1.Astragaloside IV Alleviates Podocyte Injury in Diabetic Nephropathy through Regulating IRE-1α/NF-κ B/NLRP3 Pathway.
Da-Lin SUN ; Zi-Yi GUO ; Wen-Yuan LIU ; Lin ZHANG ; Zi-Yuan ZHANG ; Ya-Ling HU ; Su-Fen LI ; Ming-Yu ZHANG ; Guang ZHANG ; Jin-Jing WANG ; Jing-Ai FANG
Chinese journal of integrative medicine 2025;31(5):422-433
OBJECTIVE:
To investigate the effects of astragaloside IV (AS-IV) on podocyte injury of diabetic nephropathy (DN) and reveal its potential mechanism.
METHODS:
In in vitro experiment, podocytes were divided into 4 groups, normal, high glucose (HG), inositol-requiring enzyme 1 (IRE-1) α activator (HG+thapsigargin 1 µmol/L), and IRE-1α inhibitor (HG+STF-083010, 20 µmol/L) groups. Additionally, podocytes were divided into 4 groups, including normal, HG, AS-IV (HG+AS-IV 20 µmol/L), and IRE-1α inhibitor (HG+STF-083010, 20 µmol/L) groups, respectively. After 24 h treatment, the morphology of podocytes and endoplasmic reticulum (ER) was observed by electron microscopy. The expressions of glucose-regulated protein 78 (GRP78) and IRE-1α were detected by cellular immunofluorescence. In in vivo experiment, DN rat model was established via a consecutive 3-day intraperitoneal streptozotocin (STZ) injections. A total of 40 rats were assigned into the normal, DN, AS-IV [AS-IV 40 mg/(kg·d)], and IRE-1α inhibitor [STF-083010, 10 mg/(kg·d)] groups (n=10), respectively. The general condition, 24-h urine volume, random blood glucose, urinary protein excretion rate (UAER), urea nitrogen (BUN), and serum creatinine (SCr) levels of rats were measured after 8 weeks of intervention. Pathological changes in the renal tissue were observed by hematoxylin and eosin (HE) staining. Quantitative reverse transcription-polymerase chain reaction (RT-PCR) and Western blot were used to detect the expressions of GRP78, IRE-1α, nuclear factor kappa Bp65 (NF-κBp65), interleukin (IL)-1β, NLR family pyrin domain containing 3 (NLRP3), caspase-1, gasdermin D-N (GSDMD-N), and nephrin at the mRNA and protein levels in vivo and in vitro, respectively.
RESULTS:
Cytoplasmic vacuolation and ER swelling were observed in the HG and IRE-1α activator groups. Podocyte morphology and ER expansion were improved in AS-IV and IRE-1α inhibitor groups compared with HG group. Cellular immunofluorescence showed that compared with the normal group, the fluorescence intensity of GRP78 and IRE-1α in the HG and IRE-1α activator groups were significantly increased whereas decreased in AS-IV and IRE-1α inhibitor groups (P<0.05). Compared with the normal group, the mRNA and protein expressions of GRP78, IRE-1α, NF-κ Bp65, IL-1β, NLRP3, caspase-1 and GSDMD-N in the HG group was increased (P<0.05). Compared with HG group, the expression of above indices was decreased in the AS-IV and IRE-1α inhibitor groups, and the expression in the IRE-1α activator group was increased (P<0.05). The expression of nephrin was decreased in the HG group, and increased in AS-IV and IRE-1α inhibitor groups (P<0.05). The in vivo experiment results revealed that compared to the normal group, the levels of blood glucose, triglyceride, total cholesterol, BUN, blood creatinine and urinary protein in the DN group were higher (P<0.05). Compared with DN group, the above indices in AS-IV and IRE-1α inhibitor groups were decreased (P<0.05). HE staining revealed glomerular hypertrophy, mesangial widening and mesangial cell proliferation in the renal tissue of the DN group. Compared with the DN group, the above pathological changes in renal tissue of AS-IV and IRE-1α inhibitor groups were alleviated. Quantitative RT-PCR and Western blot results of GRP78, IRE-1α, NF-κ Bp65, IL-1β, NLRP3, caspase-1 and GSDMD-N were consistent with immunofluorescence analysis.
