This study explores whether the current external quality assessment (EQA) level and acceptable bias for basic semen analysis in China are clinically useful. We collected data of semen EQA from Andrology laboratories in the Hunan Province (China) in 2022 and searched for data in the published literature from January 2000 to December 2023 in China. On the basis of these data, we analyzed the coefficients of variation and acceptable biases of different quality control materials for basic semen analysis through robust statistics. We compared these findings with quality specifications based on biological variation from optimal, desirable, and minimum levels of bias to seek a unified and more suitable semen EQA bias evaluation standard for China's national conditions. Different sources of semen quality control material exhibited considerable variation in acceptable biases among laboratories, ranging from 8.2% to 56.9%. A total of 50.0% of the laboratories met the minimum quality specifications for progressive motility (PR), whereas 100.0% and 75.0% of laboratories met only the minimum quality specifications for sperm concentration and total motility (nonprogressive [NP] + PR), respectively. The Z value for sperm concentration and PR+NP was equivalent to the desirable performance specification, whereas the Z value for PR was equivalent only to the minimum performance specification. This study highlights the feasibility of operating external quality assessment schemes for basic semen analysis using quality specifications based on biological variation. These specifications should be unified among external quality control (EQC) centers based on biological variation.
Semen Analysis/standards*
;
Humans
;
China
;
Male
;
Quality Control
;
Sperm Motility
;
Sperm Count/standards*
2.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
3.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
4.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
5.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
6.Usage and Dosage Analysis and Countermeasures for Development of Compound Preparations of Han Dynasty Famous Classical Formulas
Yan JIN ; Bing LI ; Wei ZHANG ; Huasheng PENG ; Huamin ZHANG ; Huihui LIU ; Lin ZHANG ; Zhilai ZHAN
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(7):1-10
In order to provide a reference basis for the development of relevant compound preparations, this article takes a comprehensive analysis of the usage and dosage of famous classical formulas in Han dynasty from various perspectives, and gives corresponding countermeasures on this basis. Through the comprehensive analysis of the classification and statistics of Zhongjing's medication characteristics, decoction methods, administration and dosage, and combining conversion methods of weights and measures by ancient medical practitioners, along with the dosage and administration of the listed Han dynasty famous classical formulas, it was found that the "Jiangxi method" served as a general guideline for administration according to Zhongjing's original text. This method allowed for flexible dosing based on the conversion of the ancient measurements to modern equivalents[13.8 g per Liang(两)], ensuring the safe and effective medication of these formulas. After combing, it is found that although the dosage of single medicine is large in famous classical formulas from Han dynasty, the administration is flexible. The crude drug amount per administration serves as the foundational dose, with the frequency of administration adjusted flexibly according to the condition. This dosing approach becomes the key for the rational development of compound formulations of famous classical formulas. Based on the conclusions of the study, it is recommended that when developing compound formulations of famous classical formulas in Han dynasty, the original administration method and dosage should be respected. The original crude drug amount per administration should be considered as the daily foundational dose, with the frequency of administration described within a range(1 to N times per day, where N is the maximum number of administrations as per the original text). The specific frequency of administration can be adjusted flexibly by clinical practitioners based on the individual condition. This approach should also be adopted in toxicological studies, where the dosage per administration serves as the basis for toxicity research, and the toxicity profile at the maximum administration frequency should be observed, providing guidance on the clinical safety range. Corresponding drug labels should provide information within a range to indicate toxicological risk intervals.
