1.Restoration of osteogenic differentiation of bone marrow mesenchymal stem cells in mice inhibited by cyclophosphamide with psoralen
Chenglong WANG ; Zhilie YANG ; Junli CHANG ; Yongjian ZHAO ; Dongfeng ZHAO ; Weiwei DAI ; Hongjin WU ; Jie ZHANG ; Libo WANG ; Ying XIE ; Dezhi TANG ; Yongjun WANG ; Yanping YANG
Chinese Journal of Tissue Engineering Research 2025;29(1):16-23
BACKGROUND:Psoralen has a strong anti-osteoporotic activity and may have a restorative effect on chemotherapy-induced osteoporosis. OBJECTIVE:To explore the restorative effect of psoralen on the osteogenic differentiation of bone marrow mesenchymal stem cells in mice inhibited by cyclophosphamide and its mechanism. METHODS:C57BL/6 mouse bone marrow mesenchymal stem cells were isolated and cultured.Effect of psoralen on viability of bone marrow mesenchymal stem cells was detected by MTT assay.Osteogenic induction combined with alkaline phosphatase staining was used to determine the optimal dose of psoralen to restore the osteogenic differentiation of bone marrow mesenchymal stem cells inhibited by cyclophosphamide.The mRNA expression levels of Runx2,alkaline phosphatase,Osteocalcin,osteoprotegerin,and Wnt/β-catenin signaling pathway-related genes Wnt1,Wnt4,Wnt10b,β-catenin,and c-MYC were measured by RT-qPCR at different time points under the intervention with psoralen.The protein expression of osteogenic specific transcription factor Runx2 and Wnt/β-catenin signaling pathway related genes Active β-catenin,DKK1,c-MYC,and Cyclin D1 was determined by western blot assay at different time points under the intervention with psoralen. RESULTS AND CONCLUSION:(1)There was no significant effect of different concentrations of psoralen on the viability of bone marrow mesenchymal stem cells.The best recovery of the inhibition of osteogenic differentiation of bone marrow mesenchymal stem cells caused by cyclophosphamide was under the intervention of psoralen at a concentration of 200 μmol/L.(2)Psoralen reversed the reduction in osteogenic differentiation marker genes Runx2,alkaline phosphatase,Osteocalcin and osteoprotegerin mRNA expression and Runx2 protein expression in bone marrow mesenchymal stem cells caused by cyclophosphamide conditioned medium.(3)Psoralen reversed the decrease in Wnt/β-catenin pathway-related genes Wnt4,β-catenin,c-MYC mRNA and Active β-catenin,c-MYC,and Cyclin D1 protein expression and the increase in DKK1 protein expression in bone marrow mesenchymal stem cells caused by cyclophosphamide conditioned medium.(4)The results showed that cyclophosphamide inhibited osteogenic differentiation of bone marrow mesenchymal stem cells in mice,and psoralen had a restorative effect on it.The best intervention effect was achieved at a concentration of 200 μmol/L psoralen,and this protective effect might be related to the activation of Wnt4/β-catenin signaling pathway by psoralen.
