, blood pressure, pulse rate, cigarette smoking, alcohol consumption and prior medical history. Multivariate logistic regression analysis identified overweight/obesity (OR = 1.35, 95% CI: 1.17-1.54) in urban areas and cigarette smoking (OR = 1.62, 95% CI: 1.20-2.17) and alcohol consumption (OR = 1.42, 95% CI: 1.04-1.93) in rural areas as specific risk factors for prevalent AF. In patients with known AF in urban areas (n = 781) and rural areas (n = 338), 60.6% and 45.9%, respectively, received AF treatment (P < 0.01), and only 22.4% and 17.2%, respectively, received anticoagulation therapy (P = 0.05).
CONCLUSIONS
In China, there are urban-rural disparities in AF in the elderly, with a higher prevalence and worse management in rural areas than urban areas. Our study findings provide insight for health policymakers to consider urban-rural disparity in the prevention and treatment of AF.
3.The Impacts of Climate Change on the Environment and Human Health in China: A Call for more Ambitious Action.
Shi Lu TONG ; Yu WANG ; Yong Long LU ; Cun de XIAO ; Qi Yong LIU ; Qi ZHAO ; Cun Rui HUANG ; Jia Yu XU ; Ning KANG ; Tong ZHU ; Dahe QIN ; Ying XU ; Buda SU ; Xiao Ming SHI
Biomedical and Environmental Sciences 2025;38(2):127-143
As global greenhouse gases continue rising, the urgency of more ambitious action is clearer than ever before. China is the world's biggest emitter of greenhouse gases and one of the countries affected most by climate change. The evidence about the impacts of climate change on the environment and human health may encourage China to take more decisive action to mitigate greenhouse gas emissions and adapt to climate impacts. This article aimed to review the evidence of environmental damages and health risks posed by climate change and to provide a new science-based perspective for the delivery of sustainable development goals. Over recent decades, China has experienced a strong warming pattern with a growing frequency of extreme weather events, and the impacts of climate change on China's environment and human health have been consistently observed, with increasing O 3 air pollution, decreases in water resources and availability, land degradation, and increased risks for both communicable and non-communicable diseases. Therefore, China's climate policy should target the key factors driving climate change and scale up strategic measures to curb carbon emissions and adapt to inevitable increasing climate impacts. It provides new insights for not only China but also other countries, particularly developing and emerging economies, to ensure climate and environmental sustainability whilst pursuing economic growth.
Climate Change
;
China
;
Humans
;
Greenhouse Gases
;
Air Pollution
;
Sustainable Development
;
Environment
4.Metabolomic study of the improvement of nitazoxanide on Western-diet induced hepatic steatosis in ApoE-/- mice
Hu-tai-long ZHU ; Xiao-fan CHENG ; Xin GUO ; Le CHANG ; Yin-di ZHAO ; Shang-ze WU ; De-li DONG
Acta Pharmaceutica Sinica 2024;59(9):2529-2538
Nitazoxanide is an FDA-approved antiprotozoal drug. Our previous study found that oral administration of nitazoxanide inhibited Western diet (WD)-induced hepatic steatosis in ApoE-/- mice. However, the specific mechanism remains to be elucidated. In the present study, we performed an untargeted metabolomics approach to reveal the effect of nitazoxanide on the liver metabolic profiles in WD-fed ApoE-/- mice, and carried out the cellular experiments to elucidate the underlying mechanisms. UPLC-MS-based untargeted metabolomics analysis was used to investigate the effect of nitazoxanide on global metabolite changes in liver tissues. The differential metabolites were screened for enrichment analysis and pathway analysis. Hepatocytes were treated with tizoxanide, the metabolite of nitazoxanide, to investigate the underlying mechanism based on the findings in metabolomics study. The improvement of liver lipid metabolism disorders by nitazoxanide treatment in WD-fed ApoE-/- mice was mainly through regulating glycerophospholipid metabolism,
5.Comparison of the efficacy of TiRobot orthopaedic robot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures
Xing-Long ZHAO ; Jian-Jun SHEN ; Kang-Hu FENG ; Zhi-Wei CHEN ; Yuan-Long SI ; Xuan ZHANG ; Guan-De WANG ; Xiang HAI
China Journal of Orthopaedics and Traumatology 2024;37(2):129-134
