1.Analysis of Cardiac Reverse Remodeling After Transcatheter Edge-to-edge Repair of Mitral Regurgitation due to Various Etiologies and Experience of Echocardiography Application
Zhiling LUO ; Xiaoli DONG ; Qiuzhe GUO ; Yuanzheng WANG ; Jin LI ; Yunfei ZHOU ; Shuanglan YU ; Da ZHU ; Shouzheng WANG ; Xiangbin PAN
Chinese Circulation Journal 2024;39(3):234-241
Objectives:To evaluate the valvular and cardiac function,cardiac reverse remodeling at 6-month after transcatheter edge-to-edge repair(TEER)for patients with functional and degenerative mitral valve regurgitation,and summarize the experience of echocardiography application. Methods:The clinical data of 93 patients with moderate to severe mitral regurgitation(MR)treated with TEER and completed 6-month follow-up in Yunnan Fuwai Cardiovascular Hospital from July 2022 to February 2023 were retrospectively analyzed.Patients were divided into functional mitral regurgitation(FMR)and degenerative mitral regurgitation(DMR)groups according to MR etiology.The valve characteristic parameters,as well as valvular function,chamber volume and cardiac functional parameters before and at 6 months after operation were compared.The key points of echocardiography application were summarized. Results:Among all patients,71 were FMR and 22 were DMR.There were differences in valve structure between the two groups.Mitral TEER were successfully accomplished and all patients completed 6-month follow-up.The key points of echocardiography application included:valve structure analysis,atrial septal puncture location,device delivery process monitoring and image optimization during clamping process.The mitral regurgitation grade and NYHA grade were significantly improved in all patients at 6 months after TEER(P<0.05),and the mean mitral valve pressure gradient was higher than that before operation(P<0.05).Left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV)and left atrial volume index in FMR group were significantly decreased(P<0.05),while left ventricular and left atrial volume in DMR group remained unchanged(P>0.05).There were no significant changes in left ventricular ejection fraction and left ventricular global strain in both groups during the observation period(P>0.05).The changes of LVEDV and LVESV before and after operation were more significant in FMR group than those in DMR group(P<0.05). Conclusions:Mitral TEER can reduce the degree of regurgitation and improve cardiac function in the early postoperative period for moderate and severe MR patients with different etiologies.There are differences in preoperative valve structure and postoperative cardiac reverse remodeling between FMR and DMR patients.Echocardiography is an important imaging technique for the evaluation and monitoring process before,during and post mitral TEER.
2.Research progress on the characteristics of head injury in children and adolescents
HUANG Da, LUO Weidong, XU Zhen, XIAO Li
Chinese Journal of School Health 2024;45(4):604-608
Abstract
The harm of head injury in skateboarding is more serious. The common injury cause is fall, collision, high speed impact. The primary types of injury include skull fracture, subdural hemorrhage, brain laceration contusion and concussion. Older children and adolescents, males, longboard, inappropriate sports venue are important risk factors for severe traumatic brain injury. Designing special skateboard parks and wearing protective equipment (helmets) can effectively reduce the incidence and severity of head injuries. The occurrence of injury can be reduced by adopting both legislation and education measures.
3.Visual analysis of hot topics in concussion field by finite element method:Improvements in brain injury models,test methods and protective devices
Weidong LUO ; Lihua ZOU ; Da HUANG
Chinese Journal of Tissue Engineering Research 2024;28(34):5487-5493
BACKGROUND:Concussions caused by contact sports or traffic accidents are far more serious and common than people think,and have attracted widespread attention and high attention from the media,medical and sports circles in recent years. OBJECTIVE:To visualize the hot spots and trends in the field of concussion by using the method of bibliometrics,so as to provide some reference for the research in this field in China. METHODS:Based on the core collection database of Web of Science,the keyword retrieval strategy was(TS=(Concussion))AND TS=(Finite element).CiteSpace 6.2.R4 visualization tool was used to visually analyze the author,country,institution,keywords,cited documents,etc. RESULTS AND CONCLUSION:A total of 215 articles were included,with a general upward trend in the number of publications and citations.The distribution of disciplines involves biomedical engineering,biophysics,sports science,clinical neurology,neuroscience and other disciplines,showing a trend of interdisciplinary integration.The author with the most publications is Gilchrist M from University College Dublin,Ireland,the institution with the most publications is the University of Ottawa,and the country with the most publications is the United States.Key word analysis shows that the focus of research is on the establishment of brain injury models to simulate and predict concussion injuries;analysis of concussion injury mechanism;optimal design of protective equipment and devices.Through literature co-citation analysis,it is found that the prediction and evaluation of brain injury is the knowledge base and research hotspot in this field.The research hotspot of finite element application in the field of concussion injury mainly focuses on the prediction of head injury,combined with the exploration of brain injury mechanism and the design and improvement of protective equipment.With the progress of artificial intelligence and materials science,future research hotspots in the field of concussion injury will focus on the improvement of brain injury models,test methods and protective equipment.
