1.A multi-city outbreak of Salmonella Enteritidis infections linked to bakery products, Republic of Korea
Da Seul KIM ; Soon-Young SEO ; Dong Hwi KIM ; Yeon Hee WOO ; Deborah LEE ; Se Jeong YANG ; Junyoung KIM ; Eunkyung SHIN ; Byungsun JUNG ; Eunmi LEE ; Min Jung LEE ; Young-Joon PARK
Osong Public Health and Research Perspectives 2026;17(1):61-71
Objectives:
In May 2025, clusters of salmonellosis were identified in 7 cities in the Republic of Korea, all associated with consumption of identical bakery products. This investigation aimed to characterize the outbreak, identify potential contributing factors, and inform strategies for preventing similar multi-facility foodborne outbreaks.
Methods:
A case series study was conducted among individuals who consumed Manufacturer H’s Product I and Product II on May 15–16, 2025 at 7 facilities (n = 1,235). Clinical specimens from symptomatic individuals, retained food samples, and environmental samples were collected and tested. Food-exposure histories were assessed, and active case finding was implemented across all supplied facilities. Traceback investigations were conducted at the manufacturer, distributor, and egg farms. Human and food isolates underwent pulsed-field gel electrophoresis (PFGE) and whole-genome sequencing (WGS).
Results:
A total of 323 cases met the outbreak case definition (attack rate, 26.2%), of which 48 were laboratory-confirmed. Salmonella Enteritidis was isolated from both clinical specimens and retained bakery products. PFGE patterns were indistinguishable between human and food isolates, and WGS demonstrated high genetic relatedness. These findings confirmed a common-source outbreak linked to the implicated bakery products.
Conclusion
This outbreak underscores the value of integrating epidemiological investigation, active case finding, and molecular typing to identify common food vehicles in outbreaks involving widely distributed manufactured foods. Coordinated collaboration between public health and food safety authorities is essential for the effective detection, response, and prevention of multi-facility foodborne outbreaks.
2.Clinical Outcomes of Endoscopic Radiofrequency Stretta Therapy for Gastroesophageal Reflux Disease Treatment: A Retrospective Analysis From2 Tertiary Centers in Korea
Hyun LIM ; Yuri KIM ; Jin Hee NOH ; Jung In LEE ; Eun Jeong GONG ; Boram CHA ; Chan Hyuk PARK ; Da Hyun JUNG ; Ju Yup LEE ; Sun Hyung KANG ; In Kyung YOO ; Joo Young CHO ; Do Hoon KIM ;
Journal of Neurogastroenterology and Motility 2026;32(2):290-297
Background/Aims:
Endoscopic anti-reflux therapy is a therapeutic option for gastroesophageal reflux disease (GERD), providing durable effects. However, clinical data from Korea remain limited. This study evaluates the clinical outcomes of endoscopic radiofrequency Stretta therapy in Korean patients.
Methods:
A retrospective analysis was conducted on 71 patients with GERD who underwent Stretta therapy at 2 tertiary hospitals in Korea between November 2015 and July 2021. Clinical outcomes, including patient satisfaction, medication cessation or reduction, and complications, were evaluated. Pre- and post-procedural esophageal manometry and 24-hour pH monitoring test results were also analyzed.
Results:
Patient satisfaction rates at 1, 6, and 12 months post-procedure were 54.7% (35/64), 70.0% (28/40), and 75.0% (21/28), respectively. Medication cessation or reduction was achieved in 31.2% (20/64) at 1 month, 70.0% (28/40) at 6 months, and 67.9% (19/28) at 12 months. Esophageal manometry (n = 21) showed no significant changes in mean lower esophageal sphincter pressure (18.7 mmHg [2.5-52.9] vs 17.4 mmHg [0.0-43.0], P = 0.702) or mean integrated relaxation pressure (8.2 mmHg [0.0-28.0] vs 10.1 mmHg [0.0-31.0], P = 0.840). The 24-hour pH monitoring (n = 18) demonstrated a nonsignificant decrease in acid exposure time (pH < 4) from 2.3% (0.0-8.4) to 1.6% (0.0-7.3) (P = 0.182). Similarly, the DeMeester score decreased non-significantly from 8.4 (0.8-27.7) to 6.6 (0.8-21.8) (P = 0.352). No procedure-related complications occurred.
Conclusion
Endoscopic radiofrequency Stretta therapy appears to be a safe treatment option for GERD and may provide favorable patient satisfaction and medication reduction.
3.Clinical Efficacy and Scalp Microbiome Changes Induced by AMPamide-Containing Shampoo in Patients With Seborrheic Dermatitis
Yi Na YOON ; Sae Hee KIM ; Ji Won LIM ; Myeong Jae KIM ; Hye-Jin KIM ; Woo Jun SUL ; Daehwan KIM ; Wonseok JEONG ; Jeonghwan HWANG ; Da-Ae YU ; Yong Beom CHOE ; Yang Won LEE
Annals of Dermatology 2026;38(3):237-247
Background:
Seborrheic dermatitis (SD) is a chronic inflammatory scalp disorder associated with Malassezia dysbiosis and increased sebum production. AMPamide has been suggested to have anti-inflammatory and sebum-regulating effects, but its clinical efficacy and microbiome-modulating effects in SD remain unclear.
Objective:
To evaluate the clinical efficacy and scalp microbiome changes following 4 weeks of use of an AMPamide-containing shampoo in patients with SD.
Methods:
In this observational study, 30 patients with SD applied an AMPamide-containing shampoo for 4 consecutive weeks. Clinical outcomes, including sebum levels and overall severity scores, were assessed. Scalp bacterial and fungal communities were analyzed to evaluate α- and β-diversity and changes in Malassezia composition.
Results:
Treatment resulted in significant reductions in sebum levels and clinical severity scores, particularly in erythema, dandruff, and pruritus. Bacterial community composition remained largely stable, while fungal α-diversity increased, and β-diversity analysis revealed a decrease in the ratio of Malassezia restricta to Malassezia globosa.
Conclusion
AMPamide-containing shampoo was associated with improved clinical symptoms and a shift toward a more balanced fungal community composition in patients with SD, supporting its potential as a non-steroidal therapeutic option for SD.
4.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.
5.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.
6.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.
7.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.
8.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.
9.Asparagi radix alleviates testosterone-induced benign prostatic hyperplasia by inhibiting5α-reductase activity and androgenreceptor signaling pathway
Hyun HWANGBO ; Hee-Jae CHA ; Min Yeong KIM ; Seon Yeong JI ; Da Hye KIM ; Jeong Sook NOH ; Tae Hee KIM ; Heui-Soo KIM ; Sung-Kwon MOON ; Gi-Young KIM ; Yung Hyun CHOI
Nutrition Research and Practice 2024;18(6):793-805
BACKGROUND/OBJECTIVES:
Recently, herbal medicines have gained attention for the treatment of benign prostatic hyperplasia (BPH), a common disease in elderly men. In this study, we aimed to determine the effect of ethanol extract of Asparagi radix (EAR), which is traditionally used to treat various diseases, on BPH development using a testosteroneinduced BPH model.MATERIALS/METHODS: Testosterone propionate (TP)-treated Sprague–Dawley rats were used to establish a BPH model in vivo. EAR was orally administered along with TP, and finasteride was used as a positive control. All rats were sacrificed at the end of the experiment, and pathological changes in the prostate tissue and levels of key biomarkers associated with BPH pathogenesis were assessed.
RESULTS:
Oral administration of EAR significantly inhibited TP-induced BPH by reducing the prostate weight, lumen size, and epithelial thickness in a concentration-dependent manner. EAR also significantly abrogated the expression of 5α-reductase type 2 (SRD5A2), proliferating cell nuclear antigen, and prostate-specific antigen (PSA) induced by TP.Additionally, serum levels of testosterone, dihydrotestosterone, and PSA were elevated in the TP-induced group but decreased in the EAR-treated group. EAR also decreased the expression levels of the androgen receptor (AR) and its coactivators in TP-induced BPH model rats.
CONCLUSION
Our findings revealed that EAR protected against BPH by inhibiting 5α-reductase activity and AR signaling pathway, suggesting its potential for BPH treatment.
10.The Association of Smoking Status with Diabetic Microvascular Complications in Korean Patients with Type 2 Diabetes
Yongin CHO ; Hye-Sun PARK ; Da Hea SEO ; Seong Hee AHN ; Seongbin HONG ; Young Ju SUH ; Suk CHON ; Jeong-Taek WOO ; Sei Hyun BAIK ; Kwan Woo LEE ; So Hun KIM
Yonsei Medical Journal 2024;65(8):427-433
Purpose:
Few studies have investigated the association between smoking and microvascular complications in the Asian population with type 2 diabetes mellitus (T2DM). We aimed to investigate the relationship between smoking status and microvascular complications in Korean patients with T2DM.
Materials and Methods:
From the Korean National Diabetes Program cohort, we included 2316 Korean male with T2DM who had baseline clinical information available, including their smoking status, and underwent diabetic complication studies.
Results:
Compared to non-smokers, current smokers had higher odds of any-microvascular complications [adjusted odds ratio (aOR) 1.45, 95% confidence interval (CI) 1.07–1.97, p=0.016]. The odds of neuropathy were significantly higher; however, the odds of retinopathy were significantly lower in current smokers than in nonsmokers (all p<0.05). Among those who underwent repeated complication tests after 3 years, the risk of newly developed retinopathy was significantly increased in ex-smokers [aOR 3.77 (95% CI 1.61–8.87), p=0.002]. Within ex-smokers, long smoking duration and smoking cessation within the recent 5 years were associated with an increased risk of newly developed retinopathy (all p<0.05).
Conclusion
Male smokers had higher odds of having overall diabetic microvascular complications, including neuropathy. However, the odds of having retinopathy were significantly lower among current smokers. More attention and research are needed regarding the increased risk of retinopathy development in ex-smokers who have recently stopped smoking after a long history of smoking.

Result Analysis
Print
Save
E-mail