1.Nationwide Survey on Endoscopic Submucosal Dissection for Early Gastric Cancer in Korea: Results From the Korean College of Helicobacter and Upper Gastrointestinal Research (KCHUGR) 2023 Survey
Jae Yong PARK ; Jeong Hoon LEE ; Tae-Se KIM ; Da Hyun JUNG ; Bong Eun LEE ; Yonghoon CHOI ; Wan-Sik LEE ; Young-Il KIM ; Sun Hyung KANG ; Hyunsoo CHUNG ; Su Jin KIM ; Joon Sung KIM ; Donghoon KANG ; Su Youn NAM ; Seung Han KIM ; Hyo-Joon YANG ; Hyun LIM ; Jin LEE ; Seon-Young PARK ; Seung-Woo LEE ; Sun Moon KIM ; Sam Ryong JEE ; Dae Young CHEUNG ; Chung Hyun TAE ; Seokin KANG ; Sung Chul PARK ; Seung In SEO ; Cheol Min SHIN ; Kee Don CHOI ; Jong Yeul LEE ;
Journal of Gastric Cancer 2026;26(2):169-183
Purpose:
Endoscopic submucosal dissection (ESD) has become a standard minimally invasive treatment for selected patients with early gastric cancer (EGC). This study presents the first nationwide survey of patients with EGC treated with ESD in 2023, conducted by the Korean College of Helicobacter and Upper Gastrointestinal Research.
Materials and Methods:
Data were retrospectively collected from participating referral centers across Korea using a standardized case report form covering patient characteristics, tumor features, procedural details, histopathological findings, and clinical outcomes.Descriptive and comparative analyses were conducted to summarize nationwide ESD practice patterns and outcomes.
Results:
Data from 5,460 ESD cases from 5,250 patients across 27 institutions were analyzed. The mean age was 67.4 years, with 74.1% males. Multiple synchronous lesions were identified in 3.7%. Most lesions were located in the lower third of the stomach (64.0%), and differentiated-type adenocarcinomas accounted for 87.8%. The en bloc and complete resection rates were 99.2% and 91.4%, respectively. Curative resection was achieved in 80.5%, whereas local non-curative resection (L-NCR) and surgical non-curative resection (S-NCR) were identified in 2.8% and 16.7%, respectively. Additional surgery was performed more frequently in patients with S-NCR than in those with L-NCR (59.3% vs. 24.7%). The bleeding and perforation rates were 3.6% and 0.9%, respectively, and were mostly managed conservatively or endoscopically. The median length of hospitalization was 4.0 days.
Conclusions
This first nationwide survey provides a comprehensive overview of the current practice of EGC treatment using ESD in Korea, demonstrating high technical success and safety, and establishing a baseline dataset for future longitudinal research.
2.Clinical Outcomes of Endoscopic Radiofrequency Stretta Therapy for Gastroesophageal Reflux Disease Treatment: A Retrospective Analysis From2 Tertiary Centers in Korea
Hyun LIM ; Yuri KIM ; Jin Hee NOH ; Jung In LEE ; Eun Jeong GONG ; Boram CHA ; Chan Hyuk PARK ; Da Hyun JUNG ; Ju Yup LEE ; Sun Hyung KANG ; In Kyung YOO ; Joo Young CHO ; Do Hoon KIM ;
Journal of Neurogastroenterology and Motility 2026;32(2):290-297
Background/Aims:
Endoscopic anti-reflux therapy is a therapeutic option for gastroesophageal reflux disease (GERD), providing durable effects. However, clinical data from Korea remain limited. This study evaluates the clinical outcomes of endoscopic radiofrequency Stretta therapy in Korean patients.
Methods:
A retrospective analysis was conducted on 71 patients with GERD who underwent Stretta therapy at 2 tertiary hospitals in Korea between November 2015 and July 2021. Clinical outcomes, including patient satisfaction, medication cessation or reduction, and complications, were evaluated. Pre- and post-procedural esophageal manometry and 24-hour pH monitoring test results were also analyzed.
Results:
Patient satisfaction rates at 1, 6, and 12 months post-procedure were 54.7% (35/64), 70.0% (28/40), and 75.0% (21/28), respectively. Medication cessation or reduction was achieved in 31.2% (20/64) at 1 month, 70.0% (28/40) at 6 months, and 67.9% (19/28) at 12 months. Esophageal manometry (n = 21) showed no significant changes in mean lower esophageal sphincter pressure (18.7 mmHg [2.5-52.9] vs 17.4 mmHg [0.0-43.0], P = 0.702) or mean integrated relaxation pressure (8.2 mmHg [0.0-28.0] vs 10.1 mmHg [0.0-31.0], P = 0.840). The 24-hour pH monitoring (n = 18) demonstrated a nonsignificant decrease in acid exposure time (pH < 4) from 2.3% (0.0-8.4) to 1.6% (0.0-7.3) (P = 0.182). Similarly, the DeMeester score decreased non-significantly from 8.4 (0.8-27.7) to 6.6 (0.8-21.8) (P = 0.352). No procedure-related complications occurred.
Conclusion
Endoscopic radiofrequency Stretta therapy appears to be a safe treatment option for GERD and may provide favorable patient satisfaction and medication reduction.
