1.Comparative Analysis of Two Chemiluminescent Immunoassay Systems for the Detection of Serum HBsAg Mutants
Yong NI ; Dandan CHEN ; Meina GONG ; Xiang NI
Journal of Modern Laboratory Medicine 2025;40(3):195-198,220
Objective To analyze and compare the ability of two chemiluminescent immunoassay systems for detecting HBsAg mutant strains.Methods The two chemiluminescent immunoassay systems,I3000 and Liaison XL,were used to detect nine HBsAg mutant strains with known HBsAg mutation sites respectively,and to compare the detection ability of these two systems for the nine HBsAg mutant strains.The clinical serum samples that were negative for HBsAg by the I3000 system were reviewed by the Liaison XL system for HBsAg,qRT-PCR amplification primers were designed for the HBsAg mutant strains with positive results by the Liaison XL system,and fluorescence quantitative PCR and Hepatitis B serologic tests were performed on the clinical samples that had inconsistent negative-positive results between the two aforementioned systems.Results The Liaison XL detected all nine HBsAg mutant strains with known HBsAg mutation sites with positive results,whereas the I3000 detected six of them with positive but three with negative results.Using the Liaison XL system to test 1 520 samples from hospitalized patients who were negative for HBsAg with the I3000 detection system,four positive results were found,including one positive result by the fluorescence quantitative PCR assay,which belonged to the HBsAg mutant of the mutant strain P124L-F/Y143H-D144E-G145R and the patient's test values for HBeAb and HBcAb were high,suggesting that the patient was a minor triple positive.Conclusion Liaison XL can detect the P124L-F/Y143H-D144E-G145R HBsAg mutant in clinical samples,and it is very important to select HBsAg test reagents with strong HBsAg mutant recognition and capture ability.
2.Strategies for management of trauma orthopedic implant and effect on control of infections in operating rooms
Lin LIU ; Ying XU ; Lianen ZHANG ; Dandan NI ; Yun WANG ; Jing XIE ; Lanmei HE
Chinese Journal of Nosocomiology 2025;35(20):3168-3172
OBJECTIVE To explore the impact of trauma orthopedic implant management on the operating room in-fection control rate and the medical device vendor follow-up rate.METHODS Trauma orthopedic implant manage-ment was implemented at Shaoxing People's Hospital from Mar.2023 to Mar.2024,involving 2 047 trauma or-thopedic surgeries(study group).For comparison,a control group consisting of 2 067 trauma orthopedic surger-ies from Mar.2022 to Feb.2023 under routine management was selected.The impact of trauma orthopedic im-plant management on operating room efficiency,infection control rate and medical device vendor follow-up rate in both groups were analyzed.RESULTS The study group showed satisfaction rates of 78.65%and 91.35%for cir-culating cooperation familiarity and handwashing cooperation familiarity,respectively,both higher than those in the control group(P<0.001).The study group also demonstrated higher rates of standardized use of orthopedic trauma implants(96.43%),accurate item-code correspondence(98.19%)and timely availability(98.19%)than those in the control group,with a lower medical device vendor follow-up rate of 3.57%(P<0.001).The study group's monthly overtime hours,costs,time costs,average cost per re-disinfection and re-cleaning service and monthly re-disinfection re-cleaning frequency were 13.85 hours,235.86 yuan/day,25 233.51 yuan,0.35 yuan/time and 183.81 times/month,respectively,all lower than those in the control group(P<0.001).The study group had higher rates of consumable access compliance(99.22%),accurate charging(98.58%)and timely delivery(97.90%)than the control group(P<0.001).The study group also achieved a 100.00%implant regulatory recovery rate,higher than the control group(P<0.001).Furthermore,the surgical site infection rate in the study group was 1.91%,lower than that in the control group(P<0.001).CONCLUSIONS This study establishes a trauma orthopedic implant management system integrating supply chain management,an identification system and IoT technology.This model effectively addresses core issues such as the difficulty in regulating multiple vendors,blind spots in virtual warehousing and disorder in item-code tracing under the traditional vendor self-management model.It significantly improves operating room efficiency,reduces the surgical site infection rate,and achieves a notable decrease in the medical device vendor follow-up rate.