2.Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique (version 2025)
Sihao HE ; Junchao XING ; Tongwei CHU ; Zhengqi CHANG ; Xigao CHENG ; Fei DAI ; Xiaobing JIANG ; Jie HAO ; Jiang HU ; Jinghui HUANG ; Tianyong HOU ; Fei LUO ; Bo LIAO ; Changqing LI ; Lei LIU ; Guodong LIU ; Peng LIU ; Sheng LU ; Weishi LI ; Yang LIU ; Zhen LIU ; Wei MEI ; Peifu TANG ; Bing WANG ; Bing WANG ; Ce WANG ; Hongli WANG ; Liang WANG ; Shengru WANG ; Xiaobin WANG ; Yang WANG ; Yingfeng WANG ; Zheng WANG ; Jianzhong XU ; Guoyong YIN ; Haiyang YU ; Qiang YANG ; Zhaoming YE ; Bin ZHANG ; Chengmin ZHANG ; Jun ZOU ; Qiang ZHOU ; Min ZHAO ; Rui ZHOU ; Xiaojun ZHANG ; Yongfei ZHAO ; Zhongrong ZHANG ; Zehua ZHANG ; Yingze ZHANG
Chinese Journal of Trauma 2025;41(11):1035-1047
For middle-aged and elderly patients with conditions such as spinal fractures and degenerative spinal diseases, spinal internal fixation is a core surgical procedure for reconstructing spinal stability, heavily relying on the biomechanical stability provided by pedicle screw systems. Whereas, these patients are often complicated by osteoporosis that can significantly compromise the stability of the bone-pedicle screw interface, leading to a marked increase in pedicle screw loosening and surgical failure rates. The bone cement-augmented pedicle screw technique, which involves injecting bone cement into the vertebral body or screw trajectory to optimize the mechanical properties of the bone-pedicle screw composite, has been proven to significantly enhance fixation strength and effectively prevent screw-related failures, thereby reducing the incidence of internal fixation failure in high-risk populations undergoing spinal fusion. However, the widespread clinical application of this technique has faced challenges such as inaccurate clinical decision-making (indication and contraindication selection), non-standardized operative practices, and insufficient awareness of complication prevention, resulting in considerable variability in clinical outcomes and even severe complications. To address this, Prof. Luo Fei from First Affiliated Hospital of Army Medical University initiated the project and the Chinese Association Orthopaedic Surgeons organized relevant experts to develop the Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique ( version 2025), based on current evidence. The guidelines put forward 8 recommendations regarding the clinical value, scope of application, and operational standards of the technique, aiming to provide evidence-based medical support and technical standardization for clinical decision-making.
3.Simultaneous determination of ephedrine and pseudoephedrine in human urine using gas chromatography-tandem mass spectrometry
Yuxuan CHEN ; Huimin ZHANG ; Xiaolong ZHANG ; Mengchao WANG ; Kundi ZHAO ; Yinyin DAI ; Jie GU ; Wurita AMIN ; Liqin CHEN
Chinese Journal of Forensic Medicine 2025;40(3):338-342,347
Objective To develop a gas chromatography-tandem mass spectrometry(GC-MS/MS)method for the simultaneous determination of ephedrine and pseudoephedrine in urine.Methods Urine samples containing ephedrine and pseudoephedrine components were extracted with ethyl acetate,centrifuged to collect the supernatant and evaporated to dryness under a nitrogen stream and then derivatized with heptafluorobutyric anhydride 60 μL at 70 ℃ for 30 min,and re-evaporated under nitrogen,and then solubilized with 50 μL of methanol,and then analyzed by GC-MS/MS.Results The method demonstraed excellent linearity for ephedrine(0.05~10 μg/mL,r=0.999 8)and pseudoephedrine(0.02~5 μg/mL,r=0.999 5).Extraction recoveries ranged from 89.4%~95.8%(ephedrine)and 90.3%~93.8%(pseudoephedrine).Limits of detection and quantification of ephedrine and pseudoephedrine were 0.005 μg/mL and 0.01 μg/mL,the intra-day precision and accuracy were less than 5.87%and 9.56%,respectively,and the inter-day precision and accuracy were less than 7.54%and 9.27%,respectively.The stability of ephedrine and pseudoephedrine in urine in 15 d was good under the conditions of room temperature and-20 ℃.Conclusion The GC-MS/MS analytical method for the analysis of ephedrine and pseudoephedrine components in urine established in this study is accurate,stable and sensitive,which can provide data technical support for the forensic toxicological analysis of amphetamine-type drugs or new psychoactive substances in the cathinone group.
