1.Efficacy analysis of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tubo-plasty on patulous eustachian tube
Jingcheng ZHOU ; Zhenhao FU ; Fangyuan WANG ; Jianping JIA ; Danheng ZHAO ; Ya LIU ; Li ZHU ; Kun HOU ; Mengyuan GUO ; Haoze ZHANG ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):418-423
Objective This study aimed to investigate the efficacy of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tuboplasty(MEACETT)in patients with patulous eustachian tube(PET).Meth-ods A retrospective analysis was conducted on the clinical data of 27 patients(30 ears)diagnosed with PET who underwent MEACETT.Autologous cartilage was used through the incision at the posterior end of the inferior turbi-nate and filled into the lateral wall of the pharyngeal orifice of the eustachian tube.Without affecting the movement function of the eustachian tube during swallowing,the collapse of the pharyngeal orifice was fully filled.Before and after the surgery,the visual analogue scale(VAS),the eustachian tube dysfunction questionnaire-7(ETDQ-7)and hospital anxiety and depression scale(HADS)was used for assessment to evaluate the surgical efficacy.Results There was no significant difference in depression scores before and after surgery(P>0.05).However,postopera-tive anxiety scores,ETDQ-7 scores,and VAS scores were significantly lower than preoperative scores(P<0.05).Among the 27 patients,9 showed significant symptom relief,13 exhibited partial relief,and 5 had no significant change compared to preoperative symptoms.The overall response rate of the treatment(significant relief and partial relief)was 81.48%(22/27).All surgeries were successfully performed.Except for secretory otitis media occurring in 2 cases,no major complications were observed.Conclusion MEACETT demonstrates significant symptom relief in PET patients,with high surgical safety and low complication rates,making it worthy of clinical promotion.
2.Research on the diagnostic efficiency of the"R"value of tubomanometry in detecting patulous eusta-chian tube
Zhenhao FU ; Jingcheng ZHOU ; Jianping JIA ; Fangyuan WANG ; Danheng ZHAO ; Ya LIU ; Haoze ZHANG ; Mengyuan GUO ; Li ZHU ; Kun HOU ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):429-433
Objective To evaluate the diagnostic efficacy of the R value in tubomanometry(TMM)for the di-agnosis of patulous eustachian tube(PET).Methods The clinical data of 58 patients with PET and 65 controls were retrospectively analyzed.TMM was performed on both groups under nasopharyngeal pressures of 30,40,and 50 mbar respectively.The diagnostic efficacy of the R value for PET was evaluated through receiver operating char-acteristic(ROC)curves.Results In the control group,the average R values under nasopharyngeal pressures of 30,40,and 50 mbar were 0.86±0.50,0.76±0.41,and 0.68±0.34 respectively.In contrast,the corresponding R values in the PET group were significantly lower,which were 0.56±0.38,0.50±0.36,and 0.46±0.38 respec-tively.According to the ROC curve analysis,the areas under the curve(AUC)at these pressures were 0.62,0.74,and 0.74 respectively.The specificity and sensitivity of the R value under nasopharyngeal pressures of 30,40,and 50 mbar were 76.90%and 54.30%,74.60%and 68.10%,86.90%and 54.30%,respectively.Under pressures of 30,40,and 50 mbar,the incidence rates of R>1 in the control group and the PET group were 29.23%(38/130)and 12.77%(12/94)(x2=8.69,P=0.003),20.00%(26/130)and 6.38%(6/94)(x2=7.20,P=0.007),10.00%(13/130)and 3.19%(3/94)(x2=2.87,P=0.09)respectively.Conclusion Although the low R value in TMM reflects the presence of PET to some extent,it does not provide adequate sensitivity and specificity to serve as an independent diagnostic criterion for PET.
3.Efficacy analysis of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tubo-plasty on patulous eustachian tube
Jingcheng ZHOU ; Zhenhao FU ; Fangyuan WANG ; Jianping JIA ; Danheng ZHAO ; Ya LIU ; Li ZHU ; Kun HOU ; Mengyuan GUO ; Haoze ZHANG ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):418-423
Objective This study aimed to investigate the efficacy of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tuboplasty(MEACETT)in patients with patulous eustachian tube(PET).Meth-ods A retrospective analysis was conducted on the clinical data of 27 patients(30 ears)diagnosed with PET who underwent MEACETT.Autologous cartilage was used through the incision at the posterior end of the inferior turbi-nate and filled into the lateral wall of the pharyngeal orifice of the eustachian tube.Without affecting the movement function of the eustachian tube during swallowing,the collapse of the pharyngeal orifice was fully filled.Before and after the surgery,the visual analogue scale(VAS),the eustachian tube dysfunction questionnaire-7(ETDQ-7)and hospital anxiety and depression scale(HADS)was used for assessment to evaluate the surgical efficacy.Results There was no significant difference in depression scores before and after surgery(P>0.05).However,postopera-tive anxiety scores,ETDQ-7 scores,and VAS scores were significantly lower than preoperative scores(P<0.05).Among the 27 patients,9 showed significant symptom relief,13 exhibited partial relief,and 5 had no significant change compared to preoperative symptoms.The overall response rate of the treatment(significant relief and partial relief)was 81.48%(22/27).All surgeries were successfully performed.Except for secretory otitis media occurring in 2 cases,no major complications were observed.Conclusion MEACETT demonstrates significant symptom relief in PET patients,with high surgical safety and low complication rates,making it worthy of clinical promotion.
