1.Design of a novel, modular, mouth retractor: A concept testing study
Miguel Sandino O. Aljibe ; Airene Maria C. Apacible ; Philip B. Fullante
Acta Medica Philippina 2025;59(Early Access 2025):1-10
BACKGROUND AND OBJECTIVES
data-mce-style="text-align: justify;">Mouth retractors are essential in ensuring efficient yet safe exposure of the oral cavity and oropharynx. However, when applied improperly or haphazardly, retractors can cause tissue injuries and compromise patient safety. In addition, there are gaps in the usability of existing designs. This study aimed to identify the issues encountered by otorhinolaryngology surgeons in the use of commercially available mouth retractors, design and fabricate an improved retractor, and explore the use of additive manufacturing (popularly known as 3D printing) for retractor prototyping.
METHODSdata-mce-style="text-align: justify;">The study used the United States Food and Drug Administration (US FDA) Design Control as its framework. End-user requirements from otorhinolaryngologists were collected through key informant interviews. Results were organized into a Design Input template which was used to guide the design and development process. Prototype designs were iteratively created using computer-aided design software and 3D printing. Once design specifications were satisfied, a beta prototype was fabricated and given to another cohort of otorhinolaryngologists. The participants assessed the usability of the beta prototype. System Usability Scale (SUS) was used to quantify participant's feedback.
RESULTSdata-mce-style="text-align: justify;">Five designs were created in the course of the study. The final prototype was fabricated using a Stereolithography (SLA) 3D printer. Several features were developed to address user requirements. The primary modification was to make the retractor modular to facilitate easier and shorter mounting and assembly. Gingival injury was addressed with the replacement of the maxillary alveolus hook with support bars. Five participants evaluated the beta prototype which received a mean SUS score of 75, well above the 50th percentile threshold.
CONCLUSIONdata-mce-style="text-align: justify;">This study demonstrates the applicability of the US FDA Design Control Process in the local setting to improve the mouth retractor design. Clinical and ergonomic issues were identified and design solutions were proposed and some have been implemented in a low-fidelity prototype. Results of the small-scale usability test suggest that the present form factor can be the basis for further iterations. Future studies can implement the proposed features to address other clinical and ergonomic needs.
Human ; 3d Printing ; Printing, Three-dimensional ; Devices, Medical ; Equipment And Supplies
2.Research progress on the manufacturing technology of hollow microneedles.
Shengshuo ZHOU ; Huajian ZHOU ; Xiaoyu DU ; Ziye YU ; Tongle XU ; Shun ZHAO ; Peiqiang SU ; Leian ZHANG ; Guangyang FU ; Xuelei LIU
Journal of Biomedical Engineering 2025;42(2):423-430
Drug administration via hollow microneedles (HMN) have the advantages of painlessness, avoidance of first-pass effect, capability of sustained infusion, and no need for professional personnel operation. In addition, HMN can also be applied in the fields of body fluid extraction and biosensors, showing broad application prospects. However, traditional manufacturing technologies cannot meet the demand for low-cost mass production of HMN, limiting its widespread application. This paper reviews the main manufacturing technologies used for HMN in recent years, which include photolithography and etching, laser etching, sputtering and electroplating, micro-molding, three-dimensional (3D) printing and drawing lithography. It further analyzes the characteristics and limitations of existing manufacturing technologies and points out that the combination of various manufacturing technologies can improve production efficiency to a certain extent. In addition, this paper looks forward to the future trends of HMN manufacturing technology and proposes possible directions for its development. In conclusion, it is expected that this review can provide new ideas and references for follow-up research.
Printing, Three-Dimensional
;
Needles
;
Humans
;
Drug Delivery Systems/methods*
;
Equipment Design
;
Microinjections/methods*
3.Three-dimensional printed scaffolds with sodium alginate/chitosan/mineralized collagen for promoting osteogenic differentiation.