7.Efficacy-driving Mechanism of Danhong Injection for Stable Angina Pectoris Based on Composition-activity Relationship of Target Modules
Siwei TIAN ; Wenjing ZONG ; Jun LIU ; Wei YANG ; Qikai NIU ; Siqi ZHANG ; Jing'ai WANG ; Huamin ZHANG ; Zhong WANG ; Bing LI
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(23):121-128
ObjectiveTo explore the efficacy-driving mechanism of Danhong injection (DHI) in the treatment of stable angina pectoris (SAP) based on the composition-activity relationship of target modules and clarify the pharmacological effects of DHI. MethodAccording to the angina frequency (AF) in the Seattle Angina Questionnaire (SAQ) that was obtained in the previous clinical trial, the patients before and after DHI treatment were grouped based on efficacy. The transcriptomic data of the patients before treatment and in the best efficacy group 30 days post-treatment were selected as the data source, and then weighted gene co-expression network analysis (WGCNA) was employed to construct the co-expression network. Relevant modules in the network were identified and associated with clinical features. In addition, the On-modules (Z value below 0) were identified by Zsummary. The topological indicators such as density, centrality, and clustering coefficient were adopted to explore the dynamics of DHI efficacy at the network level and module level, respectively. In addition, the driver genes were screened by the personalized network control (PNC) algorithm. Finally, rat H9C2 cells were used to establish the model of hypoxia/reoxygenation (H/R), which was used to confirm the potential therapeutic target of DHI for SAP and provide a scientific basis for revealing the therapeutic mechanism of DHI. ResultWe identified 19 modules in the best efficacy group of DHI for SAP, and the comparison between day 0 and day 30 revealed 12 On-modules. The changes of network topological indicators at the network and module levels confirmed the correlation between the best efficacy of DHI treatment and topological dynamics. Finally, the driver genes, Klotho and fibroblast growth factor 22 (FGF22), in DHI treatment of SAP were verified by the H9C2 cell model of H/R. ConclusionBased on clinical transcriptome data, this study determined the composition-activity relationship of target modules of DHI for SAP, which provided a scientific basis for deciphering the efficacy-driven mechanism of DHI for SAP.
8.Quality of moxa from Artemisia argyi and A. stolonifera in different storage years based on simultaneous thermal analysis.
Bing YI ; Jia-Qi QIAO ; Li-Chun ZHAO ; Xian-Zhang HUANG ; Da-Hui LIU ; Li ZHOU ; Li-Ping KANG ; Yuan ZHANG
China Journal of Chinese Materia Medica 2023;48(14):3693-3700
The quality of moxa is an important factor affecting moxibustion therapy, and traditionally, 3-year moxa is considered optimal, although scientific data are lacking. This study focused on 1-year and 3-year moxa from Artemisia stolonifera and A. argyi(leaf-to-moxa ratio of 10∶1) as research objects. Scanning electron microscopy(SEM), Van Soest method, and simultaneous thermal analysis were used to investigate the differences in the combustion heat quality of 1-year and 3-year moxa and their influencing factors. The results showed that the combustion of A. stolonifera moxa exhibited a balanced heat release pattern. The 3-year moxa released a concentrated heat of 9 998.84 mJ·mg~(-1)(accounting for 54% of the total heat release) in the temperature range of 140-302 ℃, with a heat production efficiency of 122 mW·mg~(-1). It further released 7 512.51 mJ·mg~(-1)(accounting for 41% of the total heat release) in the temperature range of 302-519 ℃. The combustion of A. argyi moxa showed a rapid heat release pattern. The 3-year moxa released a heat of 16 695.28 mJ·mg~(-1)(accounting for 70% of the total heat release) in the temperature range of 140-311 ℃, with an instantaneous power output of 218 mW·mg~(-1). It further released 5 996.95 mJ·mg~(-1)(accounting for 25% of the total heat release) in the temperature range of 311-483 ℃. Combustion parameters such as-R_p,-R_v, D_i, C, and D_b indicated that the combustion heat quality of 3-year moxa was superior to that of 1-year moxa. It exhibited greater combustion heat, heat production efficiency, flammability, mild and sustained burning, and higher instantaneous combustion efficiency. This study utilized scientific data to demonstrate that A. stolonifera could be used as excellent moxa, and the quality of 3-year moxa surpassed that of 1-year moxa. The research results provide a scientific basis for the in-depth development of A. stolonifera moxa and the improvement of moxa quality standards.
Artemisia
;
Hot Temperature
;
Moxibustion
;
Plant Leaves
9.Quality of moxa with different leaf-to-moxa ratios based on correlation analysis of thermogravimetric properties, cellulose content, and microscopic characteristics of non-secretory trichomes.