4.Impact of Postoperative Reduction Quality on Biomechanics of the Femoral Head Following Internal Fixation of Femoral Neck Fractures
Shixiong ZHANG ; Jianxiong MA ; Bin LU ; Ying WANG ; Aixian TIAN ; Lei SUN ; Zhe HAN ; Jiahui CHEN ; Jing DAI ; Haohao BAI ; Hongzhen JIN ; Jie ZHAO ; Pengfei LI ; Xinlong MA
Journal of Medical Biomechanics 2025;40(5):1144-1149
Objective To investigate the effect of postoperative reduction quality in femoral neck fracture internal fixation on mechanical properties of the femoral head from the perspective of trabecular bone biomechanics.Methods From patients who underwent hip replacement surgery for femoral neck fractures,a total of 26 femoral head slice specimens were obtained.The central axis of the primary compressive trabeculae was defined as the 0° group,with the intersection point of the primary compressive trabeculae and the femoral calcar serving as the center.By rotating the specimens to simulate different reduction angles,the cut femoral head slice specimens were randomly divided into five groups:-10°,-5°,0°,5°,and 10°,representing femoral heads with varying reduction qualities.The specimens were subjected to single compression load tests and fatigue load tests.The load was set from 70 N to 1 400 N,at a frequency of 1 Hz,with 10 000 cycles.Axial stiffness,displacement,and the number of collapse cycles were measured,to compare the biomechanical properties of femoral head specimens under different reduction qualities.Results There were differences in the axial stiffness,displacement,and number of collapse cycles among the femoral head specimens in different groups.Under 800 N load,the axial stiffness of 0° group was significantly greater than that of±10° groups(P<0.05).The axial stiffness of 0° group was also greater than that of the±5° groups,but the differences were not statistically significant(P>0.05).The axial stiffness of±5° groups was greater than that of±10° groups(P<0.05).0° group had a lower displacement than±5° groups and±10° groups.However,the differences in displacement between 0° group and±5° groups were not statistically significant(P>0.05),while the differences between the 0° group and±10° groups were statistically significant(P<0.05).The differences in displacement between±5° groups and±10° groups were also statistically significant(P<0.05).0° group had a significantly higher number of collapse cycles than±10° groups(P<0.05).The number of collapse cycles in 0° group was also higher than that in±5° groups,but the differences were not statistically significant(P>0.05).The number of collapse cycles in±5° groups was significantly higher than that±10° groups(P<0.05).Conclusions The quality of reduction after internal fixation of femoral neck fractures significantly affects the biomechanical properties of the femoral head.This study provides a scientific basis for optimizing treatment and postoperative management,aiming to improve clinical outcomes and patients' quality of life.
5.Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique (version 2025)
Sihao HE ; Junchao XING ; Tongwei CHU ; Zhengqi CHANG ; Xigao CHENG ; Fei DAI ; Xiaobing JIANG ; Jie HAO ; Jiang HU ; Jinghui HUANG ; Tianyong HOU ; Fei LUO ; Bo LIAO ; Changqing LI ; Lei LIU ; Guodong LIU ; Peng LIU ; Sheng LU ; Weishi LI ; Yang LIU ; Zhen LIU ; Wei MEI ; Peifu TANG ; Bing WANG ; Bing WANG ; Ce WANG ; Hongli WANG ; Liang WANG ; Shengru WANG ; Xiaobin WANG ; Yang WANG ; Yingfeng WANG ; Zheng WANG ; Jianzhong XU ; Guoyong YIN ; Haiyang YU ; Qiang YANG ; Zhaoming YE ; Bin ZHANG ; Chengmin ZHANG ; Jun ZOU ; Qiang ZHOU ; Min ZHAO ; Rui ZHOU ; Xiaojun ZHANG ; Yongfei ZHAO ; Zhongrong ZHANG ; Zehua ZHANG ; Yingze ZHANG
Chinese Journal of Trauma 2025;41(11):1035-1047
For middle-aged and elderly patients with conditions such as spinal fractures and degenerative spinal diseases, spinal internal fixation is a core surgical procedure for reconstructing spinal stability, heavily relying on the biomechanical stability provided by pedicle screw systems. Whereas, these patients are often complicated by osteoporosis that can significantly compromise the stability of the bone-pedicle screw interface, leading to a marked increase in pedicle screw loosening and surgical failure rates. The bone cement-augmented pedicle screw technique, which involves injecting bone cement into the vertebral body or screw trajectory to optimize the mechanical properties of the bone-pedicle screw composite, has been proven to significantly enhance fixation strength and effectively prevent screw-related failures, thereby reducing the incidence of internal fixation failure in high-risk populations undergoing spinal fusion. However, the widespread clinical application of this technique has faced challenges such as inaccurate clinical decision-making (indication and contraindication selection), non-standardized operative practices, and insufficient awareness of complication prevention, resulting in considerable variability in clinical outcomes and even severe complications. To address this, Prof. Luo Fei from First Affiliated Hospital of Army Medical University initiated the project and the Chinese Association Orthopaedic Surgeons organized relevant experts to develop the Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique ( version 2025), based on current evidence. The guidelines put forward 8 recommendations regarding the clinical value, scope of application, and operational standards of the technique, aiming to provide evidence-based medical support and technical standardization for clinical decision-making.