Bo YANG ; Xiaojie LIAN ; Haonan FENG ; Tingwei QIN ; Song LYU ; Zehua LIU ; Tong FU
Journal of Biomedical Engineering 2025;42(5):1036-1045
The three-dimensional (3D) printed bone tissue repair guide scaffold is considered a promising method for treating bone defect repair. In this experiment, chitosan (CS), sodium alginate (SA), and mineralized collagen (MC) were combined and 3D printed to form scaffolds. The experimental results showed that the printability of the scaffold was improved with the increase of chitosan concentration. Infrared spectroscopy analysis confirmed that the scaffold formed a cross-linked network through electrostatic interaction between chitosan and sodium alginate under acidic conditions, and X-ray diffraction results showed the presence of characteristic peaks of hydroxyapatite, indicating the incorporation of mineralized collagen into the scaffold system. In the in vitro collagen release experiments, a weakly alkaline environment was found to accelerate the release rate of collagen, and the release amount increased significantly with a lower concentration of chitosan. Cell experiments showed that scaffolds loaded with mineralized collagen could significantly promote cell proliferation activity and alkaline phosphatase expression. The subcutaneous implantation experiment further verified the biocompatibility of the material, and the implantation of printed scaffolds did not cause significant inflammatory reactions. Histological analysis showed no abnormal pathological changes in the surrounding tissues. Therefore, incorporating mineralized collagen into sodium alginate/chitosan scaffolds is believed to be a new tissue engineering and regeneration strategy for achieving enhanced osteogenic differentiation through the slow release of collagen.
Chitosan/chemistry*
;
Alginates/chemistry*
;
Tissue Scaffolds/chemistry*
;
Printing, Three-Dimensional
;
Osteogenesis
;
Collagen/chemistry*
;
Cell Differentiation
;
Animals
;
Tissue Engineering/methods*
;
Cell Proliferation
;
Biocompatible Materials
;
Glucuronic Acid/chemistry*
;
Hexuronic Acids/chemistry*
4.Guidelines for computer-aided design/computer-aided manufacturing custom fiber post-and-core.
Chinese Journal of Stomatology 2025;60(1):3-7
The post-and-core is a widely accepted method to restore endodontically treated teeth with compromised tooth structure. Currently, cast metal post-and-core systems and prefabricated fiber posts combined with composite resin cores are the most frequently options in dental clinical practice, but both also come with advantages and limitations. The development of computer-aided design/computer-aided manufacturing (CAD/CAM) custom fiber post-and-core represents one of the significant trends in the advancement of dentistry. Society of Digital Dental Industry, National Association of Health Industry and Enterprise Management organized experts to formulate Guidelines for CAD/CAM custom fiber post-and-core, standardizing the clinical operation procedures of this technology, enhancing the success rate of CAD/CAM custom fiber post-and-core, and promoting its application and development.
Computer-Aided Design
;
Humans
;
Post and Core Technique
;
Composite Resins
;
Dental Prosthesis Design
5.Application of personalized three-dimensional printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
Shuailei LI ; Hao CHAI ; Yongqiang SUN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):13-19
OBJECTIVE:
To analyze the short-term effectiveness and safety of personalized three-dimensional (3D) printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
METHODS:
A retrospective analysis was conducted on 8 patients with severe Paprosky type Ⅲ acetabular bone defects and met the selection criteria between January 2023 and June 2024. There were 3 males and 5 females, with an average age of 64.6 years ranged from 56 to 73 years. All primary replacement prostheses were non-cemented, including 1 ceramic-ceramic interface, 1 ceramic-polyethylene interface, and 6 metal-polyethylene interfaces. The time from the primary replacement to the revision was 4 days to 18 years. The reasons for revision were aseptic loosening in 5 cases, revision after exclusion in 2 cases, and repeated dislocation in 1 case. The preoperative Harris score was 39.5±3.7 and the visual analogue scale (VAS) score was 7.1±0.8. The operation time, intraoperative blood loss, hospital stay, and complications were recorded. The hip function was evaluated by Harris score, and the degree of pain was evaluated by VAS score. The acetabular cup abduction angle, anteversion angle, rotational center height, greater trochanter height, and femoral offset were measured on X-ray film.