CONCLUSION
AS-IV could reduce ERS and inflammation, improve podocyte pyroptosis, thus exerting a podocyte-protective effect in DN, through regulating IRE-1α/NF-κ B/NLRP3 signaling pathway.
Podocytes/metabolism*
;
Animals
;
Diabetic Nephropathies/metabolism*
;
Saponins/therapeutic use*
;
Triterpenes/therapeutic use*
;
Signal Transduction/drug effects*
;
NF-kappa B/metabolism*
;
Protein Serine-Threonine Kinases/metabolism*
;
Male
;
Rats, Sprague-Dawley
;
NLR Family, Pyrin Domain-Containing 3 Protein/metabolism*
;
Endoribonucleases/metabolism*
;
Endoplasmic Reticulum Chaperone BiP
;
Rats
;
Diabetes Mellitus, Experimental/complications*
;
Endoplasmic Reticulum/metabolism*
;
Multienzyme Complexes
2.Reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur with a 3D printed modular supporting prosthesis
Minxun LU ; Linyun TAN ; Xin HU ; Zihan PENG ; Zhuangzhuang LI ; Wacili DA ; Xuanhong HE ; Weiyi WANG ; Yitian WANG ; Yi LUO ; Chongqi TU ; Li MIN
Chinese Journal of Orthopaedics 2025;45(10):686-692
Objective:To observe the early clinical efficacy of 3D-printed modular supporting prosthesis for reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur.Methods:From May 2018 to July 2023, a total of 9 patients with giant cell tumor of the distal femur were treated with 3D-printed modular supporting prosthesis to reconstruct lacunar bone defects in the Department of Orthopedics, West China Hospital, Sichuan University. There were 4 males and 5 females, aged 30.8±6.1 years (range, 24-44 years), 5 cases on the left side, 4 cases on the right side, 2 cases of Campanacci grade I, 7 cases of Campanacci grade II. The anteroposterior and lateral X-ray films and T-SMART tomosynthesis imaging of the knee joint were taken to observe the bone graft healing and osseointegration after operation. Musculoskeletal Tumor Society (MSTS)-93 was used to evaluate knee function, and visual analogue scale (VAS) was used to evaluate knee pain.Results:All patients were successfully operated and followed up for an average of 30.8±7.5 months (range, 18-42 months). The operation time was 124.2±23.6 min, and the intraoperative blood loss was 105.6±17.4 ml. All autografts showed bony union at the graft-host junction, and the healing time was 3.3±0.4 months (range, 3.0-4.0 months). At 6 months after surgery, T-SMART tomosynthesis imaging showed that the gap between the prosthesis-bone interface was less than 1 mm in all patients. At the last follow-up, the thickness of residual subchondral bone was 5.7±1.3 mm, which was greater than that before operation 2.2±0.8 mm, and the difference was statistically significant ( t=10.823, P<0.001). At the last follow-up, the score of MSTS-93 was 26.7±2.4, which was higher than that before operation 18.8±3.7, and the difference was statistically significant ( t=5.367, P<0.001). At the last follow-up, the range of motion of the knee joint was 122.8°±9.1°, which was higher than that before operation 108.3°±6.1°, and the difference was statistically significant ( t=3.970, P<0.001). All patients were able to walk normally, go up and down stairs and other daily activities, and 7 patients were able to complete squats. At the last follow-up, there was no local tumor recurrence, distant metastasis, death, joint infection, pain (VAS score was 0), delayed wound healing, joint degeneration, prosthesis loosening or articular surface collapse. Conclusion:Reconstruction of lacunar bone defect caused by giant cell tumor of distal femur with 3D-printed modular supporting prosthesis can effectively improve knee joint function and osseointegration, and the short-term clinical results are satisfactory.
