1.Biocompatibility of 3D printed biodegradable WE43 magnesium alloy scaffolds and treatment of bone defects.
Journal of Peking University(Health Sciences) 2025;57(2):309-316
OBJECTIVE:
To investigate the biocompatibility of porous WE43 magnesium alloy scaffolds manufactured by 3D printing technology and to observe its effect in treating femoral defects in New Zealand white rabbits.
METHODS:
In vitro cytotoxicity test was performed using bone marrow mesenchymal stem cells from Sprague Dawley (S-D) rats. According to the different culture media, the cells were divided into 100% extract group, 50% extract group, 10% extract group and control group. After culturing for 1, 3 and 7 days, the cell activity of each group was determined by cell counting kit-8 (CCK-8). In the in vivo experiment, 3.0-3.5 kg New Zealand white rabbits were randomly divided into three groups: Experimental group, bone cement group and blank group, with 9 rabbits in each group. Each rabbit underwent surgery on the left lateral femoral condyle, and a bone defect with a diameter of 5 mm and a depth of 6 mm was created using a bone drill. The experimental group was implanted with WE43 magnesium alloy scaffolds, the bone cement group was implanted with calcium sulfate bone cement, and the blank group was not implanted. Then 4, 8 and 12 weeks after surgery, 3 rabbits in each group were euthanized by carbon dioxide anesthesia, and the femur and important internal organs were sampled. Micro-computed tomography (Micro-CT) scanning was performed on the left lateral femoral condyle. Sections of important internal organs were prepared and stained with hematoxylin-eosin (HE). Hard tissue sections were made from the left lateral femoral condyle and stained with methylene blue acid fuchsin and observed under a microscope.
RESULTS:
In the cytotoxicity test, the cell survival rate in the 100% extract group was higher than that in the control group (140.56% vs. 100.00%, P < 0.05) on 1 day of culture; there was no statistically significant difference (P>0.05) in cell survival rate among the groups on 3 days of culture; the cell survival rate in the 100% extract group was lower than that in the control group (68.64% vs. 100.00%, P < 0.05) on 7 days of culture. Micro-CT scanning in the in vivo experiment found that most of the scaffolds in the experimental group had been degraded in 4 weeks, with very few high-density scaffolds remaining. In 12 weeks, there was no obvious stent outline. In 4 weeks, a certain amount of gas was generated around the WE43 magnesium alloy scaffold, and the gas was significantly reduced from 8 to 12 weeks. Hard tissue sections showed that a certain amount of extracellular matrix and osteoid were generated around the scaffolds in the experimental group in 4 weeks. In the bone cement group, most of the calcium sulfate bone cement had been degraded. In 8 weeks, the osteoid around the scaffold and its degradation products in the experimental group increased significantly. In 12 weeks, new bone was in contact with the scaffold around the scaffold in the experimental group. There was less new bone in the bone cement group and the blank group.
CONCLUSION
The porous WE43 magnesium alloy scaffold fabricated by 3D printing process has good biocompatibility and good osteogenic properties, and has the potential to become a new material for repairing bone defects.
Animals
;
Rabbits
;
Printing, Three-Dimensional
;
Alloys/chemistry*
;
Tissue Scaffolds/chemistry*
;
Magnesium/chemistry*
;
Rats, Sprague-Dawley
;
Biocompatible Materials
;
Mesenchymal Stem Cells/cytology*
;
Femur/surgery*
;
Rats
;
Absorbable Implants
;
Male
;
Bone Regeneration
;
Tissue Engineering/methods*
;
Cells, Cultured
2.In vitro study of using single cone obturation technique in artificial canals with an isthmus.
Journal of Peking University(Health Sciences) 2025;57(2):369-375
OBJECTIVE:
To evaluate the filling quality of single cone obturation in root canal model with irregular structure (Hus&Kim Ⅴ, Yin Ⅱ-type isthmus) which established by 3D printing technology using slices and radiographic methods, in order to provide reference for clinical practice.
METHODS:
(1) Extracted fresh premolars with Hus&Kim Ⅴ and Yin-type Ⅱ isthmus were collected and scanned by cone-beam computed tomography (CBCT), then standard root canal models were designed and printed. Rhodamine B staining and bias fitting were used to verify the availability of the models. (2) 30 root canal models were randomly divided into 3 groups according to different filling methods (n=10).