3.Nationwide Survey on Endoscopic Submucosal Dissection for Early Gastric Cancer in Korea: Results From the Korean College of Helicobacter and Upper Gastrointestinal Research (KCHUGR) 2023 Survey
Jae Yong PARK ; Jeong Hoon LEE ; Tae-Se KIM ; Da Hyun JUNG ; Bong Eun LEE ; Yonghoon CHOI ; Wan-Sik LEE ; Young-Il KIM ; Sun Hyung KANG ; Hyunsoo CHUNG ; Su Jin KIM ; Joon Sung KIM ; Donghoon KANG ; Su Youn NAM ; Seung Han KIM ; Hyo-Joon YANG ; Hyun LIM ; Jin LEE ; Seon-Young PARK ; Seung-Woo LEE ; Sun Moon KIM ; Sam Ryong JEE ; Dae Young CHEUNG ; Chung Hyun TAE ; Seokin KANG ; Sung Chul PARK ; Seung In SEO ; Cheol Min SHIN ; Kee Don CHOI ; Jong Yeul LEE ;
The Korean Journal of Helicobacter and Upper Gastrointestinal Research 2026;26(1):50-59
Objectives:
Endoscopic submucosal dissection (ESD) has become a standard minimally invasive treatment for selected patients with early gastric cancer (EGC). This study presents the first nationwide survey of patients with EGC treated with ESD in 2023, conducted by the Korean College of Helicobacter and Upper Gastrointestinal Research.
Methods:
Data were retrospectively collected from participating referral centers across Korea using a standardized case report form covering patient characteristics, tumor features, procedural details, histopathological findings, and clinical outcomes. Descriptive and comparative analyses were conducted to summarize nationwide ESD practice patterns and outcomes.
Results:
Data from 5460 ESD cases from 5250 patients across 27 institutions were analyzed. The mean age was 67.4 years, with 74.1% males. Multiple synchronous lesions were identified in 3.7%. Most lesions were located in the lower third of the stomach (64.0%), and differentiated-type adenocarcinomas accounted for 87.8%. The en bloc and complete resection rates were 99.2% and 91.4%, respectively. Curative resection was achieved in 80.5%, whereas local non-curative resection (L-NCR) and surgical non-curative resection (S-NCR) were identified in 2.8% and 16.7%, respectively. Additional surgery was performed more frequently in patients with S-NCR than in those with L-NCR (59.3% vs. 24.7%). The bleeding and perforation rates were 3.6% and 0.9%, respectively, and were mostly managed conservatively or endoscopically. The median length of hospitalization was 4.0 days.
Conclusions
This first nationwide survey provides a comprehensive overview of the current practice of EGC treatment using ESD in Korea, demonstrating high technical success and safety, and establishing a baseline dataset for future longitudinal research.
4.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
6.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
8.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
9.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
10.Guideline for the diagnosis and treatment of vertebral refracture after percutaneous vertebral augmentation in elderly patients with osteoporotic thoracolumbar compression fractures (version 2025)
Yong YANG ; Xiaoguang ZHOU ; Qixin CHEN ; Jian CHEN ; Jian DONG ; Liangjie DU ; Shunwu FAN ; Jin FAN ; Zhong FANG ; Haoyu FENG ; Shiqing FENG ; Haishan GUAN ; Aiguo GAO ; Yanzheng GAO ; Yong HAI ; Da HE ; Dengwei HE ; Haiyi HE ; Dianming JIANG ; Xuewen KANG ; Bin LIN ; Baoge LIU ; Changqing LI ; Fang LI ; Li LI ; Fangcai LI ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Xinyu LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Xuhua LU ; Fei LUO ; Yuhai MA ; Keya MAO ; Xuexiao MA ; Bin MENG ; Xu NING ; Limin RONG ; Hongxun SANG ; Jun SHU ; Tiansheng SUN ; Dasheng TIAN ; Zheng WANG ; Bing WANG ; Linfeng WANG ; Qingde WANG ; Qinghe WANG ; Lan WEI ; Jigong WU ; Baoshan XU ; Youjia XU ; Guoyong YIN ; Jinglong YAN ; Feng YAN ; Cao YANG ; Huilin YANG ; Qiang YANG ; Bin ZHAO ; Jie ZHAO ; Yue ZHU ; Jianguo ZHANG ; Wenzhi ZHANG ; Zhongmin ZHANG ; Zhaomin ZHENG ; Yan ZENG ; Baorong HE ; Wei MEI
Chinese Journal of Trauma 2025;41(7):613-626
Vertebral refracture following percutaneous vertebral augmentation (PVA) is commonly seen in elderly patients with osteoporotic thoracolumbar compression fractures (OTLCF). It can lead to recurrent pain, loss of vertebral height, progression of kyphosis, and even neurological dysfunction, significantly impairing patients′ quality of life. Current diagnosis and treatment face multiple challenges, including high misdiagnosis rate, difficulty in choosing between surgical and non-surgical treatment options, lack of standardized surgical protocols, interference from intralesional bone cement during procedures, inadequate stability of internal fixation in osteoporotic bone, and suboptimal compliance of anti-osteoporotic therapy. Establishing a standardized diagnostic and therapeutic framework is urgently needed. To standardize the management process and improve outcomes for vertebral refractures after PVA in elderly OTLCF patients, Spinal Trauma Group of the Orthopedic Branch of Chinese Medical Doctor Association organized experts in the field to develop Guideline for the diagnosis and treatment of vertebral refracture after percutaneous vertebral augmentation in elderly patients with osteoporotic thoracolumbar compression fractures ( version 2025), based on current literature and clinical experience, and adhering to principles of scientific rigor and clinical applicability. A total of 11 recommendations were proposed, encompassing diagnosis, treatment, and rehabilitation of vertebral refracture after PVA in elderly patients with OTLCF, aiming to provide a foundation for a standardized management.

Result Analysis
Print
Save
E-mail