3.Study on the effectiveness and safety of a novel intravascular shock wave balloon for pre-treatment of severe coronary artery calcification lesions
Rui-tao ZHANG ; Zhen-yu TIAN ; Yong ZENG ; Guo-sheng FU ; Li XU ; Jian LIU ; Jian-ping LI ; Zhi-hui ZHANG ; Xin-qun HU ; Xiang CHENG ; Wen LU ; Ming CUI ; Yi-da TANG
Chinese Journal of Interventional Cardiology 2025;33(2):61-70
Objective To evaluate the efficacy and safety of a novel intravascular lithotripsy(IVL)balloon—Vesscrack shockwave balloon—for vascular preparation before stent implantation in patients with severe coronary artery calcification(CAC).Methods This was a prospective,single-arm,multicenter study conducted in China from June 2022 to October 2022.Patients with severe CAC were treated with the Vesscrack shockwave balloon for lesion preparation,followed by drug-eluting stent(DES)implantation.Of these,33 patients underwent optical coherence tomography(OCT).The primary endpoint was procedural success,defined as successful stent implantation with residual stenosis≤30%and the absence of in-hospital major adverse events,including cardiac death,target vessel-related myocardial infarction,or target lesion revascularization.Results A total of 170 patients[mean age:(65.9±7.9)years,116 males]were enrolled.After treatment with IVL and DES,the minimum lumen diameter increased significantly compared to baseline[(2.34±0.40)mm vs.(0.95±0.33)mm,P<0.001],the degree of stenosis was significantly reduced[(13.24±6.60)%vs.(65.18±10.59)%,P<0.001].Procedural success was achieved in 100%of cases,and device success was 98.8%.The 30-day patient-related cardiovascular clinical composite endpoint(POCE)rate was 0.0,with no target lesion failure,no confirmed or potential thrombotic events were observed.The shockwave energy generator demonstrated excellent stability and ease of use.Among the 33 patients assessed with OCT,after IVL intervention,the maximum calcified area of the lumen[(3.51±1.51)mm2 vs.(2.85±1.80)mm2,P<0.001],and the minimum lumen area within the target lesion[(3.08±1.04)mm2 vs.(2.02±0.75)mm2,P<0.001],and after DES intervention,the luminal area of the largest calcified site[(6.59±1.64)mm2 vs.(2.85±1.80)mm2,P<0.001]and the minimum luminal area within the target lesion[(6.19±1.45)mm2 vs.(2.02±0.75)mm2,P<0.001]were significantly increased,and the differences were statistically significant.Conclusions The Vesscrack shockwave balloon is effective and safe for vascular preparation in patients with severe CAC prior to stent implantation.It achieves significant calcified plaque modification,high procedural success rates,and minimal complications.