CONTROL GROUP:
vertical compaction obturation; Experimental group 1: single cone obturation with 0.06-taper cone (30#); Experimental group 2: single cone obturation with 0.04-taper cone (35#), GuttaFlow 2 as canal sealers. Slices were taken at 2, 4, 6, and 8 mm from the root apex in the direction perpendicular to the long axis of the root and observed under a stereomicroscope to calculate the percentage of filling area (PAV), percentage of gutta-percha-filled area (PGFA), percentage of sealer filled area (PSFA). (3) On the basis of the above results, two groups (n=4) were selected to further analyze the filling quality by micro-computed tomography (Micro-CT), the filling volume of main root canal and the isthmus were obtained, and the percentage of filling volume (PFV) was calculated. Two-way ANOVA was used to evaluate the differences between the groups, and Tukey' s multiple comparison was used to compare the data between the groups and within the groups.
RESULTS:
(1) Rhodamine B staining solution could overflow the apical foramen, and the main root canal system and the isthmus area were stained, showed no remnants of support material. The 3D standard deviation of the printed model data was 0.03 mm, and the average fitting distance was 0.02 mm. (2) The PFA of the two experimental groups were both significantly lower than that of the control group (F=45.04, P < 0.01). There was no statistical difference of the PFA at apical 2 and 4 mm between the two experimental groups (P>0.01), but at the middle and coronal portions of the root canal (6, 8 mm), the PFA of the experimental group 1 was higher than that of the experimental group 2 (P < 0.01). PFA in the apical 2, 4 mm of the two experimental groups were both lower than that in the middle and coronal portions 6, 8 mm of the canal (P < 0.01). There was no difference in the PGFA and PSFA between the two experimental groups at the apical 2, 4 mm (F=2.383, P>0.01). (3) The results of Micro-CT showed that the PFV of the experimental group 1 was statistically different with the control group (F=47.33, P < 0.01). The PFV of the experimental group 1 was 54.33%±4.35% in the isthmus and 78.31%±4.21% in the main root canal, which were both lower than the PFV of the control group of 76.48%±4.89% (isthmus) and 86.90%±3.29% (main root canal, P < 0.01). The PFV of the main root canal in the experimental group 1 was higher than that in the isthmus (P < 0.01), while there was no difference between the isthmus and the main root canal in the control group (P>0.01).
CONCLUSION
In the irregular root canal structure with isthmus, using large-taper gutta-percha can improve the filling quality of the middle and upper part of the canal, but the percentage of filling volume in the isthmus is lower than that of the main canal, and more technical improvements are needed.
Humans
;
Root Canal Obturation/methods*
;
Cone-Beam Computed Tomography
;
Root Canal Filling Materials
;
Dental Pulp Cavity/diagnostic imaging*
;
Printing, Three-Dimensional
;
In Vitro Techniques
;
Gutta-Percha
;
Bicuspid
3.Advances in 3D Printing Technology for Bolus in Radiation Therapy.
Yu CHENG ; Haiyan PENG ; Fu JIN ; Xu MA
Chinese Journal of Medical Instrumentation 2025;49(2):154-160
3D printing technology, with a layer-by-layer construction method, enables the fabrication of intricately shaped and customizable bolus. In contrast to traditional preparation methods, 3D printing technology addresses challenges such as poor bolus fit and cumbersome production processes, offering a novel approach to efficient and personalized bolus fabrication. This article discusses the research progress of 3D printing technology in radiotherapy bolus from aspects such as the preparation process, clinical application, and research advancements, combined with the actual printing experience of Department of Radiation Oncology in Chongqing University Cancer Hospital.
Printing, Three-Dimensional
;
Humans
;
Radiotherapy/methods*
4.Progress of 3D Printing Technology in Resection and Reconstruction of Oral and Maxillofacial Tumors.
Chinese Journal of Medical Instrumentation 2025;49(5):514-519
Oral and maxillofacial tumors, due to their complex anatomical structures and vital physiological functions, pose significant risks, not only affecting patients' appearance and function but also potentially endangering their lives. Traditional tumor resection and reconstruction surgeries face challenges such as inadequate precision, long surgical durations, and unsatisfactory postoperative outcomes. In the treatment of oral and maxillofacial tumors, 3D printing technology can be used for preoperative planning, surgical guide plate production, and the design and manufacture of personalized prosthetics, providing new solutions for functional reconstruction after tumor resection. This article reviews the progress of 3D printing technology in the medical field and explores its potential value in the resection and reconstruction of oral and maxillofacial tumors, aiming to provide references for clinical practice and promote the further application and development of this technology in oral and maxillofacial surgery.