RESULTS:
The operation time was 95-223 minutes, with an average of 151.13 minutes. The intraoperative blood loss was 600-3 500 mL, with an average of 1 250.00 mL. The hospital stay was 13-20 days, with an average of 16.88 days. All 8 patients were followed up 2-12 months, with an average of 6.4 months. One patient had poor wound healing after operation, which healed well after active symptomatic treatment. One patient had lower limb intermuscular vein thrombosis, but no thrombosis was found at last follow-up. No serious complications such as aseptic loosening, infection, dislocation, and periprosthetic fracture occurred during the follow-up. At last follow-up, the Harris score was 72.0±6.2 and the VAS score was 1.8±0.7, which were significantly different from those before operation ( t=-12.011, P<0.001; t=16.595, P<0.001). On the second day after operation, the acetabular cup abduction angle ranged from 40° to 49°, with an average of 44.18°, and the acetabular cup anteversion angle ranged from 19° to 26°, with an average of 21.36°, which were within the "Lewinneck safety zone". There was no significant difference in the rotational center height, greater trochanter height, and femoral offset between the healthy side and the affected side ( P>0.05).
CONCLUSION
The use of personalized 3D printed customized prostheses for the reconstruction of severe Paprosky type Ⅲ acetabular bone defects can alleviate pain and enhances hip joint function, and have good postoperative prosthesis position, without serious complications and have good safety.
Humans
;
Printing, Three-Dimensional
;
Male
;
Female
;
Middle Aged
;
Acetabulum/surgery*
;
Aged
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Reoperation
;
Treatment Outcome
6.Research progress of bioactive scaffolds in repair and regeneration of osteoporotic bone defects.
Yuangang WU ; Kaibo SUN ; Yi ZENG ; Bin SHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):100-105
OBJECTIVE:
To summarize the research progress of bioactive scaffolds in the repair and regeneration of osteoporotic bone defects.
METHODS:
Recent literature on bioactive scaffolds for the repair of osteoporotic bone defects was reviewed to summarize various types of bioactive scaffolds and their associated repair methods.
RESULTS:
The application of bioactive scaffolds provides a new idea for the repair and regeneration of osteoporotic bone defects. For example, calcium phosphate ceramics scaffolds, hydrogel scaffolds, three-dimensional (3D)-printed biological scaffolds, metal scaffolds, as well as polymer material scaffolds and bone organoids, have all demonstrated good bone repair-promoting effects. However, in the pathological bone microenvironment of osteoporosis, the function of single-material scaffolds to promote bone regeneration is insufficient. Therefore, the design of bioactive scaffolds must consider multiple factors, including material biocompatibility, mechanical properties, bioactivity, bone conductivity, and osteogenic induction. Furthermore, physical and chemical surface modifications, along with advanced biotechnological approaches, can help to improve the osteogenic microenvironment and promote the differentiation of bone cells.
CONCLUSION
With advancements in technology, the synergistic application of 3D bioprinting, bone organoids technologies, and advanced biotechnologies holds promise for providing more efficient bioactive scaffolds for the repair and regeneration of osteoporotic bone defects.
Humans
;
Tissue Scaffolds/chemistry*
;
Bone Regeneration
;
Osteoporosis/therapy*
;
Tissue Engineering/methods*
;
Biocompatible Materials/chemistry*
;
Printing, Three-Dimensional
;
Calcium Phosphates/chemistry*
;
Osteogenesis
;
Ceramics
;
Cell Differentiation
;
Hydrogels
;
Bioprinting
;
Bone and Bones
7.Effectiveness of digital three-dimensional printing osteotomy guide plate assisted total knee arthroplasty in treatment of knee osteoarthritis patients with femoral internal implant.
Chao LI ; Binbin ZHANG ; Xiangping LIU ; Haiya LI ; Jingtang ZHANG ; Min WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):151-157
OBJECTIVE:
To investigate the effectiveness of digital three-dimensional (3D) printing osteotomy guide plate assisted total knee arthroplasty (TKA) in treatment of knee osteoarthritis (KOA) patients with femoral internal implants.