6.Simultaneous determination of ephedrine and pseudoephedrine in human urine using gas chromatography-tandem mass spectrometry
Yuxuan CHEN ; Huimin ZHANG ; Xiaolong ZHANG ; Mengchao WANG ; Kundi ZHAO ; Yinyin DAI ; Jie GU ; Wurita AMIN ; Liqin CHEN
Chinese Journal of Forensic Medicine 2025;40(3):338-342,347
Objective To develop a gas chromatography-tandem mass spectrometry(GC-MS/MS)method for the simultaneous determination of ephedrine and pseudoephedrine in urine.Methods Urine samples containing ephedrine and pseudoephedrine components were extracted with ethyl acetate,centrifuged to collect the supernatant and evaporated to dryness under a nitrogen stream and then derivatized with heptafluorobutyric anhydride 60 μL at 70 ℃ for 30 min,and re-evaporated under nitrogen,and then solubilized with 50 μL of methanol,and then analyzed by GC-MS/MS.Results The method demonstraed excellent linearity for ephedrine(0.05~10 μg/mL,r=0.999 8)and pseudoephedrine(0.02~5 μg/mL,r=0.999 5).Extraction recoveries ranged from 89.4%~95.8%(ephedrine)and 90.3%~93.8%(pseudoephedrine).Limits of detection and quantification of ephedrine and pseudoephedrine were 0.005 μg/mL and 0.01 μg/mL,the intra-day precision and accuracy were less than 5.87%and 9.56%,respectively,and the inter-day precision and accuracy were less than 7.54%and 9.27%,respectively.The stability of ephedrine and pseudoephedrine in urine in 15 d was good under the conditions of room temperature and-20 ℃.Conclusion The GC-MS/MS analytical method for the analysis of ephedrine and pseudoephedrine components in urine established in this study is accurate,stable and sensitive,which can provide data technical support for the forensic toxicological analysis of amphetamine-type drugs or new psychoactive substances in the cathinone group.
7.Impact of Postoperative Reduction Quality on Biomechanics of the Femoral Head Following Internal Fixation of Femoral Neck Fractures
Shixiong ZHANG ; Jianxiong MA ; Bin LU ; Ying WANG ; Aixian TIAN ; Lei SUN ; Zhe HAN ; Jiahui CHEN ; Jing DAI ; Haohao BAI ; Hongzhen JIN ; Jie ZHAO ; Pengfei LI ; Xinlong MA
Journal of Medical Biomechanics 2025;40(5):1144-1149
Objective To investigate the effect of postoperative reduction quality in femoral neck fracture internal fixation on mechanical properties of the femoral head from the perspective of trabecular bone biomechanics.Methods From patients who underwent hip replacement surgery for femoral neck fractures,a total of 26 femoral head slice specimens were obtained.The central axis of the primary compressive trabeculae was defined as the 0° group,with the intersection point of the primary compressive trabeculae and the femoral calcar serving as the center.By rotating the specimens to simulate different reduction angles,the cut femoral head slice specimens were randomly divided into five groups:-10°,-5°,0°,5°,and 10°,representing femoral heads with varying reduction qualities.The specimens were subjected to single compression load tests and fatigue load tests.The load was set from 70 N to 1 400 N,at a frequency of 1 Hz,with 10 000 cycles.Axial stiffness,displacement,and the number of collapse cycles were measured,to compare the biomechanical properties of femoral head specimens under different reduction qualities.Results There were differences in the axial stiffness,displacement,and number of collapse cycles among the femoral head specimens in different groups.Under 800 N load,the axial stiffness of 0° group was significantly greater than that of±10° groups(P<0.05).The axial stiffness of 0° group was also greater than that of the±5° groups,but the differences were not statistically significant(P>0.05).The axial stiffness of±5° groups was greater than that of±10° groups(P<0.05).0° group had a lower displacement than±5° groups and±10° groups.However,the differences in displacement between 0° group and±5° groups were not statistically significant(P>0.05),while the differences between the 0° group and±10° groups were statistically significant(P<0.05).The differences in displacement between±5° groups and±10° groups were also statistically significant(P<0.05).0° group had a significantly higher number of collapse cycles than±10° groups(P<0.05).The number of collapse cycles in 0° group was also higher than that in±5° groups,but the differences were not statistically significant(P>0.05).The number of collapse cycles in±5° groups was significantly higher than that±10° groups(P<0.05).Conclusions The quality of reduction after internal fixation of femoral neck fractures significantly affects the biomechanical properties of the femoral head.This study provides a scientific basis for optimizing treatment and postoperative management,aiming to improve clinical outcomes and patients' quality of life.