Printing, Three-Dimensional
;
Humans
;
Plastic Surgery Procedures/methods*
;
Mouth Neoplasms/surgery*
5.Three-dimensional (3D) printing-assisted freeze-casting of processed pyritum-doped β-tricalcium phosphate biomimetic scaffold with angiogenesis and bone regeneration capability.
Chenxu WEI ; Zongan LI ; Xiaoyun LIANG ; Yuwei ZHAO ; Xingyu ZHU ; Haibing HUA ; Guobao CHEN ; Kunming QIN ; Zhipeng CHEN ; Changcan SHI ; Feng ZHANG ; Weidong LI
Journal of Zhejiang University. Science. B 2025;26(9):863-880
Bone repair remains an important target in tissue engineering, making the development of bioactive scaffolds for effective bone defect repair a critical objective. In this study, β-tricalcium phosphate (β-TCP) scaffolds incorporated with processed pyritum decoction (PPD) were fabricated using three-dimensional (3D) printing-assisted freeze-casting. The produced composite scaffolds were evaluated for their mechanical strength, physicochemical properties, biocompatibility, in vitro pro-angiogenic activity, and in vivo efficacy in repairing rabbit femoral defects. They not only demonstrated excellent physicochemical properties, enhanced mechanical strength, and good biosafety but also significantly promoted the proliferation, migration, and aggregation of pro-angiogenic human umbilical vein endothelial cells (HUVECs). In vivo studies revealed that all scaffold groups facilitated osteogenesis at the bone defect site, with the β-TCP scaffolds loaded with PPD markedly enhancing the expression of neurogenic locus Notch homolog protein 1 (Notch1), vascular endothelial growth factor (VEGF), bone morphogenetic protein-2 (BMP-2), and osteopontin (OPN). Overall, the scaffolds developed in this study exhibited strong angiogenic and osteogenic capabilities both in vitro and in vivo. The incorporation of PPD notably promoted the angiogenic-osteogenic coupling, thereby accelerating bone repair, which suggests that PPD is a promising material for bone repair and that the PPD/β-TCP scaffolds hold great potential as a bone graft alternative.
Calcium Phosphates/chemistry*
;
Animals
;
Bone Regeneration
;
Rabbits
;
Tissue Scaffolds
;
Printing, Three-Dimensional
;
Humans
;
Human Umbilical Vein Endothelial Cells
;
Neovascularization, Physiologic
;
Osteogenesis
;
Tissue Engineering/methods*
;
Biomimetic Materials
;
Cell Proliferation
;
Angiogenesis
6.Expert consensus on digital restoration of complete dentures.
Yue FENG ; Zhihong FENG ; Jing LI ; Jihua CHEN ; Haiyang YU ; Xinquan JIANG ; Yongsheng ZHOU ; Yumei ZHANG ; Cui HUANG ; Baiping FU ; Yan WANG ; Hui CHENG ; Jianfeng MA ; Qingsong JIANG ; Hongbing LIAO ; Chufan MA ; Weicai LIU ; Guofeng WU ; Sheng YANG ; Zhe WU ; Shizhu BAI ; Ming FANG ; Yan DONG ; Jiang WU ; Lin NIU ; Ling ZHANG ; Fu WANG ; Lina NIU
International Journal of Oral Science 2025;17(1):58-58
Digital technologies have become an integral part of complete denture restoration. With advancement in computer-aided design and computer-aided manufacturing (CAD/CAM), tools such as intraoral scanning, facial scanning, 3D printing, and numerical control machining are reshaping the workflow of complete denture restoration. Unlike conventional methods that rely heavily on clinical experience and manual techniques, digital technologies offer greater precision, predictability, and efficacy. They also streamline the process by reducing the number of patient visits and improving overall comfort. Despite these improvements, the clinical application of digital complete denture restoration still faces challenges that require further standardization. The major issues include appropriate case selection, establishing consistent digital workflows, and evaluating long-term outcomes. To address these challenges and provide clinical guidance for practitioners, this expert consensus outlines the principles, advantages, and limitations of digital complete denture technology. The aim of this review was to offer practical recommendations on indications, clinical procedures and precautions, evaluation metrics, and outcome assessment to support digital restoration of complete denture in clinical practice.