METHODS:
The clinical data of 55 KOA patients who met the selection criteria between July 2021 and October 2023 were retrospectively analyzed. Among them, 26 cases combined with femoral implants were treated with digital 3D printing osteotomy guide plate assisted TKA (guide plate group), and 29 cases were treated with conventional TKA (control group). There was no significant difference in gender, age, body mass index, side, Kellgren-Lawrence classification, preoperative visual analogue scale (VAS) score, Hospital for Special Surgery (HSS) knee score, knee range of motion, and other baseline data between the two groups ( P>0.05). The operation time, intraoperative blood loss, incision length, postoperative first ambulation time, surgical complications; VAS score, knee HSS score, knee range of motion before operation, at 1 week and 3 months after operation, and at last follow-up; distal femoral lateral angle, proximal tibial medial angle, hip-knee-ankle angle and other imaging indicators at last follow-up were recorded and compared between the two groups.
RESULTS:
The operation time, incision length, intraoperative blood loss, and postoperative first ambulation time in the guide plate group were significantly lower than those in the control group ( P<0.05). In the control group, there were 1 case of incision rupture and bleeding and 1 case of lower limb intermuscular venous thrombosis, which was cured after symptomatic treatment. There was no complication such as neurovascular injury, incision infection, or knee prosthesis loosening in both groups. Patients in both groups were followed up 12-26 months, with an average of 16.25 months. The VAS score, HSS score, and knee range of motion improved at each time point after operation in both groups, and further improved with time after operation, the differences were significant ( P<0.05). The above indicators in the guide plate group were significantly better than those in the control group at 1 week and 3 months after operation ( P<0.05), and there was no significant difference between the two groups at last follow-up ( P>0.05). At last follow-up, the distal femoral lateral angle, the proximal tibial medial angle, and the hip-knee-ankle angle in the guide plate group were significantly better than those in the control group ( P<0.05).
CONCLUSION
The application of digital 3D printing osteotomy guide plate assisted TKA in the treatment of KOA patients with femoral implants can simplify the surgical procedures, overcome limitations of conventional osteotomy guides, reduce surgical trauma, achieve individualized and precise osteotomy, and effectively restore lower limb alignment and knee joint function.
Humans
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Osteoarthritis, Knee/surgery*
;
Osteotomy/instrumentation*
;
Male
;
Retrospective Studies
;
Female
;
Printing, Three-Dimensional
;
Femur/surgery*
;
Middle Aged
;
Bone Plates
;
Range of Motion, Articular
;
Aged
;
Treatment Outcome
;
Surgery, Computer-Assisted/methods*
;
Knee Prosthesis
;
Knee Joint/surgery*
;
Operative Time
8.Effectiveness of guide plate with mortise-tenon joint structure combined with off-axis fixation in treatment of Pauwels type Ⅲ femoral neck fractures.
Xuanye ZHU ; Lijuan CUI ; Leilei ZHANG ; Yudong JIA ; Yingjie ZHU ; Youwen LIU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):284-289
OBJECTIVE:
To investigate the effectiveness of using 3 hollow compression screws combined with 1 screw off-axis fixation under the guidance of three-dimensional (3D) printed guide plate with mortise-tenon joint structure (mortise-tenon joint plate) for the treatment of Pauwels type Ⅲ femoral neck fractures.
METHODS:
A clinical data of 78 patients with Pauwels type Ⅲ femoral neck fractures, who were admitted between August 2022 and August 2023 and met the selection criteria, was retrospectively analyzed. The operations were assisted with mortise-tenon joint plates in 26 cases (mortise-tenon joint plate group) and traditional guide plates in 28 cases (traditional plate group), and without guide plates in 24 cases (control group). There was no significant difference in the baseline data of gender, age, body mass index, cause of injury, and fracture side between groups ( P>0.05). The operation time, intraoperative blood loss, frequency of intraoperative fluoroscopy, incision length, incidence of postoperative deep vein thrombosis of lower extremity, pain visual analogue scale (VAS) score at 1 week after operation, and Harris score of hip joint at 3 months after operation were recorded and compared. X-ray re-examination was taken to check the quality of fracture reduction, fracture healing, and the shortening length of the femoral neck at 3 months after operation, and the incidences of internal fixation failure and osteonecrosis of the femoral head during operation.