8.Quality evaluation for Beidougen Formula Granules
Gui-Yun CAO ; Xue-Song ZHUANG ; Bo NING ; Yong-Qiang LIN ; Dai-Jie WANG ; Wei-Liang CUI ; Hong-Chao LIU ; Xiao-Di DONG ; Meng-Meng HUANG ; Zhao-Qing MENG
Chinese Traditional Patent Medicine 2024;46(3):717-723
AIM To evaluate the quality of Beidougen Formula Granules.METHODS Fifteen batches of standard decoctions and three batches of formula granules were prepared,after which paste rate and contents,transfer rates of magnoflorine,daurisoline,dauricine were determined.HPLC specific chromatograms were established,and cluster analysis was adopted in chemical pattern recognition.RESULTS For three batches of formula granules,the paste rates were 15.1%-16.6%,the contents of magnoflorine,daurisoline,dauricine were 18.93-19.39,9.42-9.60,6.79-6.85 mg/g with the transfer rates of 34.42%-35.25%,43.81%-44.65%,27.27%-27.51%from decoction pieces to formula granules,respectively,and there were seven characteristic peaks in the specific chromatograms with the similarities of more than 0.95,which demonstrated good consistence with those of standard decoctions and accorded with related limit requirements.Fifteen batches of standard decoctions were clustered into two types,and the medicinal materials produced from Jilin,Hebei,Shangdong could be used for the preparation of formula granules.CONCLUSION This reasonable and reliable method can provide references for the quality control and clinical application of Beidougen Formula Granules.
9.Optimization of water extraction technology of Xiangqin jiere granules by orthogonal design based on G1-entropy weight compared with BP neural network
Bingduo CHENG ; Liqin LUO ; Yuanzeng LI ; Jie JIANG ; Yiying CHEN ; Ji ZHAO ; Rui XUE ; Yunshu MA
China Pharmacy 2024;35(1):27-32
OBJECTIVE Optimizing the water extraction technology of Xiangqin jiere granules. METHODS The orthogonal test of 3 factors and 3 levels was designed, and comprehensive scoring was conducted for the above indexes by using G1-entropy weight to obtain the optimized water extraction technology of Xiangqin jiere granules with water addition ratio, extraction time and extraction times as factors, using the contents of forsythoside A, baicalin, phillyrin, oroxylin A-7-O-β-D-glycoside, wogonoside, baicalein and wogonin, and extraction rate as evaluation indexes. BP neural network modeling was used to optimize the network model and water extraction process using the results of 9 groups of orthogonal tests as test and training data, the water addition multiple, decocting time and extraction times as input nodes, and the comprehensive score as output nodes. Then the two analysis methods were compared by verification test to find the best water extraction process parameters. RESULTS The water extraction technology optimized by the orthogonal test was 8-fold water, extracting 3 times, extracting for 1 h each time. Comprehensive score was 96.84 (RSD=0.90%). The optimal water extraction technology obtained by BP neural network modeling included 12-fold water, extracting 4 times, extracting for 0.5 h each time. The comprehensive score was 92.72 (RSD=0.77%), which was slightly lower than that of the orthogonal test. CONCLUSIONS The water extraction technology of Xiangqin jiere granules is optimized successfully in the study, which includes adding 8-fold water, extracting 3 times, and extracting for 1 hour each time.
10.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.

Result Analysis
Print
Save
E-mail