4.Reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur with a 3D printed modular supporting prosthesis
Minxun LU ; Linyun TAN ; Xin HU ; Zihan PENG ; Zhuangzhuang LI ; Wacili DA ; Xuanhong HE ; Weiyi WANG ; Yitian WANG ; Yi LUO ; Chongqi TU ; Li MIN
Chinese Journal of Orthopaedics 2025;45(10):686-692
Objective:To observe the early clinical efficacy of 3D-printed modular supporting prosthesis for reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur.Methods:From May 2018 to July 2023, a total of 9 patients with giant cell tumor of the distal femur were treated with 3D-printed modular supporting prosthesis to reconstruct lacunar bone defects in the Department of Orthopedics, West China Hospital, Sichuan University. There were 4 males and 5 females, aged 30.8±6.1 years (range, 24-44 years), 5 cases on the left side, 4 cases on the right side, 2 cases of Campanacci grade I, 7 cases of Campanacci grade II. The anteroposterior and lateral X-ray films and T-SMART tomosynthesis imaging of the knee joint were taken to observe the bone graft healing and osseointegration after operation. Musculoskeletal Tumor Society (MSTS)-93 was used to evaluate knee function, and visual analogue scale (VAS) was used to evaluate knee pain.Results:All patients were successfully operated and followed up for an average of 30.8±7.5 months (range, 18-42 months). The operation time was 124.2±23.6 min, and the intraoperative blood loss was 105.6±17.4 ml. All autografts showed bony union at the graft-host junction, and the healing time was 3.3±0.4 months (range, 3.0-4.0 months). At 6 months after surgery, T-SMART tomosynthesis imaging showed that the gap between the prosthesis-bone interface was less than 1 mm in all patients. At the last follow-up, the thickness of residual subchondral bone was 5.7±1.3 mm, which was greater than that before operation 2.2±0.8 mm, and the difference was statistically significant ( t=10.823, P<0.001). At the last follow-up, the score of MSTS-93 was 26.7±2.4, which was higher than that before operation 18.8±3.7, and the difference was statistically significant ( t=5.367, P<0.001). At the last follow-up, the range of motion of the knee joint was 122.8°±9.1°, which was higher than that before operation 108.3°±6.1°, and the difference was statistically significant ( t=3.970, P<0.001). All patients were able to walk normally, go up and down stairs and other daily activities, and 7 patients were able to complete squats. At the last follow-up, there was no local tumor recurrence, distant metastasis, death, joint infection, pain (VAS score was 0), delayed wound healing, joint degeneration, prosthesis loosening or articular surface collapse. Conclusion:Reconstruction of lacunar bone defect caused by giant cell tumor of distal femur with 3D-printed modular supporting prosthesis can effectively improve knee joint function and osseointegration, and the short-term clinical results are satisfactory.
5.Study on the effectiveness and safety of a novel intravascular shock wave balloon for pre-treatment of severe coronary artery calcification lesions
Rui-tao ZHANG ; Zhen-yu TIAN ; Yong ZENG ; Guo-sheng FU ; Li XU ; Jian LIU ; Jian-ping LI ; Zhi-hui ZHANG ; Xin-qun HU ; Xiang CHENG ; Wen LU ; Ming CUI ; Yi-da TANG
Chinese Journal of Interventional Cardiology 2025;33(2):61-70
Objective To evaluate the efficacy and safety of a novel intravascular lithotripsy(IVL)balloon—Vesscrack shockwave balloon—for vascular preparation before stent implantation in patients with severe coronary artery calcification(CAC).Methods This was a prospective,single-arm,multicenter study conducted in China from June 2022 to October 2022.Patients with severe CAC were treated with the Vesscrack shockwave balloon for lesion preparation,followed by drug-eluting stent(DES)implantation.Of these,33 patients underwent optical coherence tomography(OCT).The primary endpoint was procedural success,defined as successful stent implantation with residual stenosis≤30%and the absence of in-hospital major adverse events,including cardiac death,target vessel-related myocardial infarction,or target lesion revascularization.Results A total of 170 patients[mean age:(65.9±7.9)years,116 males]were enrolled.After treatment with IVL and DES,the minimum lumen diameter increased significantly compared to baseline[(2.34±0.40)mm vs.(0.95±0.33)mm,P<0.001],the degree of stenosis was significantly reduced[(13.24±6.60)%vs.(65.18±10.59)%,P<0.001].Procedural success was achieved in 100%of cases,and device success was 98.8%.The 30-day patient-related cardiovascular clinical composite endpoint(POCE)rate was 0.0,with no target lesion failure,no confirmed or potential thrombotic events were observed.The shockwave energy generator demonstrated excellent stability and ease of use.Among the 33 patients assessed with OCT,after IVL intervention,the maximum calcified area of the lumen[(3.51±1.51)mm2 vs.(2.85±1.80)mm2,P<0.001],and the minimum lumen area within the target lesion[(3.08±1.04)mm2 vs.(2.02±0.75)mm2,P<0.001],and after DES intervention,the luminal area of the largest calcified site[(6.59±1.64)mm2 vs.(2.85±1.80)mm2,P<0.001]and the minimum luminal area within the target lesion[(6.19±1.45)mm2 vs.(2.02±0.75)mm2,P<0.001]were significantly increased,and the differences were statistically significant.Conclusions The Vesscrack shockwave balloon is effective and safe for vascular preparation in patients with severe CAC prior to stent implantation.It achieves significant calcified plaque modification,high procedural success rates,and minimal complications.