RESULTS:
Compared with the control group, the operation time, intraoperative blood loss, and frequency of intraoperative fluoroscopy reduced in the two plate groups, and the quality of fracture reduction was better, but the incision was longer, and the differences were significant ( P<0.05). The operation time and intraoperative blood loss were significantly higher in the traditional plate group than in the mortise-tenon joint plate group ( P<0.05), the incision was significantly longer ( P<0.05); and the difference in fracture reduction quality and the frequency of intraoperative fluoroscopy was not significant between two plate groups ( P>0.05). There was 1 case of deep vein thrombosis of lower extremity in the traditional plate group and 1 case in the control group, while there was no thrombosis in the mortise-tenon joint plate group. There was no significant difference in the incidence between groups ( P>0.05). All patients were followed up 12-15 months (mean, 13 months). There was no significant difference in VAS score at 1 week and Harris score at 3 months between groups ( P>0.05). Compared with the control group, the fracture healing time and the length of femoral neck shortening at 3 months after operation were significantly shorter in the two plate groups ( P<0.05). There was no significant difference between the two plate groups ( P>0.05). There was no significant difference in the incidences of non-union fractures, osteonecrosis of the femoral head, or internal fixation failure between groups ( P>0.05).
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the use of 3D printed guide plate assisted reduction and fixation can shorten the fracture healing time, reduce the incidence of postoperative complications, and be more conducive to the early functional exercise of the affected limb. Compared with the traditional guide plate, the mortise-tenon joint plate can reduce the intraoperative bleeding and shorten the operation time.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Plates
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Bone Screws
;
Adult
;
Aged
;
Treatment Outcome
;
Printing, Three-Dimensional
;
Operative Time
9.Effectiveness of three-dimensional-printed microporous titanium prostheses combined with flap implantation in treatment of large segmental infectious bone defects in limbs.
Yongqing XU ; Xinyu FAN ; Teng WANG ; Shaoquan PU ; Xingbo CAI ; Xiangwen SHI ; Wei LIN ; Xi YANG ; Jian LI ; Min LIU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):521-528
OBJECTIVE:
To analyze the effectiveness of single three-dimensional (3D)-printed microporous titanium prostheses and flap combined prostheses implantation in the treatment of large segmental infectious bone defects in limbs.
METHODS:
A retrospective analysis was conducted on the clinical data of 76 patients with large segmental infectious bone defects in limbs who were treated between January 2019 and February 2024 and met the selection criteria. Among them, 51 were male and 25 were female, with an age of (47.7±9.4) years. Of the 76 patients, 51 had no soft tissue defects (single prostheses group), while 25 had associated soft tissue defects (flap combined group). The single prostheses group included 28 cases of tibial bone defects, 11 cases of femoral defects, 5 cases of humeral defects, 4 cases of radial bone defects, and 3 cases of metacarpal, or carpal bone defects, with bone defect length ranging from 3.5 to 28.0 cm. The flap combined group included 3 cases of extensive dorsum of foot soft tissue defects combined with large segmental metatarsal bone defects, 19 cases of lower leg soft tissue defects combined with large segmental tibial bone defects, and 3 cases of hand and forearm soft tissue defects combined with metacarpal, carpal, or radial bone defects, with bone defect length ranging from 3.8 to 32.0 cm and soft tissue defect areas ranging from 8 cm×5 cm to 33 cm×10 cm. In the first stage, vancomycin-loaded bone cement was used to control infection, and flap repair was performed in the flap combined group. In the second stage, 3D-printed microporous titanium prostheses were implanted. Postoperative assessments were performed to evaluate infection control and bone integration, and pain release was evaluated using the visual analogue scale (VAS) score.