4.Current applications of transcatheter edge-to-edge tricuspid valve repair
Chun-Mei XIE ; Meng-Qi SHEN ; Da ZHU ; Shou-Zheng WANG ; Zhi-Ling LUO ; Xiang-Bin PAN
Chinese Journal of Interventional Cardiology 2024;32(1):45-50
Tricuspid regurgitation(TR)is a common heart valve disease.According to the pathogenesis,TR can be divided into primary(organic)and secondary(functional)regurgitation,of which functional TR accounts for more than 90%.Patients with severe TR have poor prognosis and poor drug treatment,and surgery(valvuloplasty)is the main treatment.At present,transcatheter edge-to-edge tricuspid valve repair(T-TEER)has become an essential program of transcatheter treatment for TR,providing minimally invasive treatment for TR patients who cannot undergo surgery or are at high risk of surgery.T-TEER reduces the degree of regurgitation by clamping leaflets,and is currently in the early stage of research and development exploration and clinical validation,mainly for functional TR.T-TEER devices have also made significant progress(TriClip,PASCAL),and Chinese-made novel-designed T-TEER devices are also undergoing clinical trials(DragonFly-TTM,SQ-Kyrin-TTM,NeoBlazarTM).This paper reviews the current applications and research progress of T-TEER.
5.Expression and Significance of GATA-3, H3K27me3 in Tibetan Patients with Bladder Urothelial Carcinoma
Zhuoma NIMA ; Yu XIAO ; Hanhuan LUO ; Bula DUO ; Han WANG ; Zhen DA ; Jiangcun SILANG ; Pingping GUO ; Ruiqian LIAO
Medical Journal of Peking Union Medical College Hospital 2024;15(4):953-959
To investigate the expression and clinical significance of GATA-3 and H3K27me3 in Tibetan patients with bladder urothelial carcinoma (BUC). BUC and normal bladder tissues were collected retrospectively from January 2016 to December 2021 in the People's Hospital of Tibet Autonomous Region. The expression of GATA-3 and H3K27me3 in both tissues was detected by immunohistochemical method, and the clinical and pathological characteristics were statistically analyzed. A total of 70 patients with BUC were selected, including 51 males and 19 females, with an average age of (60.5±12.0) years. At the same time, 20 normal bladder tissue samples were collected during the same period. All cases were Tibetan patients. Immunohistochemistry results showed that the high expression rate of GATA-3 in BUC and normal bladder tissue was 70.0%(49/70) and 100%(20/20), respectively. High expression of GATA-3 was associated with male, low pathological grade, and non-invasive tissue(all The expression of GATA-3 was down regulated in Tibetan BUC patients, and significantly down regulated with the increase of tumor grade, suggesting that GATA-3 may be involved in the occurrence and development of BUC and related to its malignancy, providing reference for clinical diagnosis and treatment as well as judging disease prognosis. The expression of H3K27me3 in Tibetan BUC patients was higher than that in normal bladder tissue, suggesting that H3K27me3 may be a new immune marker for diagnosis of BUC.
6.Preparation of Metal Organic Framework-derived Microflower-Like NiO-In2O3 Composite Structure and Its Detection Performance for Ultra-Low Concentration of Formaldehyde Gas
Cui-Xian LUO ; Jiao-Hong HOU ; Wen-Tao JIA ; Da-Ming WANG ; Ling-Rong XUE
Chinese Journal of Analytical Chemistry 2024;52(8):1141-1151
Formaldehyde is a prevalent organic solvent in industrial and indoor environment,which can seriously harm human health,so it is of great significance to develop highly sensitive formaldehyde sensors with fast response,low detection limit and long life.In this study,the NiO-In2O3 composite structure was prepared using indium-based metal organic framework(In-MOF)as the precursor,and the formaldehyde gas sensor was constructed with In2O3 and NiO-In2O3 composite structure as the sensitive material.The results demonstrated that the In2O3 material had a microflower-like structure,while the NiO-In2O3 composite structure was composed of NiO nanoparticles attached to the surface of In2O3.The sensor exhibited excellent detection performance for formaldehyde in the environment of relative humidity of 33%and 75%,especially the response characteristic of the NiO-In2O3 composite structure sensor to formaldehyde was considerably better than that of the In2O3 sensor under the same test conditions,which was closely related to the catalytic effect of NiO and the heterogeneous structure formed between NiO and In2O3.The NiO-In2O3 composite structure sensor had a response value of 21.3 and 12.6 to 10 μL/L formaldehyde when the relative humidity was 33%and 75%at 200℃.The response/recovery time was 4/6 s and 7/10 s,and the limit of detection(LOD)was 1.2×10-7 μL/L and 4.1×10-5 μL/L respectively.Meanwhile,the sensor had excellent selectivity and long-term stability.This sensor showed a wide application prospect in the field of high-performance detection of low concentration of formaldehyde gas.
