1.Development and usability evaluation of a web-based healthy eating practice questionnaire for Korean preschool children: a child–parent dyad approach
Young-Hee HAN ; Dawon PARK ; Dahyeon KIM ; Saerom SHIN ; Eun Yeol WOO ; Hye-Kyung PARK ; Taisun HYUN
Nutrition Research and Practice 2026;20(1):132-144
BACKGROUND/OBJECTIVES:
The illustrated Healthy Eating Practice Questionnaire (HEPQ) was previously developed to assess food preferences, eating behaviors, hand/oral hygiene practices, and nutrition knowledge among Korean preschool children. Nevertheless, the lack of an integrated scoring system has limited its interpretability. This study developed a scoring system and a web-based platform with tailored feedback using a child-parent dyad approach.
SUBJECTS/METHODS:
The development process consisted of 5 phases: 1) questionnaire preparation for online use, 2) formulation of the scoring system, 3) determination of the cut-off values for three levels of healthy eating practices based on a child-parent survey, 4) technical development of the online platform, and 5) usability evaluation. A scoring system was established by standardizing the domain scores to a 100-point scale. One hundred child– parent pairs participated in the survey to calculate the Healthy Eating Practice Score (HEPS) and determine cut-off values for the HEPS levels. The validity of the cut-off values was examined by a comparison with the Nutrition Quotient for Preschoolers (NQ-P). A web-based platform was developed, and 47 child–parent pairs were used to assess its usability.
RESULTS:
Significant positive correlations were observed between child and parent HEPS across all domains. The HEPS-based classification showed good discriminative ability because higher HEPS levels were consistently associated with higher NQ-P scores in children and parents. The web-based HEPQ was easy to use and understand, and almost all participants (97.9% of children and 93.6% of parents) reported no difficulties using the platform.
CONCLUSION
The web-based HEPQ platform with an integrated scoring system provides a valid, user-friendly tool for assessing and interpreting healthy eating practices in preschool children. This platform supports parental engagement in children’s healthy eating practices and provides a practical tool for evaluating the effectiveness of nutrition education in early childcare settings.
2.Immunomodulatory Effects of Human Breast Milk-Derived Exosomes on Myeloid Cells and Chondrocytes
Dahyeon KWON ; Ji Yoon YOO ; Kang-Bin DAN ; Ki-Uk KIM ; Ji-Yun LEE ; Hyeyoung MIN
Biomolecules & Therapeutics 2026;34(3):689-696
Human breast milk (HBM) is an ideal nutritional source for the growth and development of infants. In addition, HBM contains hormones, growth factors, microRNAs and exosomes that perform various physiological functions. This study investigates the immunomodulatory effects of HBM-derived exosomes on myeloid cells and chondrocytes, and implications for juvenile idiopathic arthritis. HBM-derived exosomes were isolated and characterized using nanoparticle track analyzer and Western blotting. The HBM-derived exosomes treatment decreased the expression of inflammatory mediators and proinflammatory cytokines in mouse peritoneal macrophages upon lipopolysaccharide stimulation. Flow cytometry analysis of bone marrow-derived macrophages indicated that exosomes promoted M2 polarization, as evidenced by a decrease in cells expressing CD80 (M1 marker) and a concurrent increase in cells expressing M2 marker CD206. In addition, exosome treatment attenuated the mitogen-activated protein kinase signaling pathway by reducing the phosphorylation of extracellular signal-regulated kinase, c-Jun N-terminal kinase, p38 mitogen-activated protein kinase, and IκB-α, thereby reducing the expression of inducible nitric oxide synthase, cyclooxygenase-2, metalloprotease (MMP)-1, MMP-3, and MMP-13 in SW1353 chondrocytes following IL-1β stimulation. These findings suggest that HBM-derived exosomes promote macrophage polarization toward an anti-inflammatory M2 phenotype and exert significant immunomodulatory effects.
3.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
Purpose:
Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS.
Materials and Methods:
Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05.
Results:
Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS.
Conclusion
A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS.
4.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
Purpose:
Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS.
Materials and Methods:
Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05.
Results:
Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS.
Conclusion
A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS.
5.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
Purpose:
Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS.
Materials and Methods:
Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05.
Results:
Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS.
Conclusion
A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS.
6.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
Purpose:
Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS.
Materials and Methods:
Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05.
Results:
Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS.
Conclusion
A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS.
7.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
Purpose:
Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS.
Materials and Methods:
Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05.
Results:
Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS.
Conclusion
A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS.
8.Development and validation of an illustrated questionnaire on healthy eating practices among Korean preschool children
Dawon PARK ; Bo-Jeong GONG ; Dahyeon KIM ; Young-Hee HAN ; Saerom SHIN ; Eun Yeol WOO ; Hye-Kyung PARK ; Taisun HYUN
Nutrition Research and Practice 2025;19(6):985-1001
BACKGROUND/OBJECTIVES:
An illustrated questionnaire, the Healthy Eating Practice Questionnaire (HEPQ), was developed and validated to assess healthy eating practices among Korean preschool children.