RESULTS:
All patients were followed up postoperatively, with an average follow-up time of (35.2±13.4) months. In the 61 lower limb injury patients, the time of standing, walk with crutches, and fully bear weight were (2.2±0.6), (3.9±1.1), and (5.4±1.1) months, respectively. The VAS score at 1 year postoperatively was significantly lower than preoperative one ( t=-10.678, P<0.001). At 1 year postoperatively, 69 patients (90.8%) showed no complication such as infection, fracture, prosthesis displacement, or breakage, and X-ray films indicated good integration at the prosthesis-bone interface. According to the Paley scoring system for the healing of infectious bone defects, the results were excellent in 37 cases, good in 29 cases, fair in 3 cases, and poor in 7 cases. In the single prostheses group, during the follow-up, there was 1 case each of femoral prostheses fracture, femoral infection, and tibial infection, with a treatment success rate of 94.1% (48/51). In lower limb injury patients, the time of fully bear weight was (5.0±1.0) months. In the flap combined group, during the follow-up, 1 case of tibial fixation prostheses screw fracture occurred, along with 2 cases of recurrent foot infection in diabetic patients and 1 case of tibial infection. The treatment success rate was 84.0% (21/25). The time of fully bear weight in lower limb injury patients was (5.8±1.2) months. The overall infection eradication rate for all patients was 93.4% (71/76).
CONCLUSION
The use of 3D-printed microporous titanium prostheses, either alone or in combination with flaps, for the treatment of large segmental infectious bone defects in the limbs results in good effectiveness with a low incidence of complications. It is a feasible strategy for the reconstruction of infectious bone defects.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Titanium
;
Retrospective Studies
;
Surgical Flaps
;
Adult
;
Prosthesis Implantation/methods*
;
Plastic Surgery Procedures/methods*
;
Treatment Outcome
;
Prostheses and Implants
;
Bone Diseases, Infectious/surgery*
;
Extremities/surgery*
;
Prosthesis Design
10.Research progress in three-dimensional-printed bone scaffolds combined with vascularized tissue flaps for segmental bone defect reconstruction.
Qida DUAN ; Hongyun SHAO ; Ning LUO ; Fuyang WANG ; Liangliang CHENG ; Jiawei YING ; Dewei ZHAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):639-646
OBJECTIVE:
To review and summarize the research progress on repairing segmental bone defects using three-dimensional (3D)-printed bone scaffolds combined with vascularized tissue flaps in recent years.
METHODS:
Relevant literature was reviewed to summarize the application of 3D printing technology in artificial bone scaffolds made from different biomaterials, as well as methods for repairing segmental bone defects by combining these scaffolds with various vascularized tissue flaps.
RESULTS:
The combination of 3D-printed artificial bone scaffolds with different vascularized tissue flaps has provided new strategies for repairing segmental bone defects. 3D-printed artificial bone scaffolds include 3D-printed polymer scaffolds, bio-ceramic scaffolds, and metal scaffolds. When these scaffolds of different materials are combined with vascularized tissue flaps ( e.g., omental flaps, fascial flaps, periosteal flaps, muscular flaps, and bone flaps), they provide blood supply to the inorganic artificial bone scaffolds. After implantation into the defect site, the scaffolds not only achieve structural filling and mechanical support for the bone defect area, but also promote osteogenesis and vascular regeneration. Additionally, the mechanical properties, porous structure, and biocompatibility of the 3D-printed scaffold materials are key factors influencing their osteogenic efficiency. Furthermore, loading the scaffolds with active components such as osteogenic cells and growth factors can synergistically enhance bone defect healing and vascularization processes.
CONCLUSION
The repair of segmental bone defects using 3D-printed artificial bone scaffolds combined with vascularized tissue flap transplantation integrates material science technologies with surgical therapeutic approaches, which will significantly improve the clinical treatment outcomes of segmental bone defect repair.
Printing, Three-Dimensional
;
Tissue Scaffolds
;
Humans
;
Surgical Flaps/blood supply*
;
Tissue Engineering/methods*
;
Plastic Surgery Procedures/methods*
;
Bone and Bones/surgery*
;
Biocompatible Materials
;
Bone Regeneration
;
Bone Transplantation/methods*
;
Bone Substitutes
;
Osteogenesis


Result Analysis
Print
Save
E-mail