3.Relationship of RDW and blood lipid metabolism indicators with carotid atherosclerotic plaque stability in elderly patients with ACI
Yong NI ; Xiang WU ; Xianghai KONG ; Meina GONG ; Tingting LIU ; Dandan CHEN
Chinese Journal of Geriatric Heart Brain and Vessel Diseases 2025;27(9):1229-1232
Objective To analyze the relationship of red blood cell distribution width(RDW)and blood lipid metabolism indicators with carotid atherosclerotic plaque stability in elderly patients with acute cerebral infarction(ACI).Methods A total of 110 elderly ACI patients admitted in our hospital from March 2021 to November 2024 were retrospectively recruited,and according to their carotid plaque characteristics,they were divided into stable plaque group(48 cases)and unstable plaque group(62 cases).The RDW,and levels of TC,TG,HDLC,LDL-C and homocysteine(Hcy)were detected.Results The unstable plaque group had significantly higher levels of RDW,TC,TG,LDL-C and Hcy,but lower HDL-C level than the stable plaque group(P<0.01).RDW,TC,TG,HDL-C,LDL-C and Hcy were the influencing factors of carotid atherosclerotic plaque stability in elderly ACI patients(P<0.05,P<0.01).ROC curve analysis suggested that the AUC value of combined detection of RDW,TC,TG,HDL-C,LDL-C and Hcy in evaluating the stability of carotid atherosclerotic plaque was 0.940(95%CI:0.898~0.983),and the combination had bet-ter efficiency than single indicator detection(P<0.05).Conclusion RDW and blood lipid metabo-lism indicators are associated with the stability of carotid atherosclerotic plaque in elderly ACI patients,and they can be used as biochemical evaluation indicators for the stability.
4.Comparative Analysis of Two Chemiluminescent Immunoassay Systems for the Detection of Serum HBsAg Mutants
Yong NI ; Dandan CHEN ; Meina GONG ; Xiang NI
Journal of Modern Laboratory Medicine 2025;40(3):195-198,220
Objective To analyze and compare the ability of two chemiluminescent immunoassay systems for detecting HBsAg mutant strains.Methods The two chemiluminescent immunoassay systems,I3000 and Liaison XL,were used to detect nine HBsAg mutant strains with known HBsAg mutation sites respectively,and to compare the detection ability of these two systems for the nine HBsAg mutant strains.The clinical serum samples that were negative for HBsAg by the I3000 system were reviewed by the Liaison XL system for HBsAg,qRT-PCR amplification primers were designed for the HBsAg mutant strains with positive results by the Liaison XL system,and fluorescence quantitative PCR and Hepatitis B serologic tests were performed on the clinical samples that had inconsistent negative-positive results between the two aforementioned systems.Results The Liaison XL detected all nine HBsAg mutant strains with known HBsAg mutation sites with positive results,whereas the I3000 detected six of them with positive but three with negative results.Using the Liaison XL system to test 1 520 samples from hospitalized patients who were negative for HBsAg with the I3000 detection system,four positive results were found,including one positive result by the fluorescence quantitative PCR assay,which belonged to the HBsAg mutant of the mutant strain P124L-F/Y143H-D144E-G145R and the patient's test values for HBeAb and HBcAb were high,suggesting that the patient was a minor triple positive.Conclusion Liaison XL can detect the P124L-F/Y143H-D144E-G145R HBsAg mutant in clinical samples,and it is very important to select HBsAg test reagents with strong HBsAg mutant recognition and capture ability.