Objective To compare the effectiveness of TiRobot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures.Methods A retrospective analysis was conducted on 72 patients with unstable femoral neck fractures who were treated with percutaneous cannulated screw fixation assisted with TiRobot Orthopaedic robot from December 2019 to April 2021.Among them,37 patients were treated with F screw internal fixa-tion,including 16 males and 21 females,aged47 to 64years old with an average of(53.87±5.28)years old;According to Pauwels classification,there were 1 case of type Ⅰ,19 cases of type Ⅱ,17 cases of type Ⅲ;8 cases of combined medical diseases;17 cases of falling,8 cases of traffic accident and 12 cases of falling from height;The time from injury to operation was 29 to 49 hours with average of(35.00±7.34)hours.Another 35 cases used internal fixation with an inverted triangle parallel nail,including 13 males and 22 females with an average age of 46 to 63 years old(52.36±5.05)years old;According to the Pauwels injury classifi-cation:there were 2 cases of type Ⅰ,21 cases of type Ⅱ,12 cases of type Ⅲ;6 cases of medical diseases,15 cases of falling in-jury,9 cases of traffic accident,11 cases of falling injury;The time from injury to operation was 30 to 45 hours with an average of(33.00±6.83)h.The intraoperative blood loss,operation time,intraoperative fluoroscopy times,follow-up time,fracture healing time,postoperative complications were observed and compared between the two groups.The hip joint function was e-valuated by Harris score at 6 months and 12 months after operation.Results There was no significant difference in operation time,intraoperative blood loss,intraoperative fluoroscopy times and other intraoperative data between two groups(P>0.05).Both groups were followed up regularly,and the follow-up time was 12 to 16 months.The fracture healing time and Harris score of the F screw internal fixation group were better than those of the inverted triangle parallel nail internal fixation group(P<0.05).There was 1 case of femoral neck shortening in the F screw internal fixation group,1 case of nonunion,1 case of nail withdrawal,and 1 case of lower extremity deep vein thrombosis in the inverted triangle internal fixation group.The incidence of complications in the F screw internal fixation group was lower than that in the inverted triangle parallel nail internal fixation group(P<0.05).Conclusion Percutaneous cannulated F screw technique using Tirobot navigation positioning system is a safe and effective treatment for patients with unstable femoral neck fractures.It can significantly shorten the fracture healing time,reduce the incidence of postoperative complications,significantly improve hip joint function,and improve the quality of life.
6.Design of automatic urine volume detection and collection device
Yan CHEN ; De-Zhao ZHAI ; Xiao-Quan ZHANG ; Fu-Long LIU ; Xiao-Tao ZHANG ; Yong-Mei ZHANG ; Wei CEHN ; Fang ZHANG ; Guo-Hui WU ; Jun DENG ; Dan LI
Chinese Medical Equipment Journal 2024;45(4):66-69
Objective To develop an automatic urine volume detection and collection device to solve the problems of routine urine test.Methods An automatic urine volume detection and collection device was developed with the components of a main control system,a detection system,a prompting system and a grasping and moving system.The main control system consisted of two STM32 microcontrollers and a reset switch;the detection system was made up of a weighing module,an infrared module and indicator lights,which had its urine volume automatic detection algorithm developed based on the Keil5 platform;the prompting system realized voice broadcasting through the voice module fixed on the back panel of the box;the grasping and moving system was composed of a rail drive motor(86CM stepper motor),a photoelectric switch and a motorized gripper.Results The device developed tested urine samples with an accuracy of 99.44%,and could collect qualified samples automatically and quickly.Conclusion The device developed detects urine volume and collects samples automatically,and enhances the accuracy and efficiency of urine examination.[Chinese Medical Equipment Journal,2024,45(4):66-69]
8.Catheter ablation versus medical therapy for atrial fibrillation with prior stroke history: a prospective propensity score-matched cohort study.
Wen-Li DAI ; Zi-Xu ZHAO ; Chao JIANG ; Liu HE ; Ke-Xin YAO ; Yu-Feng WANG ; Ming-Yang GAO ; Yi-Wei LAI ; Jing-Rui ZHANG ; Ming-Xiao LI ; Song ZUO ; Xue-Yuan GUO ; Ri-Bo TANG ; Song-Nan LI ; Chen-Xi JIANG ; Nian LIU ; De-Yong LONG ; Xin DU ; Cai-Hua SANG ; Jian-Zeng DONG ; Chang-Sheng MA
Journal of Geriatric Cardiology 2023;20(10):707-715
BACKGROUND:
Patients with atrial fibrillation (AF) and prior stroke history have a high risk of cardiovascular events despite anticoagulation therapy. It is unclear whether catheter ablation (CA) has further benefits in these patients.