6.Dosimetric effect of calculation grid size on stereotactic body radiation therapy of lung cancer in helical tomotherapy planning system
Xia-Yu HANG ; Wan-Rong JIANG ; Yi-Kun LI ; Jun HU ; Yan ZHANG ; Ruo-Qi CAO ; Nan XU ; Lei WANG ; Jin-Da ZHOU ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(2):52-57
Objective To investigate the dosimetric effects of different calculation grid size(CGS)in helical tomotherapy(HT)planning system on stereotactic body radiation therapy(SBRT)for non-small cell lung cancer(NSCLC).Methods Nine NSCLC patients receiving radiation therapy for the first time at some hospital from March 2019 to December 2022 were selected as the subjects.SBRT planning was carried out through the HT system with three different CGS plans(Fine,Normal,and Coarse)and the same pitch,modulation factor(MF)and optimization conditions,and the target area indexes of the three CGS plans were compared including conformity index(CI),homogeneity index(HI),dosimetric parameters of the organ at risk(OAR),point dose verification pass rate,treatment time,number of monitor units and Sinograms.SPSS 22.0 was used for statistical analysis.Results For target area HI,there weres significant differences between CGS Fine plan and Coarse plan and between CGS Normal plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan(P>0.05).For target area CI,there were significant differences between CGS Fine plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan and between CGS Normal plan and Coarse plan(P>0.05).For OAR dosimetric parameters,CGS Fine plan and Coarse plan had significant differences in heart Dmax and Dmean,esophageal Dmax and Dmean,V5,V20,V30 and Dmean of the whole lung and affected lung,V5 and Dmax of the affected lung and heart V10 and V30(P<0.05),CGS Normal plan and Coarse plan had obvious differences in esophageal Dmax(P<0.05),and the remained dosimetric parameters were not statistically significant(P>0.05).Fine,Normal and Coarse plans had the point dose verifica-tion pass rates being 0.96%,1.50%and 1.77%,respectively.In terms of treatment time and number of monitor units,there were significant differences between Fine plan and Coarse plan(P<0.05)while no statistical differences were found between Fine and Normal plans and between Normal and Coarse plans(P>0.05).Sinograms analyses showed Fine plan had evenly distributed segment color gradient,Coarse plan had areas of very dark and very light color gradients and Normal plan was somewhere in between.Conclusion Low CGS has to be used as much as possible to obtain accurate dose distribution during SBRT planning for NSCLC patients,which contributes to the execution of the radiation therapy plan and the prevention of ad-verse effects.[Chinese Medical Equipment Journal,2024,45(2):52-57]
7.Theoretical Reaction Model Combined with Characteristic MS2 Information for Systematical Detection and Annotation of Novel Theaflavins in Yunnan Black Tea
Yong-Lin LI ; Jie GUO ; Zhi-Hao YU ; Si-Yu LI ; Yong-Dan HU ; Lun-Zhao YI ; Da-Bing REN
Chinese Journal of Analytical Chemistry 2024;52(6):846-855,中插24-中插35
In black tea,theaflavins (TFs) are one important class of substances that determine sensory quality and have significant medicinal activities. In addition to the four kinds of common TFs,there may be many other theaflavin analogues (TFAs) with similar chemical structures in tea,but the study on them is very limited. Based on the characteristic sub-structure,mass spectrometry (MS) and MS/MS information,a method for screening and annotation of TFAs from the complex ultra high performance liquid chromatography-high-resolution mass spectrometry (UPLC-HRMS) data was proposed in this work. By analyzing the oxidation and polymerization process of a few TFs,the theoretical reaction model of TFs were summarized,which was used to calculate the precursor ion values of potential TFAs. Meanwhile,the diagnostic fragmentation ions and neutral loss of TFAs according to the fragmentation pathways obtained from chemical standards or documented in literatures were summarized. As a result,36 kinds of compounds were successfully annotated based on the calculated precursor ion values and the MS fragmentation patterns,among which 6 kinds of compounds were reported for the first time in tea. In vitro synthesis experiments were carried out to verified the annotation results. Based on the results of quantitation of 36 kinds of TFAs,a partial least squares-discriminant analysis model was used to investigate the changes of these components during black tea manufacturing. The results indicated that these novel TFAs could be used to effectively distinguish the black tea samples before and after fermentation.