7.A nationwide multicenter prospective study on the perioperative impact of closure of mesen-teric fissure in laparoscopic right hemicolectomy
Gang LIU ; Weimin XU ; Da LI ; Lei QIAO ; Jieqing YUAN ; Dewei ZHANG ; Yan LIU ; Shuai GUO ; Xu ZHANG ; Wenzhi LIU ; Yingfei WANG ; Hang LU ; Xiaowei ZHANG ; Xin CHEN ; Zhaohui XU ; Xingyang LUO ; Ge LIU ; Cheng ZHANG ; Jianping ZHOU
Chinese Journal of Digestive Surgery 2024;23(6):812-818
Objective:To investigate the perioperative impact of closure of mesenteric fissure in laparoscopic right hemicolectomy.Methods:The prospective randomized controlled trial was conducted. The clinical data of 320 patients who underwent laparoscopic right hemicolectomy in 11 medical centers, including The First Affiliated Hospital of China Medical University et al, from November 2022 to August 2023 were selected. Based on block randomization, patients were alloca-ted into the mesenteric fissure non-closure group and the mesenteric fissure closure group. Observa-tion indicators: (1) grouping of the enrolled patients; (2) intraoperative conditions; (3) postopera-tive conditions. Measurement data with skewed distribution were represented as M( Q1, Q3) and com-parison between groups was conducted using the Mann-Whitney U test. Count data were represen-ted as absolute numbers or percentages, and comparison between groups was conducted using the chi-square test or Fisher's exact probability. Comparison of ordinal data was conducted using the rank sum test. Comparison of visual analog scores was analyzed using generalized estimating equations. Results:(1) Grouping of the enrolled patients. A total of 320 patients with colon cancer were screened for eligibility, including 156 males and 164 females, aged 68(59,73)years. All the 320 patients were allocated into the mesenteric fissure non-closure group with 164 cases and the mesenteric fissure closure group with 156 cases. There was no significant difference in the age, body mass index, American Society of Anesthesiologist score, maximum tumor diameter, anastomosis location, anastomosis method, surgical approach, range of lymph node dissection, tumor staging between the two groups ( P>0.05) and there was a significant difference in the sex between them ( P<0.05). (2) Intraoperative conditions. There was no significant difference between the mesenteric fissure closure group and the mesenteric fissure non-closure group in the volume of intraoperative blood loss, operation time, conversion to laparotomy, intraoperative complication ( P>0.05). Three patients in the mesenteric fissure non-closure group were converted to laparotomy. One patient in the mesenteric fissure closure group was converted to laparotomy, and 2 cases with intraoperative complication were mesenteric hematoma. (3) Postoperative conditions. There was no significant difference between the mesenteric fissure non-closure group and the mesenteric fissure closure group in the overall postoperative complications ( χ2=0.28, P>0.05). There was no significant difference in the occurrence of postoperative intestinal obstruction, abdominal distension, ascites, pleural effusion, gastric paralysis, anastomotic bleeding, anastomotic leakage, or surgical wound infection between the two groups ( P>0.05). There was no significant difference between the two groups in the reoperation, postoperative gastric tube replacement. There was no significant differ-ence in time to postoperative first flatus, time to postoperative initial liquid food intake, time to post-operative resumption of bowel movements, duration of postoperative hospital stay, total hospital expenses between the two groups ( Z=-0.01, 0.43, 1.04, -0.54, -0.36, P>0.05). One patient in the mesenteric fissure non-closure group received reoperation. No perioperative internal hernia or death occurred in either group. The visual analog score decreased with time in both groups. There was no significant difference in the visual analog score between the mesenteric fissure closure group and the mesenteric fissure non-closure group [ β=-0.20(-0.53,0.13), P>0.05]. Conclusion:Compared with closure of mesenteric fissure, non-closure of mesenteric fissure during laparoscopic right hemi-colectomy dose not increase perioperative complications or postoperative management risk.
8.Expression and activity analysis of Clostridium difficile toxin B type 2
Xing-Hao LIN ; Kai ZHANG ; Meng-Jie WANG ; Ming YANG ; Han-Yang GU ; Xiao-Lan XUE ; Yong-Neng LUO ; Da-Zhi JIN ; Hui HU
Chinese Journal of Zoonoses 2024;40(6):498-503
This study was aimed at creating an engineered strain of Bacillus subtilis for efficient expression of biologically active type 2 toxin B(TcdB2)derived from a highly virulent strain of Clostridium difficile.The TcdB2 gene was cloned from ST1/RT027 strain genome DNA,incorporated into the PHT01 vector,and then transformed into B.subtilis strain WB800N for prokaryotic expression.Cell toxicity assays revealed that the recombinant TcdB2 exhibited cytotoxic effects in various cells.The engineered B.subtilis strain effectively expressed biologically active TcdB2,thus providing a basis for further exploration of the pathogenic mechanisms of highly virulent strains of C.difficile and establishing a foundation for potential vaccine can-didate targets.