Bing YI ; Li-Ping KANG ; Xin-Yu ZHAO ; Chi ZHANG ; Xin ZOU ; Liu-Jia CHAN ; Hong-Mei LI ; Xian-Zhang HUANG ; Li-Chun ZHAO ; Yuan ZHANG
China Journal of Chinese Materia Medica 2023;48(18):4950-4958
The quality of moxa is a key factor affecting the efficacy of moxibustion. Traditional moxa grades are evaluated by the leaf-to-moxa ratio, but there is a lack of support from scientific data. Scanning electron microscopy(SEM), Image Pro Plus, Van Soest method, and stimultaneous thermal analysis(TGA/DSC) were used to characterize the scientific implication of the combustion differences between moxa with different leaf-to-moxa ratios(processed by crusher). The results showed that the median lengths from non-secretory trichomes(NSTs) of natural NSTs and moxa with leaf-to-moxa ratios of 3∶1, 5∶1, 10∶1, and 15∶1 were 542.46, 303.24, 291.18, 220.69, and 170.61 μm, respectively. The cellulose content of moxa increased significantly(P<0.05) with the increase in leaf-to-moxa ratio and the combustion parameters(T_i, t_i, D_i, C,-R_p,-R_v, S, D_b, and J_(total)) all showed an increasing trend. The correlation results showed that the burning properties of moxa(T_i,-R_v, t_i, and J_2) were significantly and positively correlated with cellulose content. NSTs with a length of 1-200 μm were significantly and positively correlated with J_2. NSTs with a length of 200-600 μm were significantly and positively correlated with J_1, T_(peak2), T_(peak1), and-R_v, and negatively correlated with J_(total), T_b, and t_b. As the leaf-to-moxa ratio increases, the NSTs in the moxa become shorter and the cellulose content increases, which is more conducive to ignition performance, heat release, and a milder, longer-lasting burn. The "NSTs-cellulose-TGA/DSC" quantitative evaluation method scientifically reveals the scientific connotation of the combustion of moxa with different leaf-to-moxa ratios and provides a scientific basis for the establishment of quality evaluation methods for moxa with different leaf-to-moxa ratios.
Trichomes
;
Moxibustion
;
Hot Temperature
;
Plant Leaves
10.Analysis of the new WHO guideline to accelerate the progress towards elimination of schistosomiasis in China.
Zhao Yu GUO ; Jia Xin FENG ; Li Juan ZHANG ; Yi Biao ZHOU ; Jie ZHOU ; Kun YANG ; Yang LIU ; Dan Dan LIN ; Jian Bing LIU ; Yi DONG ; Tian Ping WANG ; Li Yong WEN ; Min Jun JI ; Zhong Dao WU ; Qing Wu JIANG ; Song LIANG ; Jia Gang GUO ; Chun Li CAO ; Jing XU ; Shan LÜ ; Shi Zhu LI ; Xiao Nong ZHOU
Chinese Journal of Schistosomiasis Control 2022;34(3):217-222
On February 2022, WHO released the evidence-based guideline on control and elimination of human schistosomiasis, with aims to guide the elimination of schistosomiasis as a public health problem in disease-endemic countries by 2030 and promote the interruption of schistosomiasis transmission across the world. Based on the One Health concept, six evidence-based recommendations were proposed in this guideline. This article aims to analyze the feasibility of key aspects of this guideline in Chinese national schistosomiasis control program and illustrate the significance to guide the future actions for Chinese national schistosomiasis control program. Currently, the One Health concept has been embodied in the Chinese national schistosomiasis control program. Based on this new WHO guideline, the following recommendations are proposed for the national schistosomiasis control program of China: (1) improving the systematic framework building, facilitating the agreement of the cross-sectoral consensus, and building a high-level leadership group; (2) optimizing the current human and livestock treatments in the national schistosomiasis control program of China; (3) developing highly sensitive and specific diagnostics and the framework for verifying elimination of schistosomiasis; (4) accelerating the progress towards elimination of schistosomiasis and other parasitic diseases through integrating the national control programs for other parasitic diseases.
China/epidemiology*
;
Disease Eradication
;
Humans
;
Public Health
;
Schistosomiasis/prevention & control*
;
World Health Organization

Result Analysis
Print
Save
E-mail