8.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
9.Accuracy of axis pedicle screw placement in robot-assisted upper cervical surgery
Jiayuan WU ; Da HE ; Yi WEI ; Fangfang DUAN ; Bo LIU ; Qiang YUAN ; Lin HU ; Xieyuan JIANG
Chinese Journal of Orthopaedics 2024;44(17):1125-1132
Objective:To evaluate the precision of robot-assisted axis pedicle screw placement and to evaluate the factors influencing the accuracy of the placement.Methods:The medical records of 27 consecutive patients who underwent posterior internal fixation of the upper cervical spine for atlantoaxial instability with intraoperative robot-assisted axis pedicle screw placement from January 2017 to December 2020 at Beijing Jishuitan Hospital were retrospectively analyzed. T The cohort comprised 10 males and 17 females, aged 41.3±16.6 years (range 12-75 years), with a body mass index (BMI) of 23.0±2.9 kg/m 2 (range 18.9-30.0 kg/m 2). There were 16 cases of traumatic atlantoaxial instability and 11 cases of atlantoaxial instability caused by deformity. The accuracy of robot-assisted axis pedicle screw placement was evaluated by postoperative CT using Gertzbein-Robbins scale. Factors potentially affecting placement accuracy were initially identified via univariate analysis, with significant factors ( P<0.200) subsequently analyzed through multivariate modeling using generalized estimating equations. Results:A total of 49 axis pedicle screws were placed in 27 patients, with 35 (71.4%) in Gertzbein-Robbins scale grade A, 12 (24.5%) in grade B, 2 (4.1%) in e grade C, and 0 in grades D and E. The clinically acceptable rate (Gertzbein-Robbins grades A and B) was 95.9%. No patient experienced vascular or neurologic injury due to screw displacement. The results of univariate analysis showed no statistical significance for patient factors (age, gender, BMI, preoperative cervical curvature, and causes of atlantoaxial instability); no statistical significance for the surgical factors of tracker position, screw position, screw type, and screw placement approach ( P>0.05), and a statistically significant difference for the difference between the effective width of the axis pedicle and the screw diameter ( t=3.484, P<0.001). The results of multifactorial analysis showed that tracker fixation to the Mayfield frame in robot-assisted axis pedicle screw placement over the axis spinous process resulted in more accurate screw placement [ OR=83.231, 95% CI(3.898, 1776.952), P=0.005]; and the greater the difference between the effective width of the axis pedicle and the diameter of the screw, the greater the accuracy of screw placement [ OR=5.330, 95% CI(1.648, 17.243), P=0.005]. Conclusion:Robot-assisted axis pedicle screw placement is both precise and safe. Securing the tracker to the Mayfield clamp rather than the axis spinous process enhances the accuracy of screw placement. A greater discrepancy between the axis pedicle's effective width and the screw diameter decreases the likelihood of cortical violation. Preoperative planning, including the selection of appropriate screw types and adjusting the trajectory in three dimensions to maximize the difference between the pedicle's effective width and the screw diameter, can mitigate the risk of cortical breach and subsequent vascular and neurological injury.
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail