1.Clinical Efficacy and Scalp Microbiome Changes Induced by AMPamide-Containing Shampoo in Patients With Seborrheic Dermatitis
Yi Na YOON ; Sae Hee KIM ; Ji Won LIM ; Myeong Jae KIM ; Hye-Jin KIM ; Woo Jun SUL ; Daehwan KIM ; Wonseok JEONG ; Jeonghwan HWANG ; Da-Ae YU ; Yong Beom CHOE ; Yang Won LEE
Annals of Dermatology 2026;38(3):237-247
Background:
Seborrheic dermatitis (SD) is a chronic inflammatory scalp disorder associated with Malassezia dysbiosis and increased sebum production. AMPamide has been suggested to have anti-inflammatory and sebum-regulating effects, but its clinical efficacy and microbiome-modulating effects in SD remain unclear.
Objective:
To evaluate the clinical efficacy and scalp microbiome changes following 4 weeks of use of an AMPamide-containing shampoo in patients with SD.
Methods:
In this observational study, 30 patients with SD applied an AMPamide-containing shampoo for 4 consecutive weeks. Clinical outcomes, including sebum levels and overall severity scores, were assessed. Scalp bacterial and fungal communities were analyzed to evaluate α- and β-diversity and changes in Malassezia composition.
Results:
Treatment resulted in significant reductions in sebum levels and clinical severity scores, particularly in erythema, dandruff, and pruritus. Bacterial community composition remained largely stable, while fungal α-diversity increased, and β-diversity analysis revealed a decrease in the ratio of Malassezia restricta to Malassezia globosa.
Conclusion
AMPamide-containing shampoo was associated with improved clinical symptoms and a shift toward a more balanced fungal community composition in patients with SD, supporting its potential as a non-steroidal therapeutic option for SD.
2.Comparison of da Vinci SP and Xi surgical systems for robotic lateral transperitoneal adrenalectomy: a retrospective single-center observational study
Da Young YU ; Young Woo CHANG ; Dohoe KU ; Seung Yeon KO ; Hye Yoon LEE ; Gil Soo SON
Annals of Surgical Treatment and Research 2025;108(6):367-373
Purpose:
Robotic adrenalectomy was developed to address the limitations of laparoscopic adrenalectomy and enhance the visualization, dexterity, and control of surgeons performing this beneficial minimally invasive technique. This study compared the clinical and perioperative outcomes of lateral transperitoneal adrenalectomy using da Vinci SP and Xi robotic systems (Intuitive Surgical).
Methods:
We retrospectively analyzed 84 patients who underwent robotic adrenalectomies at a single institution between January 2019 and July 2024. Sixty-two and 22 patients were treated with da Vinci Xi and SP systems, respectively.
Results:
No significant differences in patient demographics, tumor size, or postoperative hospital stay between the 2 groups were observed. The SP system demonstrated significantly shorter operative times for right-sided adrenalectomy (81.0 ± 17.1 minutes vs. 113.3 ± 26.2 minutes, P < 0.001), whereas no significant differences were observed in overall operative time (104.9 ± 28.2 minutes for Xi vs. 93.5 ± 23.2 minutes for SP, P = 0.094) or left adrenalectomy (99.9 ± 28.4 minutes for Xi vs. 104.0 ± 23.0 minutes for SP, P = 0.253).
Conclusion
The da Vinci Xi and SP systems are both effective for robotic adrenalectomy, with the SP system showing particular advantages in right-sided procedures.
3.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
4.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
5.Attention to Innate Circadian Rhythm and the Impact of Its Disruption on Diabetes
Da Young LEE ; Inha JUNG ; So Young PARK ; Ji Hee YU ; Ji A SEO ; Kyeong Jin KIM ; Nam Hoon KIM ; Hye Jin YOO ; Sin Gon KIM ; Kyung Mook CHOI ; Sei Hyun BAIK ; Nan Hee KIM
Diabetes & Metabolism Journal 2024;48(1):37-52
Novel strategies are required to reduce the risk of developing diabetes and/or clinical outcomes and complications of diabetes. In this regard, the role of the circadian system may be a potential candidate for the prevention of diabetes. We reviewed evidence from animal, clinical, and epidemiological studies linking the circadian system to various aspects of the pathophysiology and clinical outcomes of diabetes. The circadian clock governs genetic, metabolic, hormonal, and behavioral signals in anticipation of cyclic 24-hour events through interactions between a “central clock” in the suprachiasmatic nucleus and “peripheral clocks” in the whole body. Currently, circadian rhythmicity in humans can be subjectively or objectively assessed by measuring melatonin and glucocorticoid levels, core body temperature, peripheral blood, oral mucosa, hair follicles, rest-activity cycles, sleep diaries, and circadian chronotypes. In this review, we summarized various circadian misalignments, such as altered light-dark, sleep-wake, rest-activity, fasting-feeding, shift work, evening chronotype, and social jetlag, as well as mutations in clock genes that could contribute to the development of diabetes and poor glycemic status in patients with diabetes. Targeting critical components of the circadian system could deliver potential candidates for the treatment and prevention of type 2 diabetes mellitus in the future.