4.Research on the diagnostic efficiency of the"R"value of tubomanometry in detecting patulous eusta-chian tube
Zhenhao FU ; Jingcheng ZHOU ; Jianping JIA ; Fangyuan WANG ; Danheng ZHAO ; Ya LIU ; Haoze ZHANG ; Mengyuan GUO ; Li ZHU ; Kun HOU ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):429-433
Objective To evaluate the diagnostic efficacy of the R value in tubomanometry(TMM)for the di-agnosis of patulous eustachian tube(PET).Methods The clinical data of 58 patients with PET and 65 controls were retrospectively analyzed.TMM was performed on both groups under nasopharyngeal pressures of 30,40,and 50 mbar respectively.The diagnostic efficacy of the R value for PET was evaluated through receiver operating char-acteristic(ROC)curves.Results In the control group,the average R values under nasopharyngeal pressures of 30,40,and 50 mbar were 0.86±0.50,0.76±0.41,and 0.68±0.34 respectively.In contrast,the corresponding R values in the PET group were significantly lower,which were 0.56±0.38,0.50±0.36,and 0.46±0.38 respec-tively.According to the ROC curve analysis,the areas under the curve(AUC)at these pressures were 0.62,0.74,and 0.74 respectively.The specificity and sensitivity of the R value under nasopharyngeal pressures of 30,40,and 50 mbar were 76.90%and 54.30%,74.60%and 68.10%,86.90%and 54.30%,respectively.Under pressures of 30,40,and 50 mbar,the incidence rates of R>1 in the control group and the PET group were 29.23%(38/130)and 12.77%(12/94)(x2=8.69,P=0.003),20.00%(26/130)and 6.38%(6/94)(x2=7.20,P=0.007),10.00%(13/130)and 3.19%(3/94)(x2=2.87,P=0.09)respectively.Conclusion Although the low R value in TMM reflects the presence of PET to some extent,it does not provide adequate sensitivity and specificity to serve as an independent diagnostic criterion for PET.
5.Study on preparation of 3D printing degradable tissue engineering ossicles
Xuexue LU ; Xuesheng LI ; Danheng ZHAO ; Jingyuan JI ; Busheng TONG ; Jianjun SUN
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2020;55(8):764-768
Objective:In combination with 3D printing technology and degradable composite materials, to discuss the preparation method of tissue engineering ossicles for middle ear hearing reconstruction.Methods:Domestic polymer (polylactic acid-glycolic acid copolymer, PLGA) and degradable ceramic material (β-tricalcium phosphate, β-TCP) were selected and prepared by low temperature deposition method according to the design ratio to Program according to the outline design code of the required scaffold to generate appropriate print files, and then the self-developed low-temperature deposition printing device was used to prepare tissue-engineered osseous scaffolds in accordance with the print files in a low-temperature environment. The scaffolds was freeze-dried and sterilized for later use after printing. Light microscopy and scanning electron microscopy were used to observe the apparent characteristics and internal structure of the scaffolds and to check its pore size, porosity and mechanical properties.Results:After printing, a degradable scaffold was obtained. Under the optical microscope, it was a small cylindrical shape with a diameter of 1.5 mm and a length of 6.0 mm, and its surface had micropores. The degradable scaffold had a horizontal and vertical interlaced warp and weft structure, the wire spacing was 1.2 mm, and the pores were connected to each other. The surface could see circular or quadrangular pores with a pore size of about 100-400 μm. The diameter of the inter-pore cross-linked channels was about 50 μm and the diameter of the surrounding circular micropores was about 10-40 μm. β-TCP particles with a size of about 700 nm were attached to the surface of the PLGA material. The average porosity of the whole scaffolds was (83.43±0.01)%, and the content of BMP-2 loaded was about 0.7 μg/mm 3. After freeze-drying, the mechanical strength of the scaffold was moderate, and there was no obvious deformation during stretching and compression, which met the mechanical requirements of tissue engineering ossicles. Conclusions:Using the low-temperature deposition printing method and strictly controlled processes and conditions, a polymer-degradable ceramic ossicle tissue engineering scaffold can be prepared for implantation experiments. The scaffold has suitable porosity and mechanical properties, and can be loaded with osteoinductive factors.