5.Strategies for management of trauma orthopedic implant and effect on control of infections in operating rooms
Lin LIU ; Ying XU ; Lianen ZHANG ; Dandan NI ; Yun WANG ; Jing XIE ; Lanmei HE
Chinese Journal of Nosocomiology 2025;35(20):3168-3172
OBJECTIVE To explore the impact of trauma orthopedic implant management on the operating room in-fection control rate and the medical device vendor follow-up rate.METHODS Trauma orthopedic implant manage-ment was implemented at Shaoxing People's Hospital from Mar.2023 to Mar.2024,involving 2 047 trauma or-thopedic surgeries(study group).For comparison,a control group consisting of 2 067 trauma orthopedic surger-ies from Mar.2022 to Feb.2023 under routine management was selected.The impact of trauma orthopedic im-plant management on operating room efficiency,infection control rate and medical device vendor follow-up rate in both groups were analyzed.RESULTS The study group showed satisfaction rates of 78.65%and 91.35%for cir-culating cooperation familiarity and handwashing cooperation familiarity,respectively,both higher than those in the control group(P<0.001).The study group also demonstrated higher rates of standardized use of orthopedic trauma implants(96.43%),accurate item-code correspondence(98.19%)and timely availability(98.19%)than those in the control group,with a lower medical device vendor follow-up rate of 3.57%(P<0.001).The study group's monthly overtime hours,costs,time costs,average cost per re-disinfection and re-cleaning service and monthly re-disinfection re-cleaning frequency were 13.85 hours,235.86 yuan/day,25 233.51 yuan,0.35 yuan/time and 183.81 times/month,respectively,all lower than those in the control group(P<0.001).The study group had higher rates of consumable access compliance(99.22%),accurate charging(98.58%)and timely delivery(97.90%)than the control group(P<0.001).The study group also achieved a 100.00%implant regulatory recovery rate,higher than the control group(P<0.001).Furthermore,the surgical site infection rate in the study group was 1.91%,lower than that in the control group(P<0.001).CONCLUSIONS This study establishes a trauma orthopedic implant management system integrating supply chain management,an identification system and IoT technology.This model effectively addresses core issues such as the difficulty in regulating multiple vendors,blind spots in virtual warehousing and disorder in item-code tracing under the traditional vendor self-management model.It significantly improves operating room efficiency,reduces the surgical site infection rate,and achieves a notable decrease in the medical device vendor follow-up rate.
6.Relationship of RDW and blood lipid metabolism indicators with carotid atherosclerotic plaque stability in elderly patients with ACI
Yong NI ; Xiang WU ; Xianghai KONG ; Meina GONG ; Tingting LIU ; Dandan CHEN
Chinese Journal of Geriatric Heart Brain and Vessel Diseases 2025;27(9):1229-1232
Objective To analyze the relationship of red blood cell distribution width(RDW)and blood lipid metabolism indicators with carotid atherosclerotic plaque stability in elderly patients with acute cerebral infarction(ACI).Methods A total of 110 elderly ACI patients admitted in our hospital from March 2021 to November 2024 were retrospectively recruited,and according to their carotid plaque characteristics,they were divided into stable plaque group(48 cases)and unstable plaque group(62 cases).The RDW,and levels of TC,TG,HDLC,LDL-C and homocysteine(Hcy)were detected.Results The unstable plaque group had significantly higher levels of RDW,TC,TG,LDL-C and Hcy,but lower HDL-C level than the stable plaque group(P<0.01).RDW,TC,TG,HDL-C,LDL-C and Hcy were the influencing factors of carotid atherosclerotic plaque stability in elderly ACI patients(P<0.05,P<0.01).ROC curve analysis suggested that the AUC value of combined detection of RDW,TC,TG,HDL-C,LDL-C and Hcy in evaluating the stability of carotid atherosclerotic plaque was 0.940(95%CI:0.898~0.983),and the combination had bet-ter efficiency than single indicator detection(P<0.05).Conclusion RDW and blood lipid metabo-lism indicators are associated with the stability of carotid atherosclerotic plaque in elderly ACI patients,and they can be used as biochemical evaluation indicators for the stability.