9.Establish a Graded Method to Avoid HLA Class I Antibodies Cor-responding Antigen and Combining HLAMatchmaker Application in Improving the CCI Value after Platelet Transfusion for Patients with IPTR
Su-Qing GAO ; Yun-Ping XU ; Chang-Ru LUO ; Da-Cheng LI ; Long PEN ; Tong LIU ; Qiong-Cai ZOU
Journal of Experimental Hematology 2024;32(1):242-249
Objective:To establish a graded method to avoid mean fluorescence intensity(MFI)threshold of HLA Class I antibodies corresponding antigen,and the HLAMatchmaker program has been used to select the minimum mismatch value of donor-patient epitopes.Evaluate the application value of combining both methods in selecting HLA compatible platelets(PTL)for patients with immune platelet transfusion failure(IPTR)in improving platelet the corrected count increment(CCI).Methods:A total 7 807 PLT cross-matching compatible were performed by the solid-phase red cell adherence(SPRCA)method for 51 IPTR patients.The Luminex single antigen flow cytometry was used to detect HLA Class I antibodies in patients,and detected the MFI value for different specificity antigens of HLA Class I antibodies,was graded into strong positive group(MFI>4 000,level 1),medium positive group(1 000<MFI 4 000,2),weak positive group(500<MFI≤1 000,3),and one negative control group(MFI≤500).The results of 7 807 SPRCA their negative/positive reaction wells were enrolled and statistically analyzed in different grades and the four groups,the statistical differences between the four groups were compared.Multiple applications for the select HLA Class I compatible donor events were made for patients in two cases,and HLAMatchmaker program was used to calculate the number of HLA Class I epitopes mismatches between the donors and patients.The donor with the minimum number of epitopes mismatches was selected,while avoiding the corresponding antigens of HLA Class I antibodies in levels 1 and 2,the provision of HLA compatible platelets for IPTR.After the transfusions,the CCI value of the platelet transfusion efficacy evaluation index was calculated,and the clinical evaluation of the transfusion effect was obtained through statistical analysis.Results:There were statistically significant differences in the positive results of SPRCA immunoassay among the strong positive group,medium positive group,and weak positive group of 51 IPTR patients with different specific of HLA-I class antibodies and corresponding antigens(all P<0.001).The positive results showed a range from high to low,with strong positive group>medium positive group>weak positive group.There were a statistical difference among between the strongly positive or moderately positive groups and the negative control group(P<0.001).There was no statistical difference between the weakly positive group and the negative control group(P>0.05).The strong positive group was set as the corresponding specific HLA Class I site corresponding antigen grade 1 avoidance threshold,the medium positive group as the grade 2 avoidance thresholds,and the weak positive group as the grade 3 avoidance threshold.In the case of donor platelet shortage,it is not necessary to avoid the weak positive group.Avoiding the strategy of donor antigens and HLAMatchmaker program scores≤7 corresponding to HLA Class I antibodies of levels 1 and 2,with CCI values>4.5 × 109/L within 24 hours,can obtain effective clinical platelet transfusion conclusions.Conclusion:When selecting HLA Class I compatible donors for IPTR patients,the grading avoids HLA Class I antibodies corresponding to donor antigens,and the donor selection strategy with the minimum scores of HLAMatchmaker program is comprehensively selected.The negative result confirmed by platelet cross-matching experiments has certain practical application value for improving platelet count in IPTR patients.
10.Robotic Assisted Transcatheter Edge-to-edge Repair for Functional Mitral Regurgitation With Pure Trans-esophageal Echocardiography-guidance
Da ZHU ; Wenbin OUYANG ; Shouzheng WANG ; Zhiling LUO ; Xiangbin PAN
Chinese Circulation Journal 2024;39(6):606-609
We report the first in man experience of robotic assisted transcatheter edge-to-edge repair(TEER)with pure Trans-esophageal echocardiography-guidance.A 55y female was diagnosed with heart failure with 4+functional MR despite optimal medical treatment.TEER procedure was planned with robotic assistance.After guiding catheter,the robotic system was incorporated into the TEER device to replace manual operation.Under pure echo-guidance one clip was successfully placed in A2/P2 region with marked reduction of MR to 1+.Patient was discharged without complication.


Result Analysis
Print
Save
E-mail