6.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
7.Sleep Duration and the Risk of Type 2 Diabetes: A Community-Based Cohort Study with a 16-Year Follow-up
Da Young LEE ; Inha JUNG ; So Young PARK ; Ji Hee YU ; Ji A SEO ; Kyeong Jin KIM ; Nam Hoon KIM ; Hye Jin YOO ; Sin Gon KIM ; Kyung Mook CHOI ; Sei Hyun BAIK ; Seung Ku LEE ; Chol SHIN ; Nan Hee KIM
Endocrinology and Metabolism 2023;38(1):146-155
Background:
We aimed to investigate the moderating effects of obesity, age, and sex on the association between sleep duration and the development of diabetes in Asians.
Methods:
We analyzed data from a cohort of the Korean Genome and Epidemiology Study conducted from 2001 to 2020. After excluding shift workers and those with diabetes at baseline, 7,407 participants were stratified into three groups according to sleep duration: ≤5 hoursight, >5 to 7 hoursight (reference), and >7 hoursight. The Cox proportional hazards analyses were used to calculate the hazard ratios (HRs) and 95% confidence intervals (CIs) for incident type 2 diabetes mellitus (T2DM). Subgroup analyses were performed according to obesity, age, and sex.
Results:
During 16 years of follow-up, 2,024 cases of T2DM were identified. Individuals who slept ≤5 hight had a higher risk of incident diabetes than the reference group (HR, 1.17; 95% CI, 1.02 to 1.33). The subgroup analysis observed a valid interaction with sleep duration only for obesity. A higher risk of T2DM was observed in the ≤5 hoursight group in non-obese individuals, men, and those aged <60 years, and in the >7 hoursight group in obese individuals (HRs were 1.34 [95% CI, 1.11 to 1.61], 1.22 [95% CI, 1 to 1.49], and 1.18 [95% CI, 1.01 to 1.39], respectively).
Conclusion
This study confirmed the effect of sleep deprivation on the risk of T2DM throughout the 16-year follow-up period. This impact was confined to non-obese or young individuals and men. We observed a significant interaction between sleep duration and obesity.
8.Comparison of robotic and laparoscopic lateral transperitoneal adrenalectomies
Seung Yeon KO ; Young Woo CHANG ; Dohoe KU ; Da Young YU ; Hye Yoon LEE ; Woong Bae JI ; Gil Soo SON
Annals of Surgical Treatment and Research 2023;105(2):69-75
Purpose:
This study aimed to compare the intraoperative and postoperative outcomes between robotic and laparoscopic transperitoneal adrenalectomies.
Methods:
In this retrospective study, 93 patients underwent adrenalectomy using 2 surgical modalities: 45 patients underwent adrenalectomy using the da Vinci Xi system (robotic group), and 48 patients using laparoscopic devices (laparoscopic group). We compared the operation time, intraoperative bleeding, and hospital stay according to the surgical modality and tumor characteristics.
Results:
There were no significant differences in the operative time (P = 0.827), hospital stay (P = 0.177), and intraoperative bleeding (P = 0.174) between the groups. However, the robotic group showed a lower coefficient of variation in total operative time than that of the laparoscopic group (100.6 ± 23.3 minutes vs. 101.9±32.7 minutes, 0.230 vs. 0.321). When divided into 2 subgroups based on the tumor size (<3 cm and ≥3 cm), the robotic group with a tumor sized >3 cm had a shorter operative time than that of the laparoscopic group (P = 0.032). The robotic group also had fewer cases of intraoperative bleeding (P = 0.034).
Conclusions
Compared to the laparoscopic transperitoneal adrenalectomy, the robotic one achieved a lower deviation in total operative time and showed less bleeding and a shorter operative time, especially for tumors sized >3 cm.
