1.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
2.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
3.Uncorrectable hypoxemia due to large pulmonary arteriovenous malformation in a patient with myocardial infarction: a case report
Journal of Yeungnam Medical Science 2025;42(1):12-
Persistent hypoxemia following myocardial infarction can be challenging to manage and often requires considering uncommon etiologies such as extracardiac shunts. This case report describes a 78-year-old man with persistent hypoxemia post-myocardial infarction, which was ultimately attributed to a large pulmonary arteriovenous malformation (AVM). The patient presented with cardiogenic shock and underwent successful revascularization. Despite clinical improvement, the hypoxemia persisted, prompting further evaluation. Bedside saline contrast echocardiography and computed tomography confirmed the presence of a large pulmonary AVM, explaining the uncorrectable hypoxemia. This case underscores the importance of considering extracardiac shunts in patients with refractory hypoxemia and illustrates the utility of bedside imaging in such situations.
4.Complete or incomplete revascularization in patients with left main culprit lesion acute myocardial infarction with multivessel disease: a retrospective observational study
Sun Oh KIM ; Hong-Ju KIM ; Jong-Il PARK ; Kang-Un CHOI ; Jong-Ho NAM ; Chan-Hee LEE ; Jang-Won SON ; Jong-Seon PARK ; Sung-Ho HER ; Ki-Yuk CHANG ; Tae-Hoon AHN ; Myung-Ho JEONG ; Seung-Woon RHA ; Hyo-Soo KIM ; Hyeon-Cheol GWON ; In-Whan SEONG ; Kyung-Kuk HWANG ; Seung-Ho HUR ; Kwang-Soo CHA ; Seok-Kyu OH ; Jei-Keon CHAE ; Ung KIM
Journal of Yeungnam Medical Science 2025;42(1):18-
Background:
Complete revascularization has demonstrated better outcomes in patients with acute myocardial infarction (AMI) and multivessel disease. However, in the case of left main (LM) culprit lesion AMI with multivessel disease, there is limited evidence to suggest that complete revascularization is better.
Methods:
We reviewed 16,831 patients in the Korea Acute Myocardial Infarction Registry who were treated from July 2016 to June 2020, and 399 patients were enrolled with LM culprit lesion AMI treated with percutaneous coronary intervention. We categorized the patients as those treated with complete revascularization (n=295) or incomplete revascularization (n=104). The study endpoint was major adverse cardiac and cerebrovascular events (MACCE), a composite of all-cause death, myocardial infarction, ischemia-driven revascularization, stent thrombosis, and stroke. We performed propensity score matching (PSM) and analyzed the incidence of MACCE at 1 year.
Results:
After PSM, the two groups were well balanced. There was no significant difference between the two groups in MACCE at 1 year (12.1% vs. 15.2%; hazard ratio, 1.28; 95% confidence interval, 0.60–2.74; p=0.524) after PSM. The components of MACCE and major bleeding were also not significantly different.
Conclusion
There was no significant difference in clinical outcomes between the groups treated with complete or incomplete revascularization for LM culprit lesion AMI with multivessel disease.
5.Efficacy of transversus abdominis plane block in postoperative pain management of laparoscopic totally extraperitoneal inguinal hernia repair: a propensity score-matched analysis
Gimin LEE ; Sanghyuk MOON ; Nagyeong KIM ; Daeun BAEK ; Nak-Hoon SON ; Kyeong Hwan SEO ; Eunyoung JUNG
Annals of Surgical Treatment and Research 2025;108(1):57-63
Purpose:
Transversus abdominis plane (TAP) block is a promising technique for postoperative pain control. In this study, we aimed to evaluate the efficacy of the TAP block in managing postoperative pain after laparoscopic totally extraperitoneal (TEP) inguinal hernia repair.
Methods:
In this retrospective study, medical records of patients who had received ultrasonography-guided TAP blocks after surgery from January 2019 to August 2023 were reviewed and compared with those of patients who had not received. Propensity score matching was controlled for age as a confounder. Postoperative pain levels were measured using the numeric rating scale (NRS).
Results:
After matching, 95 patients were included in each group. The TAP block group (2.7 vs. 4.0, P < 0.001) had significantly lower NRS scores immediately and early postoperative pain than the control group (1.9 vs. 2.5, P < 0.001). However, there was no significant difference between the 2 groups in terms of postoperative complications (P > 0.05).
Conclusion
TAP block is effective and safe for managing immediate and early postoperative pain in laparoscopic TEP inguinal hernia repair and does not increase the risk of complications.
6.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
7.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
8.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
9.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
10.Uncorrectable hypoxemia due to large pulmonary arteriovenous malformation in a patient with myocardial infarction: a case report
Journal of Yeungnam Medical Science 2025;42(1):12-
Persistent hypoxemia following myocardial infarction can be challenging to manage and often requires considering uncommon etiologies such as extracardiac shunts. This case report describes a 78-year-old man with persistent hypoxemia post-myocardial infarction, which was ultimately attributed to a large pulmonary arteriovenous malformation (AVM). The patient presented with cardiogenic shock and underwent successful revascularization. Despite clinical improvement, the hypoxemia persisted, prompting further evaluation. Bedside saline contrast echocardiography and computed tomography confirmed the presence of a large pulmonary AVM, explaining the uncorrectable hypoxemia. This case underscores the importance of considering extracardiac shunts in patients with refractory hypoxemia and illustrates the utility of bedside imaging in such situations.

Result Analysis
Print
Save
E-mail