7.Nomogram including serum ferritin to predict the occurrence of diabetic retinopathy
Xiaoyu WU ; Dandan XIE ; Jiana CHEN ; Lianhong NI ; Weina LI
International Eye Science 2024;24(5):671-676
AIM:To establish a nomogram model to predict the effect of serum ferritin on diabetic retinopathy and evaluate the model.METHODS:A total of 21 variables, including ferritin, were screened by univariate and multivariate regression analysis to determine the risk factors of diabetic retinopathy. A nomogram prediction model was established for evaluation and calibration.RESULTS:Ferritin, duration of diabetes, hemoglobin, urine microalbumin, regularity of medication and body mass index were included in the nomogram model. The consistency index of the prediction model with serum ferritin was 0.813(95%CI: 0.748-0.879). The calibration curves of internal and external verification showed good performance, and the probability of the threshold suggested by the decision curve was in the range 10% to 90%. The model had a high net profit value.CONCLUSIONS:Serum ferritin is an important risk factor for diabetic retinopathy. A new nomogram model, which includes body mass index, duration of diabetes, ferritin, hemoglobin, urine microalbumin and regularity of medication, has a high predictive accuracy and could provide early prediction for clinicians.
8.Immune-Enhancing Treatment among Acute Necrotizing Pancreatitis Patients with Metabolic Abnormalities: A Post Hoc Analysis of a Randomized Clinical Trial
Xiaofei HUANG ; Wenjian MAO ; Xingxing HU ; Fengxia QIN ; Hui ZHAO ; Aiping ZHANG ; Xinyu WANG ; Christian STOPPE ; Dandan ZHOU ; Lu KE ; Haibin NI ; Chinese Acute Pancreatitis Clinical Trials Group (CAPCTG)
Gut and Liver 2024;18(5):906-914
Background/Aims:
Metabolic syndrome is common in patients with acute pancreatitis and its components have been reported to be associated with infectious complications. In this post hoc analysis, we aimed to evaluate whether metabolic abnormalities impact the effect of immuneenhancing thymosin alpha-1 (Tα1) therapy in acute necrotizing pancreatitis (ANP) patients.
Methods:
All data were obtained from the database for a multicenter randomized clinical trial that evaluated the efficacy of Tα1 in ANP patients. Patients who discontinued the Tα1 treatment prematurely were excluded. The primary outcome was 90-day infected pancreatic necrosis (IPN) after randomization. Three post hoc subgroups were defined based on the presence of hyperglycemia, hypertriglyceridemia, or both at the time of randomization. In each subgroup, the correlation between Tα1 and 90-day IPN was assessed using the Cox proportional-hazards regression model. Multivariable propensity-score methods were used to control potential bias.
Results:
Overall, 502 participants were included in this post hoc analysis (248 received Tα1 treatment and 254 received matching placebo treatment). Among them, 271 (54.0%) had hyperglycemia, 371 (73.9%) had hypertriglyceridemia and 229 (45.6%) had both. Tα1 therapy was associated with reduced incidence of IPN among patients with hyperglycemia (18.8% vs 29.7%: hazard ratio, 0.80; 95% confidence interval, 0.37 to 0.97; p=0.03), but not in the other subgroups. Additional multivariate regression models using three propensity-score methods yielded similar results.
Conclusions
Among ANP patients with hyperglycemia, immune-enhancing Tα1 treatment was associated with a reduced risk of IPN (ClinicalTrials.gov, Registry number: NCT02473406).