Humans
;
Denture, Complete
;
Computer-Aided Design
;
Denture Design/methods*
;
Consensus
;
Printing, Three-Dimensional
7.Key role of biomechanical properties and material selection in rotator cuff repair.
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1606-1614
OBJECTIVE:
To summarize the biomechanical research progress of biomaterials in rotator cuff injury repair and to explore how biomaterials can restore the native histological and mechanical properties of the rotator cuff.
METHODS:
The relevant literature at home and abroad was widely reviewed to analyze the biomechanical properties of synthetic biomaterials, naturally derived biomaterials, and tissue grafts in the repair of rotator cuff injuries.
RESULTS:
Synthetic biomaterials [such as poly (lactic-co-glycolic acid) and polycaprolactone] can provide initial stable mechanical support due to their adjustable mechanical properties and degradation characteristics, while naturally derived biomaterials (such as collagen and hyaluronic acid) can promote cell adhesion and tissue integration due to their biocompatibility and bioactivity. Tissue grafts exhibit significant clinical utility by providing immediate mechanical stability and promoting tendon-to-bone healing. Three-dimensional bioprinting technology provides new possibilities for personalized repair of rotator cuff injuries by precisely controlling the spatial distribution and mechanical properties of biomaterials.
CONCLUSION
Future studies should further optimize the design of bioprinting materials, cell sources, and scaffolds to achieve better mechanical properties and clinical efficacy of biomaterials in the repair of rotator cuff injuries.
Humans
;
Rotator Cuff Injuries
;
Biocompatible Materials/chemistry*
;
Biomechanical Phenomena
;
Tissue Scaffolds
;
Rotator Cuff/surgery*
;
Tissue Engineering/methods*
;
Polyesters
;
Polyglycolic Acid/chemistry*
;
Hyaluronic Acid/chemistry*
;
Collagen/chemistry*
;
Lactic Acid/chemistry*
;
Polylactic Acid-Polyglycolic Acid Copolymer
;
Bioprinting
;
Wound Healing
;
Printing, Three-Dimensional
;
Tendon Injuries/surgery*
8.Early clinical outcomes of 3D-printed individualised customised prostheses in hip revision combined severe bone defect.
Hong-Ping WANG ; Ming-You WANG ; Xiao-Qin YANG ; Zhuo-Dong TANG ; Xun-Zhou SONG ; Yu-Ping LAN
China Journal of Orthopaedics and Traumatology 2025;38(2):163-169
OBJECTIVE:
To explore the early clinical outcomes of 3D printed individualised customised prostheses for in hip revision in patients with combined severe bone defects.
METHODS:
Twenty-two patients from January 2021 to May 2023 underwent hip revision using 3D printed personalised customised prostheses were retrospective analyzed, including 10 males and 12 females, age 28 to 78 with a mean of (58.9±12.8) years old. All of patients were combined with severe bone defects (Parprosky type Ⅲ). Among of them, 9 patients had periprosthetic infections and 13 patients had aseptic prosthesis loosening. All patients were treated with a 3D printed personalised prosthesis protocol, patients with the periprosthetic infection received a second stage revision after infection control. The operation time, preoperative waiting time, intraoperative and postoperative complications were recorded, and the clinical efficacy were evaluated at the final follow-up using the visual analogue scale (VAS) for pain, the Harris hip score.
RESULTS:
One patient was lost to follow-up and the remaining 21 patients were followed up for 10 to 15 with a mean of (12.91±1.44) months after surgery. All patients completed surgery as planned, with an operative time of 135 to 390 with a mean of (165.4±39.3) minutes and a preoperative waiting time of 7 to 16 with a mean of (10.5±3.3) days. Regarding patient complications:one patient had a severe intraoperative periprosthetic femoral fracture due to the combination of severe osteoporosis; one patient had an intraoperative greater trochanteric femur fracture. At the latest follow-up, all patients had good position of the custom-made prosthesis and no loosening of the prosthesis;all patients had good wound healing and no local redness or swelling. The total Harris score at the final follow-up (85.86±7.04) was significantly improved compared to the preoperative (44.86±2.36), P<0.001. The VAS at the last follow-up (2.19±0.87) was significantly improved compared with preoperative (7.41±0.96), P<0.001.
CONCLUSION
The clinical efficacy of 3D-printed personalised customised prosthesis in combined severe bone defect hip revision is satisfactory, but due to the increased preoperative waiting time of the patients and certain risks, certain indications should be mastered when applying in the clinic.