6. Congenital middle ear malformation: clinical analysis and discussion of classification
Yang LIU ; Danheng ZHAO ; Yongsheng LIN
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2019;54(7):481-488
Objective:
To analyze the clinical characteristics and appropriate surgical procedures, and discuss the classification of congenital middle ear malformation.
Methods:
All cases were from the Center of Otorhinolaryngology, the Sixth Medical Center of Department of PLA General Hospital. All of these cases, including 26 male patients (ears) , 10 female patients (11 ears) , aged from 7 to 57 years old, had normal external auditory canal, tympanic membrane, conductive hearing loss, type A tympanogram and negative Gelle′s test. Tympanoplasty was performed in all cases. The deformity was classified to three types,i.e., Type I (stapes foot plate mobility): Ⅰa, ossicular chain deformity with normal stapes suprastructure; Ⅰb, ossicular chain deformity with abnormal stapes suprastructure; Type Ⅱ (stapes foot plate fixation): Ⅱ a,normal ossicular chain, Ⅱ b, ossicular chain malformation; and Type Ⅲ: vestibular window osseous atresia or undeveloped, or with round window atresia. The malformation of type Ⅱ and Ⅲ may be accompanied with abnormal facial nerve. In addition, the papers on middle ear malformation published from 1982 to 2017 were analyzed retrospectively. The clinical data of 451 ears malformation were summarized.
Results:
According to the revisional classification criteria in 37 ear samples from our hospital, 20 ears were type I. 6 type Ⅰa cases were used PORP (partial ossicular replacement prosthesis) to reconstruct the ossicular chain; 14 type Ⅰb cases were used TORP (total ossicular replacement prosthesis) to reconstruct the ossicular chain. For the 5 ears of type Ⅱ, 2 of which were type Ⅱ a and 3 were type Ⅱ b. 4 ear samples of type Ⅱ were implanted with Piston ossicular prosthesis, 1 was implanted with TORP in which the ossificated foot plate was removed with periosteum preserved. 12 ear samples were type Ⅲ, with vestibular window osseous atresia, facial nerve malformation, and stapes suprastructure malformation. The pistons ossicular prosthesis were implanted in vestibular window in 3 ears with facial nerve covering vestibular window partially. The surgery had to be given up in 5 ears, and TORP was implanted in 4 ears at the opening with preserved periosteum at the beginning of the tympanic scala because of facial nerve covering vestibular window totally. 30 ears with complete follow-up data had no sensorineural hearing loss and the average air-bone conduction decreased 23.3±10.7 dB (
8.Staged tympanoplasty.
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2016;51(5):397-399
10.Epitympanoplasty with Cartilage Obliteration in the Canal Wall Up Technique to the Middle Ear Cholesteatoma
Danheng ZHAO ; Yang LIU ; Jianjun SUN ; Yongsheng LIN
Journal of Audiology and Speech Pathology 2013;(5):447-450
Objective To report the curative effect of the epitympanoplasty with cartilage obliteration in the treatment of middle ear cholesteatoma .Methods This study retrospectively analysed 123 cases ,with middle ear cholesteatoma treated in our department from November 2009 to July 2012 .The operation included mastoidectomy with posterior canal wall preserved ,lateral wall of attic resected ,facial recess opened to the epitympanum ,epitym-panum obliterated with cartilage and mastoid cavity blocked with bone dust .All cases were followed up on complica-tions and hearing improvement .Results All cases were followed up 6~38 months .In 123 cases ,there were 2 ca-ses had cholesteatoma recurrence in the middle ear cavity ,6 cases had infection of post auricular incision after opera-tion ,3 cases had residual marginal tympanic membrane perforation ,2 cases had ossicular replacement prosthesis ex-clusion ,and 6 cases had canal wall skin swelling or defect .The rest cases acquired full -recovery after 2 or 3 wound dressing changes .Out of 123 cases ,83 cases had the whole hearing document ,the average AB gap at 0 .5 ,1 ,2 kHz reduced from 32 .2 ± 11 .2 dB pre-operation to 20 .7 ± 12 .4 dB post -operation .The AB gap of pre - and post -operation had significant difference (P<0 .001) .Conclusion The mastoidectomy with posterior canal wall preserved greatly shortened the healing time .The resection of lateral wall of epitympanum can exposed operating field more completely and remove lesions thoroughly .The cartilage obliteration in the attic can prevent the retraction pocket formation effectively .This technique provides alternative in treating middle ear cholesteatoma .

Result Analysis
Print
Save