9.Study of extracting key plane of 11-13 + 6 weeks normal fetal palate by three-dimensional ultrasound based on artificial intelligence
Wenxiong PAN ; Dandan ZHANG ; Ruijuan PAN ; Yuhao HUANG ; Shihua DENG ; Yuanji ZHANG ; Mali ZHENG ; Dong NI ; Mei LI ; Yi XIONG
Chinese Journal of Ultrasonography 2023;32(3):227-233
Objective:To explore the feasibility of extracting the key plane of the normal fetal palate on the 11-13 + 6 week from tomography ultrasonography imaging based on artificial intelligence. Methods:The fetal volume datas of 235 cases of 11-13 + 6 week normal fetal were collected from the Department of Ultrasound in the Luohu District People′s Hospital of Shenzhen and Huazhong University of Science and Technology Union Shenzhen Hospital from May 2020 to April 2021. The data acquisition was completed by sonographers A and B by using the GE Voluson E10 color Doppler ultrasound diagnostic instrument. All datas were marked offline by sonographer C. Tomographic imaging was performed on all included data by sonographer D, the tomographic images were saved and the time-consuming was recorded, and the datas of the sonographer group were obtained. The labeled data were randomly divided into the training set and test set for model transfer learning and testing.The 4-fold cross-validation was adopted to record the test set image output by the model and the time consumption to obtain the intelligent group data. A senior sonographer performed image analysis on the two groups of data images. The feasibility of the intelligent model was verified by comparing the score of the plane of retronasal triangle(RTP), the acquisition rate of RTP, the acquisition rate of the fault, and the time-consuming difference between the sonographer group and the intelligent group. Results:①There was no significant difference in the overall distribution of RTP scores between the sonographer group and intelligent group [5 (5, 6) points vs 5 (5, 6) points, Z=0.355, P=0.722]. The RTP acquisition rate of the sonographer group and intelligent group was not statistically significant (78.72% vs 76.60%, χ 2=0.55, P=0.458). The consistency and correlation of RTP obtained by the two groups were high (Kappa=0.645, φ=0.646, both P<0.001). ②The effective layers of the sonographer group were 9 (8, 9) and the intelligent group was 8 (7, 9). The fault acquisition rate of the doctor group was higher than that of the intelligent group (78.72% vs 68.51%, χ 2=12.52, P=0.001). The consistency and correlation of the two groups in obtaining faults were media (Kappa=0.503, φ=0.521, both P<0.001). ③The time-consuming of the intelligent group was significantly lower than that of the sonographer group [1.50 (1.23, 1.75)s vs 26.94 (22.28, 30.48)s, Z=11.440, P<0.001]. Conclusions:This research model can quickly and accurately realize the extraction and tomography of the key plane of the normal fetal palate on the 11-13 + 6 week.
10.Practice of a hemodialysis alliance in the context of closed-loop hospital management
Jing QIAN ; Mengjing WANG ; Chuhan LU ; Ping CHENG ; Li NI ; Wei LIU ; Bihong HUANG ; Zhibin YE ; Zhenwen YAN ; Qianqiu CHENG ; Chen YU ; Aili WANG ; Ai PENG ; Wei XU ; Chunlai LU ; Dandan CHEN ; Xiuzhi YU ; Liyan FEI ; Jun MA ; Jialan SHEN ; Junhui LI ; Ying LI ; Lingyun CHEN ; Weifeng WU ; Rongqiang YU ; Lihua XU ; Jing CHEN
Chinese Journal of Hospital Administration 2022;38(8):595-599
Closed-loop hospital management can effectivly cope with the COVID-19 pandemic. In order to ensure the continuity of treatments for hemodialysis patients under closed-loop management and minimize possible medical and infection risks, Huashan Hospital affiliated to Fudan University and 9 hospitals in Shanghai established a hemodialysis alliance in January 2021.The alliance optimized hemodialysis resources within the region through overall planning by preparing sites, materials and personnel shifts in advance, and establishing management systems and work processes to ensure that patients could be quickly and orderly diverted to other blood dialysis centers for uninterrupted high-quality hemodialysis services, in case that some hemodialysis centers in the alliance under closed-loop management.From November 2021 to April 2022, 317 of 1 459 hemodialysis patients in the alliance were diverted to other centers for treatment, accumulating 1 215 times/cases of treatments without obvious adverse reactions. The practice could provide a reference for medical institutions to quickly establish mutual support mode under major public health events.

Result Analysis
Print
Save
E-mail