METHODS:
AF patients with a previous history of stroke or systemic embolism (SE) from the prospective Chinese Atrial Fibrillation Registry study between August 2011 and December 2020 were included in the analysis. Patients were matched in a 1:1 ratio to CA or medical treatment (MT) based on propensity score. The primary outcome was a composite of all-cause death or ischemic stroke (IS)/SE.
RESULTS:
During a total of 4.1 ± 2.3 years of follow-up, the primary outcome occurred in 111 patients in the CA group (3.3 per 100 person-years) and in 229 patients in the MT group (5.7 per 100 person-years). The CA group had a lower risk of the primary outcome compared to the MT group [hazard ratio (HR) = 0.59, 95% CI: 0.47-0.74, P < 0.001]. There was a significant decreasing risk of all-cause mortality (HR = 0.43, 95% CI: 0.31-0.61, P < 0.001), IS/SE (HR = 0.73, 95% CI: 0.54-0.97, P = 0.033), cardiovascular mortality (HR = 0.32, 95% CI: 0.19-0.54, P < 0.001) and AF recurrence (HR = 0.33, 95% CI: 0.30-0.37, P < 0.001) in the CA group compared to that in the MT group. Sensitivity analysis generated consistent results when adjusting for time-dependent usage of anticoagulants.
CONCLUSIONS
In AF patients with a prior stroke history, CA was associated with a lower combined risk of all-cause death or IS/SE. Further clinical trials are warranted to confirm the benefits of CA in these patients.
9.Clinical Value Evaluation of DR Corneal Suture Ring Localization and CT 3D Reconstruction Localization of Orbital Foreign Body
Li-xu GUO ; Qing-yu CHEN ; Zhao-hui YUAN ; Chong-de LONG ; Shi-huai NIE
Journal of Sun Yat-sen University(Medical Sciences) 2023;44(6):1016-1021
ObjectiveTo investigate the clinical value of DR corneal suture ring localization and CT 3D reconstruction localization of orbital foreign bodies. MethodsRetrospective analysis was performed on patients (51 cases) suspected of ocular foreign bodies admitted to our hospital from January 2016 to December 2020 At the same time, DR corneal suture ring localization and CT three-dimensional reconstruction localization of orbital foreign bodies were performed, and the detection rate of foreign bodies by the two methods was calculated to analyze the location of ocular foreign bodies. ResultsThere were 38 cases of intraorbital foreign body identified by DR corneal suture ring localization method, and 46 cases of intraorbital foreign body identified by CT three-dimensional reconstruction localization method. The accuracy of CT three-dimensional reconstruction localization method was 90.20%, which was higher than that of DR corneal suture ring localization method 74.51% (P<0.05). Intraocular foreign bodies in 23 cases could be distinguished by DR corneal suture ring localization, and 25 cases by CT 3D reconstruction localization. The maximum diameter of intraocular foreign bodies that could be distinguished by CT 3D reconstruction localization was (2.65±0.14) mm. The diameter of intraspherical foreign body was (2.94±0.36) mm (P<0.05) lower than that which could be distinguished by DR corneal suture ring localization method. The results of DR corneal suture ring localization of orbital foreign body showed no difference compared with the results of CT 3D reconstruction localization (P>0.05). Forty cases of high density images inside and outside the eye could be clearly distinguished by CT 3D reconstruction. By using DR corneal suture ring localization method, 23 cases were confirmed to be intraocular high-density shadows, and 15 cases could not be confirmed to be intraocular high-density shadows (P < 0.05). ConclusionsFor the location of intraorbital foreign bodies, CT three-dimensional reconstruction can be used as a conventional method for locating ocular foreign bodies with high resolution and accuracy, and can detect fine metal particles inside the eyeball. Meanwhile, for a few small foreign bodies in the iris root, ciliary body and lateral suspension ligament, it is necessary to locate orbital foreign bodies with DR corneal suture ring.
10.Study on the objectivity and biological mechanism of Psoralea corylifolia Linn.'s 'Great dryness damages the liver'
Ming-liang ZHANG ; Xu ZHAO ; Wei-xia LI ; Xiao-yan WANG ; Yu-long CHEN ; De-xin KONG ; Cheng-zhao WU ; Xiao-fei CHEN ; Zhao-fang BAI ; Ming NIU ; Jia-bo WANG ; Yan-ling ZHAO ; Xiao-he XIAO ; Jin-fa TANG
Acta Pharmaceutica Sinica 2023;58(4):1014-1023
According to the theory of 'Xingben Dazao'

Result Analysis
Print
Save
E-mail