SUBJECTS/METHODS:
The development process consisted of 4 phases: (1) item generation based on a literature review and focus group interviews, (2) item refinement through expert consultation, (3) illustration design, and (4) validation. One hundred and eighty-seven child–parent pairs and 24 teachers participated in the validation study. The reliability was examined using test–retest analysis, and the validity was assessed by comparing the children’s self-reports with those of their parents and teachers. The level of agreement was determined using the percentage agreement, kappa statistics, and intraclass correlation coefficient (ICC).
RESULTS:
The final 30-item questionnaire consisted of 4 domains: food preferences, eating behaviors, hand/oral hygiene practices, and nutrition knowledge. Most items showed a percentage agreement above 60% and kappa coefficients exceeding 0.5 in test–retest analysis, indicating acceptable consistency. The child–caregiver agreement was moderate to substantial, with kappa values generally above 0.4. The domain-level ICCs indicated good reliability (ICC = 0.49–0.83) and validity (ICC = 0.33–0.77) across all domains and subgroups.The comparisons by age showed that 4-yr-olds provided valid and reliable responses comparable to 5-yr-olds. The parents and teachers confirmed that the illustrated format was easy for the children to understand and complete independently.
CONCLUSION
The HEPQ showed satisfactory reliability and validity for assessing healthy eating practices among preschool children. The illustrated format enhances comprehension and engagement, supporting its applicability for research and nutrition education in daycare settings.
9.Food and nutrient intake in pregnant women with singletons or multiples and post-delivery changes in intake in Korea: an observational study
Cheawon LEE ; Dahyeon KIM ; Yoon Ha KIM ; Myeong Gyun CHOI ; Jong Woon KIM ; Clara Yongjoo PARK
Korean Journal of Community Nutrition 2025;30(1):1-15
Objectives:
Nutrient intake during pregnancy and lactation is crucial for the health of both mother and offspring. Diet and nutrient metabolism potentially vary according to ethnicity and fetal number; nevertheless, recent studies validating this are inadequate. Furthermore, few studies have tracked changes in intake after delivery. We compared the food and nutrient intakes between pregnant women in Korea carrying singletons and multiples during late pregnancy and assessed their changes through postpartum.
Methods:
Ninety-eight pregnant women were recruited from Chonnam National University Hospital between January 2019 and December 2023, and 48 responded to follow-up. Third trimester and postpartum intake were assessed via food frequency questionnaires and supplement questionnaires. Student’s t-test, Mann–Whitney U test, chi-square test, paired t-test or Wilcoxon signed-rank test was performed and adjustments were made for covariates.
Results:
Nutrient intake was generally adequate relative to the Dietary Reference Intakes for Koreans, with no differences between singleton- and multiple-pregnancy women. Sixty-six of 98 (67%) pregnant women consumed meat, fish, vegetables, and fruit daily. Dairy intake was low, while the mean iron intake during pregnancy reached 54.2 ± 34.0 mg/d, exceeding the tolerable upper intake level, mainly owing to supplements. Postpartum fruit and vitamin C intake decreased, with no significant differences between breastfeeding and non-breastfeeding women.
Conclusion
Dietary intake did not significantly differ between Korean singleton- and multiple-pregnancy women. Dairy intake was low and iron intake was excessive. Fruit intake decreased after delivery; however, difference in dietary intake according to breastfeeding status was minimal. Nutritional education may be necessary to promote a balanced diet in pregnant and postpartum women. Trial Registration: Clinical Research Information Service Identifier KCT0005118.
10.Effect of the Application of Vibration Foam Rollers Before and After Resistance Exercise on Blood Muscle Injury Markers and Muscle Stiffness
Dahyeon YE ; Dohyun KIM ; Eunsook KIM ; Younghyun BYUN ; Sungjin YOON
Korean Journal of Health Promotion 2024;24(3):93-100
Background:
This study aimed to compare the effects of applying a vibrating foam roller before resistance exercise versus after resistance exercise on changes in serum muscle damage markers, muscle stiffness, and range of motion. This study also aimed to provide foundational data for optimizing the timing of vibrating foam roller application to enhance recovery after resistance exercise in practical settings.
Methods:
Twelve healthy adult males were recruited as participants. Each participant was subjected to three interventions in a random order with a washout period of at least 5 days: vibration foam rolling before resistance exercise, vibration foam rolling after resistance exercise, and resistance exercise without vibration foam rolling. Blood creatine kinase, knee flexion range of motion, and muscle stiffness were measured before, immediately after, 24 hours after, and 48 hours after exercise and foam rolling protocols.
Results:
Creatine kinase levels in vibration foam rolling after resistance exercise were significantly lower than those in vibration foam rolling before resistance exercise at 24 and 48 hours post-exercise. Muscle stiffness was significantly lower immediately and 24 hours post-exercise in vibration foam rolling after resistance exercise than in vibration foam rolling before resistance exercise and resistance exercise without vibration foam rolling. Knee flexion range of motion was significantly lower in resistance exercise without vibration foam rolling than in vibration foam rolling after resistance exercise at 24 and 48 hours post-exercise.
Conclusions
The application of vibration foam rolling after resistance exercise was more effective than that before exercise in decreasing muscle damage markers, reducing muscle stiffness, and improving the range of motion.

Result Analysis
Print
Save
E-mail