Humans
;
Male
;
Female
;
Printing, Three-Dimensional
;
Middle Aged
;
Aged
;
Adult
;
Retrospective Studies
;
Hip Prosthesis
;
Arthroplasty, Replacement, Hip
;
Reoperation
;
Prosthesis Design
;
Treatment Outcome
9.Clinical application of three-dimensional printing technology combined with customized bone plate in the treatment of acetabulum fracture.
Yan-Chao ZANG ; Quan-Yong ZHAO ; Li YANG ; Jin-Zeng ZUO ; Wei QI ; Wei-Dong LIANG ; Jie XING
China Journal of Orthopaedics and Traumatology 2025;38(2):203-207
OBJECTIVE:
To explore the application value and clinical effect of 3D printing combined with customized bone plate in the treatment of acetabular fracture.
METHODS:
From June 2020 to June 2022, 11 patients with acetabular fractures underwent preoperative planning using 3D printing technology and were treated with customized bone plates including 8 males and 3 females, aged 25 to 66 years old. The fractures were classified according to Letournel-Judet:4 posterior wall fractures, 2 T-type fractures, 2 transverse posterior wall fractures, 2 double column fractures, and 1 anterior column with posterior semi-transverse fractures. The operative time, intraoperative blood loss, intraoperative fluoroscopy times, postoperative drainage volume, postoperative fracture healing time, and hip function score were recorded and analyzed.
RESULTS:
The operation time of 11 patients was 80 to 150 min, intraoperative blood volume was 150 to 700 ml, fluoroscopy frequency was 2 to 6, postoperative drainage flow was 60 to 195 ml, and the fracture healing time was 2.5 to 6.0 months. Fracture reduction was evaluated according to Matta score:anatomical reduction in 3 cases and satisfactory reduction in 8 cases. Eleven patients were followed up for 7 to 18 months. The hip Merle d'Aubigne function scores were excellent in 6 cases, good in 3 cases, fair in 1 case and poor in 1 case. Incision fat liquefaction occurred in 1 case and obturator nerve traction in 1 case.
CONCLUSION
The application of 3D printing technology combined with customized bone plates in the treatment of acetabular fracture is effective. In addition, the printed model can provide the operator with the results of the three-dimensional shape of the fracture, which is convenient for surgical reduction and effectively improves the efficiency of surgery.
Humans
;
Female
;
Male
;
Middle Aged
;
Acetabulum/surgery*
;
Printing, Three-Dimensional
;
Adult
;
Aged
;
Bone Plates
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/methods*
10.Digital study of IdebergⅡregional pelvic fracture anatomical plate based on 3D metal printing technology.
Yi ZHANG ; Jia-Kai ZHANG ; Jun-Long WU ; Yi ZHENG
China Journal of Orthopaedics and Traumatology 2025;38(3):293-297
OBJECTIVE:
To establish digital model of Ideberg typeⅡregional glenoid fracture anatomical plate with 3D metal printing technology.
METHODS:
The scapular imaging data of a 34-year-old healthy male volunteer were retrospectively selected. Mimics 15.01, NX 12.0 and other software were used to design Ideberg typeⅡ regional scapular fracture guide plate system. STL data were input into a metal 3D printer to print 1∶1 scapular model and anatomical plate of scapular pelvis with guide sleeve. The fit of the plate was tested in vitro and the accuracy of the screw position was evaluated by imaging. The printing time of scapular model, design of the nail path and making time of the anatomic guided plate were recorded.
RESULTS:
3D metal-printed Ideberg typeⅡ guide plate for scapular fracture fitted well to 3D printed scapular model, the locking screw was oriented accurately, and X-ray and CT showed good screw position. The printing time of scapula model, time of nail path design and special-shaped anatomical guide plate production were 52.0, 15.0 and 320 min, respectively.
CONCLUSION
Anatomical plates based on 3D metal printing technology could achieve good adhesion of Ideberg typeⅡ regional fractures and precise screw placement, providing a new and accurate surgical method for the treatment of Ideberg typeⅡ glenoid fractures.
Humans
;
Printing, Three-Dimensional
;
Male
;
Adult
;
Bone Plates
;
Fractures, Bone/diagnostic imaging*
;
Fracture Fixation, Internal/methods*
;
Pelvic Bones/surgery*
;
Metals
;
Scapula/surgery*
;
Models, Anatomic

Result Analysis
Print
Save
E-mail