9.Clinical and Lifestyle Determinants of Continuous Glucose Monitoring Metrics in Insulin-Treated Patients with Type 2 Diabetes Mellitus
Da Young LEE ; Namho KIM ; Inha JUNG ; So Young PARK ; Ji Hee YU ; Ji A SEO ; Jihee KIM ; Kyeong Jin KIM ; Nam Hoon KIM ; Hye Jin YOO ; Sin Gon KIM ; Kyung Mook CHOI ; Sei Hyun BAIK ; Sung-Min PARK ; Nan Hee KIM
Diabetes & Metabolism Journal 2023;47(6):826-836
Background:
There was limited evidence to evaluate the association between lifestyle habits and continuous glucose monitoring (CGM) metrics. Thus, we aimed to depict the behavioral and metabolic determinants of CGM metrics in insulin-treated patients with type 2 diabetes mellitus (T2DM).
Methods:
This is a prospective observational study. We analyzed data from 122 insulin-treated patients with T2DM. Participants wore Dexcom G6 and Fitbit, and diet information was identified for 10 days. Multivariate-adjusted logistic regression analysis was performed for the simultaneous achievement of CGM-based targets, defined by the percentage of time in terms of hyper, hypoglycemia and glycemic variability (GV). Intake of macronutrients and fiber, step counts, sleep, postprandial C-peptide-to-glucose ratio (PCGR), information about glucose lowering medications and metabolic factors were added to the analyses. Additionally, we evaluated the impact of the distribution of energy and macronutrient during a day, and snack consumption on CGM metrics.
Results:
Logistic regression analysis revealed that female, participants with high PCGR, low glycosylated hemoglobin (HbA1c) and daytime step count had a higher probability of achieving all targets based on CGM (odds ratios [95% confidence intervals] which were 0.24 [0.09 to 0.65], 1.34 [1.03 to 1.25], 0.95 [0.9 to 0.99], and 1.15 [1.03 to 1.29], respectively). And participants who ate snacks showed a shorter period of hyperglycemia and less GV compared to those without.
Conclusion
We confirmed that residual insulin secretion, daytime step count, HbA1c, and women were the most relevant determinants of adequate glycemic control in insulin-treated patients with T2DM. In addition, individuals with snack consumption were exposed to lower times of hyperglycemia and GV.
10.On-demand Versus Continuous Maintenance Treatment With a Proton Pump Inhibitor for Mild Gastroesophageal Reflux Disease: A Prospective Randomized Multicenter Study
Da Hyun JUNG ; Young Hoon YOUN ; Hye-Kyung JUNG ; Seung Young KIM ; Cheal Wung HUH ; Cheol Min SHIN ; Jung-Hwan OH ; Kyu Chan HUH ; Moo In PARK ; Suck Chei CHOI ; Ki Bae KIM ; Seon-Young PARK ; Joong Goo KWON ; Yu Kyung CHO ; Jung Ho PARK ; Jeong Eun SHIN ; Eun Jeong GONG ; Jae Hak KIM ; Su Jin HONG ; Hyun Jin KIM ; Sam Ryong JEE ; Ju Yup LEE ; Kee Wook JUNG ; Hee Man KIM ; Kwang Jae LEE
Journal of Neurogastroenterology and Motility 2023;29(4):460-469
Background/Aims:
It remains unclear which maintenance treatment modality is most appropriate for mild gastroesophageal reflux disease (GERD).We aimed to compare on-demand treatment with continuous treatment using a proton pump inhibitor (PPI) in the maintenance treatment for patients with non-erosive GERD or mild erosive esophagitis.
Methods:
Patients whose GERD symptoms improved after 4 weeks of standard dose PPI treatment were prospectively enrolled at 25 hospitals.Subsequently, the enrolled patients were randomly assigned to either an on-demand or a continuous maintenance treatment group, and followed in an 8-week interval for up to 24 weeks.
Results:
A total of 304 patients were randomized to maintenance treatment (continuous, n = 151 vs on-demand, n = 153). The primary outcome, the overall proportion of unwillingness to continue the assigned maintenance treatment modality, failed to confirm the noninferiority of on-demand treatment (45.9%) compared to continuous treatment (36.1%). Compared with the on-demand group, the GERD symptom and health-related quality of life scores significantly more improved and the overall satisfaction score was significantly higher in the continuous treatment group, particularly at week 8 and week 16 of maintenance treatment. Work impairment scores were not different in the 2 groups, but the prescription cost was less in the on-demand group. Serum gastrin levels significantly elevated in the continuous treatment group, but not in the on-demand group.
Conclusions
Continuous treatment seems to be more appropriate for the initial maintenance treatment of non-erosive GERD or mild erosive esophagitis than on-demand treatment. Stepping down to on-demand treatment needs to be considered after a sufficient period of continuous treatment.

Result Analysis
Print
Save
E-mail